LCp-100 Weight Indicator/Transmitter

Similar documents
DXp-10 and DXp-15 Weight Transmitter

Safe-Weigh Process Weighing System

DXP-40 FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

LCt-104 FEATURES HTU MODE FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

DTM Distributed Transmitter Monitor

Power and Performance for Weighing Applications

Micro Motion Model 7950 and Model 7951 Signal Converters

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Trident and Trident X2 Digital Process and Temperature Panel Meter

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Weighing Indicator. Features. Description. Applications

Kistler-Morse. Systems: KM to KM Signal Processing (inputs) Outputs Operator Interface. KM to PLC/DCS/PC

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

LCp-104 Weighing System Operator s Manual

EC Type-Approval Certificate

C500 Series Data Sheet

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

WEB TENSION TECHNOLOGY

IQ plus 800/810. Digital Weight Indicators Version 3.1. Installation Manual

Neon pr. ph/ ORP measurement. Applications. Description

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

LC0 DVP

Weight Indicator. Model Intuition 22i FEATURES APPLICATIONS DESCRIPTION OPTIONS CONFIGURATION

/8 DIN Universal Process Indicator

Simplified information where and how you want it.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Performs many operations, from batch weighing to field bus networking applications.

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

Gateway 1400 Reference Manual

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

High Voltage DC Meter

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Programmable Relay ZEN V2 Units

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LAUREL ELECTRONICS, INC.

Digital Indicator Solutions

P3-SCM. General Specifications

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

LBVR1718. Description. Features channel paperless recorder

4110 HART Level Encoder

HIGH-VOLTAGE DC METER

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Wall-/Pipe Mounted Universal Process Indicator

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

Thermo Scientific CM515 and HME900 Density Converter Electronics

PD765 TRIDENT. Trident Series Process & Temperature Meters.

UniPak UP448 Bridge Input Isolating Signal Conditioner

Level-Lance Model 5400A

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

Enhanced Programmable Logic Controller Gateway Specification and Technical Data

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PG AA Modbus RTU to SNMP Protocol Converter

SITRANS L Level instruments

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

60 Series. Weight-Based Indicators & Controllers

895/896M Frequency Output Math Modules

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

NAVIGATOR. Digital Weight Indicator. Completely Menu-Driven Set-up Navigation. Bulletin No. 330D. Cardinal Scale Model 225 Weight Indicator

DISOMAT T Weigh Transmitter

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

Indicators/Controllers

SX90 Process Controller

Transmitter WST 3 From prog. name W001A100. Technical Manual

DI-924MB. Thermocouple/Millivolt Input Module

8130 Remote Terminal Unit

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

PD Helios Strain Gauge, Load Cell & mv Meter. Strain gauge. Actual Size Digit

General Specifications

DI-932MB/DI-934MB. RTD/Resistance Input Module. Four RTD or Resistance Inputs

InteliLite MRS17 Click Here to Learn More

Industrial Power Supplies

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Industrial Power Supplies

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

CERTIFICATE of EU TYPE-APPROVAL

G303 RIO (REMOTE I/O) AND LOW END RTU

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

General Specifications

S-series Serial Interface

BLH. DXp-40 Interface Manual Allen-Bradley Remote I/O WEIGH SYSTEM TECHNOLOGY. TM014 Rev D 6/1/11 Doc 35105

Transcription:

Precision Force and Weight Measurement Technologies LCp-100 Weight Indicator/Transmitter Process Applications: Mix Tanks Blenders Reactors Product Description Hardware Features 1 Million Count Resolution, 20 Updates per Second High Resolution (16 Bit) Analog Output RS-422/485 Communication Port with ASCII, BLH Digi-System Plus Network, or Modbus RTU Protocol Expansion Slot for A-B Remote I/O, Modbus Plus, Profibus, or Future Fieldbus Optional Internal Modem for On-Line Service Safe-Weigh Software System Quick-Cal Set-Up Dynamic Digital Process Filtering The LCp-100 is a high performance weight indicator and transmitter with features and options focused on the requirements of precision, high-speed process and inventory weighing applications. It is compatible with all strain gage type load cells and is designed to easily connect to any PLC, DCS, or PC based process control system. Special design emphasis has been placed on simplicity, reliability, and expandability. Transmitter outputs offered include an RS-422/ 485 digital serial communication port, and 16 bit derived analog current output. Units are equipped with an expansion slot for installing a wide range of specialized digital interfaces such as A-B Remote l/o, Modbus Plus, or Fieldbus (in the future). The LCp-100 Safe-Weigh SoftwareTM System encompasses over 50 years of BLH application expertise. Plug-n-Weigh quick calibration and set-up procedures save time, money, and even field service calls. Online diagnostics continuously monitor weigh system performance and alert service personnel to potential problems, before they happen. Real Time System & Loop Diagnostics BLH Electronics, Inc. An ISO 9001 Registered Company

