D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

Similar documents
INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

INSTRUCTION MANUAL. Switch/Proximity Detector Repeater Relay Output DIN-Rail Models D1030S, D1030D D1030S - D1030D

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

INSTRUCTION & SAFETY MANUAL

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E

INSTRUCTION MANUAL. Analog Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1052S, D1052D, D1052X, D1052Y D1052S - D1052D

INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D5030S, D5030D D5030S - D5030D.

INSTRUCTION & SAFETY MANUAL

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 12/2007

Zener Barriers Bulletin 937Z

INSTRUCTION & SAFETY MANUAL

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter Din-Rail Model D1064S D1064S

Operating Instructions

INSTRUCTION & SAFETY MANUAL

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

ETD-BL-1T-OFF-CC- 10S

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

PanelView Plus/VersaView CE Terminals and Display Modules

MACX MCR-EX-SD LP(-SP)

XPSMCMDI Input expansion module with screw term

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Redundancy Module QUINT-DIODE/40

XPSMCMDO Digital output pairs expansion modules with screw term

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

MACX MCR-EX-SL-NAM-R(-SP)

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Discrete Output Modules

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

MACX MCR-SL-(2)I-2)I-ILP(-SP)

APPLICATION GUIDE. Interface Modules IM Series.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

MACX MCR-EX-SL-NAM-2RO(-SP)

XPSMCMMX inputs 2 output pairs expansion module with screw term

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

M-series Intrinsically Safe I/O

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

5 Fieldbus Technology

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

DeltaV Bulk Power Supplies

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

PHOENIX CONTACT - 02/2008

DeltaV Bulk Power Supplies

FLEX Ex Spring Clamp Terminal Base

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Datasheet - SRB 402EM-24V

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Switched Mode Power Supply Operating manual PAP800

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PHOENIX CONTACT - 05/2007

MINI MCR-SL-PT100-UI(-SP)(-NC)

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Operating instructions. Switching amplifier DN0210 DN / / 2015

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Datasheet - SRB 301LC/B-24V

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

MINI MCR-SL-CVS NC

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Operating instructions. Speed monitor D / / 2014

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

MINI MCR-SL-PT100-UI-200

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description

PSR-PC20. SIL coupling relay. Data sheet. 1 Description

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Datasheet SRB301ST 24V (V.2)

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

DR7100 SERIES Supplementary instructions

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804 Digital Input Module with Time Stamp EP-12F4

Operating instructions. Standstill monitor A / / 2011

Installation & Operation Manual

MINI-PS AC/10-15DC/8

TRIO-DIODE/12-24DC/2X10/1X20

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Transcription:

