Determination of the aperture of the LHCb VELO RF foil

Similar documents
Simulating the RF Shield for the VELO Upgrade

arxiv: v1 [hep-ex] 7 Jul 2011

First results from the LHCb Vertex Locator

Track pattern-recognition on GPGPUs in the LHCb experiment

Primary Vertex Reconstruction at LHCb

Adding timing to the VELO

Fast pattern recognition with the ATLAS L1Track trigger for the HL-LHC

Section 7.2 Volume: The Disk Method

A New Segment Building Algorithm for the Cathode Strip Chambers in the CMS Experiment

PoS(EPS-HEP2017)492. Performance and recent developments of the real-time track reconstruction and alignment of the LHCb detector.

VELO Module Production - Final Module Metrology

Updated impact parameter resolutions of the ATLAS Inner Detector

HLT Hadronic L0 Confirmation Matching VeLo tracks to L0 HCAL objects

GEANT4 is used for simulating: RICH testbeam data, HCAL testbeam data. GAUSS Project: LHCb Simulation using GEANT4 with GAUDI.

Track reconstruction for the Mu3e experiment based on a novel Multiple Scattering fit Alexandr Kozlinskiy (Mainz, KPH) for the Mu3e collaboration

First LHCb measurement with data from the LHC Run 2

Parameterization of the LHCb magnetic field map

3D-Triplet Tracking for LHC and Future High Rate Experiments

Optimisation Studies for the CLIC Vertex-Detector Geometry

1. INTRODUCTION 2. MUON RECONSTRUCTION IN ATLAS. A. Formica DAPNIA/SEDI, CEA/Saclay, Gif-sur-Yvette CEDEX, France

Tracking and flavour tagging selection in the ATLAS High Level Trigger

Atlantis: Visualization Tool in Particle Physics

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Aim: How do we find the volume of a figure with a given base? Get Ready: The region R is bounded by the curves. y = x 2 + 1

ATLAS NOTE. December 4, ATLAS offline reconstruction timing improvements for run-2. The ATLAS Collaboration. Abstract

Unit #13 : Integration to Find Areas and Volumes, Volumes of Revolution

ATLAS ITk Layout Design and Optimisation

Charged Particle Reconstruction in HIC Detectors

CMS Conference Report

EUDET Telescope Geometry and Resolution Studies

LHC-B. 60 silicon vertex detector elements. (strips not to scale) [cm] [cm] = 1265 strips

What makes Bolt Self-loosening Predictable?

Alignment of the CMS silicon tracker using Millepede II

Torsional-lateral buckling large displacement analysis with a simple beam using Abaqus 6.10

Chapter - 2: Geometry and Line Generations

Full Offline Reconstruction in Real Time with the LHCb Detector

G4beamline Simulations for H8

Status of the TORCH time-of-flight detector

Detector Alignment with Tracks. Wouter Hulsbergen (Nikhef, BFYS)

The LHCb upgrade. Outline: Present LHCb detector and trigger LHCb upgrade main drivers Overview of the sub-detector modifications Conclusions

Performance studies of the Roman Pot timing detectors in the forward region of the IP5 at LHC

Pattern Recognition Comparison: Generic versus Standard

The LHCb Upgrade. LHCC open session 17 February Large Hadron Collider Physics (LHCP) Conference New York, 2-7 June 2014

Triple Integrals: Setting up the Integral

The Trajectory Model for Track Fitting and Alignment

Performance of the GlueX Detector Systems

SUPPLEMENTARY INFORMATION

Beam Position Monitor For High Energy Particle Beams

Forward Time-of-Flight Geometry for CLAS12

LIGHT Measuring Angles

TEC single wire resolution

PoS(TIPP2014)204. Tracking at High Level Trigger in CMS. Mia TOSI Universitá degli Studi di Padova e INFN (IT)

Alignment of the ATLAS Inner Detector tracking system

Beam Imaging and Luminosity Calibration

Basic and Intermediate Math Vocabulary Spring 2017 Semester

FPC Window Mesh Effect and its Correction

Performance of the ATLAS Inner Detector at the LHC

Spring 2010 Research Report Judson Benton Locke. High-Statistics Geant4 Simulations

