ENCL-MZ800-WAL ENCL-MX800-PAN MNL TAC I/A Series MicroNet MN 800 Series Controller Installation Instructions. Application.

Similar documents
DS A 10/99 MN 500 I/A SERIES MICRONET MN 500 CONTROLLERS APPLICATION SPECIFICATION

MNL-V1RVx MNL-V2RVx. Application. Model Chart. TAC I/A Series MicroNet Variable Air Volume Controllers Installation Instructions

MN-Sx, MN-SxHT, MN-S4-FCS, and MN-S4HT-FCS TAC I/A Series MicroNet Sensors General Instructions

DS A MN LCD I/A SERIES MICRONET LCD APPLICATION SPECIFICATION

IQ-SBS LCU Series Installation Instructions

TECH/DATA SHEET. Application. Model Chart. Installation. slon-v1. slon-v2. slon VAV Controller

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

Support for Non-Ultra2 SCSI Devices

68-pin Internal Ultra160-LVD Connector. Adaptec SCSI Card 29160N

Allworx Tx 92/24 Telephone Expander Installation Guide

T775S Series 2000 Expansion Module

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

2 Mesa Ethernet Dock User s Manual

MicroTech II TM Remote I/O Panel Installation Manual

INSTALLATION INSTRUCTIONS

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

Safety and Radio-Frequency Interference

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

HD40H(X) Performance Series Camera. User Guide

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

rcc.1081 Installation Instructions

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

Content. Product Description

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

Fast Ethernet Switch AT-FS705L. Installation Guide Rev. A

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

NSD/M1 Installation Instructions

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions

LN Series Remote Input/Output (I/O) Modules

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

MicroTech II Remote I/O Panel Installation Manual

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

LTEC Heat Pump DDC Controller

SySTIUM TM TECHNOLOGIES Model 215

Control different load types with one device

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

InnoMedia ipbx-400. Quick Install Guide.

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

CSM200 Expansion Tray

Now with Picture Memory

SANnet II Family Safety, Regulatory, and Compliance Manual

MN550. Satchwell APPLICATION SPECIFICATION

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide

FCC Regulatory Information

About Your AirPort Card Includes general information about the AirPort Card and AirPort software

Excel Smart I/O Compact

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

INSTALLATION INSTRUCTIONS

LTEC Unit Ventilator DDC Controller

Verify Package Contents

HDMI and USB KVM Extender

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

Satellite INSTALLATION GUIDE

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

Raven Series Standalone Media Converters

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Unity 100-watt Bridgeable Power Amp

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

Innovative Circuit Technology Ltd.

Installation Instructions RF5010 and RF5210

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

5 B&W Rear View System Camera

ADL-100 Operator s Manual

MicroTech II Chiller Unit Controller LonWorks Communication Module

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

Installation Instructions RF5010 and RF5210

InnoMedia ESBC B. Quick Install Guide. 1

7800 SERIES S7810B Multi-Drop Switch Module

SB Channel Soundbar with Built-in Subwoofer

InnoMedia ESBC B. Quick Install Guide. 1

SAFETY WARNINGS AND GUIDELINES

3M Wrist Strap and Ground Monitor 773. User s Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide

3M RFID Tracking Pad Model 770

NA502 Multiple RF Home Gateway

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Add 10/100 copper ports to a High Density Media Converter Chassis.