D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096

SIL Applications For Safety Related System and SIL2, SIL Applications according IEC60 & IEC611 Standards refer to Functional Safety Manual document number ISM001 Characteristics General Description: The single channel DIN Rail Relay Output D109S is a relay module suitable for the switching of safety related circuits, up to SIL level according to IEC60, for high risk industries. It provides isolation between the input and output contact. D109S provides 1 DPST contact for normally energized loads and 1 SPST contact for normally deenergized loads. Diagnostic: Line breakage detection for NE and ND load conditions. Provides 1 SPST normally energized relay contact (closed) for fault indication. It deenergizes (open contact) in case of load or line fault. Function: 1 relay for safety related circuits, provides isolation between input/output/fault. D109S provides 1 DPST for NE loads and 1 SPST for ND loads. SIL Safety Function for NE load (deenergized in safe state) is available at Terminal Blocks 6; in this case, the safety function is met when the relay is deenergized (open contact). SIL Safety Function for ND load (energized in safe state) is available at Terminal Blocks ; in this case, the safety function is met when the relay is energized (closed contact). Signalling LEDs: Power supply indication (green), relay status (yellow), line fault (red). EMC: Fully compliant with CE marking applicable requirements. Technical Data Supply: 2 Vdc nom (20 to 0 Vdc) reverse polarity protected, ripple within voltage limits Vpp. Current consumption @ 2 V: 2 ma typical. Power dissipation: 0.6 W with 2 V supply voltage and fault relay energized, typical. Max. power consumption: at 0 V supply voltage and fault relay energized, 0.9 W. Isolation (Test Voltage): Output/Input 2. KV; Output/Supply 2. KV; Output/Fault Output 2. KV; Input/Supply 00 V; Input/Fault Output 00 V; Fault Output/Supply 00 V. Input: 2 Vdc nom (20. to 2.6 Vdc) reverse polarity protected. Current consumption @ 2 V: 0 ma with relay energized, typical. Power dissipation: 1.2 W with 2 V input voltage and relay energized, typical. Max. power consumption: at 2.6 V input voltage and relay energized, 1. W. Output: voltage free relay contact, normally open. Contact material: Ag Alloy (Cd free). Contact rating: A 20 Vac 0 VA, A 12 Vdc 120 W (resistive load). DC breaking capacity: V (V) 200 12 100 Resistive 0 0 0 20 10 I (A) 0.1 0.2 0. 0. 0. 1 2 Mechanical / Electrical life: 0 * 10 6 / 1 * 10 operation, typical. Operate / Release time: / ms typical. Bounce time NO / NC contact: ms. Frequency response: 10 Hz maximum. Fault detection: Deenergized fault signal: 0 µa continuous. Deenergized open output detection: load current 0 µa. Energized open output detection: load current 10 ma. Fault signalling: voltage free NE SPST relay contact (output deenergized in fault condition). Contact rating: A 20 Vac 0 VA, A 12 Vdc 120 W (resistive load). Response time: 200 ms typical. Compatibility: CE mark compliant, conforms to 9/9/EC Atex Directive and to 200/10/CE EMC Directive. Environmental conditions: Operating: temperature limits 20 to 60 C, relative humidity max 90 % non condensing, up to C. Storage: temperature limits to 0 C. Safety Description: II G Ex nac IIC T nonincendive electrical apparatus. 20 C Ta 60 C. Approvals: IMQ 09 ATEX 01 X conforms to EN60090, EN6009, FM & FMC No. 026, 029921C, conforms to Class 600, 611, 10 and C22.2 No.12, C22.2 No.21, E60090, E6009. TUV Certificate No. CIS1601, SIL according to IEC 60. Please refer to Functional Safety Manual for SIL applications. Proof Test Interval: 10 years for SIL application with NE load or years with ND load or 10 years with ND load (20 % of SIF). Mounting: T DIN Rail according to EN0022. Weight: about 0 g. Connection: by polarized plugin disconnect screw terminal blocks to accomodate terminations up to 2. mm 2. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T, Class I, Division 2, Groups A, B, C, D Temperature Code T and Class I, Zone 2, Group IIC, IIB, IIA T installation. Protection class: IP 20. Dimensions: Width 22. mm, Depth 99 mm, Height 11. mm. 2 D109 SIL Relay Output Module with Line and diagnostics G.M. International ISM0096

Ordering information Model: D109S Power Bus enclosure /B Front Panel and Features 1 2 6 SIL according to IEC 60 for Tproof 10 years (10 % of total SIF) with NE. SIL according to IEC 60 for Tproof / 10 years (10 / 20 % of total SIF) with ND. PFDavg (1 year).01 E06, SFF 99.19 % with NE. PFDavg (1 year) 1.1 E0, SFF 9.1 % with ND. Installation in Zone 2, Division 2. Line and open diagnostic in NE and ND conditions. PWR ON STATUS FAULT 1 DPST contact for NE load and 1 SPST contact for ND load. Three port isolation, Input/Output/Supply. EMC Compatibility to EN6100062, EN610006. D109 9 10 11 12 ATEX, FM & FMC Certifications. TUV Certification for SIL. 1 1 High Reliability, SMD components. Simplified installation using standard DIN Rail and plugin terminal blocks. Terminal block connections SAFE AREA SAFE AREA 9 Power Supply 2 Vdc 1 Loop Powered DC/AC maximum 12 Vdc, 20 Vrms 10 Power Supply 2 Vdc 2 Loop Powered DC/AC maximum 12 Vdc, 20 Vrms 11 Power Supply 2 Vdc Loop Powered DC/AC maximum 12 Vdc, 20 Vrms 12 Power Supply 2 Vdc Loop Powered DC/AC maximum 12 Vdc, 20 Vrms 1 Input Ch 1 Output Ch 1A for NE 1 Input Ch 1 6 Output Ch 1A for NE Fault Output Output Ch 1B for ND Fault Output Output Ch 1B for ND G.M. International ISM0096 D109 SIL Relay Output Module with Line and diagnostics