The LHCb VERTEX LOCATOR performance and VERTEX LOCATOR upgrade

25 The vibration spiral

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies

5 Applications of Definite Integrals

Analogue, Digital and Semi-Digital Energy Reconstruction in the CALICE AHCAL

ATLAS PILE-UP AND OVERLAY SIMULATION

GEODETIC MEASURING METHODS AND SHAPE ESTIMATION OF CONCRETE THIN SHELL SURFACE

Autodesk Fusion 360: Model. Overview. Modeling techniques in Fusion 360

arxiv:hep-ph/ v1 11 Mar 2002

SoLID GEM Detectors in US

Bottom Truss ANALYSIS

High spatial resolution measurement of volume holographic gratings

First Operational Experience from the LHCb Silicon Tracker

Course Number: Course Title: Geometry

AP * Calculus Review. Area and Volume

Lenses & Prism Consider light entering a prism At the plane surface perpendicular light is unrefracted Moving from the glass to the slope side light

8.882 LHC Physics. Track Reconstruction and Fitting. [Lecture 8, March 2, 2009] Experimental Methods and Measurements

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Integrated CMOS sensor technologies for the CLIC tracker

Endcap Modules for the ATLAS SemiConductor Tracker

Tracking and Vertex reconstruction at LHCb for Run II

What is it? How does it work? How do we use it?

ax + by = 0. x = c. y = d.

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Electron and Photon Reconstruction and Identification with the ATLAS Detector

AP Calculus. Slide 1 / 95. Slide 2 / 95. Slide 3 / 95. Applications of Definite Integrals

Applications of Integration. Copyright Cengage Learning. All rights reserved.

Simulation study for the EUDET pixel beam telescope

Mini-Project 1: The Library of Functions and Piecewise-Defined Functions

PoS(IHEP-LHC-2011)002

The figures below are all prisms. The bases of these prisms are shaded, and the height (altitude) of each prism marked by a dashed line:

QUIZ 4 (CHAPTER 17) SOLUTIONS MATH 252 FALL 2008 KUNIYUKI SCORED OUT OF 125 POINTS MULTIPLIED BY % POSSIBLE

3 CHAPTER. Coordinate Geometry

Data Reconstruction in Modern Particle Physics

Physics CMS Muon High Level Trigger: Level 3 reconstruction algorithm development and optimization

Geometry: Semester 2 Practice Final Unofficial Worked Out Solutions by Earl Whitney

SOLIDS.

Quad Module Hybrid Development for the ATLAS Pixel Layer Upgrade

b-jet identification at High Level Trigger in CMS

Math 2 Coordinate Geometry Part 3 Inequalities & Quadratics

ATLAS, CMS and LHCb Trigger systems for flavour physics

Math 7 Glossary Terms

Transcription:

LHCb-PUB-214-12 April 1, 214 Determination of the aperture of the LHCb VELO RF foil M. Ferro-Luzzi 1, T. Latham 2, C. Wallace 2. 1 CERN, Geneva, Switzerland 2 University of Warwick, United Kingdom LHCb-PUB-214-12 1/4/214 Abstract Hadronic interactions in the material of the LHCb Vertex Locator are used to determine the aperture that the RF foil presents to the LHC beam. The aperture is found to be 4.5 mm, to be compared with the nominal value of 5.5 mm. The difference is well within the tolerance of 2.4 mm considered for the safety of the beam.

