Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21

Similar documents
Integrating the Yieldpoint d-exto MPBX

Integrating the MDT SMART Link-485 Sensor Application Note #32

Sensor Mux Wiring Diagrams MultiLogger Application Note #17 Revision March 2008

Integrating HART Sensors with the Campbell CR1000 Datalogger

Using the Lantronix SGX 5150 Serial Device Server

AquaTroll 600 Configuration and MultiLogger Integration

Integrating the RXTX Telependulum with the CR800/CR1000 Sensor Application Note #17

Using the VWDSP Interface Application Note #11

Integrating SISGEO Digitized MEMs IPI s with the CR800 or CR1000 Sensor Application Note #21

Integrating the White Mini-Seis III Seismic Recorder with MultiLogger Suite

Integrating the Measurand Shape Accelerometer Arrays (SAA) Sensor Application Note #19

MultiMux Multiplexer

MiniMux Multiplexer USER S GUIDE

All About the MultiLogger Setup File Application Note #7

MultiLogger Software

CANARY. Acquisition Solutions. What Do We Do? Software Systems. Network Management. Sensors Input. Dataloggers Measure. Communications Transfer

Geokon Model D Pendulum Operation Notes Sensor Application Note #16

Using the RAVEN II CDPD Modem Application Note #12

900 MHz Spread Spectrum Radio TOP FRONT. Click 400

Vibrating Wire Instrument Assembly Guide

Using the Lantronix WiBox with the CR800 or CR1000

MST Database Integration Database Application Note #10

Using the MultiLogger Language Manager Software Application Note #18 Revision

VW2110 Vibrating Wire Readout Calibrator Manual

CAMPBELL BASED MULTI-CHANNEL DATA LOGGER LITE USER MANUAL

INSTRUCTION MANUAL. PakBus Networking Guide for the CR10X, CR510, CR23X, and CR200 Series and LoggerNet 2.1C. Revision: 3/05

Canlan INSTALLATION MANUAL

Integrating the Kinemetrics Obsidian Seismic Recorder with MultiLogger Suite

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Temperature Measurements using the KPCI-3108 with the EXP-1800

Model Datalogger (Micro-6000)

LynX-10 PLC Bi-directional X-10 Interface Quick Start Manual version 1.20

T3 Interface Converters

Campbell Based Multi-Channel Data Logger Lite. User Manual. Man158a /05/2015 Final Ben Scott James Kwist Philip Day. Manual No.

WIRELESS ASSET MONITORING

Cinterion BGS2T (RS232) Terminal Starter Kit. Getting Started Guide

M-Logger Copyright 2011 DGSI. All Rights Reserved.

Revision: 10/26/2018 Copyright Campbell Scientific

1510A. MTI Instruments, Inc. 325 Washington Avenue Extension, Albany, New York USA Phone: (518) FAX: (518)

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

AVG-HD402PR. Features

RGM180 Display Series

Cellular modem and Transceiver

Access Your 34972A Wirelessly with a TRENDnet Travel Router

Advantage III. Gold Series by Ebtron. Installation Guide GTD116, GTD108. Data Logger Option Card for Plug & Play Transmitters

Owner's Manual SPK-24G. 2.4GHz Wireless Outdoor Speaker System. (Read carefully the instructions before using this system)

G-LOG Mobile Application

DD-600. A member of the Data Dolphin Family of Data Logging Systems. Data Dolphin Installation and Usage Manual

last update December 1, 2010 reference smtirin06n page 1/21 SMARTEC INFRARED INTERFACE BOARD SMTIRIN06

Dataloggers Also known as Data Loggers, Data Recorders, & RTUs

S-One Technology Co., Ltd.

Online. COM220 Phone Modem. Last Training Course for 2008 DOWNLOAD THE LATEST O/S & SOFTWARE UPDATES. I s s u e 2 2 A u g / O c t

Eaton Logic Controller Modbus Distributed I/O Adapter Module INSTRUCTION SHEET

2D Image Handheld Scanner

Integration of ShapeAccelArray and Campbell Scientific CR800/CR1000 Data Loggers

G801 Digital and Interconnection Logging Module for managing of monitoring systems. MAIN FIELDS OF APPLICATION

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

USR Drive Flash Memory Serial Flash Memory CPU Drive MicroSD (CRD: Drive) Storage Formatting MicroSD Cards...

DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS

INSTRUCTION MANUAL. RELAY MULTIPLEXER Model : RT-MUX 16/32. Roctest Limited All rights reserved

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

Remote Display User Manual

Maestro Podium. User manual

WVL2 Wireless Vehicle Link 2 Installation and Setup Manual

Wireless Temperature Module

HIGH SPEED SIGNAL CHAIN SELECTION GUIDE

High-resolution CCD Camera. Model CS3920 PRODUCT SPECIFICATION

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

COMPONENTS SOFTWARE. Programming, Display, Development. questions & quotes: campbellsci.ca/software

Table of Contents. Chapter 1: Getting Started. Chapter 2: Specifications

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Stat Crew to Nevco Stats Panel Interface

NTSC/PAL. 3CCD Color Video Camera BRC-300 BRC-300P

MIU-1000 v. Revised: 4/20/2009. Copyright 2008, Traf-SYS, Inc.

OPERATION MANUAL. MV-410HS Web Browser. Version Rev.2

5Troubleshooting CHAPTER FIVE IN THIS CHAPTER. LED Status Software Commands for Troubleshooting RS-232/485 Troubleshooting System Problems

Using Operator Interfaces to Optimize Performance of Industrial Wireless Networks

DATA LOGGERS GL800 & 1000

Troubleshooting CHAPTER

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

NTSC/PAL. 3CCD Color Video Camera BRC-300 BRC-300P

GeoAudio+ Portable GPS to Audio Encoder / Decoder with Internal High Precision GPS Receiver and Antenna. Version 1.00

Lite-On Power ChungHo Controlled. Do Not Copy.

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

CF3000 Dealer Diagnostic Tool Instruction Manual

EWAVE Inc Gracefield Ln. Dallas, Texas (972)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Series CCR-59S/CR-59S Multi-Throw DC-26.5 GHz Latching Coaxial Switch

Product Family: Networking Hardware Number: AN-NH-012

Bluetooth to Serial Converter TOP FRONT. Click 421

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

Vehicle DC-DC 150W User Guide DCA 7

Voltage Measurements Single-Ended Measurements Differential Measurements Current-Loop Measurements Voltage Ranges for Current

Using ECOpartner results in cost saving, energy savings, energy-use awareness, enhanced patterns of energy use, and conservation.

Field Service Procedure Replacement 400MHz Modem Kit

Transcription:

5 ould Road, PO Box 2155 New London, NH 03257 Voice: (603) 526-9088 info@canarysystems.com www.canarysystems.com Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Overview The AVW2xx series of interfaces from Campbell Scientific provide high-quality vibrating wire measurements by using a spectrum analysis technique to output the gage readings. This provides for highquality measurement of the vibrating wire gages particularly in electrically noisy environments as well as higher resolution in electrically quiet environments. There are several versions of the AVW2xx available: AVW200 For wired configurations, or for wireless using non-campbell wireless solutions. AVW206 Includes integrated 900MHz spread spectrum radio for wireless applications. AVW211 Includes integrated 922MHz spread spectrum radio for wireless applications. AVW216 Includes integrated 2.4Hz spread spectrum radio for wireless applications. This MultiLogger Application Note will detail the configuration issues involved for using the wired (connected directly to the Campbell CR800 or CR1000) as well as wireless versions (units that include an integrated spread spectrum radio). Note: The age Types Makes Models supported in MultiLogger all use a range of 400-4000Hz for the vibrating wire frequency range. This should be adequate for most installations. Contact Canary Systems for direction to narrow or widen the frequency range. The following wired configurations will be detailed: AVW200 with direct connect gages. AVW200 with multiplexers controlled by the MCU. AVW200 with multiplexers controlled by the AVW200. The following wireless configurations will be detailed: AVW2xx with direct connect gages. AVW2xx with multiplexers controlled by the AVW2xx. See the AVW200 Operators Manual for more information on other deployments. Note: MultiLogger currently only supports the AVWxx when using the CR800 and CR1000 MCU s. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 1 of 13