Function Diagram SAFE AREA, ZONE 2 GROUP IIC T, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D TCode T, CLASS I, ZONE 2, GROUP IIC T MODEL D109S 1 Supply 2 Vdc 9 10 11 2 Power DC/AC max. 12 Vdc, 20 Vrms 12 Diag. In Fault Out 1 1 6 Out 1B ND Out 1A NE Relay contact shown in deenergized position D109 SIL Relay Output Module with Line and diagnostics G.M. International ISM0096

Applications Application for D109S Normally Energized Condition (NE) PLC Output ON 2 Vdc 1 1 2 / AC Contacts 1 and 26: SIL Function is met when contacts are in open state. Contacts : Opening of contacts can be used for monitoring Contacts 1 and 26. No SIL Function. Contacts : Internally connected, cannot be changed. 6 2 Internally connected / AC Contacts : Voltage free contact for Line and Fault detection. Can be connected in series with other relay units for common monitoring. Application for D109S Normally DeEnergized Condition (ND) PLC Output OFF 0 Vdc 1 1 2 / AC Contacts 1 and 26: Closing of contacts can be used for monitoring Contacts. No SIL Function. Contacts : SIL Function is met when contacts are in closed state. Contacts : Internally connected, cannot be changed. 6 2 Internally connected / AC Contacts : Voltage free contact for Line and Fault detection. Can be connected in series with other relay units for common monitoring. G.M. International ISM0096 D109 SIL Relay Output Module with Line and diagnostics