FRG-3105 Series Residential Gateway

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

ACCESS 9340/9360 Meter Input/Output Module

USER GUIDE. Element Wireless Smart Plug Model: E1C-NB6

Dual-Bay Drive Enclosure for msata SSD Drives - USB 3.1 (10Gbps), USB-C - RAID

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

BAR-USB-SW. Installation Guide. Barcode Swipe Reader. and BAR-USB-SWI

Transcription:

TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com ENCL-MZ800-WAL ENCL-MX800-PAN MNL-800-101 TAC I/A Series MicroNet MN 800 Series Controller Installation Instructions Application The TAC I/A MicroNet 800 Series Controllers are programmable, interoperable, LonWorks based control devices. The MN Series Controller features eight universal inputs, four analog outputs, eight digital outputs, a 5.1 volt reference, LED indication, and support for TAC MicroNet MN-Sx Sensor Link (S-Link) sensors. Additionally, network capability is provided through the use of a FTT-10 transceiver allowing the controller to communicate to other devices as part of a LonWorks Free Topology Communications network. A direct connection to a WPA-LON WorkPlace Communication adapter and a PC with TAC WorkPlace Tech Tool software is necessary to download and modify applications. Typical applications include central station air handlers, VAV air handlers, fan coil units, unit ventilators, and cooling towers. ENCL-MZ800-WAL Wall-Mount Enclosure Model Chart Model ENCL-MZ800-WAL ENCL-MZ800-PAN MNL-800-101 Description Wall-Mount Enclosure Panel-Mount Enclosure Controller Card with Backed-up Time Clock MNL-800-101 Controller Card ENCL-MZ800-PAN Panel-Mount Enclosure Printed in U.S.A. 9-06 Copyright 2006 TAC All Rights Reserved. F-26724-3

Applicable Documentation F-Number Description Audience Purpose F-26277 F-26303 F-26580 F-26507 F-26304 F-26363 Installation Inspection TAC I/A Series Micronet MN-SX Series Sensors General Instructions TAC I/A Series MicroNet System Overview TAC WorkPlace Tech Tool Engineering Guide TAC I/A Series MicroNet System Engineering Guide TAC WorkPlace Tech Tool User s Guide EN-206 Guidelines for Powering Multiple Full- Wave and Half-Wave Rectifier Devices from a Common Transformer Provides step-by-step installation and checkout procedures for TAC I/A Series MicroNet MN-SX Series Sensors. Also contains instructions for sensor operation. Provides an overview of the TAC I/A Series MicroNet System. It includes brief descriptions of the hardware and software components, and how they may be combined to create TAC MicroNet networks and stand-alone systems. Provides engineering and technical information for applying and using all aspects of TAC WorkPlace Tech Tool. Provides engineering and technical information to assist in designing a complete TAC MicroNet controller system using different architectures, components, and software. Provides step-by-step instructions for using TAC WorkPlace Tech Tool. Offers guidelines for avoiding equipment damage associated with improperly wiring devices of varying rectifier types. Contains instructions for identifying device rectifier type, guidelines for correctly powering devices of varying rectifier types, and examples illustrating proper power wiring techniques. Inspect carton for damage. If damaged, notify carrier immediately. Inspect controllers for damage. Return damaged products. Requirements (These items not provided): Installer must be qualified, experienced technician. Job wiring diagrams Tools Drill and bits for panel mounting screws Digital Volt-ohm meter (DVM) Static protection wrist strap Class 1 or Class 2 power transformer supplying a nominal 24 Vac (20.4 to 30 Vac) with a minimum rating of 20 VA, 50/60 Hz per controller plus Digital Output (DO) loads (if same transformer is used). In European Community, transformer must conform to local standards. Terminators One LON-TERM1 terminator required for free topologies Two LON-TERM2 terminators required for bus topologies Precautions Warning: Electrical shock hazard! Disconnect power before installing or removing the cover. Follow Static precautions when installing this equipment. Use copper conductors that are suitable for 167 F (75 C) Make all connections according to electrical wiring diagram, national and local electrical codes. 2 Copyright 2006 TAC All Rights Reserved. F-26724-3