Configuring the AVW2xx with CSI Device Configuration Software Note: For proper function the CR800 FW must be v8 or higher, for the CR1000 v17 or higher. The first step is getting familiar with the Device Configuration software and the settings of the AVW2xx. It is very straight-forward to configure the unit for the wired or wireless deployments. The Device Configuration software is included with LoggerNet or may be downloaded from the Campbell Scientific website at http://www.campbellsci.com/downloads Follow these steps: 1. Connect a power supply to the AVW2xx, either using an AC Adaptor or the CR800 /CR1000 & connections on the wiring panel. 2. Connect a standard RS-232 cable between the AVW2xx RS-232 port and the computers COM port. 3. Launch the Device Configuration software. The AVW2xx is the first device in the Device Type list so it will display by default when launching the software. 4. Press the Connect button to connect to the AVW2xx. If you receive the error shown at right then check connections and try again. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 2 of 13

Once connected you will see a main tab control, then a secondary tab control on the main Deployment tab. The secondary tabs, Communications and Measurements are used for configuring the AVW2xx. See the AVW200 Operators Manual for information on the other tabs of the main tab control. Note: For the AVW200 (non-wireless) the radio settings will be disabled. The following are the main settings for configuring wired or wireless deployments: Wired Deployments PakBus Address SDI-12 Address (found on Measurements tab set to 0) Multiplexer Type (if using multiplexers found on Measurements tab) Wireless Deployments PakBus Address Multiplexer Type (if using multiplexers found on Measurements tab) Hop Sequence Radio Address Power Mode Note: For wireless deployments make sure the Hop Sequence, Net Address and Power Mode match the RF4xx being used for communication with the AVW2xx. If settings are changed press the Apply button to update the AVW2xx, otherwise press Disconnect. A summary report will display, this can be saved as an XML file for updating other units or printed for record keeping. See the following section on configuring the RF4xx radio for wireless deployments. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 3 of 13

Configuring the RF4xx with CSI Device Configuration Software For wireless applications the RF4xx spread spectrum radio must be configured for use with the AVW2xx. Use Campbells Device Configuration software to configure the radio. The Device Configuration software is included with LoggerNet or may be downloaded from the Campbell Scientific website at http://www.campbellsci.com/downloads Follow these steps: 1. Connect a power supply to the RF4xx, either using an AC Adaptor or the coax power cable which allows you to wire to the CR800 /CR1000 & connections on the wiring panel. Alternately you may connect the CS I/O connectors on the RF4xx and using the supplied SC12 cable. 2. Connect a standard RS-232 cable between the RF4xx RS-232 port and the computers COM port. 3. Launch the Device Configuration software. Scroll down the Device Type list to find the The AVW2xx is the first device in the Device Type list so it will display by default when launching the software. 4. Press the Connect button in Device Configuration then press the green Configuration Mode button on the RF4xx, located between the RS-232 connection and antenna connection. If you receive the error shown at right then check connections and try again. The red power LED should be illuminated on the RF4xx. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 4 of 13

5. Once connected you will be shown the Deployment tab for the RF4xx. The following are the main settings for configuring the RF4xx: Protocol (set to PakBus Aware) Hop Sequence Radio Address Power Mode Note: Make sure the Hop Sequence, Net Address and Power Mode match the AVW2xx being used with RF4xx. See the RF4xx Operators Manual for information on other settings but for most deployments no other settings need to be modified from the factory defaults. Note: Contact Canary Systems for direction with more complicated configurations including use of static PakBus route maps. If settings are changed press the Apply button to update the RF4xx, otherwise press Disconnect. A summary report will display, this can be saved as an XML file for updating other units or printed for record keeping. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 5 of 13

