Solid-State Counter/Timer

Similar documents
Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

H3CA-8H-AC/100/110/120

Temperature Controller E5C4

H7ER H7ER-V H7ER-V1 H7ER-V2 H7ER-V3

Self-Powered Counters H7EC

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Special-Purpose Photoelectric Sensors

Cam Positioner H8PS. Plastic body, 2 m (6.56 ft.) cable Metal body, 2 m (6.56 ft.) cable

Solid-state Timer H3YN

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Model Number Structure

Miniature Inductive Prox TL-W

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Chip Immune Inductive Prox E2EZ

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

onlinecomponents.com

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Model Number Structure

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

masterelectronics.com onlinecomponents.com

Snap Action Switch. General- Low force 25 g D2F-FL D2F-FL-T D2F-FL-D D2F-FL-A D2F-FL-A1

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

SYSMAC Remote Transistor Module

DIN 48 x 48 Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative Transmissive LCD. The H7CX Defines a New Standard.

Multifunction Counter/Tachometer H7CX Series

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

E2EC-CR8D2 5.4 mm dia. 1.5 mm (0.06 in) NO E2EC-C1R5D1 NC. E2EC-C1R5D2 8mmdia. 3 mm (0.12 in) NO E2EC-C3D1 NC

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Plastic Cylindrical Inductive Prox

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

2. Actuator B: Ball type P: Pin type F: Flat type

Special-Purpose Proximity Sensor E2C


Chemical Resistant Inductive Prox

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

General-Purpose Photoelectric Sensor

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

I/O delay. (0.32 in ±0.06 in)

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Multifunction Preset Counter H7CX

Digital Timer Ultra-compact Timer Provides Advanced Functions and Security Settings. Features

onlinecomponents.com

Model Number Structure

Voltage Current Front-mounting bracket

Model Number Structure

S8VE (60/90/120/180/240-W Models)

Inductive Proximity Sensor

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Adjustable Capacitive Prox E2K-C

Capacitive Prox E2K-X

PRESET HOUR METER. FEATURES 1. Preset function equipped in half size (24 48 mm inch). 2. Display has backlight for instant recognition.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Mini Photoelectric Sensor

25 m 5 m 1 m. Part Number Mounting bracket. E39-LU1 Mounting bracket for E39-R1 reflector

Switching Power Supply

Capacitive Prox E2K-X

Miniature Inductive Prox TL-W

Inductive Proximity Sensor

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Digital Timer H5CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

Model Number Structure

Transistor I/O Link Modules

02/11/2015

Zelio Count - Counters RC87610

Switching Power Supply

Thread length (overall length) material

Inductive Proximity Sensor

Digital Counter H7CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

Solid State Relays with Failure Detection Function

TIMERS FOR ALL APPLICATIONS

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

E2K-C25MY1 E2K-C25MY2

Digital Counter. DIN 48 x 48 mm Counters with Easy-to-use Functions

Multi Voltage Options. Multi Voltage Options 110VAC + 24VAC/DC 230VAC + 24VAC/DC 24VAC/DC 110VAC 230VAC

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Model Number Structure

Solid-state Timers H3DK

S82S (3/7.5-W Models)

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

TIMERS FOR ALL APPLICATIONS

Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

Solid-state Timers H3DK

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Z-15GW2277 Z-15GW2277-B

Millenium II +: general characteristics

Special-purpose Basic Switch

Transcription:

Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD display Present Value: 8 mm (0.32 in) Set Value: 4 mm (0.16 in) Nonsignificant zeros suppressible from preset or count value display Selectable power supply voltages 24 to 240 VAC and 12 to 120 VDC Memory protection 4 programmable output modes available for both counter and timer functions Ordering Information Counter/Timer Mounting style Surface/flush mounting Operating function Preset counter/timer (selectable) Operating system (mode) Counter: reversible (Three input modes and four operating modes are selectable) Timer: time-limit operation, integrating operation (Four operating modes are selectable) Backup power supply for memory protection Provided: Approx. 10 years at 20 C (68 F) Number of counts 0 to 999999 (6 digits) Timing ranges 0.00 to 9999.99 s, 0.0 to 99999.9 min., 0.0 to 99999.9 h (6 digits) External connection Socket Display type 6-digit backlit LCD; 8 mm (0.32 in) Present Value, 4 mm (0.16 in) Set Value Count and reset input for counter function; reset and gate input for timer function No-voltage input (See Note.) (solid-state/contact input) Voltage input Control output Contact Solid-state Contact Solid-state Power supply/ AC 30 cps AL ALS ALV ALVS counting speed 1 kcps AH AHS AHV AHVS DC 30 cps DL DLS DLV DLVS 1 kcps DH DHS DHV DHVS Do not use the contact input at a counting speed of 1 kcps. 1