Static Precautions Static charges damage electrical components. The microprocessor and associated circuitry are extremely sensitive to static discharge. Use the following precautions when installing, servicing, or operating the system. Work in a static-free area Discharge static electricity by touching a known, securely grounded object. Use a wrist strap connected to earth ground when handling the controller s printed circuit board. Federal Communications Commission (FCC) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and may cause harmful interference if not installed and used in accordance with the instructions. Even when instructions are followed, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception-- which can be determined by turning the equipment off and on-- the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/television technician for help. Canadian Department of Communications (DOC) This class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numerique de la classe [B] respecte toutes les exigences du Reglement sur le material broilleur du Canada. European Community Directives This equipment meets all requirements of European Community Directives for Low Voltage (72/23/EEC) and Electromagnetic Compatibility (89/336/EEC). Caution: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Location These controllers are suitable for indoor use only. Caution: Avoid locations where excessive moisture, corrosive fumes, vibration, or explosive vapors are present. Avoid electrical noise interference. Do not install near large contactors, electrical machinery, or welding equipment. Locate where ambient temperatures do not exceed 140 F (60 C) or fall below -40 F (- 40 C) and relative humidity does not exceed 95% or fall below 5%, non-condensing. Mounting Panel Mount Installation (ENCL-MZ800-PAN) ENCL-MZ800-PAN uses a sheet metal mounting plate. The enclosure has four mounting holes. Mount in a vertical position as shown in Figure-1. Allow access for wiring and removal of the assembly for service. Use the mounting holes provided. F-26724-3 Copyright 2006 TAC All Rights Reserved. 3

Caution: Drilling holes in the controller or mounting plate voids warranty. Do not drill into mounting plate or any other part of controller. Metal chips and other debris may short-circuit electronic components. 1. Select mounting location. 2. Using four #8 pan head screws, mount base of controller to a panel. 3. Wire controller (See Wiring section). 4. After wiring, remove aluminum cover plate. 5. Remove protective tape from edge of card connector. 6. Install printed circuit board. (See MNL-800-101 Printed Circuit Board Installation.) Figure-1 ENCL-MZ800-PAN Panel Mounting Dimensions. Wall Mount Installation (ENCL-MZ800-WAL) ENCL-MZ800-WAL use sa sheet metal enclosure. The enclosure has four mounting holes and eight combination knockouts (1/2" to 3/4") (See Figure-2). Mount in a vertical position and allow access for wiring and removal of the printed circuit board assembly for service. Use the mounting holes and knockouts provided. Caution: Drilling holes in the controller or enclosure voids the warranty. Do not drill into the enclosure or any other part of the controller. Metal chips and other debris may short-circuit electronic components. 1. Select mounting location. 2. Remove cover. 3. Using four #8 pan head screws, mount controller. 4. Wire controller (see Wiring section). 5. Remove protective tape from edge of card connector. 6. Install printed circuit board. (See MNL-800-101 Printed Circuit Board Installation.) 4 Copyright 2006 TAC All Rights Reserved. F-26724-3

Figure-2 ENCL-MZ800-WAL Wall Mounting Dimensions. Wiring See Figure-3 for terminal connections. A power transformer supplying a nominal 24 Vac (20.4 to 30 Vac) with a minimum rating of 20 VA, 50/60 Hz per controller is required. The supply to the transformer must be provided with a circuit breaker or disconnect. Use class 1 wiring for the transformer wiring. Figure-3 Terminal Connections. F-26724-3 Copyright 2006 TAC All Rights Reserved. 5

