AVR Series Manual. Toroidal Isolation Power Conditioning Automatic Voltage Regulation Surge Protection

Similar documents
TOT AVR Series Manual

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

AVR Manual. Toroidal. Isolation. Power. Conditioning. Audio / Video Power Isolation Units with Automatic Voltage Regulation

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

AVR Series Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

POWER ISOLATION PRODUCTS BIT-5 BIT-15 BIT-20

WM AVR Series Manual. Input: 240V Output: 120V 8.0A

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

PS8 - II. Professional Power Sequencer. User s Manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

RETAIL Price List - Valid From June 2017

What s in the Box. Table of Contents

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

MODEL 805 USER MANUAL

PCM60A 100W MAX P.A. AMPLIFIER.

SUBWOOFER SYSTEM YST-MSW10

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

Neets Switching Relay - 2. Installation manual

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

MPF-1, Mains Power Filter User Manual

Thank you for your purchase of the Supa-Charger! Features Include:

EC Series. Safety Guide

R290DS Dual Source Power Amplifier Installation Manual

CANARY AUDIO CA-430. Vacuum Tube MM/MC Phono Preamplifier OWNER S MANUAL. Handcrafted in California MADE IN USA

CANARY AUDIO. Vacuum Tube Compact Disc Player CD-100 OWNER S MANUAL. Handcrafted in California MADE IN USA

Owner s Manual. MOON Series 320 S. Power Supply

SX2200 Series INSTALLATION INSTRUCTIONS. Electronic Systems Protection, Inc 8001 Knightdale Blvd. Suite 121 Knightdale NC 27545

FOR FURTHER INFORMATION CONTACT: Music Hall 108 Station Road Great Neck, NY Tel: Fax:

Blonde On Blonde OWNER S MANUAL SWR SCOTTSDALE, AZ USA

PS 680 SIX CHANNEL POWER SUPPLY WITH AUX MATRIX USER MANUAL

VOICE-ACTIVATED INTERCOM SYSTEM

Rack Mount Power Supplies

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

BUC-1 DIGITAL-TO DIGITAL CONVERTER

OWNER S MANUAL CD-2 V 1.3

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

English MP210. Français. Multimedia Speaker. User Manual. Please read this manual carefully before operating the Speaker System

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

Dual Channel Active Direct Box. Artcessories. User's Manual

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL

Network Camera. Quick Guide DC-B1203X. Powered by

THANK YOU! CR120H. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

Model HM-535 Power Supply Installation and Service Instructions

Installing the Cisco AS5400XM Universal Gateway

P125 Dual Source Power Amplifier Installation Manual

AUD-340 Installation Guide

TVA2.1 2-Channel Digital Amplifier Installation Manual

music hall a70.2 integrated amplifier music hall

APT20. User Manual.

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

7-Port Fast Charging Station NAP Instruction Manual Please read carefully before use and keep for future reference.

a35.2 integrated amplifier a35.2

actilib Library 2U Quick Start Guide

MC 11 EB-2 Power supply cabinet with external bus, AC version

DAB A d a pt e r 3+ Dear Customer,

CR6S Stereo Micro Crush

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

The PST-6. Owners Manual 1

AUD-220 Installation Guide

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

DPP 4004 / DPP V POWER SUPPLY - RACK UNIT

CANTEEN 6000 Portable Battery Pack NAP-30. Instruction Manual Please read carefully before use and keep for future reference.

Cantata m100 Amplifier

BS 217 DUAL CHANNEL MASTER STATION USER MANUAL

THANK YOU! Crush PiX 20L. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

EA014 Whiteboard Speakers. Manual and installation instructions

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

RTT98 VINTAGE TURNTABLE

CMSA-100 Manual. Cinema Media Server Automation

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

VIDAR OWNER S MANUAL STEREO OR MONO POWER AMP NOW, THAT S NOT A HINT THAT A THOR AMP IS COMING.

DUAL MONO POWER AMPLIFIER INSTRUCTIONS FOR USE

DMX Tool Splitter 1 to 5 User Manual

CPD SERIES OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier.

Installation Job Aid for VSP 4850GTS

Innovative Circuit Technology Ltd.

