User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

Similar documents
User Guide. ExStik FL700. Fluoride Meter

User Guide. Moisture Meter. Model MO250

User's Guide. Datalogging Light Meter with PC Interface. Model

User's Guide. Cup Thermo-Anemometer. Model AN400

User's Guide. Model Laser Photo Tachometer

User's Guide. Video Borescope. Model BR100

User s Manual. Model and Sound Level Calibrators

Digital Vane Thermo-Anemometer Model

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Mini Photo Tachometer Model Mini Contact Tachometer Model

Heavy Duty Datalogger Module

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

Heavy Duty Datalogging Light Meter

Heavy Duty Mini Vane CFM Thermo Anemometer

SoilStik ph Meter PRODUCT MANUAL

Laser Photo/ Contact Tachometer. m/min. ft/min

True RMS AC Voltage/Current Datalogger

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

Heavy Duty Vibration Meter

User's Guide. Heavy Duty Differential Pressure Manometer. Model

Heavy Duty CFM Thermo-Anemometer Model

User's Guide. Model High Precision Quad Output DC Power Supply

User's Manual Sound Level Alert Model SL130

SuperHeat Psychrometer Models RH350 and RH355 (kit)

User's Guide. Hot Wire Thermo-Anemometer Model

User's Guide. Digital Sound Level Meter. Model

User's Guide. ExStik EC400. Conductivity / TDS / Salinity / Temperature Meter MODE HOLD

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

User's Guide Video Borescope Model BR200

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

User's Guide. Phase Sequence and Motor Rotation Tester Model

Heavy Duty Datalogger Module

3-Axis G-Force Datalogger

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

User's Guide. Vibration Meter and Laser Combination Tachometer Model

User Guide. ExStik II EC400. Conductivity / TDS / Salinity / Temperature Meter

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

User's Guide. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500

EC/TDS/SAL TRACERTM POCKETESTER CODE Conductivity/TDS/Salinity/Temperature/Meter

User's Guide. Temperature / Humidity Datalogger. Model 42270

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

Heavy Duty Psychrometer + IR Thermometer Model HD500

User's Guide. Extech AM A AC Analog Clamp Meter

Integrating Sound Level Datalogger Model

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter

Tracer TM Salt/EC/TDS PockeTester Code 1749

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

Visit us at Back to the Extech DO600 Product Page

User's Guide. Mini Microscope. Model MC108

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at

Hygro Thermo-Anemometer Model

Digital Sound Level Meter

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

Mini Digital Multimeter

User's Manual. Digital Sound Level Meter. Model

Tracer ph/tds/salt PockeTester TM Code 1766

Power Analyzer Datalogger Model

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2

WK7200. Water Quality Test Kit USER S MANUAL

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

WalkLAB ph mv/orptemperature

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

USER GUIDE. Salinity Meter Pen Style Water Quality Meter. Model EC170

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Tracer ph/tds/salt PockeTester TM Code 1766

Dual Input, 3-Display Thermometer/Datalogger Model

Operations Manual EcoSense ph100

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

HI HI N HI HI

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

Operation Manual. MODEL ph 630. Microcomputer Based ph&temperature Pocket Meter. ph630

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Operation Manual. MODEL ph/ec80. Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter. ph/ec80

Conductivity and TDS Meter Pen Style Water Quality Meter

DO Meter Kit. Instruction Manual

24-hour Continuous Field Monitors

Large Display Salinity & Conductivity Pens &

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200 UNITS NEXT AREA RECALL. cf m/cmm Anemometer Thermometer AN200

ph/orp Meter SD Card real-time Datalogger

DIGITAL POCKET HEAT INDEX MONITORS USER S MANUAL

USER MANUAL AD 630 DO & Temperature Waterproof Meter with Galvanic Probe

USER MANUAL AD 630 DO & Temperature Waterproof Meter with Galvanic Probe

HI HI N HI HI

Autoranging Mini Multimeter Model MN16A

Bante 221 Portable ph/orp Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 510B/511B RTD Simulator Operating Instructions

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

DPH230SD USER S MANUAL

Transcription:

0 User Guide ExStik TM Model RE300 Waterproof ORP Meter Patent Pending 500 MV 1000 TM RE300 ORP

ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE button 4. CAL button (unused on RE300) 5. ON/OFF button 6. Electrode collar 7. Electrode (Electrode cap is not shown) 1 2 3 4 5 6 7 Display Description 3 1. Reading 2. Units 3. Bargraph 4. Data Hold 5. Scale 6. Low Battery 5 2 1 4 6 2

Operation Getting Started White KCL crystals may be present on the electrode. These crystals will dissolve in the soak or they can be simply rinsed with tap water When the RE300 is turned on, it enters the Automatic Calibration mode. SELF and CAL will appear on the LCD while calibration is in progress. After the calibration is complete, SELF and CAL will extinguish and both the main display and bargraph will read ORP in mv units. The bargraph reads 0mV (far left), 500mV (center), and 1000mV (far right). ORP Testing 1. Remove cap from the electrode and press the ON/OFF button to switch the RE300 on. 2. Dip the electrode1/2 to 1 into the test solution. Stir once and let the reading stabilize for 1 to 3 minutes. 3. Note the ORP or press MODE to freeze the reading The HOLD display icon will appear along with the held reading. The held reading will be stored in the next 15- reading storage location (see below). Press the MODE key to return to normal operation. 4. Press the ON/OFF button to turn the RE300 off. If you do not press a button for 10 minutes the RE300 shuts off automatically. 15-Reading Measurement Storage 1. Press the MODE button to store a reading. The LCD will briefly display the memory location number and then the value stored (Data Hold will activate). 2. Press MODE again to return to normal operation. Repeat step 1 above to store the next reading and so on. 3. If an attempt is made to store more than 15 readings, the stored readings (starting with the first reading) will be overwritten. Recalling Stored Readings Note: First ensure that the HOLD symbol is not displayed. If it is, exit the HOLD function by pressing the MODE button. 1. Press the CAL button once and then press the MODE button immediately after CAL is displayed; the location number (1 through 15) will flash. If the CAL mode is accidentally accessed (display flashing), press the CAL button again to exit. 2. The last stored reading taken will be displayed first. To advance through the stored readings, press the MODE button. The location number is displayed first, followed by the reading stored in that location. 3. To exit the storage mode, press the CAL button and the ExStik TM will return to normal operation. 3

Measurement and Display Considerations If the unit appears to be locked (display frozen). It is possible that the Data Hold mode has been inadvertently accessed by pressing the MODE button. Simply press the MODE button again or turn the meter off and restart if the display appears frozen. If the meter does latch up and no button presses revive it, remove the batteries and restart. Note that if the batteries are removed, any stored readings will be discarded. Factory calibration data for all models will be retained, however. Replacing the Electrode To preserve Electrode life keep the sponge in the protective cap soaked with tap water when not in use (store vertically). DO NOT USE DE-IONIZED WATER. 1. To remove an electrode, unscrew and completely remove the electrode collar (turn the collar counter-clockwise to remove). 2. Gently rock the electrode from side to side, pulling it downwards, until it disconnects from the meter. 3. To attach an electrode, carefully plug the electrode into the meter socket (note that the electrode connector is keyed, ensuring proper connection). 4. Tighten the electrode collar firmly enough to make a good seal (a rubber gasket seals the electrode with the meter). Powering the ExStik The ExStikTM uses four (4) CR2032 batteries (included).. If the batteries are weak, the BAT indicator appears on the LCD. Press the ON/OFF key to turn the ExStikTM on or off. The auto power off feature shuts the ExStikTM off automatically after 10 minutes of inactivity to preserve battery life. 4

Battery Replacement 1. Twist off the battery compartment cap 2. Replace the four (4) 2032 batteries observing polarity. 3. Replace the battery compartment cap Optional Accessories Replacement ORP electrode (Part Number: RE305) Specifications Display Operating conditions ORP Range / Accuracy Measurement storage Power Low battery indication Auto power off Multifunction LCD with Bargraph 32 to 122 o F (0 to 50 o C) / < 80% RH ± 999mV / ± 4mV 15 tagged (numbered) readings Four (4) CR2032 button batteries BAT appears on the LCD After 10 minutes of inactivity 5

Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Copyright 2005 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form. 6