Warning D109 is an isolated electrical apparatus installed into standard EN0022 T DIN Rail located in Safe Area/Non Hazardous Locations or Zone 2, Group IIC, Temperature Classification T, Class I, Division 2, Groups A, B, C, D, Temperature Code T and Class I, Zone 2, Group IIC, IIB, IIA Temperature Code T Hazardous Area/Hazardous Locations (according to EN/IEC6009, FM Class No. 611, CSAC22.2 No. 21M19, CSAE6009) within the specified operating temperature limits Tamb 20 to 60 C, and connected to equipment with a maximum limit for AC power supply of 20 Vrms. Hazardous (Classified) Locations Class I, Division 2, Groups A, B, C, D Class II, Division 2, Groups E, F, G Class III, Division 2 Class I, Zone 2, Group IIC, IIB, IIA Nonincendive Nonincendive Nonincendive FM Approved under nonincendive field wiring (permitted only for US installations), or third party approval Unclassified Locations or Hazardous (Classified) Locations Class I, Division 2, Groups A, B, C, D, TCode T Class I, Zone 2, Group IIC, IIB, IIA, TCode T 1 2 6 D109 Relay Output FM Approved under nonincendive field wiring Nonincendive field wiring is not recognized by the Canadian Electrical Code, installation is permitted in the US only. For installation of the unit in a Class I, Division 2 or Class I, Zone 2 location, the wiring between the control equipment and the D109 electrical apparatus shall be accomplished via conduit connections or another acceptable Division 2, Zone 2 wiring method according to the NEC and the CEC. Not to be connected to control equipment that uses or generates more than 20 Vrms or Vdc with respect to earth ground. D109 must be installed, operated and maintained only by qualified personnel, in accordance to the relevant national/international installation standards (e.g. IEC/EN60091 Electrical apparatus for explosive gas atmospheres Part 1: Electrical installations in hazardous areas (other than mines), BS Pt, VDE, ANSI/ISA RP12.06.01 Installation of Intrinsically Safe System for Hazardous (Classified) Locations, National Electrical Code NEC ANSI/NFPA 0 Section 0 and 0, Canadian Electrical Code CEC) following the established installation rules. Deenergize power source (turn off power supply voltage) before plug or unplug the terminal blocks when installed in Hazardous Area/ Hazardous Locations or unless area is known to be nonhazardous. Warning: substitution of components may impair Intrinsic Safety and suitability for Division 2, Zone 2. Warning: deenergize main power source (turn off power supply voltage) and disconnect plugin terminal blocks before opening the enclosure to avoid electrical shock when connected to live hazardous potential. Explosion Hazard: to prevent ignition of flammable or combustible atmospheres, disconnect power before servicing or unless area is known to be nonhazardous. Failure to properly installation or use of the equipment may risk to damage the unit or severe personal injury. The unit cannot be repaired by the end user and must be returned to the manufacturer or his authorized representative. Any unauthorized modification must be avoided. Operation D109 relay module is suitable for the switching of safety related circuits, providing isolation between the input and output contacts. D109 provides 1 DPST contact for normally energized (NE) loads and 1 SPST contact for normally deenergized (ND) loads. In addition, there is a diagnostic circuit for line breakage and load operating anomaly detection in both NE and ND load conditions. The fault indication is provided by a SPST normally energized relay (normally close contact), which is deenergized (open contact) in case of line or load fault. The fault output, diagnostic circuit, input and output contacts are isolated each other. In fact, the diagnostic circuit is supplied from independent external power supply. A POWER ON green led lights when supply power is present. A RELAY STATUS yellow led lights when input is powered, showing that relay is energized and relay output contacts are closed. A LINE FAULT red led lights when line breakage and load operating anomaly is detected. Installation Unclassified Locations Must not use or generate more than 20 Vrms or Vdc Control Control D109 is a relay output modules housed in a plastic enclosure suitable for installation on T DIN Rail according to EN0022. D109 unit can be mounted with any orientation over the entire ambient temperature range, see section Installation in Cabinet and "Installation of Electronic s in Cabinet" Instruction Manual D1000 series for detailed instructions. Electrical connection of conductors up to 2. mm² are accommodated by polarized plugin removable screw terminal blocks which can be plugged in/out into a powered unit without suffering or causing any damage (for Zone 2 or Division 2 installations check the area to be nonhazardous before servicing). The wiring cables have to be proportionate in base to the current and the length of the cable. On the section Function Diagram and enclosure side a block diagram identifies all connections. Identify the function and location of each connection terminal using the wiring diagram on the corresponding section, as an example: Connect 2 Vdc power supply positive at terminals 9 (or 11 ) and negative at terminals 10 (or 12 ), to drive the diagnostic circuits. Connect positive input at terminal 1 and negative input at 1. Connect fault indication relay output contact at terminal and. In case of NE loads, connect the NE loads at positive terminal and negative terminal 6. In case of ND loads, connect the ND loads at positive terminal and negative terminal. If load requires DC power supply, connect supply line positive at terminals 1 (or ) and negative at terminals 2 (or ). If load requires AC power supply, connect AC lines at terminals 1 (or ) and 2 (or ). Installation and wiring must be in accordance to the relevant national or international installation standards (e.g. IEC/EN60091 Electrical apparatus for explosive gas atmospheres Part 1: Electrical installations in hazardous areas (other than mines), BS Pt, VDE, ANSI/ISA RP12.06.01 Installation of Intrinsically Safe System for Hazardous (Classified) Locations, National Electrical Code NEC ANSI/NFPA 0 Section 0 and 0, and the Canadian Electrical Code CEC), make sure that conductors are well isolated from each other and do not produce any unintentional connection. Connect output relay contacts checking the load rating to be within the contact maximum rating ( A, 20 Vac or 12 Vdc, 0 VA 120 W resistive load). If necessary, to prevent relay contacts from damaging, an external protection (fuse or similar) should be connected. A suitable protection must be chosen according to the relay breaking capacity diagram on data sheet. Connect fault indication relay contacts checking the load rating to be within the contact maximum rating ( A, 20 Vac or 12 Vdc, 0 VA 120 W resistive load). The enclosure provides, according to EN6029, an IP20 minimum degree of mechanical protection (or similar to NEMA Standard 20 type 1) for indoor installation, outdoor installation requires an additional enclosure with higher degree of protection (i.e. IP to IP6 or NEMA type 121) consistent with the effective operating environment of the specific installation. Units must be protected against dirt, dust, extreme mechanical (e.g. vibration, impact and shock) and thermal stress, and casual contacts. If enclosure needs to be cleaned use only a cloth lightly moistened by a mixture of detergent in water. Electrostatic Hazard: to avoid electrostatic hazard, the enclosure of D109 must be cleaned only with a damp or antistatic cloth. Any penetration of cleaning liquid must be avoided to prevent damage to the unit. Any unauthorized card modification must be avoided. Relay output contact must be connected to loads non exceeding category I, pollution degree I overvoltage limits. Warning: deenergize main power source (turn off power supply voltage) and disconnect plugin terminal blocks before opening the enclosure to avoid electrical shock when connected to live hazardous potential. 6 D109 SIL Relay Output Module with Line and diagnostics G.M. International ISM0096 9 10 11 12 1 1 Power Supply

