Structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling.

Similar documents
Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)

OPTICAL FIBER INTRODUCTION

Fiber Optical Cabling Infrastructure Offer

Pretium EDGE Solutions Trunk Cable, OM3, Low-Loss, MTP to MTP, 24 fibres

Fiber Optical Cabling Infrastructure Offer

Data sheet PM PCC OpDAT patch cord LC-D/LC-D OM3 aqua, 20.0 m

Plug & Play Universal Trunks

EDGE Solutions Trunk Cable, OM4, Low- Loss, MTP to MTP, 12 fibres

EDGE8 MTP Trunk Cable

Pretium EDGE Solutions Trunk Cable, OM4, Low-Loss, MTP to MTP, 24 fibres

FLAME RETARDANT RIBBONIZED FIBER

Strength member Waterblocked EGlass fibre elements Sheath 1.0 mm black FireBur sheath, UV stabilised, IEC Sheath marking Draka I/O CT LSHF 1.

Alternative Energy Solutions

Fiber Optical Cabling Infrastructure Offer

FiberSolutions. Fiber Optic Cable & Assembly Solutions

EDGE Solutions Hybrid Trunk, OM4, Low- Loss, MTP to LC Duplex Uniboot, 24 fibres

SPEC SHEET. Multimode Patch Cords and Pigtails. Cable types. Description. Features. Fiber types

Draka Black Universal central tube cable 1000N central tube cable w 2 24 fibres, glass elements and black FireBur sheath, VDE U-DQ(ZN)BH Application a

Pretium EDGE Solutions Trunk Cable, 50 µm multimode (OM3)

Indoor Cable Application Note

Polymer Coated Fiber Cable (PCF)

Application Note AN114

MTP Outdoor Cabling System

FiberConnect FiberTech FiberSwitch FiberSplit

EDGE Solutions Trunk Cable, SMF-28 Ultra OS2, MTP to MTP, 12 fibres

INDUSTRIAL TRAY CABLE PRODUCTS

barpa Values Website & Social Network

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

SUMITOMO SPECIFICATION. FutureFLEX. Multimode 62.5 µm Core Optical Fiber (OM1) Gigabit Grade

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

Sumitomo Fiber Specification SE-7** Non-Zero Dispersion Shifted Single-Mode Fiber. PureMetro SM Optical Fiber, TIA Type Ivd, ITU-T G.

13-SDMS-01 REV SDMS-01, REV.00 SEC DISTRIBUTION MATERIALS SPECIFICATION DATE: G

Pretium EDGE Solutions Harness, 12 fibres,

Sumitomo Fiber Specification SE-5** PureBand Single-Mode Fiber. Zero Water Peak (ZWP) Attenuation Optical Fiber, ITU G.

Cable assembly types. L tot. Total length* L tot end-to-end total (min. 0.5 except receptacles)

Pre-terminated Multi Fibre Cable Assemblies

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

259 Yorktown Road, College Town, Berkshire, GU47 0RT Tel: Fax:

TECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5

Multi-Fibre Loose Tube Cable Assemblies

QuickSpecs. Models. Features and Benefits Connectivity. HP V2124 Switch. HP V2124 Switch. Overview

FutureLink Modular. Fiber Optic Cabling System. Issue 1. Corning Cable Systems. Project Services. Data Centers OEM. Private Networks.

TIA 942. no need for dust caps. Pretium EDGE Solutions

Panduit Certified Installer. Fiber Certification Review

MTP Cabling Overview. MTP Cabling System

MTP Multi Lite Trunk Assemblies

Adventum Plenum Rated Indoor/Outdoor Optical Cable

Optical Fiber Assemblies

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

Ultra Low Loss (ULL) LazrSPEED 550 OM4 LC to LC, Fiber Patch Cord, 1.6 mm Duplex, LSZH

SC/APC Connector. CATV Active device Telecommunication. Metro Local Area Data processing

OXIN Setting the Standards Fiber Optic Cable

MTP/MPO Cable Assemblies

Multifibre Full Breakout 1.6mm Cable Assemblies

Opt-X Enterprise Fiber Trunk Cables

HP G Switch HP G-2SFP Switch HP G-2SFP+ 10G Uplink Switch HP G-PoE+ (124W) Switch

OPTICAL CABLE & CABLE ASSEMBLY

Product Classification. General Specifications. Construction Materials. Dimensions. Environmental Specifications. General Specifications

Models HP G Switch

Optical Fibre Assemblies

NETWORKING SOLUTIONS NETWORKING SOLUTIONS. freephone

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

PreCONNECT PURE: Reliable planning of data center cabling OPTICAL SOLUTIONS & INFRASTRUCTURE