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

HSC-42. HDMI 4k2k Video Up/Down Scaler

music hall dac15.2 digital to analog converter INSTRUCTION MANUAL music hall

LTC 5121, LTC 5141 Series 2- and 4-Position Economical Sequential Switcher

CANARY AUDIO. Vacuum Tube Compact Disc Player CD-200 OWNER S MANUAL. Handcrafted in California MADE IN USA

Active UTP Transceiver Hub with Integral Isolated Camera Power

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

Monochrome Camera. Features. User manual

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

TECHCONNECT TC2-HDMI41 OWNERS MANUAL

Important Safety Instructions

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

Transcription:

Manual Toroidal Isolation Power Conditioning Automatic Voltage Regulation Surge Protection O Input: 240V Output: 120V 8.0A Toroidal Isolation Power Conditioning 19 Pro Series Rack Mount (RK) Faceplate O Input: 240V Output: 120V 8.0A Toroidal Isolation Power Conditioning 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

Table of Contents Table of Contents... Page 1 Important Safety Instructions... Page 2 Shipping Carton & Packing Material... Page 2 Placement and Ventilation... Page 2 Torus Power AVR Description... Page 3 Front Panel Display... Page 4 Rear Panel Connections and AVR Software... Page 5 AVR Software - Menu Selection... Page 6,7,8 Block Diagram - AVR System... Page 9 ayout... Page 9 Circuit Schematic - orth American Model... Page 10 Circuit Schematic - International Model... Page 10 Electrical Specifications - orth American Models... Page 11 Electrical Specifications - International Models... Page 11,12 Mechanical Specifications - orth American Models... Page 12 Mechanical Specifications - International Models... Page 12,13,14 Circuit Protection... Page 14 Thermal Protection... Page 14 Front Panel ayout... Page 14 Rear Panel ayout - orth American Models... Page 15 Rear Panel ayout - International Models... Page 16 Home Automation Interface... Page 17 Warranty... Page 17 Page 1

Important Safety Instructions CAUTIO! To reduce the risk of electric shock and fire, do not remove the cover of this device. There are no user serviceable parts inside. Please refer all servicing to licensed service technicians. CAUTIO! The international symbol of a lightning bolt inside a triangle is intended to alert the user to uninsulated dangerous voltage within the device s enclosure. The international symbol of an exclamation point inside a triangle is intended to alert the user to the presence of important operating, maintenance and servicing information in the manual accompanying the device. CAUTIO! To prevent electrical shock, match wide blade of plug to wide slot, fully insert. CAUTIO! To reduce the risk of electrical shock, do not expose this equipment to rain or moisture. 1. Read Instructions All safety and operating instructions should be read before operating the device. 2. Retain Instructions The safety and operating instructions should be retained for future reference. 3. Heed Warnings All warnings on the device and in the operating instructions should be adhered to. 4. Follow Instructions All operating and safety instructions should be followed. 5. Water & Moisture The device should never be used in, on or near water for risk of fatal shock. 6. Ventilation The device should always be located in such a way that it maintains proper ventilation. It should never be placed in a built-in installation or anywhere that may impede the flow of air through its ventilation slots. 7. Heat ever locate the device near heat sources such as radiators, floor registers, stoves or other heat-generating devices. 8. Power Cord Protection Power cables should be routed so they are not likely to be stepped on or crushed by items placed on them or against them. Special attention should be paid to areas where the plug enters a socket or fused strip and where the cord exits the device. 12. Damage Requiring Service The device should be serviced by licensed technicians when: The plug or power supply cord has been damaged. Objects have fallen or liquid has spilled inside the device. The device has been exposed to moisture. The device does not appear to be operating properly or exhibits a marked change in performance. The device has been dropped or the enclosure becomes damaged. 13. Do not position the equipment so that it is difficult to operate the disconnecting device (power cord). 14. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 15. The power switch should be in the off position when connecting or disconnecting equipment from a Torus Power unit. 16. CAUTIO Some units can be very heavy, please use safe practices when lifting. 9. Periods Of on-use The device should be unplugged when not being used for extended periods. 10. Dangerous Entry Care should be taken that no foreign objects or liquids fall or are spilled inside the device. 11. Service The device should always be serviced by licensed technicians. Only replacement parts specified by the manufacturer should be used. The use of unauthorized substitutions may result in fire, shock, or other hazards. Shipping Carton & Packing Material Please keep the original shipping box and all packing material. This will ensure the unit is protected in future transport. In the unlikely event you have a problem and must return it for service you must use the original packing material. Ship the unit only in the original packing material, as the unit is not insurable by carriers otherwise. Placement & Ventilation Torus power PIUs (Power Isolation Units) are extremely efficient yet very high power devices, and must be adequately cooled. PIUs have ventilation slots on the base, side panels and on the cover. Maintain at least 1 distance from each of these surfaces to anything else. Should your installation conditions be constricted, additional forced air-cooling may be necessary. Do not install the unit directly above heat generating equipment. Maintain at least 6 behind the PIU for adequate wiring space. Page 2

