JUMA-TRX2 serial protocol description OH2NLT

Similar documents
User Manual for KD8CEC ubitx software rev 1.061

Function Key ALT CTRL ALT + CTRL CTRL + SHIFT Shift + ALT

User Manual for KD8CEC ubitx firmware rev 1.061

User Manual for KD8CEC ubitx firmware rev 1.072

CAT Controlled Fract-N Synthesizer

BTS-2501 Programming Software for the BTECH UV-2501 &UV

ADMS-4B Programming Software for the Yaesu FT-857 / FT-897

TEAMSPEAK3 via INTERNET SET-UP Used for CW NET and BOD Meeting. The TEAMSPEAK Client software is free and can be downloaded at:

ericssonz LBI-38616B MAINTENANCE MANUAL FOR MTD TM SERIES AND DATA RADIO LOGIC BOARD 19D902151G3 DESCRIPTION CIRCUIT ANALYSIS TABLE OF CONTENTS

PEP950 This procedure is used to update Main CPU V0105 and EDSP V11.39 the flash programming for the FT-950 Transceivers.

CalArts Film/Video Sound Quick Start for Sound Devices 744T Time Code Hard Drive Field Recorder:

Additions and changes. Split tone. ID-5100A/ID-5100E Firmware update information Release E3

For ICOM radio s Download the latest driver from ICOM Japan website they will always have the latest version

1 Installation of the WTI software and drivers

LBI-38599F Maintenance Manual

ADMS-7900 Programming Software for the Yaesu FT-7900

DEV-1 HamStack Development Board

Yaesu FTDX3000 Sound card digital modes setup using internal USB interface for Fldigi (part 1)

3 Setup Form. 3.1 Tuning Step Tab. ELAD FDM- SW2 User Manual Rev /2015

HT-1A Dual Band CW QRP Transceiver. User Manual

M2DIS. User Manual.

User s Manual. Touch Panel Setting Tool. Important

HOW-TO set up the Yaesu FTDX3000 using internal USB interface for Fldigi

ADMS-270 Programming Software for the Yaesu FT-270

DM780 / Navigator Setup

Polycom VVX300 / VVX310 / VVX400 / VVX410

W0EB/W2CTX Firmware for the Micro BITX meter Transceiver for Release V2.00R

BAO-F9 Programming Software for the Baofeng BF-F9

Shows the name of the currently selected RX (!) audio filter. Top line is the upper frequency, lower line the characteristic parameter:

Hello, and welcome to this presentation of the STM32 general-purpose IO interface. It covers the general-purpose input and output interface and how

RcForb Version 9 Client (Preliminary July 31, 2016) File Menu. Login Dialog (self explanatory)

LPC2148 DEV BOARD. User Manual.

MobileMapper 6 Frequently Asked Questions

ADMS-2H Programming Software for the Yaesu FT-8900

Polycom VVX101 / VVX201 User Guide

Using GIGABYTE Notebook for the First Time

PowerSDR with Pi SDR for G59/G11 Software Setup

USB Interface III and N1MM Logger+ setup

Ham Radio Deluxe - Troubleshooting ICOM Radio USB Port Data Modes.

Work State Indicator Upon login, the initial state is Not Ready. Click this to open the dropdown menu.

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

Polycom VVX300 / VVX310 / VVX400 / VVX410. User Guide

Solid State Logic S O U N D V I S I O N

Audio Perfect Tools. Audio Perfect Tools

FTDX9000MP/Contest. Data Management FT DX 9000MP/CONTEST DATA MANAGEMENT OPERATION MANUAL

User s Manual. Touch Panel Setting Tool. Important

ADMS-DX3000 Programming Software for the Yaesu FT-DX3000

BASIC Arduino. Part I

AVR XMEGA TM. A New Reference for 8/16-bit Microcontrollers. Ingar Fredriksen AVR Product Marketing Director

Here's a summary of the SONAR features you can control from the Mackie Control:

Operator Quick Guide ORBISPHERE 3650

FLRIG Users Manual 1.3. Generated by Doxygen

GSDR Basic set up using QRP2000. Modes using third party software will be covered in another tutorial. Remember you must download two files, the

ADMS-8100 Programming Software for the Yaesu FT-8100

2-10 Access Mode, Recall a Ports Access Mode (006) 2-8 Access Mode, Set Up a Ports Access Mode (005) 1-5 Adjusting the Receiver Port 1-5 Adjusting

Welcome! GRAND FINALE. Authorizing. Audio Finalizer

W0EB/W2CTX Software Operating Manual for the MicroBITX Transceiver Using The BITeensio Micro-Controller with an I2C LCD display