Startup Before powering the inputs of unit check that all wires are properly connected, also verifying their polarity. Check conductors for exposed wires that could touch each other causing dangerous unwanted shorts. Turn on power supply for diagnostic circuits, the power on green led must be lit. Then enabling the input of channel, the RELAY STATUS yellow led must be lit and load circuit must be energized because relay output contact is closed. Indeed, disabling the input of channel, the RELAY STATUS yellow led must be turned off and load circuit must be deenergized because relay output contact is open. The LINE FAULT red led could only be lit when line breakage or load operating anomaly is detected by internal diagnostic circuits, imposing to deenergize the SPST relay (open its contact) for fault indication. Installation in Cabinet Power Dissipation of D109 Isolators Section Technical Data of D109 isolator specifies the current consumption (maximum current from the nominal power supply, typical 2 Vdc, in normal operation); this data serves to dimension the current rating of the power supply unit. Section Technical Data indicates also the maximum power consumption (maximum power required from the power supply in the worst (abnormal) operating conditions like for example supply voltage at 0 Vdc, short circuit on the outputs and on the inputs terminals. The power dissipated Pd inside the enclosure for analog signal isolators is: Pd Current Consumption (A) * Supply Voltage (V) Power Dissipated into the input/output loads Analog signal isolators have higher dissipation than digital signal isolators. In analog signal isolators each transmitter requires and dissipates V * 0.02 A 0. W. Usually the loads outside the isolator dissipate 1/ of the total power used. Isolators are not running at the maximum current all at the same time, the average power consumption of a multitude of isolators can be considered to be only 0 % of the value obtained from the section Technical Data. Considering the 1/ load power and the 0 % above discussed, the power effectively dissipated internally by the isolators can therefore become ½ of the actual power delivered by the power supply. Digital barriers dissipate all the supply power inside the enclosure consequently the total power dissipation into a cabinet, with mixed analog and digital barriers, is determined by the number of channels more than by the number of isolator enclosures. The following tables give advises for the DIN rail orientation (vertical or horizontal) of the barriers mounting, D109S (single channel) isolators, installed on DIN rail, bus or custom board assembly. A) Cabinet with Natural Ventilation Maximum recommended ambient temperature in C depending on barrier type and installation method: Single unit Type of Isolator Installation Installation of Multiple units with DINrail Bus Any orientation Vertical Horizontal Vertical Installation on Custom Boards Horizontal D109S 60 C 0 C C C 0 C B) Cabinet with Forced Ventilation Maximum recommended ambient temperature in C depending on barrier type and installation method: Type of Isolator Single unit Installation Installation of Multiple units with DINrail Bus Any orientation Vertical Horizontal Vertical Installation on Custom Boards Horizontal D109S 60 C 0 C C C 0 C G.M. International ISM0096 D109 SIL Relay Output Module with Line and diagnostics