Torus Power AVR Description Torus AVR Description The Torus Power AVR (Automatic Voltage Regulation) is a full-feature state-of-the-art power transformer, isolating and protecting your system. ike all Torus Power products, the AVR series provides true isolation (using massive toroidal transformers) and protects all connected equipment from the risk of severe power line surges using series-mode surge suppression. In addition, Torus AVR provides stable voltage to keep equipment running in the optimal range of 115VAC to 125VAC for any input voltage from 90V to 130VAC. (International units operate within nominal input voltage such as 220V, 230V, 240V; Torus AVR keeps them operating within a range of +/- 10V.) See table on Page 9 for more details. The Torus Power AVR series uses a micro-processor to monitor and control the power provided to connected components. The front panel display on the Torus Power AVR indicates input and output voltages, and displays output current, as well as displaying fault conditions. The Torus Power AVR is pre-programmed to power down the system when a high or low fault conditions occurs (user can over-ride). There are multiple interfaces built into the Torus Power AVR: 1) Ethernet interface with built-in web server allows any computer to view voltage and current readings and turn the AVR unit O or OFF. 2) RS-232 is provided for connection to media control systems. 3) Two DC triggers are provided. Connecting components and using the AVR Using the AVR is as simple as plugging in audio and video components to the outlets on the rear panel. The order and position in which you connect your components will not affect the performance of the AVR or your components. Connect the AVR to the wall outlet, and switch it on. Turn on the components individually. While the AVR has built-in software that can be accessed via the Ethernet connection, there is no need for you to use this software. The AVR system provides all the standard features, performance, and benefits out - of - the - box by simply plugging it in as described in this section. You can use the AVR software to monitor the voltage conditions via your computer, and for such additional features as being able to turn your system on/off remotely and change the duration of the display s backlight. Does your system need automatic voltage regulation? Under ideal conditions, when the supplied power line is stable and dependable, you may not need voltage regulation. In such an ideal situation, your equipment can operate within the normal tolerance of the line voltage. In reality, the power supplied to most areas is less than ideal due to outdated power grids. In most areas, the power regularly drops or rises beyond the acceptable range (in orth America +/ 5V, Europe/Asia/Australia +/- 10V). These voltage sags, brownouts, and surges can stress components and shorten equipment life. In the worst case, catastrophic events can destroy valuable equipment. In such real-world conditions, the Torus Power AVR can protect your equipment, and improve the quality and enjoyment of your audio and video experience. Page 3

Front Panel Display Front Panel The front panel display consists of a 2 line CD and 1 push button. Typical Display Press button to show IP address (if Internet connection is used). See section on AVR software for further information on the IP address. Voltage Faults If a high or low voltage condition exists for 30 seconds or more, a voltage fault is displayed and the system shuts down (unless over-ridden by the user). Display will Show or As the output power from the Torus Power AVR is shut down, all the connected components are turned off. The AVR power switch remains in the O position, although there is no power to the load. The connected equipment should be switched off. When the voltage has been restored to the normal operating range, the following procedure can be followed: The Torus Power AVR can be switched OFF and then O. Wait thirty seconds to verify the fault condition no longer exists. The connected equipment should be switched O individually. If the fault condition still exists, the AVR will require approximately 15 seconds to monitor the incoming voltage, and the system will shut down again. The user can program the AVR software to allow the system to remain O, in case of fault (see AVR software section for details). Page 4

Rear Panel Connections and AVR Software ESA Serial # Toronto, Canada www.toruspower.com O USER-SERVICEABE PARTS ISIDE Figure 1: AVR Rear Panel Connections Ethernet Allows access to the AVR and internal software. See AVR software section for more details. RS232 Allows access to automation and external control. See Home Automation Interface commands at end of manual. DC Trigger On/Off The AVR can be turned on and off by a 12 volt trigger input. Applying 12 volts turns on the AVR and removing the 12 volts turns it off. DC Fault Output The AVR provides a 12 volt fault output through a jack on the back panel. The output goes to 12 volts when a relay or voltage fault is detected. The maximum current that can be drawn from this output is 75mA. AVR Software AVR software is resident in the microprocessor on the internal control board. There are two methods to access the software. 1) Connect the AVR to the Ethernet port. Open a browser window on a PC that is connected to the same network through another Ethernet port. Enter AVR (or the IP address displayed on the CD) into the browser window. Press ETER and the software will open. 2) Use a three way hub, which is connected to an existing network. You then connect both PC and AVR to the same Hub. Open a browser window from the PC. Type AVR, (or the IP address displayed on the CD) into the browser window. Press ETER and the software will open. Username and Password The password is required to change the setup of the Torus unit. Username is admin This is factory set and cannot be changed. Password is avr This is the default password, and can be changed. In case you forget your password, the AVR can be restored to the factory default password avr by pressing and holding the button on the front panel for at least 10 seconds. Page 5

AVR Software - Menu Selections AVR Menu Selections AVR Status Switch Power Setup Email Configuration Set Password Torus Power Home (website) etwork Configuration Screen by screen description of software options To access AVR software, enter user name and password. User name: admin is factory set and cannot be changed. Default password: avr You can change your password. Select: Set Password AVR Status This screen indicates the overall status of the system, showing Voltage In, Voltage Out, and Current Out. It also reports if the system is functioning normally or whether there is a fault condition. AVR Power Control This screen allows O or OFF control of the AVR unit. Press SET button to implement your selection. Page 6

