Type Quickstart (from device Version 2)

Similar documents
Type Flow Transmitter / Pulse divider Durchflusstransmitter / Impulsteiler Transmetteur de débit / Diviseur d impulsions

Type Quickstart

Type MS04. Redox potential sensor cube. Operating Instructions

Type ME43. Quickstart

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

8032 / SE32. Operating Instructions. Bedienungsanleitung Manuel d utilisation

CPCI-PS24 24V-Power Supply

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

Type 8025 UNIVERSAL. Operating Instructions. Bedienungsanleitung Manuel d utilisation. Flow transmitter Durchfluss-Transmitter Transmetteur de débit

BVS 16 ATEX E088 X, IECEx BVS X. Operating Instructions

Type 8791 Positioner SideControl BASIC. Quickstart. English / Deutsch / Français

Types SE35 BATCH. Quickstart. Batch controller Dosiergerät Contrôleur de dosage. English / Deutsch / Français

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Type SE35 BATCH

Operating instructions. Switching amplifier DN0210 DN / / 2015

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-...

Operating instructions. Standstill monitor A / / 2011

The identified danger could cause physical and property damage.

GS202 Encoder Switch

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

V E5B Snap-in I/O Module

V E62B Snap-in I/O Module

V E1B Snap-in I/O Module

MC 11 EB-2 Power supply cabinet with external bus, AC version

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Operating instructions. Speed monitor D / / 2014

Positioner CMSX-...-C-U-F1-...

User Manual HMI Linkbox HL01 DP/MPI

OPLC Installation Guide

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

SolConeX extra-low voltage flange socket

Vision OPLC V TR6/V350-J-TR6

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

High Power Electronic Gear Installation and operation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Operating Instructions VEGAMET 381

V E2B Snap-in I/O Module

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

Intrinsically safe batch controller Batching Master 110i

Installation manual plugs and connectors with screw connection (16/32 A)

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

Vision OPLC. V T38 Installation Guide. General Description

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

TEMPERIX S Clamp. FAFNIR GmbH Schnackenburgallee 149 c Hamburg Germany

This guide provides basic information for Unitronics controller model V T2.

2-PHASE STEPPING MOTOR DRIVER FE Z4 TRANSFER

Inductive sensor NI3-EG08K-Y1-H1341

Instruction Manual. T3110 T3110L T3110Ex

V E2B Snap-in I/O Module

Type Operating Instructions

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MDM 011-Z1 Regen Resistor

V E1B Snap-in I/O Module

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Safety Instructions Cerabar S PMP71, PMP75

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

User safety and equipment protection guidelines

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Analog Input Installation Manual

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

High Speed Remote I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Inductive sensor BI1.5-EG08-Y1-H1341

Installation instructions Inclination sensor EC2019 EC / / 2013

Analog Monitor Installation Manual

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Temperature Switches

Type 8692, Positioner and process controller Positioner und Prozessregler Positionneur et régulateur de process. Quickstart

8692, 8693 REV.2. Positioner / Process Controller Positioner / Prozessregler Positionneur / Régulateur de process. Quickstart

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Control Head for the integrated mounting on process valves

Compact Inductive Proximity Sensor

Manual Version: V1.00. Video Decoder Quick Guide

B63/ NS MS. EtherNet/IP LINK

Replacing Spare Parts

Mounting and Operating Instructions EB EN. Electric Actuators Type 5824 without fail-safe action Type 5825 with fail-safe action

SMVector Additional I/O Module Installation and Operation Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Vision OPLC V TR20/V350-J-TR20

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

Inductive sensor BI1.5-EG08-Y1-H1341

Transcription:

Type 8022 Flow Transmitter / Pulse divider Durchflusstransmitter / Impulsteiler Transmetteur de débit / Diviseur d impulsions We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. www.burkert.com Bürkert SAS, 2011-2016 Operating Instructions 1603/03_EU-ml 00809507 / Original FR Quickstart (from device Version 2) English 1. Quickstart...3 2. Intended Use...5 3. Basic Safety Instructions...6 4. General Information...8 5. Description...9 6. Technical Data... 10 7. Assembly, Installation... 13 8. Commissioning... 17 9. Adjustment... 17 10. Maintenance... 18 11. Packaging, Transport, Storage, Disposal... 19 1. Quickstart Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device. Important Safety Information! Read the quickstart carefully and thoroughly. Study in particular the chapters entitled Basic Safety Instructions and Intended Use. The quickstart must be read and understood. The quickstart explains, using examples, how to install and start-up the device. A detailed description of the device can be found in the operating instructions for type 8022. The operating instructions can be found on the enclosed CD and on the Internet at: www.burkert.com 2 English English 3

