IBM TotalStorage DS300 and DS400 Quick Installation Guide

Similar documents
IBM TotalStorage DS300 and DS400 Quick Installation Guide

IBM TotalStorage DS4000 Fibre Channel and Serial ATA Intermix Premium Feature. Installation Overview

System Storage DS3950 Quick Start Guide

GB of cache memory per controller to DS4800 controllers with 8 GB of cache memory per controller.

SAN16B-2 Implementation

IBM TotalStorage NAS Gateway 300 Model G27. Quick Start Instructions

IBM System Storage DS4700 Express Storage Subsystem Fibre Channel Cabling Guide

VTRAK E-Class/J-Class Quick Start Guide

IBM TotalStorage NAS 200 Model 25T. Quick Start Instructions

Installing IBM System Storage Productivity Center

IBM TotalStorage DS4500 Fibre Channel Storage Subsystem Cabling Guide

VTRAK E610f, J610s Quick Start Guide

[ Quick Start Guide ]

N3240 Installation and Setup Instructions

Configuring the DS8000 (using DS CLI) for use with the TotalStorage Productivity Center Replication Manager

Installing the Microsoft Hyper-V Failover Cluster on N series

Rack Installation Instructions

iscsi Storage Appliance Getting Started Guide

Oracle Enterprise Manager Ops Center E Introduction

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

IBM Shared Disk Clustering. Hardware Reference

Installation and User's Guide

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

Here is Your Customized Document

Installing VMware vsphere 5.1 Components

N3220 Installation and Setup Instructions

IBM Networking OS. BBI Quick Guide. for the EN2092 1Gb Ethernet Scalable Switch, Second edition (replaces 88Y7949)

Deployment Guide: Routing Mode with No DMZ

Backup and Recovery of RDM A White Paper

IBM PCI Hot Plug Services User Guide

Installation Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

Version S Cincinnati, Suite 105 Tulsa, OK (918) Fax (918)

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA USA. November v1.0

NPort Express, NPort Server Family, Async Server Windows XP Driver Installation Guide. Second Edition, December 2001

N6000 Series Filer Installation and Setup Instructions

Device Manager. Managing Devices CHAPTER

Installing and Using VeritiLink Software Quick Reference Card

American Dynamics RAID Storage System iscsi Software User s Manual

[ Quick Start Guide ]

QLogic iscsi Boot for HP FlexFabric Adapters User Guide

IBM ThinkPad 770 Setup Guide

Lenovo XClarity Administrator Quick Start Guide Configuring Servers Using Lenovo XClarity Administrator

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

Configuring Cisco UCS Server Pools and Policies

Upgrading from TrafficShield 3.2.X to Application Security Module 9.2.3

Host Attachment Guide

SonicWALL Security Appliances. SonicWALL SSL-VPN 200 Getting Started Guide

EXN4000 Storage Expansion Unit Installation and Setup Instructions

Dell PowerVault MD3600i and MD3620i Storage Arrays. Deployment Guide

Terminology. This document uses the following terms:

Business Internet Video Camera with Audio

N3150 Installation and Setup Instructions

IBM ThinkPad 600 Setup Guide

Deploying the 8TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R740 and SCv3020

Deploying the 60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020

Configuring the SMA 500v Virtual Appliance

Deploy the ExtraHop Trace 6150 Appliance

Configuring Milestone XProtect Corporate Video Management System with NetApp E-Series Storage Proof-of-Concept Implementation Guide

Installing the IBM ServeRAID Cluster Solution

Addonics T E C H N O L O G I E S. Addonics iscsi Subsystem. Model: ISC8P2G

Updating Broadcom Network Adapter Firmware with RDM A White Paper

SteelCentral AppResponse 11 Virtual Edition Installation Guide

F5 WANJet 200. Quick Start Guide. Quick Start Overview

Analyzer Quick Start Guide

Network and storage settings of ES NAS high-availability network storage services

EMC Celerra NS-120 System (Dual Blade) Installation Guide

Extended Search Administration

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

IBM Client Security Solutions. Client Security Software Version 1.0 Administrator's Guide