Wired Configuration AVW200 with Direct Connect ages The following configuration depicts an AVW200 connected directly to the CR800 or CR1000, with gages connected directly (no multiplexers) to the AVW200. Up to 2 gages may be directly connected to the AVW200. The connection scheme utilizes SDI-12, this allows a single control port connection to the MCU. Other configurations are possible including use of the RS-232 port. See the AVW200 Operators Manual for more information on these configurations. AVW200 C3 (CR800) C7 (CR1000) C1 (SDI12) C2 (CLK) C3 (RES) ND 1V+ 1V- 1T+ 1T- ND 2V+ 2V- 2T+ 2T- VW#2 Note: Wire colors may vary by manufacturer. To configure MultiLogger use the following Direct Connect age Type Make Model selections: age Type Make Model Description Output Units Vibrating Wire eneric AVW200 CH1 Digits Channel 1 with excitation Digits AVW200 CH1 Hz Channel 1 with excitation Hz AVW200 CH1 5V Digits Channel 1 with 5V excitation Digits AVW200 CH1 5V Hz Channel 1 with 5V excitation Hz AVW200 CH2 Digits Channel 2 with excitation Digits AVW200 CH2 Hz Channel 2 with excitation Hz AVW200 CH2 5V Digits Channel 2 with 5V excitation Digits AVW200 CH2 5V Hz Channel 2 with 5V excitation Hz Notes: All of these Models use a frequency range of 400-4000Hz which should be adequate for most installations. Contact Canary Systems for direction to narrow or widen the frequency range. All of these Models use SDI-12 address 0. Contact Canary Systems for direction when using a different SDI-12 address. To read the Upper Channel (Temperature Device): Device Description Output Units AVW200_YSI44005- C YSI type 44005 on Channel 1 or 2 C AVW200_YSI44005- F YSI type 44005 on Channel 1 or 2 F Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 6 of 13

Wired Configuration AVW200 with Multiplexers Controlled by MCU (2-6 multiplexers) The following configuration depicts an AVW200 connected directly to the CR800 or CR1000, with gages connected to multiplexers controlled by the CR800 or CR1000. Note: A maximum of 2 multiplexers can be connected to the CR800 using this configuration. See the following section for connecting up to 4 multiplexers to the CR800 and up to 10 multiplexers to the CR1000. C3 (CR800) C7 (CR1000) C1 C2 C4 (CR800) AVW200 C1 (SDI12) C2 (CLK) C3 (RES) ND 1V+ 1V- 1T+ 1T- ND 2V+ 2V- 2T+ 2T- MUX#1 MUX#2 Note: Wire colors may vary by manufacturer. Use the following configuration for the multiplexers: Mux Mux Model age Type Channels Wires Enable Clock 1 As Req d Vibrating Wire 16/32 4/2 C1 C4 (CR800) 2 As Req d Vibrating Wire 16/32 4/2 C2 C4 (CR800) 3 As Req d Vibrating Wire 16/32 4/2 C3 (CR1000) 4 As Req d Vibrating Wire 16/32 4/2 C4 (CR1000) 5 As Req d Vibrating Wire 16/32 4/2 C5 (CR1000) 6 As Req d Vibrating Wire 16/32 4/2 C6 (CR1000) Use the same gage types for Channel Configuration as shown in Direct Connect Section. Note: Only use the Channel 1 age Types. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 7 of 13

Wired Configuration AVW200 with Multiplexers Controlled by MCU (4-10 multiplexers) The following configuration depicts an AVW200 connected directly to the CR800 or CR1000, with gages connected to multiplexers controlled by the CR800 or CR1000. Up to 4 multiplexers can be controlled when using the CR800, up to 10 (up to 12 can be controlled but MultiLogger is limited to 10) when using the CR1000. C3 (CR800) C7 (CR1000) C1 C2 C4 (CR800) AVW200 C1 (SDI12) C2 (CLK) C3 (RES) Note: See tables on following page for Control Port connections for 6, 8 and 10 multiplexers. ND 1V+ 1V- 1T+ 1T- ND 2V+ 2V- 2T+ 2T- MUX#1 MUX#2 MUX#3 MUX#4 Note: Wire colors may vary by manufacturer. See the tables on the following page for the 4, 6, 8 and 10 multiplexer connection/configuration tables. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 8 of 13

