Vector Drive - Troubleshooting Guide

Similar documents
Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide

High Voltage Power Supply (MMPS) - Troubleshooting Guide

I/O PCB-R - Replacement

I/O PCB-AC - Replacement

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

Sized for Print U1008-LIN 1 BUS. For a complete wiring diagram refer to Diagrams/Electrical. When Monitored: Continuously while the system is active.

Regenerative Power Module And Common Bus RPM Panels Instruction Manual

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MDM 011-Z1 Regen Resistor

Treadmill Embedded Touch Screen Won t Power Up

AIR COOLED MODULAR RECTIFIER

1352C-Plus 5.1 VECTOR Troubleshooting Guide

Zenith DS9000 Dispensing System

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)

RTK3 Logic Controller User Manual Revised

Monitor - 15-Inch LCD - Replacement

1395 Node Adapter Board Troubleshooting

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

GE Power Management. MMII Intelligent MCC Controller

AC SMARTMOTION CONTROLLERs

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

Spindle Drive - Installation

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

700 Series 200 Amp Clamp Meters

Start Relay Circuit - Test

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

ME3 Mobile Cabinet Three Phase Frequency Converter, Operation and Maintenence.

Exercise 2: FACET Base Unit Familiarization

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

PSU. User s manual. Rev. 0

2003 Nissan Pathfinder SE

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

PHASE MONITOR RELAYS Product Summary

Distributed Power System SA3100 Diagnostics, Troubleshooting, and Start-Up Guidelines

DC3IOB Revision User Guide Updated 3/29/10. Overview

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Fitting Ah-ha to a machine using Gecko Stepper drives

FOR USA AND CANADA COOLING FAN. Component Function Check 1. CHECK COOLING FAN FUNCTION

RTK4 Logic Controller User Manual For RTK4L Revision Revised

2 in 1 LAN Tester and Multimeter Model:

Variable Power Supply Digital Control Circuit Diagram Using Lm317

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Digital Multimeter Damage Prevention

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

DG4S series DC Servo drive

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Installation Instructions

PEM Faults and Blower Failures

Service Manual Saprom S

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Installation Instructions

DC3IOB Revision User Guide Updated 7/12/12. Overview

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

^2 Accessory 8D Option 4

Chassis Power Supplies

Tesla TI Generator Set Interface

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Temperature Programming Quick Reference Guide

Entry Level Assessment Blueprint Electrical Occupations

DC POWER SUPPLY UNIT (MPS, MPR UNIT)

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

Additions, Revisions, or Updates

Network Controller. Installation/Troubleshooting Instructions NK220 COM1131C

Power Supplies. Chapter The McGraw-Hill Companies, Inc. All rights reserved. Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs

User Manual. Solar Inverter for Water Pump

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

vacon nx ac drives brake chopper unit (bcu) application user s manual

SECTION VARIABLE FREQUENCY DRIVES

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Lightning Stitch Assembly

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

GENERAL INF. Description. Applications. Common Data. Power equipments for the control of three-phase charges:

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

This Datasheet for the IC660BBA103. Block 115Vac/125Vdc Thermocouple Input 6 Channels.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SD DRIVE SERIES INSTALLATION MANUAL

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

ac wave 2 supply ( analog device )

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

Transcription:

Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle motor and the servo amplifiers. There are three sizes of Haas Vector drives: 20HP [1], 40HP [2] and 60HP [3]. Electrical Diagram Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On August 21, 2017 1/7

Symptom Possible Causes Corrective Action Alarm 123 SPINDLE DRIVE FAULT and Alarm 993 SHORT CIRCUIT Alarm 2040 VECTOR DRIVE OR SPINDLE-AMPLIFIER SHORT CIRCUIT The vector drive detected a short circuit. Inspect the Vector Drive and the Wye-Delta contactors for a short circuit. For Delta-Wye Contactor Troubleshooting refer to: Wye- Delta Contactor - Troubleshooting Guide. For Vector Drive shortcircuit inspection see section below. Alarm 123 SPINDLE DRIVE FAULT Alarm 648 DC BUS SHORTED SUPPLY FAULT and Alarm 160 LOW INCOMING LINE VOLTAGE the DC Bus. Compare the measured DC voltage to the Diagnostic page. SUPPLY FAULT and Alarm 647 REGEN LOAD SHORTED the REGEN. Measure the resistance across the REGEN leads. SUPPLY FAULT and Alarm 200 HIGH VOLTAGE POWER SUPPLY OVER TEMPERATURE Alarm 2038 VECTOR DRIVE OR SPINDLE AMPLIFIER OVER TEMPERATURE the vector drive cooling fan. Inspect the cooling fan. SUPPLY FAULT and Alarm 444 REGEN REMAINED ON TOO LONG The Machine Fails to Maintain Spindle Orientation. the incoming AC power. The vector drive output is unbalanced. Measure the incoming voltage to the machine. Measure voltage outputs across the vector drive terminals. Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On August 21, 2017 2/7