1 Introduction Decreasing the inner radius of the Vertex Locator (VELO) is a highly desirable scenario for the impending upgrade of the detector [1], since it should lead to improved precision on the measurement of the impact parameter of tracks. Doing so, however, means also decreasing the inner radius of the RF foil from the current value of 5.5 mm. The new nominal radius being considered is 3.5 mm [2]. In order to guarantee the safety of the machine it is important to know just how well the current nominal value of 5.5 mm (see Figure 1 top) has been reproduced with the actual foil cf. the design tolerances [3]. Tomography data from hadronic interactions in the VELO material includes the entire length of the RF foil. This is made possible by using data from beam-gas interactions, which can occur at any point along the beam line. The particles emitted travel within the primary vacuum before possibly interacting with the foil material. The tracks from this secondary interaction continue on and are detected by the VELO. This allows a precise vertex to be formed and hence for the material in the foil to be precisely mapped. The data used in this analysis were taken during proton-proton running of the LHC in 211 and 212, where the single beam energy was 3.5 TeV and 4 TeV respectively. Only events determined by the software trigger to be consistent with a beam-gas interaction are considered. In addition, the event must have been recorded when bunches are not present in both beams at the interaction point, i.e. we select beam-empty, empty-beam and empty-empty but reject beam-beam configurations. Vertices are reconstructed from three or more tracks that each have hits in at least three R and Φ VELO sensors. Vertices along the beamline are removed with a cut on vertex radius. Requiring only one reconstructed vertex in each event effectively removes any remaining non-material interactions. The x and y positions of each vertex in the local VELO frame are calculated by subtracting the co-ordinate of the beamspot position (as given by the VELO motion system) from that of the vertex in the global LHCb frame. The resulting data can be used to make a determination of the aperture available to the beam due to the mechanical tolerances of the RF foil construction and positioning. 2 Results The method for the determination of the true aperture is to examine the vertices attributed to the RF foil in the z regions where it is at its smallest radius, i.e. the regions around the sensor slots. Figure 2 shows how the foil radius varies with the z position in these regions. We take windows of ±1 mm around the nominal z position of the centre of the slot in order to minimise the effect of the curvature in the rz plane on the measurement but still have a sufficiently large number of vertices to make a good fit. The radius of curvature in the rz plane is 5.8 mm (as seen in Fig 1 bottom). Using this value and the ±1 mm window we find the effect of this curvature will be of the order of.5% on the measured aperture and as such is negligible compared with the other uncertainties. Figure 3 shows the xy projection in two such regions, one where the slot is occupied by a sensor and one where it is empty. The structure of the RF foil from both halves of the VELO can be clearly 1

Figure 1: Projection in the (top) xy and (bottom) rz planes, showing the designed cross section of the current RF foil at the point where the foil approaches closest to the beam axis. seen. Requirements (indicated by the lines in Fig. 3) are placed on the positions of the vertices to select only those in the region at small radius where the shape of the foil is approximately annular. These data are then fitted to a circle with variable centre position and radius. The results for all slots on both sides, are given in Fig. 4. The variation of the x and y co-ordinates of the centre of the fitted circle and its radius are given as a 2

Vertex r [mm] 2 18 16 14 12 1 8 6 4 2 LHCb VELO - Collision Data 15 2 25 Vertex z [mm] Figure 2: The rz-plane distribution of vertices of hadronic interactions with y < 5 mm in the region of VELO module VL7C. function of the z position of the slot. One notes a dependence of the y-centre on the z position. This is partly explained by the actual box shape (as observed in metrological measurements performed on the right box before installation) and partly by tilts of the detector halves in the yz plane. The spread of the x-centre values is representative of the actual imperfections in the foil geometry. The aperture presented by each slot is overlaid on a single plot, assuming a circular shape in the fitted region and with a.15 mm reduction in the radius to account for the thickness of the foil. The value of.15 mm is half the nominal thickness of the foil before deformation into its final shape. Studies of the foil have shown that the pressing of the foil results in some areas being thinned but no parts have been found to be thicker than the original thickness. Since the determination of the true thickness at each station position from the tomography data is complicated by the varying vertex resolution, the original half thickness of.15 mm was used as a conservative upper bound of the actual half thickness. These results combine to give a value for the aperture of 4.9 mm compared with the nominal value of 5.5 mm. The welding of the foil to the RF box must also be considered. Figure 5 shows the rz projection of the reconstructed vertices in the regions at the upstream and downstream ends of the foil. The protrusion due to the weld is clearly visible, in particular in the downstream direction (positive z). Figure 6 shows the xy projections in the regions around the weld joints: 336 < z < 332 mm and 761 < z < 765 mm. As before, further selections are applied to select only the vertices where the foil shape is approximately annular and the resulting distributions of the radius are also shown in Fig. 6. It can be seen that the welding further reduces the aperture to approximately 4.5 mm. Even so, the difference with respect to the nominal value of 5.5 mm is well within the tolerance of 3

