Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Similar documents
Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS

GT- IRDM-9603 Product description Rev. 2 17/06/2014

EZmoto V4.1 Product description Rev. 2 30/07/2015

EZ864 UMTS Terminal Telit Cellular GSM Engine

GT-HE910-EUD Product description Rev. 9 17/03/2013

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

Hardware Interface Description

Product description Rev. 3 11/06/14

Hardware Interface Description. Java Box Terminal Motorola G24 Cellular + GPS Engine

GC864-QUAD-C2 / PY-C2 Product Description 80273ST10023a Rev. 2-23/03/07

Hardware Interface Description

GC864-QUAD-C2 Product Description 80273ST10023a Rev. 0-13/09/06

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

CC864-K Product Description. CC864-K 80342ST10060a Rev1.0 May 2009

MC 11 EB-2 Power supply cabinet with external bus, AC version

Universal Power Supplies

M60 SMS Reference Manual V5

Enclosed Power Supplies

TVI I300 Hardware Manual Essential Viewing Systems Limited Essential Viewing. TVI I300 Hardware Manual. Page 1

Hardware Interface Description

Skywire GPRS Embedded Cellular Modem Datasheet

NI Serial Hardware Specifications Guide

CF Plug-In. Evaluation Board User Guide. Bulletin Revision Date

Features. Applications and Benefits TRC ELECTRONICS, INC

Quick Start Guide CJB1950ALAAB

SCC-AO10 Isolated Analog Output Module

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Industrial Power Supplies

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

NI PXI-2567 Specifications

Safety Standards. Model Number: Unit Weight:

Gelo LED Driver 100W, Single output RGLD100-24

Industrial Power Supplies

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

GNS-MC35iT, GNS-MC35iU Terminals datasheet

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Skywire HSPA+ HE910 Embedded Cellular Modem Datasheet

C B. Models. Operating up to 5000m altitude 5 year product warranty

Skywire LTE LE910 Embedded Cellular Modem Datasheet

CPCI-PS24 24V-Power Supply

Safety Standards. Model Number:

Safety Standards. Model Number:

Skywire LTE LE910 Embedded Cellular Modem Verizon Network Datasheet. NimbeLink Corp Updated: September 2014

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

SCC-RLY01 Relay Module

Stratos DVI Fiber Optic Extenders

Skywire 4G LTE Cat 3 Embedded Cellular Modem Datasheet

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

GSM SECURITY AND CONTROL SYSTEM ESIM021

Safety Standards. Model Number:

NI PXI-1042 Series Power Supply Shuttle

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

Safety Standards. Model Number:

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Safety Standards. Model Number:

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Safety Standards. Model Number:

Industrial Power Supplies

Industrial Power Supplies

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Safety Standards. Model Number:

Skywire 2G 1xRTT Embedded Cellular Modem Datasheet

Flat. PITK-W025B Flat 23W LED Driver. Features. Specification Summary. Input Specifications 1 / V / 0.57A / 23W. Mechanical Outline

Safety Standards. Model Number:

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

80W (16V/5A) Power Supply with USB Output. User Manual

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

RocketPort Plus Hardware Installation

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Accessories and options

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

One Touch W800 Quick Guide

Output Voltage* (nom.)(adjustable)

SD-50 Vehicle Dock. Introduction. Highlights. Ordering

Control equipment. Installation & maintenance

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

RoHS COMPLIANT 2002/95/EC

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

F1000 User's Manual. (Version: V1.01)

jcmtechnologies GSM-CARD/VGSM-CARD user s manual communications card

PHOENIX CONTACT - 07/2006

CPCI - 6U - AC - 600W

Flat. PIFN-C072B Flat 75W LED Driver. Features. Electrical Specifications. Input Specifications 1 / 8 18V - 23V / 2.00A - 3.

TRC-190 User s Manual

Safety Standards. Model Number:

Lenovo S60-a. Quick Start Guide. Read this guide carefully before using your smartphone.

