MSD Three Stage Delay Timer PN 7760

Similar documents
MSD Advanced RPM Control Module PN 7761

Adjustable Timing Control PN 8680

Flying Magnet Crank Trigger Kit General Wiring

Adjustable Timing Control PN 8680

MSD IGNITION FOR THE BOMBARDIER DS 650 QUAD PN /PN 4205

Pro Mag A/Fuel Power Grid Controller PN 8772

MSD Enhancer Ignition for the Honda TRX400EX PN /PN 4203

MSD Programmable Launch RPM Controller

Proliphix EPA-60 Installation Guide

MTX-A, Fuel Pressure Gauge PSI

MTX-A Temperature Gauge User Manual

3.5 inch Hard Drive Enclosure. Model #: HDE350U. User s Manual

3.5 inch Hard Drive Enclosure. User s Manual

Digital Keychain 1.4 LCD

INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH

IRRIGANDER 4 SPLITTER SWITCH

2.4GHz Wireless Optical Mouse

AVANT REM Speech Manual Rev. 1 Effective 10/05

TOUCHBOX. iphone I N S T R U C T I O N M A N U A L

DataPort 250 USB 2.0 Enclosure User s Guide (800)

USB 2.0 LR 4-Port Extender

Woolich Racing. USB ECU Interface User Guide

USB 2.0 LR Extender. EXT-USB2.0-LR User Manual.

MINI 4200 Model # - C Mini Instruction Manual V.2. This instruction manual serves as a guide for the Mini 4200.

Kanguru QSSD External SSD USB3.0 User Manual

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

Bluetooth Wireless Technology Enabled Optical Mouse

MODEL 710. Ground Support Intercom INSTALLATION/OPERATION MANUAL

User Guide SERIAL #:

HC900 Remote Termination Panel (RTP) For Relay Outputs

CarDAQ-M J2534-1&2 Module Quick Start Guide

ACT-IR210L IrDA Motherboard Adapter. User s Manual

Superchips 1705 MAX MicroTuner Ford Powerstroke 7.3L Turbo Diesel Vehicles Vehicle Programming Instructions

Bluetooth Cell/Smart-Phone/ GPS/Radar Integration Kit for Harley Ultra Driver Headset Position CFBR-HRUC

PROGRAMMABLE IR 8 BUTTON PANEL

Bluetooth Cell/Smart-Phone/ GPS/Radar Integration Kit for Harley Ultra Driver Headset Position CGBH-HRUC

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

ME15 Magnetic Encoder Manual Revision 1.1

Blackrock 32-Channel Cabrio Butterfly Ref Adapter Instruction for Use

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking

User Manual Version 1.0

DataPort 350 & 525 USB 2.0 and FireWire Enclosure User s Guide (800)

Checking the Package Contents

Sonic Ruptor 400. User Manual

INTELLIGENT DOCKING STATION USERS MANUAL

Irrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.

Instruction Manual. 20 memories time switches

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

Seven Channel Remote Control

USB-A to Serial Cable

American DJ AVIATOR-SP8. Introduction. User Instructions

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

FD141CV-C-1. Installation and Operation Manual. 14 Widescreen HD Display. Revision Date: 05/04/2017 Page 1 of 15. Rev: B

ACT-IR100M+/100M IrDA IR Printer Adapter

Source Audio External Tap Tempo Footswitch User s Guide

KE18 PC Keyboard Encoder User Manual

AI Light Bar Part # Feniex AI Instruction Manual / feniex.com

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

6001TA Terminal Adapter Installation Instructions

Illuminate 25 Light Starter Kit What s included Light String Control Box Spare Fuses Safety Instructions Quick Start Guide

DA-VINA 2534 User s Manual

OCEANIC SYSTEMS MULTIPLE ENGINE DISPLAY Part Numbers: 4161 USER MANUAL

FDCCM1-MM-L & FDCCM1-MM-R

Thank you for your purchase.

Hi-Tech Transport Electronics, Inc. DUAL LEVELING VALVE PROCESSOR INSTALLATION MANUAL. For the 4600 Scale System For the 5600 Scale System

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

Quick Installation Guide TU2-700

SMART SWITCH. User s Manual. This product is to be used with the MySmartBlinds automation kit.

TeraJet DOCSIS Modem Installation. Guide

Operating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World!

Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL

AI-0817, AI-1417, AI-2017, AI-2717, AI-3317, AI-4017, AI-4617, & AI-5217

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Quick Installation Guide TEW-AI07OB

Trimble S6 and SPS700 Total Station Firmware

NT1B-300 Rack Installation Instructions

Bluetooth Ceiling Fan Control with App Owner's Manual

INSTRUCTION MANUAL FN-8118 SCAN HERE

V8/V80. Installation manual. Version 5.0

Quick Installation Guide TK-407K

MP3 Speaker USER GUIDE

Owner s Manual. Industrial-Grade USB 3.0 Hub. Models: U IND (4-Port), U IND (7-Port), U IND (10-Port)

User Guide. Control Box. RoscoLED TM.

USER S MANUAL. QS2 USB2.0 QS2 USB2.0/eSATA Combo and QS2 USB2.0/eSATA/Firewire Combo Models

Installation and Operation Instructions

INSTRUCTION MANUAL. AquiStar GDL. Dissolved Oxygen Datalogger

SECURE/NONSECURE LED SIGN USER MANUAL

Nixeus Technology, Inc

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

3.5 External IDE Drive Case

Elapsed Timer Control Panel

USB Audio Converter. Installation and Operation Manual. USB to Analog Audio Converter Stancliff Road Houston, Texas 77099

User s Guide. POWERVAR Single Phase Power Conditioners

ACT-IR210L IrDA PC Adapter. User s Manual

ACLD Channel Opto-isolated Digital Input Board

Transcription:

MSD Three Stage Delay Timer PN 7760 ONLINE PRODUCT REGISTRATION: Register your MSD product online. Registering your product will help if there is ever a warranty issue with your product and helps the MSD R&D team create new products that you ask for! Go to www.msdperformance.com/registration. Parts Included: 1 - Module 1 - Parts Bag Required Items for Operation: MSD Power Grid - PN 7730 MSD CAN-Hub - PN 7740 The MSD 3-Stage Delay Timer is an add on module for the Power Grid ignition controller. This module allows for three additional RPM/Time Switch outputs similar to the RPM/Time switch function built into the Power Grid (Brown/White wire). INSTALLATION The 3-Stage Delay Timer module should be securely mounted near the MSD CAN-Hub. Plug the 3-Stage Delay Timer CAN connector to an available port on the MSD CAN-Bus Hub, PN 7740. Do NOT cut the CAN-Bus connector wires. The output wires will switch to ground any time the 3-Stage Delay Timer is programmed to activate by Time/RPM/ or both settings. The output circuit is a low current circuit designed to be used with a relay or activation switch. The output wires should not be connected directly to solenoids or lights (Figure 1). TM LED * EXAMPLE BELOW SHOULD BE FOLLOWED FOR EACH STAGE. PN 7760 3 STAGE DELAY TIMER CONTROL * BROWN WHITE ORANGE SOLENOID MSD PN 8961 RELAY 87A 86 87 TO GROUND 85 30 MSD CAN 12V 12V Figure 1

2 INSTALLATION INSTRUCTIONS WIRING Leading Group Wire Color Function Description 6-Pin CONN RED 22ga. MSD CAN HI BROWN 22ga. SHIELD RED 18ga. POWER BLACK 22ga. MSD CAN LO BLACK 22ga. MSD CAN GND Loose Wires BROWN STAGE 1 ORANGE STAGE 2 WHITE STAGE 3 Recieves 12V switched from Power Grid Controller. Also communicates between modules and Power Grid System Controller. This connector is only used with modules added onto the system. These wires switch to a low current ground when activated. Should be used in conjunction with a relay. Figure 1 OPERATION To program the 3-Stage Delay Timer module start MSD View and connect to the 7760 with the ignition on. Turn on ignition power Connect 7730 to PC via USB Start MSD View In the Connect box select 7760 Click Connect MSD View will display three tabs 1, 2, 3. Each tab corresponds to each output wire. RED LED The LED indicates that the module is communicating with MSD View. Without a connection to a PC or Laptop the LED will be "Off". OUTPUT SWITCH 1, 2, 3: RPM Switch: There are two settings for this function Enabled/ Disabled. Default value is Disabled. To activate the RPM ON/OFF function change the value to Enabled. RPM ON/RPM OFF: These settings can range from 0-15000RPM. If the RPM ON setting is set below the RPM OFF setting, the RPM Switch functions as a window switch, and will activate the output wire when RPM increases above the RPM ON setting. The output wire will deactivate once the RPM increases above the OFF setting (Figure 2). Figure 2