AVR Software - Menu Selections (continued) AVR Setup This screen allows the user to configure two AVR parameters. 1. Shutdown on ow or High line voltage The factory default is YES to shut down in case of fault conditions. Unselecting this button will override, and the AVR will remain O even if voltage drops or rises beyond the acceptable range. 2. CD Display. Always O is the default setting. If you don t want the display on all the time, you can select a time from 0 to 255 seconds. When you have made your selections, press SAVE SETUP. Email Fault Alert otification In the unlikely event your AVR experiences an issue, the AVR will shut down and send an email notification if this section is configured. After entering the configuration parameters use the Send Test Email button to confirm your settings are correct. Set Password If you wish to change the password, use this screen. In case your forget your new password, you can restore the AVR to factory default password by pressing the button on the front of the AVR unit and HODI it down for at least 10 seconds. The default password is avr. Page 7

AVR Software - Menu Selections (continued) Each AVR unit has a unique MAC Address which is factory assigned. The IP address assigned to the AVR is dynamically assigned and is displayed on this screen as well as on the front panel CD of the AVR. The AVR can be programmed through the web browser to automatically get an IP address from the network switch or router and this is the default setting and should work on most networks. Some networks require each PC or device to use a fixed IP address and the AVR also supports this option. otes: 1. The output current (Amps) displayed on the CD is the RMS reading of the load. It does not indicate the peak current loads. 2. There is a 20-second delay built into the AVR system, to prevent nuisance switching. The AVR will take approximately 20-seconds to change relay taps to switch to the proper output voltage setting. 3. orth American models (15A, 20A): Torus AVR will keep the output constant within the range of 115Volts to 125Volts, with an input voltage of 90V to 130V. Between 85V to 90V, and between 130V and 135V, the regulation will be reduced. 4. orth American BA models: Torus AVR will keep the output constant within the range of 115Volts to 125Volts, with an input voltage of 170V to 270V. Between 160V to 170V, and between 260V and 270V, the regulation will be reduced. 5. International models: Torus AVR will keep the output constant within the range of 240 ± 10Volts, with an input voltage of 170V to 270V. Between 160V to 170V, and between 260V and 270V, the regulation will be reduced. 6. A drop in the input voltage is normal when increasing the load on the Torus AVR. This is a result of the impedance of the power line, and is a function of the distance from the electrical panel. Switch On Delay Feature The Automatic Voltage Regulation (AVR) feature is designed to handle normal utility fluctuations to provide the connected equipment with an optimal voltage supply. It is common when utility power is restored after a blackout that the voltage supply is unstable for a few seconds. To further protect connected equipment your AVR is equipped with a start up delay feature. When the power switch is turned on or when the power switch is on and utility power is restored, power will not be connected to the output receptacles until the delay time has passed. Page 8

Block Diagram - AVR System Input Voltage Range V I Circuit Breaker Automatic Voltage Stabilizer Maintains stable Voltage Output as shown in table below regardless of input voltage swings Fault protection Web interface Front panel display 12 volt triggers Media control system option Toroidal Isolation Transformer Complete isolation of primary from secondary allows attenuation of noise from 2kHz to over 1MHz ow impedance - provides instantaneous power High Power capability ow Mechanical noise Surge Removal and Complete Protection Protects against surges and lightning strikes up to 6000V/3000A Series mode technology does not contaminate ground Hospital rade Duplex Receptacles Output Voltage Range V O TORUS Technical Features Micro-controller based switching system Reliable relays rated for 40A Model ominal Operable Input Input Range Output orth American 120V 85V - 135V 120V ± 5V orth American Balanced 240V 170V - 270V 120V ± 5V International 220V 150V - 250V 220V ± 10V International 220V 160V - 250V 230V ± 10V International 230V 160V - 260V 230V ± 10V International 240V 170V - 270V 240V ± 10V Toroidal Transformer Technologies arrow Bandwidth (BT) ow oise (OO) ow Inrush (IMI) ow Stray Fields (ostray) Triple round Screen (UST) Shock mounted oversized transformer o sacrificial MOVs o air core inductors to generate noise 6.0kV 4.0kV 2.0kV 0V -2.0kV 0us V(D3:1) Medical grade outlets Clean ground 40us 80us 120us 180us 200us V(R7:1) Time ayout ote: ayout drawing is provided for reference only, Torus Power AVR units have no user serviceable parts inside. Please return unit to manufacturer for repair and service when required. Page 9