Accessories (Order Separately) Description Part number Sockets 11-pin Bottom surface or track mounting, top screw terminals P2CF-11 Bottom surface or track mounting, top screw terminals, finger safe terminal conforms to VDE0106/P100 Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P2CF-11-E P3GA-11 Panel mounting adapter Fits behind panel, ideal for side-by-side installation. Use P3G - sockets Y92F-30 NEMA 4 cover Waterproof front cover Y92A-48N Mounting track DIN rail, 50 cm (1.64 ft) length; 7.3 mm thick PFP-50N End plate Spacer DIN rail, 1 m (3.28 ft) length; 7.3 mm thick DIN rail, 1 m (3.28 ft) length; 16 mm thick PFP-100N PFP-100N2 PFP-M PFP-S Specifications Ratings Supply voltage AC 24 to 240 VAC, 50/60 Hz DC 12 to 120 VDC (20% max. permissible ripple) Operating voltage range 90 to 110% of rated voltage Power consumption (See Note 1.) Approx. 2.2 VA (at 240 VAC, 50 Hz) Approx. 1 W (at 120 VDC) Max. counting speed of CP1 and CP2 In counter function mode: 30 cps (contact and solid-state inputs): Minimum pulse width: 16.7 ms (ON/OFF ration: 1:1) 1 kcps (solid-state input): Minimum pulse width: 0.5 ms (ON/OFF ratio: 1:1) Reset system External reset (common to contact and solid-state inputs) and manual reset Minimum reset signal width: 20 ms Start and gate response time In timer function mode: Start and gate response time (common to contact and solid-state inputs): L-type: 16.5 ms H-type: 0.5 ms Count and reset inputs for counter function/ start and gate inputs for timer function Control output Approvals No-voltage input: (See Note 2.) Maximum short-circuit impedance: 1 kω Short-circuit residual voltage: 0.5 V max. (1.3 V max.) Minimum open impedance: 100 kω Voltage input: 5 to 30 V at High level 0 to 2 V at Low level Input impedance: Approx. 4.7 kω Contact output type: SPDT 250 VAC 3 A p.f.=1 (resistive load) Solid-state ouput type: Open collector 30 VDC max. 100 ma max. UL / CSA / SEV 1. On power application, the following inrush current flows for 0.5 ms. 3.7 A at 240 VAC, 2.3 A at 120 VDC 2. The source current output from each input terminal when using no-voltage input is 2 ma max. 2

Characteristics In timer Repeat accuracy ±0.05% ±0.05 s function mode Setting error ±0.1% ±0.005 s Variation due to ±0.05% ±0.05 s max. voltage change Variation due to temperature change Insulation resistance 100 mω min at 500 VDC Dielectric Strength 1,500 VAC 50/60 Hz for 1 minute Vibration Mechanical durability: 10 to 55 Hz, 0.75 mm (0.030 in) double amplitude Malfunction durability: 10 to 55 Hz, 0.3 mm (0.012 in) double amplitude Shock Mechanical durability: approx. 30 G Malfunction durability: approx. 10 G Ambient temperature Operating: -10 to 55 C (14 to 131 F) Storage: -25 to 65 C (-13 to 149 F) Humidity 35 to 85% RH Service life Mechanically: 10,000,000 operations min. Electrically: See Engineering Data Weight Approx. 130 g (4.59 oz) Operate time of output circuit is included in overall error. Engineering Data Electrical Service Life Resistive Load Inductive Load 1000 1000 Switching operations (x10 3 ) 500 100 250 VAC (p.f. = 1) 30 VDC (p.f. = 1) Switching operations (x10 3 ) 500 100 250 VAC (p.f. = 0.4) 30 VDC (L/R = 7 ms) 0 0 1 2 3 Load current (A) 0 0 1 2 3 Load current (A) 3

Timing Charts In Counter Function Mode In Timer Function Mode Count Output Modes In the timing charts below, A is the minimum signal width. B must be at least 1/2 of minimum signal width, otherwise, signals may not be counted if the minimums for A and B are not met. Command Input Mode A Count input 1 Individual Input Mode B Count input 1 Count input 2 Count input 2 Digitaldis play Digital display Phase Difference Input Mode C Count input 1 Enlargement from left. Count input 2 Digital display Counting speeds of CP1 and CP2 must be the same for Reversible C. 4