FT-991 Memory by F6ECN

CU 6005 DCS 6000 Medium Power Central Control Unit

CONTENTS. dspicpro4 KEY FEATURES 4 CONNECTING THE SYSTEM 5 INTRODUCTION 6

Edge Power International (HK) Ltd. Product Specification

INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1

What can the DD700 Do

ALS-600-LPF User Manual

PJP-25UR Conference Microphone Speaker

USER MANUAL. Published October 2018 Software Version Nomad Zaxcom Nomad. Sound bag audio redefined

ATS-5X User Manual. Networked Communication Solutions, LLC Electrodata, Inc. Copyright 2015 Rev. 04/15

Pridgen Vermeer Robotics Xmega128 Manual

HS-P82. Contents. New functions in firmware V2.00

5000 Series Audio Matrix

MeshConnect. Voice over

AK-STM32-ETH Development Board

Exclusive 2.5 GHz Frequency Counter

User Manual for the AN208

X-TOUCH Firmware V (January 2016)

GPS+CAMTM. User Manual VS55020

Front Panel. 3- Bus switch, This selects which bus the channel is output to. 4- INPUTS these are the inputs to the channels. They accept CV and audio

SWITCHMAN-3 USER MANUAL V3.0

D/ESAM QuickStart Guide

ADMS-VX8 Programming Software for the Yaesu VX-8/VX-8D

744T Quick Start Guide - U.T. Austin

RTTY/CW TX TERMINAL for : IC756 ( all series ), IC7400, IC746, IC7000 (PC not required)

Installation and operation manual ReciFlow Gas

AVR XMEGA Product Line Introduction AVR XMEGA TM. Product Introduction.

Digital Signal Processor TRAINER

Panasonic. DVD/DVC Camera Seminar VDR-D100/200/300 and PV-GS29/39

DD2050 Hopper Scale. datasheet

APK-A10/A40 Programming Software for the Alinco DJ-A10/A40

MiniProSC Hi performance Digital DATA mode interface

High Resolution Digital Audio Recorder User Guide and Technical Information firmware rev. 2.00

Introduction to Microcontroller Apps for Amateur Radio Projects Using the HamStack Platform.

VM-3-SM1. Speaker Microphone with Voice Storage. Manual Revision: Covers Software Revisions: VS-1XXX:

ELAD Application Notes AN- 002 rev 1.0 Setting FDM- SW2 with external programs: CW Skimmer, FLDIGI

GQ GMC-300E Plus Geiger Counter User Guide

Technical Bulletin Autocaller with old Maplin kit Page 1 of 5

AI-917-A0. Analogue Input Module (4x 0-20 ma)

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

LCD Screen. Soft Keys. Handset (Optional cordless handset shown) Speaker. TRANSFER A CALL While connected to a live call

SwitchMan Quartet. Preliminary User s Guide. Dec. 08, 2000 Firmware revisions: Main v1.3, Remote v1.1

Tuff Tread. Grade Calibration

Transcription:

JUMA-TRX2 serial protocol description OH2NLT 22.08.2007 JUMA-TRX2 serial interface protocol can be selected from TRX2 user setup. Long push of DISPLAY button gives setup menu for the user. Short pushes of the DISPLAY button walks through various JUMA-TRX2 setups. Stop at RS232 = xxxxx selection. Now you can select desired serial protocol with VFO knob. Long push of the DISPLAY button leaves the setup menu. All the setup changes are immediately effective and stored to the EEPROM memory during next power off sequence. In all serial protocol modes the default serial settings are 9600-8-n-1. Available JUMA-TRX2 serial protocols JUMA-TRX2 protocol JUMA-TRX2 external keyboard protocol JUMA-TRX2 test commands Yaesu CAT emulation JUMA-TRX2 protocol Not yet defined and implemented in JUMA-TRX2 software version 1.01 JUMA-TRX2 external keyboard protocol This is simple one direction control protocol for JUMA-TRX2 voice memory option control. Commands can be sent to JUMA-TRX2 with JUMA external keyboard or a PC program. If voice memory option card is not installed these commands have no effect. Response messages are echoed to serial interface for debug purposes. This feature is useful if PC with a terminal program is connected to the JUMA-TRX2 serial interface. Voice memory action is also showed on the JUMA-TRX2 LCD display. First a command is selected and then a memory location number where the action is addressed. Available commands (capital letters) Actions P T R M S E Memory numbers Numbers 0 to 9