Why Do We Call the LCp-100 an EXPERT? Plug-n-Weigh Technology Plug-n-Weigh technology minimizes start-up time while significantly reducing the operator learning curve. Intuitive configuration menus, self-configuration of many set-up parameters, and simple push-button type digital calibration combine together to make the LCp100 easy to install and operate. Safe-Weigh Software System Safe-Weigh Software System advantages include Expert System Diagnostics, Dynamic Digital Filtering, and a wide range of proven DCS/PLC connectivity options. Expert System Diagnostics generate on-line preventative maintenance signals, which quickly identify potential electrical/mechanical failures. Dynamic Digital Filtering ensures stable weight data and precise, repeatable setpoint control in dynamic process environments. Communications and Interfacing LCp-100 instruments are designed for fast, easy interfacing with virtually any PLC or DCS system. LCp-100 instruments are the first weight transmitters available with Schneider Automation, Modbus Plus Network communication. Also, as a charter member of the Allen-Bradley Enabled program, BLH offers Remote l/o capability in all LCp products. Other easy digital interfaces are available for Seimens Profibus, Honeywell TDC 3000, GE series 90 PLC s, and Fisher Rosemount (Provox). For cost effective local area network applications, units may be ordered with BLH Digi-System Plus protocol for communication to a PLC or DCS via an LCp-400 Gate-Weigh controller. CE Marking The CE mark certifies that LCp-100 instruments conform to international applicable safety, electrical, and emission/susceptibility standards.

Typical LCp-100 Weighing Application On-Line System Diagnostics LCp-100 diagnostics provide easy access to critical operating system data. Front panel display alarm/ status annunciators A1-A8 can be configured to represent communication errors, setpoint status, analog output errors, Allen-Bradley Remote l/o or Modbus Plus status, and modem status. Information related to any active annunciator is transmitted to a host PLC or DCS via the communication interface. Field Service Modem Connection Units equipped with the optional internal modem connect directly with the BLH field service department. Service Engineers diagnose and correct (if possible) system errors right over the phone line. Service Engineers also can evaluate internal memory locations to detect improper set-ups, hardware failures, and can upload software revisions as they become available. The LCp-100 modem is a V.22 bis data modem compatible with CCITT V.22 bis (2400 bps), Bell 212A (1200 bps), and Bell 103 (300 bps). Modem interfaces directly with BLH Field Service Engineer