LHCb VELO - Collision Data Vertex y [mm] Vertex y [mm] 3 2 1 3 2 1-1 -1-2 -2 3-2 -3 2 Vertex x [mm] LHCb VELO - Collision Data Vertex y [mm] Vertex y [mm] -3 2 1 3-1 -1-2 -2-3 2 Vertex x [mm] 2 Vertex x [mm] LHCb VELO - Collision Data 1-2 -2 2-3 LHCb VELO - Collision Data -2 2 Vertex x [mm] Figure 3: Vertices of hadronic interactions in the LHCb VELO material. (top) Slots in the foil where a sensor is present: (right) 64 < z < 66 mm, (left) 79 < z < 81 mm. (bottom) Slots in the foil with no sensor present: (right) 384 < z < 386 mm, (left) 399 < z < 41 mm. The vertices selected for further analysis must satisfy the conditions: 4.5 < r < 6.57 mm (indicated by the two green circles), y < 4 mm (indicated by the two horizontal red lines) and x > 2 mm or x < 2 mm (indicated by the vertical blue line). 2.4 mm that was reserved for mechanical imperfections of the foil when considering the safety of the beam [3]. 4

3 Conclusion Tracks originating from hadronic interactions in the material of the VELO have been used to reconstruct the position of those interactions. These in turn have been used to determine the location of the RF foil at each point where it most closely approaches the beam. Combining this information we find that the smallest circular aperture that would fit within the two foils is 4.5 mm compared with the nominal value of 5.5 mm. This is well within the tolerance of 2.4 mm that was considered for the safety of the beam when the design radius was initially chosen. References [1] LHCb collaboration, LHCb VELO Upgrade Technical Design Report, LHCB-TDR-13. [2] R. B. Appleby et al., VELO aperture considerations for the LHCb Upgrade, LHCb- PUB-212-18. [3] Minutes of a meeting on LHC Impedance, held on 12 June 1998, http://wwwslap. cern.ch/collective/impedance.wkg/12-6-98/notes.ps. 5

x-centre [mm] 1.8.6.4.2 -.2 -.4 -.6 -.8-1 5 z [mm] y-centre [mm] 1.8.6.4.2 -.2 -.4 -.6 -.8-1 5 z [mm] radius [mm] 6.4 6.2 6 5.8 5.6 5.4 5.2 5 4.8 4.6 5 z [mm] radius + x-centre [mm] 6.4 6.2 6 5.8 5.6 5.4 5.2 5 4.8 4.6 5 z [mm] y [mm] 4 3 2 1-1 -2-3 -4-5 5 x [mm] Figure 4: Results of fitting a circle to the selected vertices at each slot position. The solid red squares (open blue triangles) indicate the foil with positive (negative) x co-ordinate. (top left) The variation in the x co-ordinate of the centre of the fitted circle. (top right) The variation in the y co-ordinate of the centre of the fitted circle. (middle left) The variation in the radius of the fitted circle. (middle right) The x co-ordinate of the foil at y =, i.e. the sum of the x co-ordinate of the centre and the radius of the fitted circle. (bottom) A visualisation of the true aperture. The solid black circle is the nominal aperture, i.e. a circle of radius 5.5 mm. The dashed blue and red semi-circles correspond to the fitted circles found at each slot position, where the fitted radius has been reduced by.15 mm to take into account the foil thickness. The dotted black circle is the true aperture of 4.9 mm given by the combination of the fitted circles. 6

Figure 5: Vertices of hadronic interactions in the LHCb VELO material. rz projection in the regions where the foil is welded to the sides of the RF box. 7

Figure 6: Vertices of hadronic interactions in the LHCb VELO material. (top) xy projection in the regions of the welding: (left) 336 < z < 332 mm and (right) 761 < z < 765 mm. (bottom) Radius plotted for each point which satisfy the conditions: 4 < r < 6.75 mm (indicated by the two green circles) and y < 4 mm (indicated by the two horizontal red lines). 8