Electrical Safety Turn the main circuit breaker [OFF]. Danger: Before beginning any work inside the control cabinet the High Voltage indicator light on the 320V Power Supply / Vector Drive must have been off for at least 60 seconds Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On August 21, 2017 3/7

Short Circuit Inspection Inspect the spindle motor cables. Make sure the spindle motor cables are not contaminated or pinched. Inspect the vector drive. Disconnect all the terminals. Set your meter to Ohms. Check terminals 4, 5, 6 to chassis ground. If the meter does not show OPEN (O.L) the vector drive is damaged. Set your meter to diode test mode. Put the red lead on terminal 3 (-) with the black lead measure terminals 2 (+), 9 (A), 10 (B) and 11 (C). Wait until the reading on your meter settles. If the meter does not show a voltage drop ranging from 0.2 to 0.8 volts the vector drive is damaged. Put the black lead on terminal 3 (-) with the red lead measure terminals 2 (+), 9 (A), 10 (B) and 11 (C). Wait until the reading on your meter settles. If the meter does not show OPEN (O.L) the vector drive is damaged. Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On August 21, 2017 4/7

DC BUS Press [POWER ON]. Measure the DC voltage between terminals 2 and 3 on the vector drive. Compare the measured voltage with the DC VOLTAGE on the diagnostics page on the control. The readings must match +-2%. If the readings do not match, the problem can be: A bad connection on the 640C cable. Make sure there is a tight connection on the J3 connector on the Vector Drive and the P17 connector on the Maincon/Mocon. A faulty Vector Drive if you have incorrect voltage at P17. A faulty Maincon/Mocon if you have the correct voltage on the 640C cable at the P17 connector of the Maincon/Mocon. There is 0.01 VDC for every 1 VDC Bus. For example, 320 VDC must show 3.2VDC. Disconnect the DC Bus cables from terminals 2 and 3 on the vector drive. Power on the machine. Monitor the DC VOLTAGE on the diagnostics page of the control. If the DC Bus goes back to the nominal value, there is a short in one of the servo amplifiers. A low resistance or a short is a sign of a faulty servo amplifier. If the readings match and the alarm continues, the problem is a faulty vector drive. Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On August 21, 2017 5/7

Regen Load Press [POWER OFF]. If the vector drive voltage indicator light is on, do not touch the electrical components. The high voltage in the control cabinet can kill you. Wait for the voltage indicator LED on the vector drive to go off completely. Disconnect the REGEN load leads from the vector drive at terminals 1 and 2. Measure the resistance across the leads. The reading must be as follows: 2-resistor box: between 9.5 and 12.5 ohms. 3-resistor box: between 6.3 and 8.3 ohms ohms. (As shown in the illustration.) 4-resistor box: between 4.6 and 6.6 ohms. If the REGEN loads are within specification, there can be a the vector drive. Measure the resistance across terminals 1 and 3 on the vector drive. A short is a sign of a faulty vector drive. Cooling Fan An over-temperature alarm is generated when the vector drive's heat-sink reaches 90 C. The cooling fan must turn ON when the heat-sink temperature reaches 50 C. The cooling fan must turn OFF as the heat-sink cools down. Measure the temperature of the vector drive's heat-sink through the exhaust vents when this alarm occurs. If the temperature is above 60 C and the fan is not ON, the vector drive has a faulty cooling fan. Replace the cooling fan. Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On August 21, 2017 6/7

Incoming AC Voltage Measure the incoming voltage to the machine. Make sure that the incoming voltage is within the range of the transformer s tap. Move the lines to the correct tap if needed. Unbalance Output Inspection Disconnect the motor cables at the vector drive. Push [POWER ON]. Push [RESET] to clear any alarms. Use a multimeter to measure the DC voltage across the following terminals on the vector drive (see the illustration): 3 and 9 3 and 10 3 and 11 The voltage must be 160-175VDC in all three readings. If any of the voltage readings is 0V or 330V, then this is a sign of an unbalanced output from the vector drive. Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On August 21, 2017 7/7