Functions of Input Signals Input type Counter output Signal high Signal low No-voltage Contact The contact turns ON The contact turns OFF Solid-state The open collector transistor is in the ON state The transistor is in the OFF state Voltage Both Input signal voltage level is 5 to 30 V Input signal voltage level is 0 to 2 V Input Counter mode A (command input) Count input: The count value is increased by one when count input 2 (CP2) voltage goes low. The count value is decreased by one when count input 2 (CP2) voltage goes up. Counter mode B (individual input) Output Modes in Both Counter and Timer Operations Counter mode C (phase difference) Timer operation Count input 1 Addition count input The count value is increased by Start input one when phase of count input 2 (CP2) is delayed with respect to phase of count input 1 (CP1). The count value is decreased by one when phase of count input 2 (CP2) is ahead with Count input 2 Addition/subtraction control Subtraction count input respect to phase of count input Gate input 1 (CP1). Output Mode N Present value display and outputs are maintained until reset. Reset Preset Digital display 0 Control output Output Mode F Present value runs continuously. Outputs are maintained until reset. Reset Preset Digital display 0 Control output Output Mode C Present value is placed in reset start status as soon as preset count is reached; the preset is not actually displayed. Outputs are one-shot, fixed at 0.5 second, and operate repeatedly. Reset Preset Digital display 0 Control output Output Mode R Present value display returns to reset start status after expiration of one-shot time period. Outputs are one-shot, fixed at 0.5 second, and operate repeatedly. Reset Preset Digital display 0 Control output Sustained control output One-shot control output, set to 0.5 second 5

Dimensions Unit: mm (inch) Counter/Timer 6 (0.24) 63.7 (2.51) 0.7 (0.03) 13.6 (0.54) Panel cutout 50 (1.97) 45 (1.77) 48 (1.89) 45 (1.77) 50 (1.97) 48 (1.89) 8 (0.31) 78 (3.07) Recommended panel thickness is 1 to 3.2 mm. Panel cutout conforms to DIN 43700. Accessories P2CF-11 Track Mounting/Front Connecting Socket Conforming to VDE0106/P100 Eleven, M3.5 x 7.5 sems 7.8 (0.31) 3 (0.12) 4.5 (0.18) Terminal arrangement Mounting holes Two, 5.4 dia. mounting holes 70 max. (2.76) 50 max. (1.97) Two, 4.5 dia. holes 31.2 max. (1.23) 35.4 (1.39) 40±0.2 P2CF-11-E Finger Safe Terminal Type Conforming to VDE0106/P100 Eight, M3.5 x 7.5 sems 7.8 (0.18) 5 4.5 (0.18) 3 70 max (2.76) Two, 4.5 dia. holes 1.2 35.4 (1.39) 40±0.2) 50 max (1.97) 31.2 max (1.23) P3GA-11 Back Mounting Socket Terminal arrangement 6

Y92F-30 Panel Mounting Adapter Adapter installs behind the panel. It is ideal for side-by-side installation. Use a P3GA-11 socket. Panel Adapter for panel mounting Y92F-30 P3GA-11 back connecting socket 58 (2.28) 48 (1.89) 8 (0.31) 91.9 (3.62) PFP-100N, PFP-50N Mounting Track PFP-100N2 Mounting Track 4.5 (0.18) 7.3±0.15 35±0.3 27±0.15 4.5 (0.18) 16 (0.63) 35±0.3 27 24 29.2 (1.15) 15 25 25 25 25 10 10 L 1 (0.04) 15 25 25 25 25 15 10 10 L 1 (0.04) 1.05 (0.06) L: Length 1 m PFP-100N 50 cm PFP-50N 1 m PFP-100N2 PFP-M End Plate PFP-S Spacer 16 (0.63) 6.2 (0.24) 10 (0.39) 1.8 (0.07) 5 (0.20) 12 50 (1.97) 35.5 1.8 35.3 (1.39) 44.3 (1.74) 34.8 (1.37) M4 x 8 11.5 pan head (0.45) 10 screw (10.39) 1.3 (0.05) 4.8 (0.19) 16.5 (0.65) 7

Nomenclature Key function: Output display Input mode display Output mode display Reset key Advance/Write key Present value display Set value display Power OFF display Power OFF display Setting key Resets the Present value display and the output. Sets the set value. Selects timer or counter function, and input and output modes. Selects the function and mode, and writes. Normally used to write, or advance one column when setting the set value. Programming Selecting Function Mode Select timer or counter function first. It is not necessary for power to be ON to set this function. When the is shipped, it is set to counter function, input mode A, output mode N, and preset value 1. 1. Terminals 1 and 3 must be connected to select timer or counter function using the key. Short circuit MODE is lit. The function, input mode, or output mode display will be blinking. (The Power OFF display will stop blinking when power comes ON.) 8