1.1. Symbols The following symbols are used in these instructions. Caution! Warns of a possible danger! Failure to observe this warning may result in a medium or minor injury. Warns of damage to property! Indicates important additional information, tips and recommendations. designates a procedure that must be carried out. 1.2. Definition of the term device In these instructions, the term device always refers to the flow transmitter type 8022 or the pulse divider type 8022. 2. Intended Use Use of the device that does not comply with the Operating Instructions could present risks to people, nearby installations and the environment. The flow transmitter type 8022, associated to a Bürkert flow sensor, converts the frequency signal generated by the flow sensor into an analogue 4-20 ma current signal. The pulse divider type 8022, associated to a Bürkert flow sensor, converts the frequency signal generated by the flow sensor into an adjustable frequency signal. The device is designed for use in industrial environments. Use the device in compliance with the characteristics and commissioning and use conditions specified in the contractual documents and in the Operating Instructions. Do not use the device for security applications. Do not use the device outdoors. Protect the device against electromagnetic interference and ultraviolet rays. Use the device only if in perfect working order. Properly transport, store, install and operate the device. Only use the device as intended. 4 English English 5 3. Basic Safety Instructions These safety instructions do not make allowance for any contingencies and events which may arise during the installation, operation and maintenance of the device. local safety regulations the operator is responsible for observing these regulations, also with reference to the installation personnel. Electrostatic sensitive components/modules! The device contains electronic components, which react sensitively to electrostatic discharge (ESD). Contact with electrostatically charged persons or objects is hazardous to these components. In the worst case scenario, they will be destroyed immediately or will fail after start-up. Observe the requirements in accordance with EN 61340-5-1 to minimize and evenavoid the possibility of damage caused by a sudden electrostatic discharge! Also, ensure that you do not touch electronic components when the power supply voltage is present! Various dangerous situations To avoid injury take care: not to use the device in explosive atmospheres. not to use the device in an environment incompatible with the materials it is made of. not to subject the device to mechanical loads (e.g. by placing objects on top of it or by using it as a step). not to make any modifications to the device. to prevent any unintentional power supply switch-on. to ensure that installation and maintenance work are carried out by qualified, authorised personnel in possession of the appropriate tools. to guarantee a defined or controlled restarting of the process, after a power supply interruption. to observe the general technical rules when installing and using the device. 6 English English 7

4. General Information 4.1. Contact Address To contact the manufacturer of the device, use following address: Bürkert SAS Rue du Giessen BP 21 F-67220 TRIEMBACH-AU-VAL The addresses of our international sales offices are available on the internet at: www.burkert.com 4.2. Warranty The warranty is only valid if the device is used as intended in accordance with the specified application conditions. 4.3. Information on the Internet The operating instructions and data sheets for type 8022 can be found on the Internet at: www.burkert.com 5. Description The device, when it is combined with a flow sensor, operates either as a flow transmitter thanks to a 4-20 ma current output, or as a pulse divider thanks to a transistor output. By default, the device operates as a flow transmitter. When operating as a flow transmitter, the device converts the frequency signal generated by the combined Bürkert flow sensor into an analogue 4-20 ma current signal (2-wire connection). When operating as a pulse divider, the device converts the frequency signal generated by the combined Bürkert flow sensor into an adjustable frequency signal (3-wire connection). The device may be fitted with a display and configuration unit. The display and configuration unit makes it possible to: change the operating mode of the device, configure the device. 8 English English 9 6. Technical Data 6.1. Operating conditions Ambient temperature -10...+60 C Protection class IP65 according to EN 60529, if the following conditions are respected: Cable gland wired or blanked-off, or female connector plugged-in and tightened Nut of the cable gland tightened with a torque of 1 N m ± 20 % (0,74 lbf ft ± 20 %). Housing closed and screw tightened with a torque of 0,3 N m ± 20 % (0,22 lbf ft ± 20 %), or display and configuration unit plugged on the device and screw tightened with a torque of 0,3 N m ± 20 % (0,22 lbf ft ± 20 %). Combined flow sensor Flow transmitter Bürkert flow sensor with a transistor output, in the Low Power version of the types 8020, 8030, 8070, SE30. Pulse divider Bürkert flow sensor with a transistor output, of the types 8020, 8030, 8070, SE30. 6.2. Mechanical Data Fastening device without display and configuration unit device with display and configuration unit Housing material Material of the seals seal for the sensor fixed connector seal for the cover 6.3. Electrical Data 1 M3 x 35 screw 1 M3 x 45 screw PA/PC NBR EPDM Electrical connection 4-pin terminal strip, 1.5 mm 2 Voltage supply, 12...+30 V DC Frequency input max. wire section, 6-7 mm cable diameter M12 male fixed connector filtered and regulated SELV circuit at a non dangerous energy level tolerance : ±10% residual ripple : < 5% 1-600 Hz, sensor supply voltage approximately V+ minus 1 V 10 English English 11