INSTALLATION INSTRUCTIONS 3 Figure 3 If the RPM ON settings is programmed with a value higher than the RPM OFF setting, the RPM switch functions as a hysteresis switch. The RPM switch will remain off until RPM increases above the ON setting. The RPM Switch will remain active until the RPM decreases below the RPM OFF setting (Figure 3). Time Switch: There are two settings for this function Enabled/ Disabled. Default value is Disabled. To activate the Time function change the value to Enabled Activation Point: The setting can range from 0.00-30.00sec. This setting determines when the output wire will activate after the launch wire is released from 12v. If this setting is set at 0.00 the output wire will activate as soon as the launch wire is activated with 12v. Duration: This setting can range from 0.00-30.00sec. This setting determines how long the output wire will remain active after the Activation Point setting has been met. This setting will start counting down after the launch wire has been released (in the event the Activation Point is set at 0.00).

4 INSTALLATION INSTRUCTIONS Figure 4 Example: If the Time Switch function is used with an electric shifter to shift the transmission into 2nd gear or High gear 0.70 seconds into the run with a duration of.030, figure 4 illustrates how the function works in relation to time figure 4. For most shifter applications 0.25-0.30 seconds is adequate time for the transmission to shift. Setting the duration with a lower time could cause inconsistent shifting issues. Setting the value higher could cause issues with wasted CO2 (Air shifter) or a stuck plunger (electric shifter). In most cases the shifter gate will prevent the shifter from advancing further without the shifter plunger returning to the static position (Figure 4). Note: Both the RPM and TIME Switch settings can be enabled at the same time. If both are enabled at the same time, both RPM ON and Activation Point settings must be met before the output wire will activate to ground. Be aware of the settings when both the timer and RPM settings are enabled as the duration timer will start at the activation point regardless if the RPM condition has been met or not. This can lead to erratic output wire results.

INSTALLATION INSTRUCTIONS 5 Data Acquisition: There are two settings for this function Enabled/ Disabled. Default value is Disabled. To activate the Data Acq. function change the value to Enabled. This enables the capture of the output wire activation in the MSD REVIEW only (Figure 5). Figure 5

6 INSTALLATION INSTRUCTIONS TECH NOTES

INSTALLATION INSTRUCTIONS 7 TECH NOTES

TECH NOTES Service In case of malfunction, this MSD component will be repaired free of charge according to the terms of the warranty. When returning MSD components for warranty service, Proof of Purchase must be supplied for verification. After the warranty period has expired, repair service is based on a minimum and maximum fee. All returns must have a Return Material Authorization (RMA) number issued to them before being returned. To obtain an RMA number please contact MSD Customer Service at 1 (888) MSD-7859 or visit our website at www.msdperformance.com/rma to automatically obtain a number and shipping information. When returning the unit for repair, leave all wires at the length in which you have them installed. Be sure to include a detailed account of any problems experienced, and what components and accessories are installed on the vehicle. The repaired unit will be returned as soon as possible using Ground shipping methods (ground shipping is covered by warranty). For more information, call MSD at (915) 855-7123. MSD technicians are available from 7:00 a.m. to 5:00 p.m. Monday - Friday (mountain time). Limited Warranty MSD warrants this product to be free from defects in material and workmanship under its intended normal use*, when properly installed and purchased from an authorized MSD dealer, for a period of one year from the date of the original purchase. This warranty is void for any products purchased through auction websites. If found to be defective as mentioned above, it will be repaired or replaced at the option of MSD. Any item that is covered under this warranty will be returned free of charge using Ground shipping methods. This shall constitute the sole remedy of the purchaser and the sole liability of MSD. To the extent permitted by law, the foregoing is exclusive and in lieu of all other warranties or representation whether expressed or implied, including any implied warranty of merchantability or fitness. In no event shall MSD or its suppliers be liable for special or consequential damages. *Intended normal use means that this item is being used as was originally intended and for the original application as sold by MSD. Any modifications to this item or if it is used on an application other than what MSD markets the product, the warranty will be void. It is the sole responsibility of the customer to determine that this item will work for the application they are intending. MSD will accept no liability for custom applications. 2015 MSD LLC FRM32010 Revised 01/15 Printed in U.S.A.