2. Press the key to select counter or timer function, input mode, and output mode. The characters below will flash when the key is pressed. Press the key until input mode A begins blinking. Select counter or timer function. A For the counter function, select the input mode. N Select the output mode. COUNTS hours min sec B C *Displayed automatically when the timer function is selected. F C R Press the key until the Press the key until the Press the key until the desired function appears. desired function appears. desired function appears. Press the key to write Press the key to write Press the key to write the desired input mode. the desired input mode. the desired input mode. Press the key. A will stop blinking, and one of the output modes will begin blinking. Press the key until output mode N begins blinking. Setting Example 1. Selecting the counter function with input mode A and output mode N. (Terminals 1 & 3 connected.) MODE lights on the display. COUNTS will begin blinking when the key is pressed. (Press the keys until the desired place is reached.) Press the key. COUNTS will stop blinking, and one of the input modes will be blinking. Disconnect terminals 1 and 3 before setting values. When terminals 1 and 3 are disconnected, the MODE display will turn OFF and output mode N will stop blinking. Always disconnect terminals 1 and 3 when finished selecting the function. Values cannot be preset if terminals 1 and 3 are connected. 2. Selecting the timer function with sec and output mode N. (Terminals 1 and 3 connected.) If set for timer, sec will begin blinking when the key is pressed. (Press the keys until the desired place is reached.) Press the key. sec will stop blinking, and one of the output modes will begin blinking. The INPUT MODE will automcally enter T. 9

Press the key until input mode N begins blinking. Press the key until the desired digit begins blinking. Disconnect terminals 1 and 3 before setting values. When terminals 1 and 3 are disconnected, the MODE display will turn OFF, and output mode N will stop blinking. Always disconnect terminals 1 and 3 when finished selecting the function. Values cannot be preset if terminals 1 and 3 are connected. Presetting Numeric Values Preset values after selecting the function. Values can be preset whether the power supply is ON or OFF. Press the key to set the desired value. Continue pressing the and keys until the smallest digit has been set. To complete presetting, press the key so that no place on the display is blinking. * Preset unnecessary higher digits at 0. (i.e. 000015) The output will go ON if the set value is 0 (0.0 or 0.00) and the displayed count is also 0 (0.0 or 0.00). In this case, press reset after presetting, and the output will go OFF. High-order digits Low-order digits key: Press this key to move to the next column. key: Press this key to increment values. 0 1 2 9 10

Connections Terminal Arrangements Power Supply Connection Connect power supply across terminals ➁ and ➉ and apply one of the specified voltages. (Pay special attention to the polarity when using a DC-operated model.) Reset input Count input 1 Count input 2 Power Supply 24 to 240 VAC (50/60 Hz) 12 to 120 VDC (-) (+) In Counter Function Mode When the control power supply is DC, terminals ➁ and ➂ are internally connected. Mode Switch (1 & ➂) When these terminals are short-circuited, set the input and output modes with the RESET key, not the MODE key.! Caution Do not touch the input terminals while power is supplied to the or you may experience an electric shock, since this counter does not have a built-in power transformer. Use of a model rated at a low DC voltage is recommended when the counter is installed at a location where the input terminals are easily accessible. Reset input Start input Gate input When connecting external signal input contacts and transistors, use a power supply having a power transformer whose primary and secondary circuits are isolated from each other with the secondary circuit not grounded, for the input devices, to prevent current feedback and short-circuiting. Correct: Power Supply Input terminals Power supply In Timer Function Mode When the control power supply is DC, terminals ➁ and ➂ are internally connected. Circuit Rectifier * Check the operating status of terminals ➂ and ➃ (see table below) before connecting or disconnecting them. Insulated transformer is necessary Timer Control Terminals ➂ & ➃ Be sure these terminals are not connected when using the as a counter. These terminals are used as shown below only when functions as a timer. Incorrect: Terminals ➂ & ➃ Short-circuited Open Operation Timer operation temporarily interrupted when power failure accurs in control power supply Timer operation continues even when power failure accurs in control power supply Circuit Input terminals Rectifier Power supply Grounding Autotransformer Do not arrange the peripheral circuits of the counter in either way, as the internal circuit may be destroyed, rendering the counter unoperational. To input a signal from a single input contact to several s at the same time, be sure to connect the terminals of the same numbers in parallel. 11