P Selects play mode. Stored message is played from JUMA-TRX2 speaker. T Selects transmit mode. Stored message is transmitted with current TX settings. R Selects record mode. Audio with current RX settings is recorded (stored) to selected memory location. M Selects record from microphone mode. Audio from JUMA-TRX2 microphone is recorded (stored) to selected memory location. S Stops current action immediately. Play, TX and record commands can be stopped with this command before EOM (end of the memory) is reached. E Erase all. This command is not normally used. Erase all command deletes all messages and removes all EOM markers. Numbers 0 9 After an action is selected a memory number that can be from 0 to 9 defines the voice memory location and starts selected action. Examples Record message from microphone to memory location 1. Select M for microphone input Select 1 for memory #1 and start recording Press S to stop recording Play message from memory location 1. Press P to play Select 1 for memory #1 and start playback Playback stops when whole message is played. Playback action can also be stopped with S command. JUMA-TRX2 test commands Various different test commands are provided for JUMA-TRX2 hardware functionality testing. These commands are not needed or used during normal JUMA-TRX2 operation. Test commands are good help in troubleshooting. Below is a very brief description of available commands. User should see program source code listing for particular command functional details. Commands are single letter commands given from PC terminal. Please note that small and capital letters are different commands.

Available commands in JUMA-TRX2 software v1.01 I info, SW version etc A convert and print all analog inputs E dump EEPROM content C clear EEPROM factory default reset counter W writes from PC terminal to JUMA-TRX2 LCD display B LCD bar graph test s mute audio, stop SCAF filter clocking S audio on, start SCAF filter clocking p print CW speed pot & S-meter A/D conversion values d print some internal VFO select logic values o print reference oscillator calibration value m print internal timing ms counter value t write test data to SPI bus c continous test data write to SPI bus + increase multiband PA RF attenuator value - decrease multiband PA RF attenuator value f print SPI bus control data Z intentional divide by zero, CPU error trap test A convert and print all analog inputs Do A/D conversion for all analog inputs and print raw conversion result values. E dump EEPROM content Dump EEPROM contents. Dump contains stored user defaults and calibration constants. C clear EEPROM factory default reset counter JUMA-TRX2 software keeps track how many factory default resets have occurred. This counter is shown (printed to the serial interface) on every start up. This counter can be reset to zero with this command. W writes from PC terminal to JUMA-TRX2 LCD display Write characters from PC terminal to the JUMA-TRX2 LCD display. W-command is useful help to test LCD compatibility and general operation. Test loop can be stopped with Esc character. B LCD bar graph test Runs bar graph display up and down on the JUMA-TRX2 LCD display. This test verifies LCD display module soft font compatibility. Any character from PC terminal will stop the test loop. s mute audio, stop SCAF filter clocking Mute JUMA-TRX2 audio. Stopping JUMA-TRX2 main board SCAF filter clocks generates mute. S audio on, start SCAF filter clocking

Restart JUMA-TRX2 main board SCAF filter clocks. Opens the audio path. p print CW speed pot & S-meter A/D conversion values Print CW speed potentiometer value and S-meter value. d prints some internal VFO select logic values Print some internal variables used in VFO select logic. o prints reference oscillator calibration value Print DDS reference oscillator calibration value. Nominal value is 180000000Hz m print internal timing ms counter value Print internal 1ms tick counter value. Can be used to verify JUMA-TRX2 software timing. t writes test data to SPI bus Write once 0x5501 test data to the SPI bus. This command can be used to verify SPI bus I/O functions in the main board and multiband PA board. c continuous test data write to SPI bus Same as t-command but writes continuously increasing test data word to the SPI bus. Test loop can be stopped with sending any character from PC terminal. + increase multiband PA RF attenuator value - decreace multiband PA RF attenuator value Increase or decrease multiband PA board RF attenuator value. f print SPI bus control data Print current SPI bus control data. Data correspond current main board and multi band PA SPI I/O state. Z intentional divide by zero, CPU error trap test Performs intentional divide by zero that causes CPU error trap. Command is used to test error trap logic. Yaesu CAT emulation Some Yaesu CAT control protocol commands are implemented in the JUMA-TRX2 software. There is no exact 1:1 match in JUMA-TRX2 functionality and the original Yaesu FT897 CAT specification. Essential commands such as set frequency, read frequency, read s-meter, set mode etc are implemented. Implementation of these essential commands allows JUMA-TRX2 to be controlled by rig control programs. Particular rig control program must be set to Yaesu FT897 control mode. Implemented Yaesu CAT commands 0x03 Read RX frequency and mode 0xE7 Read RX status (S-meter) 0xF7 Read TX status 0x02 Set split on 0x82 Set split off 0x81 Toggle VFO select

0x07 Set operating mode bits 0x01 Set operating frequency 0x08 PTT on 0x88 PTT off 0x00 VFO lock on 0x88 VFO lock off For more details see JUMA-TRX2 software source code and Yaesu CAT specification.