Circuit Schematic - orth American Model (AVR 20) 120VAC P1 F1 20A S1 IE 11 PT2 V-I 17VA 12K 22K WHT BU RY BK YE RED OUT 4 AC I AW12 PCB2 REAY BOARD OUT OUT OUT 3 2 1 PCB1 REAY BOARD OUT OUT OUT 4 3 2 C1 AC OUT AC OUT C1 TAB 6 TAB 5 OUT 1 9 RED PT1 VOUT RETAIER BAD T1 20 20 WHT BK 14 BK 8 BR 7 BK 14B BK 6 VIO C2 C3 REAY REAY CARD #1 CARD #2 PCB3 MAI COTROER CT1 DISPAY O COTROER CARD CD1 PB1 CT1 PT-4 RED AC PT-5 YE AC AW12 PT-7 RY VI Monitor I npu t : Ou t pu t : PT-6 BU VI Monitor C1 240v 240v A1W6 10 A1W7 PCB COMM. BOARD PCB4 C1 ETHERET OUTPUT 120VAC A1W6 A1W7 IPUT 5 OR 4 RY 3 BU 2 YE 1A WHT 14A BK (J2) SURE PCB A4 (J1) 13A WHT J1 J2 J3 J4 A1W6 A1W7 A1W7 A1W6 J5 1 WHT 10 11 12 C 13C WHT 13 WHT AW12 13B R / YE AW12 Circuit Schematic - International Model (AVR 8 CE) IPUT 240VAC P1 A3W1 CB1 PT2 V-I 17VA IE 11 12k BK BU RY WHT YE RED OUT 4 AC I A3W2 PCB2 REAY BOARD OUT OUT OUT 3 2 1 PCB1 OUT OUT OUT 4 3 2 C1 AC OUT AC OUT C1 TAB 6 TAB 5 OUT 1 9 RED PT1 BK A1W11 VOUT RETAIER BAD T1 20 20 WHT A1W12 13 BK 8 BR C2 C3 REAY REAY CARD #1 CARD #2 MAI COTROER C1 CT1 DISPAY O I npu t : 240v COTROER CARD Ou t pu t : 240v CD1 PB1 CT1 AC PT-4 RED AC PT-5 YE VI Monitor PT-7 RY VI Monitor PT-6 BU PCB3 SPICE PCB COMM. BOARD PCB4 10 C1 ETHERET 14AW OUTPUT 240VAC 7 BK 6 VIO J1 J2 J3 J4 J5 IE 21 22k 5 OR 13A BK 230V 230V 4 RY 3 BU 2 YE SURE PCB (J2) A4 T1, 1 WHT (J1) 12A WHT C 10 12 WHT 11 12B R / YE 230V 230V 230V 8AW SPICE 14AW ote: Circuit schematic drawing is provided for reference only, Torus Power AVR units have no user serviceable parts inside. Please return unit to manufacturer for repair and service when required. Page 10

Electrical Specifications - orth American Models Model umber Input Voltage ominal Output Voltage ominal Input Fuses Maximum Available Output Current AVR 15 120VAC, 60Hz 1 x 15A 15A AVR 15 PUS (Operating Range 120VAC ± 5V 1 x 15A 15A AVR 20 85V to 135V) 1 x 20A 20A AVR 20 BA 1 x 10A 20A AVR 45 BA 240VAC, 60Hz 2 x 25A 45A AVR 60 BA (Operating Range 120VAC ± 5V 2 x 30A 60A AVR 75 BA 170V to 270V) 2 x 40A 75A AVR 90 BA 2 x 45A 90A Electrical Specifications - International Models Model umber AVR 4 CE Input Voltage ominal Output Voltage ominal Input Circuit Breaker (Fuses) Maximum Available Output Current 1 x 4A 4A AVR 8 CE 240VAC, 50/60Hz 1 x 8A 8A 220-240VAC ± 10V AVR 16 CE (Operating Range 1 x 16A 16A AVR 30 CE 170V to 270V) 2 x 30A (Fuses) 30A AVR 45 CE 2 x 45A (Fuses) 45A AVR 4 UK 1 x 4A 4A AVR 8 UK 240VAC, 50/60Hz 1 x 8A 8A 220-240VAC ± 10V AVR 16 UK (Operating Range 1 x 16A 16A AVR 30 UK 170V to 270V) 2 x 30A (Fuses) 30A AVR 45 UK 2 x 45A (Fuses) 45A AVR 4 AUS 1 x 4A 4A AVR 8 AUS 240VAC, 50/60Hz 1 x 8A 8A 220-240VAC ± 10V AVR 16 AUS (Operating Range 1 x 16A 16A AVR 30 AUS 170V to 270V) 2 x 30A (Fuses) 30A AVR 45 AUS 2 x 45A (Fuses) 45A AVR 4 EUTRIK 1 x 4A 4A AVR 8 EUTRIK 240VAC, 50/60Hz 1 x 8A 8A 220-240VAC ± 10V AVR 16 EUTRIK (Operating Range 1 x 16A 16A AVR 30 EUTRIK 170V to 270V) 2 x 30A (Fuses) 30A AVR 45 EUTRIK 2 x 45A (Fuses) 45A AVR 4 IEC 1 x 4A 4A AVR 8 IEC 240VAC, 50/60Hz 1 x 8A 8A 220-240VAC ± 10V AVR 16 IEC (Operating Range 1 x 16A 16A AVR 30 IEC 170V to 270V) 2 x 30A (Fuses) 30A AVR 45 IEC 2 x 45A (Fuses) 45A AVR 4 615R 1 x 4A 4A AVR 8 615R 240VAC, 50/60Hz 1 x 8A (Fuse) 8A 220-240VAC ± 10V AVR 16 620R (Operating Range 1 x 16A 16A AVR 30 620R 170V to 270V) 2 x 30A (Fuses) 30A AVR 45 620R 2 x 45A (Fuses) 45A Page 11