Version 1.0 Last updated: August 11, 2017 Author: Albert Wang & Mike Hull

EMC Celerra NS-120 System (Single Blade) Installation Guide

Oracle VM. Getting Started Guide for Release 3.2

Creating an IBM API Management Version 2.0 environment

VTRAK S3000 Quick Start Guide

Citrix XenServer with Dell SC Series Storage Configuration and Deployment

Next Generation Control - Wireless Network

Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020

ScopTEL TM IP PBX Software. DNS Server Configuration Wizard

ServeRAID M5025 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide

IBM Exam C IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ]

Network and storage settings of ES NAS high-availability network storage services

Filtered SINGLEstream Link Aggregation Tap. User s Guide. FSS-1000 Series (BT, SX, LX) FSS-2000 Series (BT, SX, LX, BT/SX, BT/LX)

Corinex Communications Corp. assumes no responsibility or liability for any errors or inaccuracies that may appear in this book.

Deploy the ExtraHop Discover 3000, 6000, or 8000 Appliances

Setup and Configuration

RealPresence Access Director System Administrator s Guide

Deploy the ExtraHop Discover 3100, 6100, 8100, or 9100 Appliances

Print Server. Quick Configuration Guide. Network Connectivity for Printers

4. Web-based Switch Configuration

ServeRAID M1015 SAS/SATA Controller for System x IBM System x at-a-glance guide

Kaseya 2. User Guide. Version 1.0

ThinkPad Dock, ThinkPad Dock II. User s Guide

Cluster Management Workflows for OnCommand System Manager

IBM System Storage SAN24B-4 Express

xseries Systems Management IBM Diagnostic Data Capture 1.0 Installation and User s Guide

ProSafe Plus Switch Utility

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

Dell PowerVault MD3800i and MD3820i Series Storage Arrays Deployment Guide

Configuring Server Boot

Cascade Sensor Installation Guide. Version 8.2 March 2009

Transcription:

IBM TotalStorage DS300 and DS400 Quick Installation Guide Before using this information and the product it supports, read the IBM Statement of Limited Warranty in the IBM TotalStorage DS300 and DS400 Warranty and Support Information document on the IBM Documentation CD. Obtaining the documentation from the IBM Support Web site All IBM TotalStorage documentation that is referred to in this Quick Installation Guide is on the IBM Support Web site or on the IBM Documentation CD that comes with the storage subsystem. To get to the latest documentation and technical updates on the IBM Support Web site, complete the following steps: 1. Go to http://www.ibm.com/pc/support/. 2. In the Browse by topic section, click Publications. 3. On the Publications page, in the Brand field, select Servers. 4. In the Family field, select TotalStorage DS300 or TotalStorage DS400. 5. Click Continue. Before you begin, you should have a plan for how you want to install this storage subsystem into a storage network. This plan should allow for the data servers, management station, host bus adapters, switches, and other equipment. See Chapter 2 (for TotalStorage DS300) or Chapter 5 (for TotalStorage DS400) of the IBM TotalStorage DS300 and DS400 Dual Controller Hardware Installation and User s Guide for more information. Installing the hardware Complete the following steps to install the hardware: 1. Remove all packing materials. 2. Install the rails and the DS300 or DS400 storage subsystem into a standard EIA 19-inch rack (see the printed Rack Installation Instructions that comes with the storage subsystem for instructions). 3. Install the front bezel on the DS300 or DS400 storage subsystem (see Chapter 10 of the Dual Controller Hardware Installation and User s Guide for instructions). 4. Install hard disk drives in the DS300 or DS400 storage subsystem (see Chapter 10 of the Dual Controller Hardware Installation and User s Guide for instructions). 5. Connect the power cables that come with the DS300 or DS400 storage subsystem to the power distribution unit (see Power cabling in Chapter 9 of the Dual Controller Hardware Installation and User s Guide for instructions). 6. Install the small-form-factor pluggable (SFP) modules and connect the Ethernet and Fibre Channel cables. For instructions, see Chapter 3 (for DS300) or Chapter 7 (for DS400) of the Dual Controller Hardware Installation and User s Guide. 7. Turn on the storage subsystem (see Turning the storage subsystem on and off in Chapter 9 of the Dual Controller Hardware Installation and User s Guide for instructions). Setting up the controller defaults Complete the following steps to set up the RAID controller defaults: 1. After turning on the storage subsystem, wait until the green controller ready LED is lit; then, from a management station, open a Telnet session to IP address 192.168.70.123. For the location and a description of the LED, see the storage subsystem rear view section in Chapter 4 (for DS300) or Chapter 8 (for DS400) of the Dual Controller Hardware Installation and User s Guide.