EH-RIO IP67 Profibus-DP I/O modules

Transcription:

Aarlogic TER-GX910 Product description Rev.9 17/03/2013

Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface description... 5 3.1 Molex 4 pin connector Power connector... 5 3.1.1 Power Supply... 5 3.1.2 Supply voltage requirements... 6 3.2 USB CONNECTOR... 6 3.3 SMA CONNECTOR... 6 3.4 SIM DRAWER... 6 3.5 RS-232 Interface... 7 3.6 AUX Interface... 8 3.7 Status LED... 9 3.7.1 Red LED... 9 3.7.2 Green LED... 9 4 OPTION: Watchdog operation... 10 5 Mechanical Characteristics... 11 5.1 General mechanical description... 11 5.2 Environmental Requirements... 11 5.3 Protection Class... 11 5.4 RoHS compliance... 11 6 SAFETY RECOMMENDATIONS... 12 7 Certifications... 13 2

1 Overview The TER-GX910 is a complete Cellular Terminal solution for GSM applications. Based on Telit GE910 module. 2 Hardware Interface Description 2.1 Main features of the TER-GX910 Feature Incorporates Telit GE910 module OPTION: PIC16F1824 Microcontroller Frequency bands Power supply ADC and GPIO inputs Communication Implementation The Telit module handles all GSM processing with PYTHON script For Modem ON/OFF and Watchdog GSM: 850/900/1800/1900MHz Single supply voltage 6V DC to 55V DC connector 4 pin micro-fit 3mm Two outputs optocouplers open collector drive 100ma Two inputs optocouplers, 0-55v One ADC 10 bit, 0-55V connector 6 pin micro-fit 3mm Modem Full RS232, connector D-Type 9pin (DB-9) Modem USB, Connector USB Type B High retention Antennas GSM GPS/GLONASS via SMA connectors 3

2.2 Hardware block diagram 4

3 Interface description 3.1 Molex 4 pin connector Power connector 3.1.1 Power Supply The power supply of the TER-GX910 Terminal requires a single voltage source of POWER 6V-55V capable of providing a peak during an active transmission. The TER-GX910 Terminal is protected against supply voltage reversal. An internal fuse 1.1A 60V ensures an electrical safety according to EN60950-1. This fuse is not removable. A fast blow fuse of 0.8A is necessary for 24V power supply system (for vehicles). The power supply recommended being any safety approved power supply certified IEC 60950-1 or EN 60950-1 or UL 60950-1 with limited output current up to 2A. The type of the receptacle assembled on the TER-GX910 Terminal is 4 pin Micro Mate-N-LOK 3mm (0.11 inch) from MOLEX. Signal name Use 1 POWER Input Power supply range 6-55V 2 Power Enable Control pin to turn ON/OFF Terminal power. When putting this pin to voltage >6V the unit will be turn OFF. When putting this pin OPEN or GND the unit will be turn ON. 3 GND Ground 4 Not connected Pin assignment of the power plug including power supply and Power Enable. 5

3.1.2 Supply voltage requirements The DC power supply must be connected to the POWER input: Input voltage range 6-55V DC Nominal Voltage 12V DC Power Supply current rating: max. 2A @12V Power Supply ripple: max. 120mV Input current in idle mode: 20mA @ 12V Input average current in communication mode: 100mA @ 12V 3.2 USB CONNECTOR The USB CONNECTOR of the TER-GX910 Terminal is USB TYPE B, This USB TYPE B CONNECTOR on the TER-GX910 is a High retention connector. It will need 15 Newton to disconnect the USB CONNECTOR. 3.3 SMA CONNECTOR The TER-GX910 Terminal uses SMA CONNECTORS for ANTENNAS. For CELLULAR ANTENNA use the 5 band ANTENNA with 2.5dB gain. 3.4 SIM DRAWER Please insert the SIM card on the following direction into the SIM push-push. 6

3.5 RS-232 Interface The serial interface of the TER-GX910 is intended for the communication between the GSM module and the host application. This RS-232 interface is a data and control interface for transmitting data. It accepts, AT commands and provides multiplexed channels. EMC immunity complies with the vehicular environment requirements according to EN 301 489-7. The user interface of the TER-GX910 is accessible from a Data Terminal Equipment DTE connected to the RS232 interface and it is managed by AT commands according to the GSM specification. The supported commands are listed in the AT Commands Reference Guide. Connector type on the terminal is: RS-232 through D-Type 9-pin female Baud rate from 300 to 230,400 bit/s Short circuit (to Ground) protection on all outputs. Input voltage range: -12V to +12V 7

3.6 AUX Interface The AUX interface provides via Male 6-pole plug connector, the following options: 2 digital inputs optocouplers, input 0-55vdc. 2 outputs optocouplers, drive up to 100ma, external diode needed when driving a relay. 1 ADC (10 bit) input 0-55v. 1 Ground pin. 8