Electrical Specifications - International Models (Continued) Model umber AVR 15 JP AVR 20 JP Input Voltage ominal 100VAC, 50/60Hz (Operating Range 85V to 135V) 100VAC, 50/60Hz (Operating Range 85V to 135V) Output Voltage ominal Input Circuit Breaker (Fuses) Maximum Available Output Current 100VAC ± 5V 1 x 15A (Fuse) 15A 100VAC ± 5V 1 x 20A (Fuse) 20A Mechanical Specifications - orth American Models Model umber AVR 15 AVR 15 PUS AVR 20 AVR 20 BA Input Connector (Rear Panel) IEC 15A Inlet, EMA C14 IEC 20A Inlet, EMA C20 Output Connector (Rear Panel) 10 Medical rade Outlets, 15A 10 Medical rade Outlets, 15A 10 Medical rade Outlets, 20A ine Cord 5/15, 14AW-C13, 15A/125V 5/15, 12AW-C19, 20A/125V 5/20, 12AW-C19, 20A/125V 6/15, 14AW-C19, 15A/125V Size, mm (WxDxH) Size, inch (WxDxH) 483x483x102 19x19x4 483x483x203 19x19x8 Weight K(lb) Chassis Height 26 (57) 2U (3.50 ) 36.3 (80) 40(88) 40(88) AVR 45 BA 62.5(138) 18 Medical rade 483x559x249 30A/250V AVR 60 BA Outlets, 20A 10AW, 30A 19x22x9.8 EMA 6-30P 74.5(164) AVR 75 BA 24 Medical rade 483x660x249 88.5 (195) AVR 90 BA 50A/250V 2P3W Outlets, 20A 6AW, 50A 19x26x9.8 90.5 (200) 4U (7.00 ) 5U (8.75 ) Mechanical Specifications - International Models Model umber AVR 4 CE AVR 8 CE AVR 16 CE AVR 30 CE AVR 45 CE Input Connector (Rear Panel) IEC 15A Inlet, EMA C14 IEC 20A Inlet, EMA C20 30A/250V EMA 6-30P 50A/250V 2P3W Output Connector (Rear Panel) 16A/250V CE Socket (x4) 16A/250V CE Socket (x5) 16A/250V CE Socket (x8) 16A/250V CE Socket (x8) 16A/250V CE Socket (x12) ine Cord 10A/250VAC, 2.5M Plug: CEE 7/7 Connector: IEC-C13 16A/250VAC, 2.5M Plug: CEE 7/7 Connector: IEC-C19 10AW, 30A 6AW, 50A Size, mm (WxDxH) Size, inch (WxDxH) 483x483x102 19x19x4 483x483x203 19x19x8 483x559x249 19x22x9.8 483x660x249 19x26x9.8 Weight K(lb) Chassis Height 24.5(54) 2U (3.50 ) 38(84) 4U (7.00 ) 56(123) 5U (8.75 ) 85.5(188.5) 100(220) Page 12