Use the following configuration for 4 multiplexer configuration: Mux Mux Model age Type Channels Wires Enable Clock AVW2xx CH 1 As Req d Vibrating Wire 16/32 4/2 C1 C4 (CR800) 1 2 As Req d Vibrating Wire 16/32 4/2 C2 C4 (CR800) 1 3 As Req d Vibrating Wire 16/32 4/2 C1 C4 (CR800) 2 4 As Req d Vibrating Wire 16/32 4/2 C2 C4 (CR800) 2 Use the following configuration for 6 multiplexer configuration (CR1000 only): Mux Mux Model age Type Channels Wires Enable Clock AVW2xx CH 1 As Req d Vibrating Wire 16/32 4/2 C1 C8 1 2 As Req d Vibrating Wire 16/32 4/2 C2 C8 1 3 As Req d Vibrating Wire 16/32 4/2 C3 C8 1 4 As Req d Vibrating Wire 16/32 4/2 C1 C8 2 5 As Req d Vibrating Wire 16/32 4/2 C2 C8 2 6 As Req d Vibrating Wire 16/32 4/2 C3 C8 2 Use the following configuration for 8 multiplexer configuration (CR1000 only): Mux Mux Model age Type Channels Wires Enable Clock AVW2xx CH 1 As Req d Vibrating Wire 16/32 4/2 C1 C8 1 2 As Req d Vibrating Wire 16/32 4/2 C2 C8 1 3 As Req d Vibrating Wire 16/32 4/2 C3 C8 1 4 As Req d Vibrating Wire 16/32 4/2 C4 C8 1 5 As Req d Vibrating Wire 16/32 4/2 C1 C8 2 6 As Req d Vibrating Wire 16/32 4/2 C2 C8 2 7 As Req d Vibrating Wire 16/32 4/2 C3 C8 2 8 As Req d Vibrating Wire 16/32 4/2 C4 C8 2 Use the following configuration for 10 multiplexer configuration (CR1000 only): Mux Mux Model age Type Channels Wires Enable Clock AVW2xx CH 1 As Req d Vibrating Wire 16/32 4/2 C1 C8 1 2 As Req d Vibrating Wire 16/32 4/2 C2 C8 1 3 As Req d Vibrating Wire 16/32 4/2 C3 C8 1 4 As Req d Vibrating Wire 16/32 4/2 C4 C8 1 5 As Req d Vibrating Wire 16/32 4/2 C5 C8 1 6 As Req d Vibrating Wire 16/32 4/2 C1 C8 2 7 As Req d Vibrating Wire 16/32 4/2 C2 C8 2 8 As Req d Vibrating Wire 16/32 4/2 C3 C8 2 9 As Req d Vibrating Wire 16/32 4/2 C4 C8 2 10 As Req d Vibrating Wire 16/32 4/2 C5 C8 2 Note: Use the same gage types for Channel Configuration as shown in Direct Connect Section. Be sure to use appropriate Channel type to match multiplexer to AVW2xx wiring. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 9 of 13