2. Change to administrator mode by typing administrator, admin, or ad and pressing Enter. 3. When prompted for a password, type passw0rd (all lowercase letters with a zero, not O, in passw0rd) and press Enter. 4. For Controller A only: At the DS300 or DS400 prompt, type setup. The Setup wizard prompts you to enter the values for the parameters that are required to configure the system to connect to a local network. You can also use the three commands that are described in the following table: Table 1. Setup wizard commands Command Function abort Quit the Setup wizard without saving changes back Go to the previous parameter help Describes the current parameter values If a parameter has a default value, the value appears in square brackets ( [ ] ). Some parameters require an arbitrary string, in which case the commands back and abort cannot be used. In these cases, enclose the value that you type in double-quotation marks ( ) so that the value is accepted, even if it is the same word as a command. Use the following information to assign values for the parameters: hostname Type the name that you want to use for the system. Type back to repeat this prompt. domain name Type the domain to which the system belongs. SAN name Type the Storage Area Network (SAN) to which the system belongs. timezone Type the system time zone. system date Type the system date in the format hh:mm@day/month/year. define administrator password Define whether an administrator password is required. If a password is required, you are prompted for that password, which must be typed twice. Press Ctrl to leave the password unchanged. Press Enter twice to not require an administrator password. define operator password Define whether an operator password is required. dhcp Type yes if a DHCP server will be used to discover the system network values. Type no if a DHCP server will not be used. IP If you type yes, the wizard takes you to the Save new configuration parameter. If you type no, the wizard continues to prompt you for information about the main Ethernet interface of the system. address Type the IP address in x.x.x.x format. You can also define the netmask by typing its width after the IP address. Note: For the DS300 storage subsystem, the management interface must be in a separate network segment from your iscsi ports. 2

netmask Define the size of the netmask. Any of the common formats are accepted. Note: If you typed the netmask as part of the IP address in the previous prompt, this parameter is skipped. broadcast address Type the address to be used for broadcasts. Any of the common formats are accepted. default gateway Type the name or IP address of a router to which packets for destinations that do not have routes defined for them in the system, are sent. Type no to clear the default gateway. DNS servers Type the IP addresses of up to three systems that will act as DNS servers. Type no to clear the list of DNS servers. save new configuration When the Setup wizard has finished, the system is configured, but the new configuration is not saved immediately in non-volatile memory. Type yes to save the configuration immediately, or type no to defer saving the configuration. You can also type save to save the configuration. Finished? Type yes to apply the values you have entered, or type no to return to the first parameter and change the values you have entered. 5. If you changed the management IP address in step 4 on page 2, establish a Telnet session to the new IP address. 6. Change the Controller B management port network parameters by typing interface manage eth0[b] and pressing Enter. Then, type the following: ip IPaddress netmask netmask broadcast broadcast Installing IBM ServeRAID Manager and adding a ServeRAID agent Complete the following steps to install the IBM ServeRAID Manager program and add a ServeRAID agent for the storage subsystem: 1. Install the ServeRAID Manager program on the management station, using the ServeRAID Application CD that comes with the DS300 or DS400 storage subsystem (see the IBM TotalStorage DS300 and DS400 Dual Controller Software Installation Guide on the IBM Support Web site for help with installing ServeRAID Manager). 2. Start the ServeRAID Manager program; then, complete the following steps to add a management station object and a ServeRAID agent for the storage subsystem: a. To add a management station object, right-click Networked Storage in the ServeRAID Manager interface; then, select Add Management Station (see Adding a remote system object in the ServeRAID Manager online help for more information about adding a management station). b. To add a ServeRAID agent, right-click the management station object in the interface and select Add agent. Use the IP address that you assigned to the storage subsystem in step 4 on page 2. (See Adding a Management Station Agent Object in the ServeRAID Manager online help for more information about adding an agent.) Note: Only the IP address of Controller A or Controller B needs to be added as a ServeRAID agent. 3