LCp-100 Specifications Performance Resolution Displayed Resolution Conversion Speed Displayed Sensitivity Noise Full Scale Range Dead Load Range Input Impedance Excitation Voltage Linearity Software Filter Step Response Temp Coefficient Zero Temp Coefficient Span 1048576 total counts 700,000 counts 50 msec 0.05 uv per count 0.4 uv per count (min. filt. setting) 3.5 mv/v 100% full scale 10 m-ohms min 10 Vdc @ 250 ma +/-0.0015% full scale multi-variable up to 10,000 msec one conversion +/-2ppm/ C +/-7ppm/ C Remote Digital Inputs (Optically Isolated) (Contact closure or do logic compatible) Closed (Momentary) logic low Open logic high Cable Length 100 feet max. Communications (Standard) Serial RS-422/485 full or half duplex BLH Digi-System Plus Network, ASCII, Provox, or Modbus protocols odd, even or no parity- selectable Baud Rates 300, 1200, 2400, 4800, 9600, or 19200 Addressing 0-99 Environment Operating Temperature -10 to 55 C (15 to 131 F) Storage Temperature -20 to 85 C (-5 to 185 F) Humidity 5 to 90% rh non-condensing Voltage 117/230 Vac +/-15% @ 50/60 Hz Power 15 watts max Special Interfaces (Optional) Allen-Bradley Remote l/o -1/4 Logical Rack Modbus RTU slave Modbus Plus peer-to-peer (supports global data) Profibus slave Enclosure Dimensions (std) NEMA 4/4X, 12 (opt) Materials Aluminum Case & Bezel Display Type Active Digits Analog Output (Optional) Conversion Current Selectable 4.63 x 8.40 x 6.5 in. HWD 8.5 x 13.5 x 10.45 in. HWD overlay meets 94V-0 rating high intensity cobalt green vacuum fluorescent 7 digit alpha numeric.59" high for weight: 8 digit alphanumeric.39" high for status 16 bit D-A 4-20 ma or 0-20 ma - 600 ohm max., 0-24 ma - 500 ohm max. Internal Service Modem (Optional) Baud Rate 2400: Bell 212/103 compatible Availability U.S.A. and Canada only Approvals/CE Marking FM (Factory Mutual) 3611 CSA C22.2 (all applicable sections) IEC 801-2 ESD susceptibility, category B IEC 801-3 radiated electromagnetic field, cat. A IEC 801-4 conducted line transients, cat. B EMI Emissions FCC part 15 subpart B. Class A Canadian Dept. of communication, Class A EN 5501 Group 1, Class A IEC 1010-1/EN61010-1 Electrical Safety EN50082-1 1992 Susceptibility: subparts 801,2,3, & 4 EN55011 Emissions: Equipment Class I, Group A BLH is continually seeking to improve product quality and performance. Specifications may change accordingly. PLC and Allen-Bradley are trademarks of Allen-Bradley Co, Inc. Modbus is a trademark of Schneider Automation. Profibus is a trademark of Seimens. PD 674 February 1999

Ordering Specification Code LCP-100- [M]-[AP]-[C]-[B]-[M] Indicating Weight Transmitter LCP-200- [M]-[AP]-[C]-[B]-[M] Indicating Weight Transmitter with Discrete I/O & Rate Functions LCP-100 LCP-200 [M] MOUNTING [1] NEMA 4X PANEL MOUNT STD STD [2] #1 & FM/CSA DIV. 2 APPROVAL (CLI, DIV2, GRP A-D,FG) [5] NEMA 4X STAINLESS STEEL WALL MOUNT ENCLOSURE [6] #5 & FM/CSA DIV. 2 APPROVAL (CLI,II, DIV2, GRP A-D,FG) [7] #5 with MODEL 306 INTERNAL SUMMING BOARD [8] #6 with MODEL 306 INTERNAL SUMMING BOARD [13] #6 with TYPE Y PURGE SUITABLE FOR DIV. 1 AREAS [15] NEMA 4/7/9 Ex Enclosure(CL l,ll,lll, DIV1,GRP BCDEFG) [A] EXPANSION SLOT A [1] NONE STD STD [3] MODBUS PLUS [4] ALLEN BRADLEY REMOTE I/O [5] PROFIBUS DP [P] PROCESS INPUTS & OUTPUTS [1] REMOTE FUNCTION INPUT (zero, gross/net, tare, print) STD STD [2] #1 and ANALOG CURRENT OUTPUT [9] #1 and ANALOG CURRENT OUTPUT,BIPOLAR DIRECTION, 100 UPDATES/SECOND, UNITS IN LB, KG, PLI, N, N/M [C] COMMUNICATION [1] RS-485/422 W/ ASCII PROTOCOL & DIGISYSTEM + STD STD [2] #1 and MODBUS RTU PROTOCOL [3] #1 & PROVOX PROTOCOL (includes 20mA serial converter) [B] EXPANSION SLOT B [1] None STD N/A [2] 8 Open Collector DC Outputs N/A STD [3] 8 Solid State Relay Outputs N/A [M] MODEM/ON-LINE SERVICE [1] NONE STD STD [2] MODEM with 90 DAYS ON-LINE SERVICE Weigh-View Software Kit ( 471297)