Data Sheet HG400/HG Energy Monitoring with M-Bus: Up to 100 M-Bus energy meters can be monitored by a single Tixi Alarm Modem

Similar documents
Tixi Data Gateway LAN

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Tixi Alarm Modem GSM. Hardware Manual. HG100 and HG400 Series. Version 1.0.1

mark150s mark150/485s DDC controllers Summary

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

IMIO100 IMIO105. DDC controllers. Summary

User Manual. cmt-svr Startup Guide

TM241CE40R controller M IO relay Ethernet

TM221M16TG controller M IO transistor PNP spring

TM221M32TK controller M IO transistor PNP

TM221M16R controller M IO relay

TM241CE40R controller M IO relay Ethernet

TM241CE24U controller M IO transistor NPN Ethernet

TM221CE24R controller M IO relay Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

Accessories / 7XV5820

TM241CE40T controller M IO transistor PNP Ethernet

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

TM241C40R controller M IO relay

TM241CEC24R controller M IO relay Ethernet CAN master

TM221CE40R controller M IO relay Ethernet

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Data sheet CC 03, Commander Compact (603-1CC21)

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

TM241CE40R controller M IO relay Ethernet

TM241C40U controller M IO transistor NPN

TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

TM241C24T controller M IO transistor PNP

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

TM241CE24T controller M IO transistor PNP Ethernet

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

User Manual. cmt-svr Startup Guide

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

General Operating, Maintenance and Installation Manual

SH2WEB24. Central unit module. Benefits. Description

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Operation Manual GSM modem irz TG42-232

RTU32S RTU32S Series Small Compact Utility RTU

OnCell G3100 Series Quick Installation Guide

Data sheet VIPA CPU 115DP (115-6BL22)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TM241CE24T controller M IO transistor PNP Ethernet

TM221ME16T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Supply voltage. Input current. Encoder supply. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

General information. Display. Supply voltage. Input current. Encoder supply. Output current

MGate 4101-MB-PBS Series

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

User Manual A08. User Manual

General information. Display. Supply voltage. Input current

TM221CE24T controller M IO transistor PNP Ethernet

Data sheet CPU 115 (115-6BL02)

DIN Rail RTU 540CMD01 Data sheet

Industrial Serial Device Server

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display

M-Bus Central Unit. Use

Features and Benefits. Certifications

Manual Industry Interfaces

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

TM251MESC controller M251 Ethernet CAN

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

MGate 5105-MB-EIP Series

TM200CE24T controller M IO transistor Source+ Ethernet

General information. Display. Supply voltage

Product type designation. General information. Supply voltage. Input current

RTU32S RTU32S Series Small Compact Utility RTU

General Specifications

TELETERM M2 Series Programmable RTU s

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

USER MANUAL FOR GS100/GS1003G

GNS-MC35iT, GNS-MC35iU Terminals datasheet

EZ864 UMTS Terminal Telit Cellular GSM Engine

General information. Supply voltage

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Feature and Benefits. Certifications

Product type designation. General information. Supply voltage

TM200C24R controller M IO relay

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

HMIGK5310 Keypad-touchscreen panel color x 480 pixels VGA -10.4" - TFT LCD

Transcription:

Data Sheet HG400/HG100 28.3.2009 Tixi Alarm Modem GSM Remote Control Fault Messaging Data Logging Web Server PLC Protocols Energy Monitoring with : Up to 100 energy meters can be monitored by a single Tixi Alarm Modem Tixi Alarm Modem with 4 I/O Modules Tixi Alarm Modems for LAN, wireless LAN or analogue telephone networks: HE400, HW400 and HM series. Tixi Main Unit Tixi I/O-Modules Series HG400 Typ XP84D XP84DR XP88D XR46 XYZ CPU ARM7 Digital inputs 8 8 8 4 Speed 60 MHz Digital outputs 4-8 - RAM 8 MB Relays - 4 - - Flash Memory 8 MB RS232 - - - 1 SD-Card (max.) 2 GB RS485 - - - 1 Number of I/O-modules 2 8 Max. number of I/O-Modules 8 4 4 2 8 Custom Modules Models s HG421 HG427 HG430/ 432/434 HG441 HG447 HG471 HG476 HG423- HG443- HG445- HG425-2S0 COM1 RS232 RS232 RS232 RS232 RS232 RS232 RS232 RS232 RS232 RS232 RS232 COM2/ COM3 RS232 RS232 RS232 RS485/ 422 RS485/ 422 Siemens S7-MPI Siemens S7-MPI RS232 RS485 2xRS485 RS232 Digital Input - 2 12/8/4-2 - 2 2 2-2 Analog Input - 1 1-1 - 1 - - - 1 Digital Output - 2 0/2/4-2 - 2 1 1-1 Relay - 1 - - 1 - - - - - - Metering Interface - - - - - - - 2x pulse input HG100: Special version of the HG400 device, featuring no SD slot (e.g. HG121). PLC Options Optional PLC protocols (Feature Packs) enable direct communication between Tixi Alarm Modems and PLCs - without the need for special drivers inside the PLC: Mitsubishi Moeller Siemens VIPA ABB Saia Burgess Allen Bradley Theben PLC Protocols Alpha XL FX1S FX1N FX2N FX2NC FX3U EASY400 EASY500 EASY600 EASY700 EASY800 MFD-Titan PS4-Serie EasyControl XC/XVC S7-200 S7-300 100V 200V 300V SPEED7 AC010 AC31 AC500 AC800 CL PCD1 PCD2 PCD3 PCS Serie A Serie B GFX Pharao2 MODBUS (RTU, ASCII) TixiBus OEM Protocols for WAGO, Rockwell Automation, Allen Bradley, Schneider Electric, B&R etc. simple protocol for small PLCs (master-slave principle) Upon custom orders for pumps, heating systems (ebus), air condition, data loggers, temperature sensors, radio systems etc.

Tixi Alarm Modem GSM HG400 Data Sheet Page 2/5 Alarm and Fault Notifications Fault Notification Alarm Cascade Address Book Message Templates Features Automatic generation and dispatch of more than 100 fault notifications. Condition based monitoring of data may launch events. Message templates may include current values from PLC or Tixi Alarm Modem variables. Up to 100 predefined events may trigger any action(s). For confirmation of messages, several Alarm levels may be defined freely. Address book with more than 100 contacts, each holding fax, E-mail, Express-E-Mail and SMS address. More than 100 message templates may contain current variable values from PLCs or the Tixi Alarm Modem. Destination addresses and PLC variables are defined as references. Message length is not restricted (only by memory size). Data Logger Data Converter Data Logging Data Dispatch All data of local systems connected to the Tixi device (PLCs, meters, sensors etc) are managed by means of a neutral variable table (XML), independent of their origin. This allows local data to be translated from one system to another, e.g. meter data may be handed to a PLC or BMS (building management system). All values (e.g. PLC or meter values) may be logged on a regular basis, (e.g. every 1 min, 15 min, 1h, 1d, ) and be sent as E-Mail attachments at scheduled times or as a result of any event. Data is automatically compressed (binary format) and may be sent in any desired format, such as XML or Microsoft Excel CSV. Logged data may be sent frequently as E-Mail, Express-E-Mail, fax or SMS at defined time, or upon events. Their Format may be defined freely, e.g. XML or CSV (for use with Microsoft Excel). Embedded Webserver Webserver User-defined websites may contain XML placeholders and can be created by means of any HTML editor. These websites may display current data values, or feature custom input screens. Common Gateway Interface (CGI) allows dynamic read and write of Values and log data readout. Special Server Side Includes allow embedding of values and log data into websites. Remote Control Switch Command Confirmation Remote Switching commands may be sent via E-mail, Express-E-Mail or SMS to the Tixi Alarm Modem. These commands may include parameter values, e.g. setpoint values for PLC registers. If need be, the Tixi device may send confirmation messages upon receipt and execution of remote switching commands, in order to confirm positive or negative result of such. Programmable Features Scheduler Logical Operations Sequencer Arithmetic Operations Event Calendar may trigger the following actions: - Creation of logfile entries or dispatch of logfiles, - Switching I/Os or setting PLC variables, - Dispatch of periodic status messages - Automatic shift schedules may change the receiver of messages. Functions (e.g. AND, OR, XOR, NOT) and comparisons (e.g. GT, LT, EQ) applicable to variable values, even along with time schedules, may trigger actions. Time-dependent data arrays can be preset over a specific span of time, either via configuration or by message. E.g monitoring of current values and dispatch of messages in case that current values exceed min./max. curves (depending on a time grid of 15-min-steps up to one year). Several curve sets may be used in conjunction or as separate data sets. Simple arithmetics (ADD, SUB, MUL, DIV) allows calculation with PLC and variable values. Configuration Configuration via TiXML Security TiXML via GSM connection or COM1-RS232, SD-Card with Batch-File. TiXML is a well-documented open interface based upon XML. Programs or systems may communicate with Tixi devices using TiXML. Access to Tixi device and configuration can be restricted by username and password at several levels - separately for local and remote access