Installing the controller firmware Updates are made to the RAID controller firmware occasionally to improve the function or performance of the RAID controller in the storage subsystem. Obtain the latest firmware before proceeding to the next steps (see the Dual Controller Software Installation Guide on the IBM Support Web site for information about how to locate and download the latest firmware). Setting IP addresses for DS300 type 1701 iscsi ports Complete the following steps to set the IP addresses for the iscsi ports on the DS300 type 1701 storage subsystem: 1. If you did not open a Telnet session in step 5 on page 3, open a Telnet session now, using the management IP address that you set in step 4 on page 2. If you also changed the password in step 4, use the new password to log in. 2. Type the following commands to set the IP addresses for each of the iscsi ports (eth2 and eth3): interface manage eth2[a] ip IPaddress netmask netmask Broadcast broadcast interface manage eth2[b] ip IPaddress netmask netmask Broadcast broadcast interface manage eth3[a] ip IPaddress netmask netmask Broadcast broadcast interface manage eth3[b] ip IPaddress netmask netmask Broadcast broadcast where IPaddress is the IP address that you want to use for that port, and netmask is the management network subnet address. See the IBM TotalStorage DS300 Problem Determination Guide or IBM TotalStorage DS400 Problem Determination Guide on the IBM Support Web site for a list of all the available commands. Configuring the RAID device in ServeRAID Manager Complete the following steps to create a RAID array and configure the access control list for the logical drive: 1. In the ServeRAID Manager interface on the management station, in the pane on the right, click the agent (which is displayed as a controller device) that you created in step 2b on page 3 in Installing IBM ServeRAID Manager and adding a ServeRAID agent on page 3. The interface displays the Enclosure View pane for the storage subsystem. 2. In the upper right corner of the Enclosure View pane, click the disk icon. The array configuration menu is displayed. 3. In the array configuration menu, select Create logical drive in a new array; then, click Next. 4. Complete the following steps to select the drives you want in the array (see the Creating arrays and hot-spare drives section in the ServeRAID Manager online help for more information): a. Press Ctrl and click each drive that you want in the array. b. Click the single arrow to move the drives to the left pane. c. If you need to create more than one array, click Create New Array at the top of the left pane and repeat steps 4a and 4b. d. When you are finished, click Next. 5. Select the logical drive name, size, and preferred controller that you want; then, if you are finished, click Next. If you want to create more than one logical drive or change the preferred controller, complete the following steps (see the Creating logical drives section in the ServeRAID Manager online help for more information): 4 a. Change the default size to less than the full capacity. b. Select the preferred controller from the Controller menu. c. Click Create new logical drive at the bottom of the pane. d. Select the next logical drive name and size. e. When you have selected all the names and sizes you need, click Next.

6. For a TotalStorage DS400, continue to step 7; otherwise, select the authentication options for the logical drive. 7. Complete the following steps to configure the access control list for the logical drive (see the Defining initiator information section in the ServeRAID Manager online help for more information): a. Select Add or Discover new initiators (DS400 only). A window opens containing the first entry in the access control list. b. In the top line in the window, type or select from the menu (if Discover new initiators is selected) one of the following choices: v The world wide port name (WWPN) for the Fibre Channel host bus adapter (HBA) that the logical unit number (LUN) will be bound to v The iscsi Qualified Name (IQN) for the iscsi initiator c. In the second line in the window, type the alias that you want to use for the entity in the top line. d. Click OK to accept the information that you entered. A new access-list-entry window opens. Repeat steps 7b through 7d for each entry in the access list. When you are finished, click Cancel. 8. Click Next. The mapping pane is displayed. The aliases in the access control list are displayed in tabs in the right pane; the logical drives are displayed in the left pane. 9. Complete the following steps to associate one or more logical drives with an alias (see the Assigning logical drives to initiators section in the ServeRAID Manager online help for more information): a. Highlight the logical drive. b. Click the alias that you want to associate it with. c. Click the single arrow in the middle pane to move the drive to the alias, or click the double arrow in the middle pane to move all the drives to the alias. The drive moves to a point beneath the alias in the right pane. d. Click Next. e. Click Accept to apply the changes, or click Back to return to the mapping pane to make changes or to make more associations. After you complete the associations, the Enclosure View pane is displayed again, and the LUN is ready for access. 5

Fourth Edition (February 2005) Printed in Singapore IBM, ServeRAID, and TotalStorage are trademarks of the International Business Machines Corporation in the United States, other countries, or both. Copyright International Business Machines Corporation 2004, 2005. All rights reserved. US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. (1P) P/N: 31R1061