Pre-Terminated. FiberExpress

PREMIUM GRADE PATCHCORD / PIGTAIL

PREMIUM GRADE PATCHCORD / PIGTAIL

P R O D U C T C AT A L O G T ALOG

Multifiber Full Breakout Cable Assemblies

HP 1700 Switch Series Overview

QuickSpecs. Models HP G Switch

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo

ADVENTUM OUTDOOR / INDOOR FIBER OPTIC CABLE

Retired. IEEE 802.1p prioritization: delivers data to devices by honoring the priority and type of traffic

Retired. Models HP Switch. HP PoE Switch

HP G Switch HP G-2SFP Switch HP G-2SFP+ 10G Uplink Switch HP G-PoE+ (124W) Switch HPE OfficeConnect G Switch

HP 1905 Switch Series Overview. Models HP Switch. HP G-PoE Switch

Models HP Switch. HP PoE Switch

Data Center & Cloud Computing Infrastruture Solutions DATASHEET. MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System

FIBER OPTIC PRODUCTS FOR THE MINING INDUSTRY

Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

121700A Paired - Category 5e DataTuff Twisted Pair Cable

DINTEK LAN Cabling Systems

Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749

Cisco 10GBASE SFP+ Modules

9/27/04 cci Cablecom Inc. 1

S178A. Hand-Held Core-Alignment Fusion Splicer

N-4 FIBRE OPTIC CABLES

QuickSpecs. HPE OfficeConnect 1420 Switch Series. Overview. Models. Key features

Qualified Partner Programme QPP. Fiber Optic Gigabit Ethernet Theory Felice Guarna

Everything you wanted to know about cabling, but were afraid to ask

HP 4210 Switch Series Overview. Models HP PoE Switch

Retired. Models HP PoE Switch

Fiber Optic. Connector accessories. Edition 2018/09

Product information 19" 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330

March 2018 OM1 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OM4 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OS2 SINGLEMODE DUPLEX FIBRE OPTIC CABLE 500M

Serial Storage Architecture. Fibre-Optic Extender 160 Application Guide

PreCONNECT DUODECIM PRODUCT INFORMATION

HP V1810 Switch Series Overview. Models HP V1810-8G Switch

2001 PRODUCT CA T ALOG

QuickSpecs. Models HP PS G Switch

Transcription:

GIBT Breakout Cables Indoor I-V(ZN)HH 05-0- v6.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 4 6.5/5-OM GIBT0 GIBT04 GIBT06 GIBT08 GIBT GIBT4 50/5-OM BI GIBT0 GIBT04 GIBT06 GIBT08 GIBT GIBT4 50/5-OM3 BI GIBTD0 GIBTD04 GIBTD06 GIBTD08 GIBTD GIBTD4 50/5-OM4 BI GIBTE0 GIBTE04 GIBTE06 GIBTE08 GIBTE GIBTE4 9/5 ITU G.657A BI GIBTA0 GIBTA04 GIBTA06 GIBTA08 GIBTA GIBTA4 9/5 ITU G.657A BI GIBTF0 GIBTF04 GIBTF06 GIBTF08 GIBTF GIBTF4 9/5 ITU G.657B3 BI GIBTI0 GIBTI04 GIBTI06 GIBTI08 GIBTI GIBTI4 Std. reel (non-returnable) 800 * 475 mm weight 7.65 kg 000 * 530 mm weight 8 kg 50 * 688 mm weight 8 kg Std. delivery length 00 ± 05m Applications Structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM. Easy to install in ducts, tunnels and trenches. Features & Benefits The individual single fibre units (of which these metal-free breakout cables are composed) permit direct (detensioned) terminations with separate single-way connectors, which eliminate splicing of pigtails and/or breakout kits. These cables are halogen-free (= FRNC and LSNH) and metal-free (all dielectric). Predicted lifetime > 30 years.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794). Primary coated optical fibres: Ø 80 ± 0 µm.. Tight buffered fibres: Ø 0.90 ± 0. mm. 3. Aramid yarns as strength members. 4. Yellow (SM fibre) or Orange (MM fibre) halogen-free (FRNC/LSNH) numbered jacket (Ø. ± mm) 5. Tape. 6. Yellow (SM fibre) or Orange (MM fibre) halogen-free (FRNC/LSNH) outer jacket with rip cord. Identification: BELDEN OFC cable type number x type of fibre + date-, meter-and -marking. Mechanical Data No. of fibres 4 6 8 4 Cable core +BE CE+4 CE+6 CE+8 3+9 +8+4 Ø nom. (mm) 5.3 6. 8.0 9.4 4.3 Max. pulling tension (N) Short term 400 400 590 770 870 750 Weight (kg/km) 5 3 59 77 87 75 Energy of Flame (kj/m) 379 507 98 35 44 677 CE = Central Element, BE = Blind Element (filler)