Tixi Alarm Modem GSM HG400 Data Sheet Page 3/5 System and General Features Event E-Mail Reset IP TFTP Local Transparent Mode Special Features E.g.: change of PLC variable(s), exceeding a threshold, scheduled point in time reached, error, PLC connection interrupted etc. Dispatch of E-mail (SMTP, ESMTP), e.g. with log file attachment, Retrieve of POP3 E-mail for the purpose of remote control. Restart the device and retain the current configuration or do a Factory Reset which deletes all settings and returns the device to factory settings IP settings via configuration or automatically via DHCP (Dynamic Host Control Protocol) Upload of websites via TFTP (Trivial File Transfer Protocol) COM1 interface may be looped-through transparently to PLC interface COM2 Upon customer request, features and protocols may be implemented into the Tixi Alarm Modem. Hardware CPU System CPU RAM FLASH Memory System Clock 32 bit ARM7 Processor, 60 MHz 8 MB SDRAM 8 MB (OEM Options: 4 MB, 24 MB, 40 MB) Real Time Clock (RTC), battery buffered Synchronisation with internet time server possible Memory Card Active LED Unmount Button Batch Mode Updates Memory Cards green: SD card mounted red: Read/write access in progress Before removing the SD card, press the "Unmount Button" first and wait until the "Active" LED goes out Upload TiXML configuration, download logged data from internal memory to the SD card Firmware and boot loader update via RS232 or SD card SD cards up to 2 GB Controls Service Button Signal LED Speaker System LEDs Serial Interfaces COM1 RS232 COM2 RS232 COM2 RS485 Firmware TECom Operating System File System OEM Features To be configured by the user: Allows trigger of any kind of action. red/green: User-definable, controllable via TiXML (red-green flashing, 32 variants), e.g. red = fault green = operational red / green flashing modes Mini-speaker for signal tones Power, Process, Connect, Data out, Mode D-Sub 9 female, max. 230.400 bps, ITU-T V.24, V.28, Hardware Handshake, FIFO 16550, All signals: DTR, DSR, RTS, CTS, DCD, GND, RI, RxD, TxD, Transmission distance: 12 m D-Sub 9 male, otherwise the same as COM1 According to EIA/TIA-485, 3-pin screw terminals max 230 kbit/s, not galvanically insulated integrated termination, can be activated by means of DIP switches Transmission distance: 1200 m depending on transmission rate and type of bus and cable Tixi Embedded Communication System TECom offers all basic features for local communication to PLCs and remote communication via cellular and analogue phone networks, LAN/WLAN and IP-based networks. TECom is a platform independent and portable protocol. commercial RTOS (Real-Time Multitasking Operating System MQX) DOS-compliant Flash file system (with wear leveling) All data is retained during power failure. Firmware is open to custom upgrades, such as - New PLC protocols - Calculating and processing functions - Additional web server features