3.7 Status LED 3.7.1 Red LED The Red LED is connected to GPIO1, OFF by default. Red LED status Device Status permanently on a call is active fast interrupt sequence (period 0,5s, Ton 1s) slow interrupt sequence (period 0,3s, Ton 3s) permanently off Net search / Not registered Registered full service device off The LED can use for Network status or controlled by the user. To activate GSM status Red LED "AT#GPIO=1,0,2;#SLED=2,1,1" Red LED ON: "AT#GPIO=1,1,1" Red LED OFF: "AT#GPIO=1,0,1" 3.7.2 Green LED The Green LED is connected to GPIO7, ON by default (at power up). Green LED status permanently ON permanently OFF Device Status Device active device off Green LED control: Green LED ON: "AT#GPIO=7,1,1" (Default) Green LED OFF: "AT#GPIO=7,0,1" 9

4 OPTION: Watchdog operation The TER-GX910 has internal Watchdog option. If the modem was turns OFF, the watchdog will start the modem each 30 min. PYTHON script Watchdog: 1. New terminal will be shipped with the Watchdog disable. Watchdog starts working, only when the Modem`s GPIO8 changes first time to HIGH and then LOW. Each time terminal will turn OFF and ON, Watchdog will be disable. 2. Standard operation of the PYTHON script, each 2min the PYTHON script will change GPIO8 HIGH for 1 second or more and then back to LOW. 3. If the PYTHON script is not changing the GPIO8 every 2min, the Watchdog will restart the internal power supply, which will reboot the terminal. 4. To start the Watchdog operation: "AT#GPIO=8,0,1;#GPIO=8,1,1" 10

5 Mechanical Characteristics 5.1 General mechanical description Weight Dimensions (max) L x W x H 180g (6.35oz) 0.4 lb 83mm x 64mm x 34mm 3.26inch x 2.51inch x 1.33inch Case material Aluminum 5.2 Environmental Requirements Operating temperature range -20 C to +55 C -4 F to 131 F -30 C to +70 C -22 F to 158 F Humidity 5% - 85% The module is fully functional (*) in all the temperature range and it fully meets the ETSI specifications. The module is fully functional (*) in all the temperature range. Temperatures outside of the range 20 C to +55 C (- 4 F to 131 F) might slightly deviate (*)Functional: the module is able to make and receive data calls and SMS. 5.3 Protection Class IP40 Avoid exposing the Terminal to liquid or moisture. 5.4 RoHS compliance All hardware components are fully compliant with the EU RoHS and WEEE Directives. 11

6 SAFETY RECOMMENDATIONS READ CAREFULLY 1. The unit does not provide protection from lightning and surge. For outdoor installation use outdoor nonmetallic case safety approved according UL 50. Additionally you should provide protection from lightning and over voltage according National code. 2. Be sure the use of this product is allowed in the country and in the environment required. The use of this product may be dangerous and has to be avoided in the following areas: Where it can interfere with other electronic devices in environments such as hospitals, airports, aircrafts, etc. Where there is risk of explosion such as gasoline stations, oil refineries, etc. It is responsibility of the user to enforce the country regulation and the specific environment regulation. Do not disassemble the product; any mark of tampering will compromise the warranty validity. We recommend following the instructions of the hardware user guides for a correct wiring of the product. The product has to be supplied with a stabilized voltage source and the wiring has to be conforming to the security and fire prevention regulations. The product has to be handled with care, avoiding any contact with the pins because electrostatic discharges may damage the product itself. Same cautions have to be taken for the SIM, checking carefully the instruction for its use. Do not insert or remove the SIM when the product is in power saving mode. The system integrator is responsible of the functioning of the final product; therefore, care has to be given to the external components of the unit, as well as of any project or installation issue, because the risk of disturbing the GSM network or external devices or having impact on the security. Should there be any doubt, please refer to the technical documentation and the regulations in force. Every unit has to be equipped with a proper antenna with specific characteristics. The antenna has to be installed with care in order to avoid any interference with other electronic devices and has to guarantee a minimum distance from the body (20 cm/8 ). In case this requirement cannot be satisfied, the system integrator should assess the final product against the SAR regulation. The European Community provides some Directives for the electronic equipment introduced on the market. All the relevant information available on the European Community website: http://europa.eu.int/comm/enterprise/rtte/dir99-5.htm The text of the Directive 99/05 regarding telecommunication equipment is available, while the applicable Directives (Low Voltage and EMC) are available at: http://europa.eu.int/comm/enterprise/electr equipment/index en.htm 12

7 Certifications Name: Industrial GSM Communication unit Model: TER-GX910 Reference standard(s): Radio Number Market Standard Procedure 1 Europe EN 301 511 V9.0.2 Spurious Emissions testing EMC Number Marke Standard Procedure 2 Europe EN 301 489-7 V1.2.1 partial testing and report 3 USA 47 CFR part 15:06 sb.b Verification Safety Number Market Standard 4 Europe EN 60950-1:06 DoC Procedure 13