Mechanical Specifications - International Models (Continued) Model umber AVR 4 UK AVR 8 UK AVR 16 UK AVR 30 UK AVR 45 UK AVR 4 AUS AVR 8 AUS AVR 16 AUS AVR 30 AUS AVR 45 AUS AVR 4 EUTRIK AVR 8 EUTRIK AVR 16 EUTRIK AVR 30 EUTRIK AVR 45 EUTRIK Input Connector (Rear Panel) IEC 15A Inlet, EMA C14 IEC 20A Inlet, EMA C20 30A/250V EMA 6-30P 50A/250V 2P3W IEC 15A Inlet, EMA C14 IEC 20A Inlet, EMA C20 30A/250V EMA 6-30P 50A/250V 2P3W IEC 15A Inlet, EMA C14 IEC 20A Inlet, EMA C20 30A/250V EMA 6-30P 50A/250V 2P3W Output Connector (Rear Panel) 13A/250V UK Socket (x3) 13A/250V UK Socket (x5) 13A/250V UK Socket (x7) 13A/250V UK Socket (x7) 13A/250V UK Socket (x8) 10A/250V AUS Socket (x3) 10A/250V AUS Socket (x5) 20A/250V AUS Socket (x7) 20A/250V AUS Socket (x7) 20A/250V AUS Socket (x8) 16A/250V EUTRIK Socket (x4) 16A/250V EUTRIK Socket (x8) 16A/250V EUTRIK Socket (x12) 16A/250V EUTRIK Socket(x16) ine Cord 10A/250VAC, 2.5M Plug: BS 1363 Connector: IEC-C13 13A/250VAC, 2.5M Plug: BS 1363 Connector: IEC-C19 10AW, 30A 6AW, 50A 10A/250VAC, 2.5M Plug: AS/ZS 3112:2000 Connector: IEC-C13 13A/250VAC, 2.5M Plug: BS 1363 Connector: IEC-C19 10AW, 30A 6AW, 50A 10A/250VAC, 2.5M 13A/250VAC, 2.5M 10AW, 30A 6AW, 50A Size, mm (WxDxH) Size, inch (WxDxH) 483x483x102 19x19x4 483x483x203 19x19x8 483x559x249 19x22x9.8 483x660x249 19x26x9.8 483x483x102 19x19x4 483x483x203 19x19x8 483x559x249 19x22x9.8 483x660x249 19x26x9.8 483x483x102 19x19x4 483x483x203 19x19x8 483x559x249 19x22x9.8 483x660x249 19x26x9.8 Weight K(lb) Chassis Height 24.5(54) 2U (3.50 ) 38(84) 4U (7.00 ) 56(123) 5U (8.75 ) 85.5(188.5) 100(220) 24.5(54) 2U (3.50 ) 38(84) 4U (7.00 ) 56(123) 5U (8.75 ) 85.5(188.5) 100(220) 24.5(54) 2U (3.50 ) 38(84) 4U (7.00 ) 56(123) 85.5(188.5) 5U (8.75 ) 100(220) AVR 4 IEC IEC 15A Inlet, EMA C14 10A/250V IEC Socket (x6) 10A/250VAC, 2.5M 483x483x102 19x19x4 24.5(54) 2U (3.50 ) AVR 8 IEC AVR 16 IEC AVR 30 IEC AVR 45 IEC IEC 15A Inlet, EMA C14 IEC 20A Inlet, EMA C20 30A/250V EMA 6-30P 50A/250V 2P3W 10A/250V IEC Socket (x8) 10A/250V IEC Socket (x8) 16A/250V IEC Socket (x4) 10A/250VAC, 2.5M 13A/250VAC, 2.5M 10AW, 30A 6AW, 50A 483x483x203 19x19x8 483x559x249 19x22x9.8 483x660x249 19x26x9.8 38(84) 4U (7.00 ) 56(123) 85.5(188.5) 5U (8.75 ) 100(220) Page 13

Mechanical Specifications - International Models (Continued) Model umber Input Connector (Rear Panel) Output Connector (Rear Panel) ine Cord Size, mm (WxDxH) Size, inch (WxDxH) Weight K(lb) Chassis Height AVR 4 615R IEC 15A Inlet, EMA C14 8 Medical rade Outlets, 15A 5/15, 14AW-C13, 2.5M 483x483x102 19x19x4 24.5(54) 2U (3.50 ) AVR 8 615R IEC 20A Inlet, EMA C20 10 Medical rade Outlets, 15A 5/15, 12AW-C19, 2.5M 483x483x203 19x19x8 38(84) 4U (7.00 ) AVR 16 620R AVR 30 620R IEC 20A Inlet, EMA C20 30A/250V EMA 6-30P 12 Medical rade Outlets, 20A 18 Medical rade Outlets, 20A 5/20, 12AW-C19, 2.5M 10AW, 30A 483x559x249 19x22x9.8 56(123) 85.5(188.5) 5U (8.75 ) AVR 45 620R 50A/250V 2P3W 24 Medical rade Outlets, 20A 6AW, 50A 483x660x249 19x26x9.8 100(220) AVR 15 JP IEC 15A Inlet, EMA C14 10 Medical rade Outlets, 15A 5/15, 14AW-C13, 15A/125V 483x483x102 19x19x4 26 (57) 2U (3.50 ) AVR 20 JP IEC 20A Inlet, EMA C20 10 Medical rade Outlets, 20A 5/20, 12AW-C19, 20A/125V 483x483x203 19x19x8 40(88) 4U (7.00 ) Circuit Protection The Front panel power switch is appropriately fused and hence it prevents excessive current from entering the PIU. Thermal Protection Torus Power PIU will shut down if internal unit temperature reached excessive levels. Typical Front Panel ayout - orth American and International Models 19 Pro Series Rack Mount (RK) Faceplate 17 Consumer Series (C) Faceplate available in Black (B) and Silver (S) Input: 240V Input: 240V O Output: 120V 8.0A O Output: 120V 8.0A Toroidal Isolation Power Conditioning Toroidal Isolation Power Conditioning CD Display Illuminated O/OFF Switch or Circuit Breaker Page 14