Tixi Alarm Modem GSM HG400 Data Sheet Page 4/5 Compliance DIN EN 13757-2, DIN EN 13757-3 Data Rate Data Format Galvanic Insulation: Pulse Inputs for Energy Meters (S0 pulses) HG400-M25: Master for up to 25 meters HG400-M60: Master for up to 60 meters HG400-M100: Master for up to 100 meters short-circuit-proof Current: 36 V, Bus length: approx. 1 km with M25, telephone wires ø 2 0,8mm, unshielded, 3 screw terminals (grid dimension: 5,08 mm / 0,2"), section max. 2,5 mm² 300, 2.400, 9.600, 38.400 Baud 8 data bits, 1 start bit, 1 stop bit and 1 parity bit (even) 1500 Volt Compliance DIN 43864 2 connectors, connection of active and passive S0 devices Voltage: typically 24 V DC, range: 12-24 V DC, 30 ma Current: inactive state: 0...2 ma, active state: 10...27 ma Debouncing time: 13 ms, line length: max. 3 m, no shielding 6 screw terminals, grid dimension: 5,08 mm / 0,2", cross section max. 2,5 mm² Inputs and Outputs (I/Os) Up to 13 inputs (HG430) and 4 inputs and 4 outputs (HG434) are available in the main unit. Up to 8 I/O modules with up to 128 I/Os can be connected and controlled via one Tixi device, using the Tixi I/O bus. I/Os of the Tixi device Digital via potential-free contacts Inputs Analog 0...10 V DC, resolution: 12 bit Digital potential-free, AC/DC 125 V, 120 ma Outputs Relays potential-free, 230 V AC 3 A or 110 V DC 0,3 A Connectors Screw terminal (grid dimension: 5,08 mm / 0,2"), section max. 2,5 mm² I/Os of the Tixi I/O modules XP84D 8 digital inputs, 4 digital outputs Inputs XP88D 8 digital inputs, 8 digital outputs XP84DR 8 digital inputs, 4 relay outputs OEM-I/Os Upon custom order: digital and analog inputs and outputs, RS232, RS485, relay,... Power Supply Standard Device Version Case Mounting Type OEM Case Dimensions Weight 10...30 V DC, max. 0,7 A (with up to 8 I/O modules) 24 V DC and without I/O modules: max. I = 250 ma 18... 30 V DC, max 0,7 A 2 screw terminals (grid dimension: 5,08 mm / 0,2"), section max. 2,5 mm² DIN Rail 35 mm (EN50022), vertically or horizontally Tixi-H5 Case: DIN-Rail Case Standard OEM DIN-Rail Case: Tixi-H5, grey colour or OEM colour Width / height / depth: 88 mm 57 mm 91mm 225 g Compliance Safety: EN60950 Conformity EMV: EN55022 (9:2003), EN55024 (10:2003) RoHS Temperature Range Operation: -25...+65 C, Storage: -30...+80 C Permitted Humidity 5...95% relative humidity, non-condensing Protection IP20 Degree of fouling 2 Mechanical Fastness Vibration (Sinus) according to IEC 60068-2-6, Vibration (Broadband) according to IEC 60068-2-64 Shock according to IEC 60068-2-27 OEM Models OEM models are available in grey or OEM colours and OEM shapes as well as with OEM hardware interfaces or design or software.

Tixi Alarm Modem GSM HG400 Data Sheet Page 5/5 GSM/GPRS/EDGE Module Network Type Antenna Data Transmission Fax Transmission GSM Communication GSM/GPRS/EDGE Class 10, Quad Band 850/900/1800/1900 MHz FME plug (male), coaxial, impedance: 50 Ohm. Receive frequency: 869...894, 925...960, 1805...1880, 1930...1990 MHz Sending frequency: 824...849, 880...915, 1710...1785, 1850...1910 MHz Output: 2W (900/850 MHz), 1 W (1800/1900 MHz) 300 bps... 14,4 kbps async., transparent/non transparent ITU-T (V.21, V.22, V.22bis, V.26ter, V.32, V.34, V.110) Fax G3, Class 1+2, 2400 bps... 14,4 kbps ITU-T (V.17, V.29, V.27ter) Data compression: MNP2, V.42bis Images