Optical Characteristics Characteristics Single-Mode Matched-Cladded optical fibres according to ITU. Fibre-Type Mode-Field /Cladding Diameter (um) Attenuation B typical/ max. (db/km)) Dispersion (ps/(nm-km) PMD A (ps/km) Cable Cut-off A 9/5 G.657A BI 8.9 ± 0.4 4.8 ± 0.3 30 65 0.34 / 0.35 0.9 / 0 / 4 3.5 8 0.06 60 F 9/5 G.657A BI 8.9 ± 0.4 4.8 ± 0.3 30 65 0.34 / 0.35 0.9 / 0 / 4 3.5 8 0.06 60 I 9/5 G.657B3 BI 8.8 ± 0.4 5 ± 0.4 30 65 0.34 / 0.35 0.9 / 0 / 3 3.5 8 0.06 60 Note A- Link design value Note B- Due to cabling the optical attenuation values can increase with max 0.5 db/km (30 nm), max. 0.09 db/km ( nm) and max. 7 db/km (65 nm) Characteristics Multi-Mode Graded-Index optical fibres according to IEC 60793 Fibre- Type Core/ Cladding Diameter (um) Attenuation C typical/ max. (db/km)) Bandwidth (MHz km) Ethernet Performance (m) GBE 0 GBE Num. Apert. (µm) 6.5/5 OM 6.5 ±.5 5 ±.7 / 3.0 0.7 / 0.8 00 600 0 33 75 ± 0.05 50/5 OM BI 50 ±.5 5 ±.3 /.5 / 0.6 600 600 83 0 ± 0.05 D 50/5 OM3 BI 50 ±.5 5 ±.3 /.5 / 0.6 000 0 ± 0.05 E 50/5 OM4 BI 50 ±.5 5 ±.3 /.5 / 0.6 3500 00 0 ± 0.05 Note C- Due to cabling the optical attenuation values can increase with max. 0.4 db/km 3

Macro Bending Performance Fibers Maximum attenuation increase for Bend Insensitive Single Mode fibers in db depending on turns and radius. Fibre-Type 00 5 mm 0 5 mm Turn 0 mm Turn 7.5 mm Turn 5 mm ) A 9/5 G.657A 65 0.0 0.05 F 9/5 G.657A 65 0.03 0. 0..0 I 9/5 G.657B3 65 0.03 0.0 0.08 5 0.5 0.45 Maximum attenuation increase for Bend Insensitive Multi Mode fibers in db depending on turns and radius. Fibre-Type 6.5/5 OM 00 37.5 mm 5 mm ) 7.5 mm 50/5 OM BI 0. 0.3 D 50/5 OM3 BI 0. 0.3 E 50/5 OM4 BI 0. 0.3 4

Mechanical, Physical and/or Environmental Characteristics Description: Tested according to: Requirement: According to Family specification: Storage Temperature Range IEC 60794---F -30 to +70 C IEC 60794--0 Installation Temperature Range -5 to +50 C Operating Temperature Range -5 to +55 C Strippability Secondary coating only 0 cm Secondary + primary coating 0 mm Bending radii for fibres and tight buffers Installation/operation For Bend Insensitive fibres >5 mm See Optical Characteristics Cable Water Blocking IEC 60794---F5 Pass Cable Min. Bend Operation (Long Term) IEC 60794---E 0 x Cable Diam. IEC 60794--0 Cable Min. Bend Installation (Short Term) IEC 60794---E6 0 x Cable Diam. Cable Max. Tensile Strength Operation (Short Term) IEC 60794---E See table with dimensions IEC 60794--0 Cable Max. Crush Resistance Operation (Long Term) Cable Max. Crush Resistance Installation (Short Term) IEC 60794---E3 3 kn/m 5 kn/m IEC 60794--0 Safety Testing standard Description / Value Reaction to fire IEC 6033- IEC 6033-3-4 Smoke density IEC 6034- Halogen acid gas content IEC 60754- Zero Degree of acidity of gases IEC 60754- Min. 4.3 ph IEC 60754- Max. 0 µs/mm 5

Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standardsstandard colours. If a cable needs to be fastened, constrictions must be avoided. To ease insertion certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. Indoor optical fibre cables have been designed for use inside buildings. Consequently they are not longitudinal watertight. It is advisable to cap the cable-ends during storage Options Breakout cables with Semi-Tight Buffered fibres. Mixed Fibre types. Non-standard cable constructions and colours 6