Wired Configuration AVW200 with Multiplexers (up to 2) The following configuration depicts an AVW200 connected directly to the CR800 or CR1000, with gages connected to multiplexers controlled by the AVW200. Note: You will need to configure the AVW2xx for which type of multiplexer is connected. See the introductory section for information on using Campbells Device Configuration software to do this. COM1 COM2 (COM3) (COM4) COM3&4 CR1000 Only C1 (TD) 3 C2 (RD) 2 5 For COM connection use CSI 178555 Cable (example COM1 wiring below) AVW200 DB-9 AVW200 RS-232 Each multiplexer would be configured separately in MultiLogger. When configuring the multiplexers use the Multiplexer Model AVW2xx. Configure the Channels to match the multiplexer configuration. Up to 16 vibrating wire gages with temperature can be read, or 32 channels without temperature. Use the following age Type Make Model selections for the Multiplexer 1 Channel Configuration: age Type Make Model Description Output Units Vibrating Wire AVW2xx COM1 PB200 CH1 Digits PakBus ID 200 CH1 connected to Com1 Digits COM2 PB200 CH1 Digits PakBus ID 200 CH1 connected to Com2 Digits COM3 PB200 CH1 Digits PakBus ID 200 CH1 connected to Com3 Digits COM4 PB200 CH1 Digits PakBus ID 200 CH1 connected to Com4 Digits Use the following age Type Make Model selections for the Multiplexer 2 Channel Configuration: age Type Make Model Description Output Units Vibrating Wire AVW2xx COM1 PB200 CH2 Digits PakBus ID 200 CH2 connected to Com1 Digits COM2 PB200 CH2 Digits PakBus ID 200 CH2 connected to Com2 Digits COM3 PB200 CH2 Digits PakBus ID 200 CH2 connected to Com3 Digits COM4 PB200 CH2 Digits PakBus ID 200 CH2 connected to Com4 Digits Note: These gage types all use 12 volt excitation which should be appropriate for most gages. Contact Canary Systems if you experience unexplained measurement instability. To read the Upper Channel (Temperature Device): ND 1V+ 1V- 1T+ 1T- ND 2V+ 2V- 2T+ 2T- Device Description Output Units AVW200_YSI44005- C YSI type 44005 on Channel 1 or 2 C AVW200_YSI44005- F YSI type 44005 on Channel 1 or 2 F C3 (RES) C2 (CLK) MUX#1 MUX#2 Note: Wire colors may vary by manufacturer. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 10 of 13

Wireless Configurations AVW200 with Instruments Directly Connected The following configuration depicts an AVW200 connected wirelessly to the CR800 or CR1000 with gages connected directly (no multiplexers) to the AVW200. Up to 2 gages may be directly connected to the AVW200. The radio is a matching RF4xx, connected to the MCU on the CS I/O connection using the SC12 cable. See the introductory sections on configuring the AVW2xx and RF4xx for wireless operation. Contact Canary Systems for assistance with using other communications interfaces for the RF4xx the RS-232 port and COM1-COM4 (COM1-COM2 on CR800) can be supported. RF4xx AVW2xx CS I/O CS I/O SC12 Cable ND 1V+ 1V- 1T+ 1T- Power Supply Power Supply ND 2V+ 2V- 2T+ 2T- VW#2 Note: Wire colors may vary by manufacturer. To configure MultiLogger use the following Direct Connect age Type Make Model selections: age Type Make Model Description Output Units Vibrating Wire AVW2xx SDC7 PB2nn CH1 Digits PakBus 2nn CH1 connected to SDC7 (CS I/O) Digits SDC7 PB2nn CH2 Digits PakBus 2nn CH2 connected to SDC7 (CS I/O) Digits Where; PB2nn: Select the actual address for the device in use. Note that PakBus addresses 200-215 are currently supported. Contact Canary Systems if your application requires deployment of more than 16 AVW2xx s. Note: These gage types all use 12 volt excitation which should be appropriate for most gages. Contact Canary Systems if you experience unexplained measurement instability. To read the Upper Channel (Temperature Device): Device Description Output Units AVW200_YSI44005- C YSI type 44005 on Channel 1 or 2 C AVW200_YSI44005- F YSI type 44005 on Channel 1 or 2 F Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 11 of 13