Connection of Load Circuit Control Output Contact Output Type Reset Input Connection Reset input contact (Resets the unit when turned ON.) Load Power supply for load (250 VAC max.) The load is turned on when the set count or time is up. Reset input NPN transistor (Resets the unit when turned ON.) Solid-State Output Type Load (+) Power supply for load (250 VAC max.) (-) Voltage Input Type (+) Reset input contact (Resets the unit when turned ON.) 30 VDC max. 1. The load is turned on when the set count or time is up. 2. Be sure to connect terminal 8 when an inductive load is connected. Output Delay Time The output delay time is the time from the application of the count input signal of the preset value until the generation of control output. The delay time differs depending on counting speed and model of control output used, as shown in the table below. Type of control output Max. counting speed of rated time Output delay time Contact output 30 cps Common to 30 ms max. 1 kcps hours, minutes and seconds 10 ms max. Solid-state output 30 cps 30 ms max. 1 kcps 2 ms max. (-) E (30 VDC max.)* R Reset input NPN transistor (Resets the unit when turned OFF.) *At High level 4.7 E 4.7 + R (V) 5 V Reset input PNP transistor (Resets the unit when turned ON.) 30 VDC max. 12

E (30 VDC max.)* R Reset input NPN transistor (Resets the unit when turned OFF.) *At High level 4.7 E 4.7 + R (V) 5 V 30 VDC max. (+) Input 2 Input 1 (-) (A count signal is input when turned ON) Connection of Count Inputs No-Voltage Input Type (+) 30 VDC max. R R Input 1 Input 2 (Counts when turned ON.) Input 1 Input 2 (-) (A count signal is input when turned OFF) * At High level 4.7E (V) 5V 4.7 + R Input 1 Input 2 (Counts when turned ON.) Voltage Input Type 30 VDC max. (+) Input 1 Input 2 (A count signal is input when turned ON) (-) 30 VDC max. (+) R R Input 1 Input 2 (-) * At High level 4.7E (V) 5V 4.7 + R (A count signal is input when turned OFF) 13

Operations Power Failure Detection The is capable of detecting and indicating a power failure on the display. Before power application or when a power failure occurs, the PW OFF display flickers indicating that the control power supply is off. Relation Among t 1, t 2, and Supply Voltage Likewise, on power application, there is a period during which the counter does not respond to the input signal, as show below, because of a lag in the rise in the internal circuit voltage. Operation and Display When a power failure occurs, there is a period during which the counter does not respond to the input signal, as shown below, because of the lag in the rise in the internal circuit voltage. OUT is displayed when counting or timing is complete. When MODE lights on display, terminals 1 and 3 ae connected. In this case, it is not possible to preset values. Be sure to disconnect the terminals. The uses regular read format, so the preset values can be changed whether power is ON or OFF. When changing the preset value during timer or counter operation, a signal will be output when the new value is the same as the displayed value. The front panel keys operate at a touch. Do not press the keys with excessive force or tools, such as a screwdriver. Press only with fingers. After presetting values, part of the display might be blinking. The will operate normally in this condition, but press the key so that characters do not blink. Mounting There is no limitation in mounting direction. However, avoid mounting the unit at an angle. Surface Mounting Using P2CF-11 Front Connecting Socket When a number of the are mounted in a vertical line or when an is mounted close to an obstacle such as a wiring duct, be sure to provide a separation of approximately 20 mm (0.79 in) between adjacent units or between the unit and the obstacle to allow room for engagement and disengagement of hooks as shown below. Wiring duct, etc. Panel Mounting Using Y92F-30 Adapter for Flush Mounting Insert the into a square-cut hole from the front of the mounting panel; insert the adapter from the rear of the until the clearance between the panel surface and the adaptor is minimized. Then secure the with two screws onto the panel. Y92F-30 + Adapter P3GA-11 Hook 20 105.7 8 91.9 Panel P2CF-11 14

When mounting two or more counters in a vertical line, arrange all the adapters so that the molded springs of the Y92F-30 adapters are positioned on the right and left sides. Removal To remove an panel mounted witha Y92F-30 adapter, loosen the two screws of the adapter, pry up the top and bottom hooks of the adapter, and pull the out from the front of the panel. Molded spring When mounting two or more counters in a horizontal line, arrange all the adapters so that the molded springs of the Y92F-30 adapters are positioned on the top and bottom sides.! Caution The has a built-in lithium battery. Be sure to dispose of the old properly, as lithium batteries are likely to explode if incinerated. Molded spring By attaching the P3GA-11 back connecting socket to a panel mounted, wiring can be performed in the same manner as the front connecting socket. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4 OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. No. GC TMCN1 3/02 Specifications subject to change without notice Printed in USA 15