4-20 ma output Uncertainty of the output value Min. voltage drop at the device terminals Loop impedance Transistor output Uncertainty of the output value Maximum power consumption Operating as a flow transmitter (4-20 ma output in a 2-wire system) Operating as a pulse divider (NPN/PNP output in a 3-wire system) ±1,5% of the full scale < 10 V at 20 ma max. 100 W at 12 VDC, max. 700 W at 24 VDC, max. 1000 W at 30 VDC NPN or PNP, 50 ma max. current, frequency up to 600 Hz ±1% of the measured value 0,6 W 3,2 W, from which 0,2 W for the device, max. 1,5 W for the flow sensor, max. 1,5 W for the NPN/PNP output 7. Assembly, Installation 7.1. Assembly of the device For the fault-free operation of the device observe the following during installation: When screwing to the sensor, ensure the seal is seated correctly. Torque the screw to a value between 0.2 N m and 0.3 N m (between 0,15 and 0,22 lbf ft), in order not to damage the housing. With a damaged housing, correct operation of the device cannot be guaranteed. Fig. 1: Assembling the device and the sensor 12 English English 13 7.2. Electrical wiring The electrical connection of the device is made on a terminal strip via cable gland, or an M12 male fixed connector. 7.2.1. Wiring as a flow transmitter For an operation as a flow transmitter, wire the 4-20 ma current output with 2 wires, as described in Fig. 4. Terminal assignment 1 NPN 2 PNP 3 4 8022 4-20 ma Fig. 2: Terminal assignment, version with cable gland Pin assignment 1 2 NPN 3 4 PNP Fig. 4: Connection of the 4-20 ma current output of the flow transmitter 7.2.2. Wiring as a pulse divider For an operation as a pulse divider, wire the transistor output with 3 wires, as described in Fig. 5. The transistor output can be wired in NPN or in PNP mode with 3 wires. Fig. 3: Pin assignment, M12 male fixed connector 14 English English 15

Connection in NPN mode NPN 8022 e.g. PLC V+ IN 8. Commissioning Only energize the device when the cover is closed. Switch off the device before removing the display and configuration unit. 9. Adjustment Connection in PNP mode Fig. 5: PNP 8022 e.g. PLC V+ IN Connection of the transistor output of the pulse divider note The device is not tight when the display and configuration unit is removed. Screw the cover with order code 670549 on the device as soon as the display and configuration unit is removed. The display and configuration unit is only required to indicate the flow rate or to configure the device. It can be removed after the settings have been made. Switch off the device before removing the display and configuration unit. 16 English English 17 Adjust the device depending whether it is used as a flow transmitter or a pulse divider. Refer to the instruction manual on the delivered CD or on the internet at www.burkert.com. 10. Maintenance The device is maintenance-free when operated according to these operating instructions. 11. Packaging, Transport, Storage, Disposal Transport damage! Inadequately protected device may be damaged during transport. During transportation protect the device against moisture and dirt in shock-resistant packaging. Do not allow the temperature to exceed or drop below the permitted storage temperature. Incorrect storage may damage the device. Store the device in a dry and dust-free location! Storage temperature. -20 65 C Damage to the environment. Dispose of the device and packaging in an environmentally friendly manner. Observe applicable regulations on disposal and the environment. 18 English English 19