Wireless Configurations AVW200 with Multiplexers (up to 2) The following configuration depicts an AVW200 connected wirelessly to the CR800 or CR1000 with gages connected to multiplexers connected to the AVW200. Up to 2 multiplexers may be directly connected to the AVW200. The multiplexers may be configured for 16 channel mode to include reading the temperature, or 32 channels without temperature. Note: You will need to configure the AVW2xx for which type of multiplexer is connected. See the introductory section for information on using Campbells Device Configuration software to do this. CS I/O RF4xx CS I/O SC12 Cable Power Supply Power Supply AVW2xx ND 1V+ 1V- 1T+ 1T- C3 (RES) C2 (CLK) ND 2V+ 2V- 2T+ 2T- MUX#1 MUX#2 Note: Wire colors may vary by manufacturer. Each multiplexer would be configured separately in MultiLogger. When configuring the multiplexers use the Multiplexer Model AVW2xx. Configure the Channels to match the multiplexer configuration. Up to 16 vibrating wire gages with temperature can be read, or 32 channels without temperature. Use the following age Type Make Model selections for the Multiplexer 1 Channel Configuration: age Type Make Model Description Output Units Vibrating Wire AVW2xx SDC7 PB200 CH1 Digits PakBus 200 CH1 with excitation Digits PB200 CH1 Hz PakBus 200 CH1 with excitation Hz PB200 CH1 5V Digits PakBus 200 CH1 with 5V excitation Digits PB200 CH1 5V Hz PakBus 200 CH1 with 5V excitation Hz Use the following age Type Make Model selections for the Multiplexer 2 Channel Configuration: age Type Make Model Description Output Units Vibrating Wire AVW2xx SDC7 PB200 CH2 Digits PakBus 200 CH2 with excitation Digits PB200 CH2 Hz PakBus 200 CH2 with excitation Hz PB200 CH2 5V Digits PakBus 200 CH2 with 5V excitation Digits PB200 CH2 5V Hz PakBus 200 CH2 with 5V excitation Hz Note: PakBus addresses 200-215 are currently supported however MultiLogger is limited to 10 multiplexers. Select the appropriate PakBus address to match the device in use. See the previous section for configuring the temperature measurement. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 12 of 13

Troubleshooting The Campbell AVW200 Operators Manual has additional information on trouble-shooting, particularly for the wireless deployments. It also contains information on using the Device Configuration software to view the vibrating wire signal responses to trouble-shoot poorly performing gages or noisy environments. This section will provide guidelines to aid in trouble-shooting the commonly encountered issues. MultiLogger provides several metrics to aid in troubleshooting, as follows: When instruments are disconnected or otherwise fail to read the Text Monitor will show OVERRANE, or a stored value of -99999. The minimum amplitude used to verify a gage measurement is 0.1mV This may need to be adjusted for some instrument types. When the AVW2xx is disconnected or otherwise unable to communicate with the MCU the Text Monitor will display a value of -99998. UserLoc(1) holds the output amplitude of the vibrating wire signal. This can be added to the Text Monitor (you ll need to turn off Auto Configure Locations in the Configure Preferences form of Logger to view this location). Additional metrics such as Signal-to-Noise Ratio (SNR) can be shown in the UserLocs by editing the instruction file for the selected age Type Make Model (press the gear button and remove the comment characters from the lines of programming). Follow these steps to resolve the commonly encountered issues: 1. Check all power connections. When using the RF4xx make sure the red PWR led is lit. 2. Check all wiring connections. Use the diagrams provided in this Application Note. 3. Use the Device Configuration software to check settings in the AVW2xx per instructions outlined previously. If using SDI-12 with directly connected AVW2xx s check the SDI-12 address setting. This should be set to 0. If using other interfaces double-check the PakBus ID. 4. If using a wireless deployment use the Device Configuration software to check that the radio and AVW2xx wireless settings match. The Hop Sequence and Net Address MUST MATCH. Also the Power Mode should match, other combinations to reduce power consumption should be tested thoroughly prior and during deployment. 5. If using a wireless deployment then check all antenna cabling and connections. Check signal strength using the RF4xx diagnostics. 6. If using multiplexers with the AVW2xx make sure the correct multiplexer Model is selected. If using the MCU to control multiplexers then select the model of the multiplexer attached. If using the AVW2xx to control to the multiplexers then make sure the multiplexer Model is set to AVW2xx. 7. Check that the age Type Make Model selected for each channel matches the wiring and AVW2xx configuration. Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21 Page 13 of 13