Rear Panel ayout - orth American Models DC Fault 20A Medical rade Outlet DC Trigger ESA Serial # Toronto, Canada www.toruspower.com Ethernet RS232 Input Fuse Accessory round Stud let O USER-SERVICEABE PARTS ISIDE Models: AVR 20 RK, AVR 20 CB, AVR 20 CS Balanced Models: AVR 20 BA RK, AVR 20 BA CB, AVR 20 BA CS 15A Medical rade Outlet O USER-SERVICEABE PARTS ISIDE Models: AVR 15 RK, AVR 15 CB, AVR 15 CS 20A Medical rade Outlet 1 Toronto, Canada www.toruspower.com 2 Output Fuses Input Fuses ESA Serial # FUSE FUSE 3 O USER-SERVICEABE PARTS ISIDE Balanced Models: AVR 45 BA RK, AVR 45 BA CB, AVR 45 BA CS AVR 60 BA RK, AVR 60 BA CB, AVR 60 BA CS 20A Medical rade Outlet 1 2 1 2 Toronto, Canada www.toruspower.com ESA Serial # 5 4 3 Output Fuses 3 4 5 1 to 5 = Circuits O USER-SERVICEABE PARTS ISIDE Balanced Models: AVR 75 BA RK, AVR 75 BA CB, AVR 75 BA CS AVR 90 BA RK, AVR 90 BA CB, AVR 90 BA CS Page 15

Rear Panel ayout - International Models 16A/250V Continental European Socket 16A/250V Continental European Socket Toronto, Canada www.toruspower.com O USER-SERVICEABE PARTS ISIDE Continental Europe 4A Models: AVR 4 CE RK, AVR 4 CE CB, AVR 4 CE CS 16A/250V Continental European Socket 1 O USER-SERVICEABE PARTS ISIDE Continental Europe 8A Models: AVR 8 CE RK, AVR 8 CE CB, AVR 8 CE CS AVR2 Series 16A/250V Continental European Socket 2 FUSE Input Fuses FUSE AVR2 Series Toronto, Canada www.toruspower.com 3 O USER-SERVICEABE PARTS ISIDE 1-3 = 15A CIRCUITS Continental Europe 30A Models: AVR 30 CE RK, AVR 30 CE CB, AVR 30 CE CS 13A/250V UK Socket O USER-SERVICEABE PARTS ISIDE Fault Trigger RS 232 Ethernet Toronto, Canada Continental Europe 16A Models: AVR 16 CE RK, AVR 16 CE CB, AVR 16 CE CS 13A/250V UK Socket Toronto, Canada www.toruspower.com 16A CIRCUIT O USER-SERVICEABE PARTS ISIDE United Kingdom 16A Models: AVR 16 UK RK, AVR 16 UK CB, AVR 16 UK CS 20A/250V AUS Socket O USER-SERVICEABE PARTS ISIDE United Kingdom 8A Models: AVR 8 UK RK, AVR 8 UK CB, AVR 8 UK CS Fault Trigger RS 232 Ethernet 10A/250V AUS Socket Toronto, Canada Toronto, Canada www.toruspower.com 16A CIRCUIT O USER-SERVICEABE PARTS ISIDE Australian 16A Models: AVR 16 AUS RK, AVR 16 AUS CB, AVR 16 AUS CS O USER-SERVICEABE PARTS ISIDE Australian 8A Models: AVR 8 AUS RK, AVR 8 AUS CB, AVR 8 AUS CS Page 16

Home Automation Interface through RS232 Serial Port Settings 9600 baud 8 data bits o parity Commands are terminated with the carriage return character (13 decimal). Command Description Response C0<CR> Turn power OFF OK<CR> C1<CR> Turn power O OK<CR> Other Commands ot supported ERROR<CR> Warranty Torus Power products are warranted to be free from manufacturing defects for five years from the original date of sale. This includes parts, labour and return shipping to the first registered owner and all subsequent registered owners. Warranty coverage is extended to applicable products registered or having proof-of-purchase (sales invoice, etc.). In the event of a defect or malfunction, Torus Power will remedy the problem by repair or replacement, as we deem necessary, to restore the product to full performance. This warranty is considered void if the defect, malfunction or failure of the product or any component part was caused by damage (not resulting from a defect or malfunction) or abuse while in the possession of the customer. Failure to fully comply with Torus Power operating instructions, voids the warranty. Page 17

Torus Power products are marketed worldwide through Plitron Manufacturing Inc. For sales contact: torussales@plitron.com Phone: 416-667-9914 Fax: 416-667-8928 Toll free: 1-800-754-8766 Technical inquiries: torustechnical@plitron.com Phone: 416-667-9914 Torus Power #8 601 Magnetic Drive Toronto, O M3J 3J2 Canada Specifications subject to change without notice. Torus Power 2015 Rev. 08/19/2015