Caution: Do not install the low voltage input/output wiring (UI/AO) in the same conduit with power or DO wiring with a potential greater than 30 Vac rms. Use shielded cable if the low voltage input/output wiring (UI/AO) is installed in the same conduit with power or DO wiring with a potential less than 30 Vac rms. Do not use the inside of the sensor enclosure or the wiring compartments of the MN 800 as a junction box for other control circuits. Although not required, shielded cable may used for AI, DI, and AO wiring. Fold the foil shield back over the cable jacket and compress it at the point of entry or exit of each controller. Use a sheathed cable connector in the knockout at the point of entry or exit. After the entire system has been installed and wired, verify wiring with the use of a DVM to insure against wiring errors, overvoltage, or short circuits. MNL-800-101 Printed Circuit Board Installation Mount the controller and complete wiring before installing the printed circuit board. 1. Verify power is OFF. 2. Follow the Static Precautions. 3. Remove enclosure cover. Caution: Do not pull or push on the circuit board components when installing or removing the printed circuit board. Doing so may result in damage to the circuit board assembly. 4. Remove and discard protected shipping tape from card slot. 5. Slide printed circuit board into place (Figure-4). 6. Replace enclosure cover. Communications Wiring Figure-4 Printed Circuit Board Installation. Caution: Communication wire pairs must be dedicated to S-LK and TAC MicroNet LonWorks network (LON) communications. They cannot be part of an active, bundled telephone trunk. Shielded cable is not required for S-LK or LON wiring. If the cable is installed in areas of high RFI/EMI, the cable must be in conduit. If shielded wire is used, the shield must be connected to earth ground at one end only by a 470K ohm 1/4 watt resistor. Shield must be continuous from one end of the trunk to the other. 6 Copyright 2006 TAC All Rights Reserved. F-26724-3

Communications wiring includes a connection between the controller and a TAC I/A Series MicroNet Sensor via the S-LK and a connection between the controller and the TAC MicroNet LonWorks Network (LON). An optional LON connection between the controller and one TAC I/A Series MicroNet Sensor is also possible. Sensor Link (S-LK) Wiring S-LK wiring powers and enables the MN-SX Sensor. The S-LK needs at least 24 gage (0.51mm), twisted pair, voice grade telephone wire. The capacitance between conductors cannot be more than 32 pf per foot (0.3m). If shielded cable is used, the capacitance between any one conductor and the others, connected to the shield, cannot be more than 60 pf per foot (0.3m). Maximum wire length is 200 ft. (61m). Note: Controller supports one TAC I/A Series MicroNet Sensor (MN-SX). S-LK wiring is polarity insensitive. If conduit is used between a TAC I/A Series Sensor and a controller, the TAC MicroNet LonWorks network and S-LK wiring can be in the same conduit. S-LK wiring (not LON wiring) can be in the same conduit with UI, AO, and DI wiring. TAC MicroNet LonWorks Network (LON) Wiring A Category 4, twisted-pair (two conductors) cable may be used for LON connection between controllers and between a controller and an MN-SX sensor. LON wiring is polarity insensitive. Caution: Do not mix with UI, AO, DI or DO types of wiring. If conduit is used between a TAC I/A Series Sensor and a controller, LON wiring and S-LK wiring can be in the same conduit. Checkout Stand-alone Controller Table-1 LED Indications MN 800 controllers use LonWorks Free Topology Transceiver (FTT-10) and support polarity insensitive bus (daisy-chain) and free (all combinations of star, tee, and loop) wiring topologies. A maximum of 62 nodes can be connected per segment. See TAC I/A Series MicroNet System Engineering Guide, F-26507 to design a TAC MicroNet LonWorks FTT-10 network, including recommended topologies and approved cable types. 1. Verify controlled devices are not powered or are in a controlled manual condition. 2. Apply power to MN 800 controller. 3. Check LED operation using Table-1. LED Operation Status Green Amber Red ON Flashes OFF OFF Flashes ON OFF OFF Blinking ON Normally ON indicating controller is powered and not actively transmitting data on the LON. Flashes OFF while actively transmitting data on the LON. Normally OFF unless actively receiving data from the LON. Flashes ON while actively receiving data from the LON. (Neuron - normal communications) Indicates the Neuron is operating properly allowing normal communications to and from the HVAC application. (Neuron - Off line) Neuron responds to network management messages only. In this state, communication to and from the HVAC application is not possible. To Correct, place the Neuron online by downloading an application using WP Tech or configure using a third party management tool. The service LED blinks at 0.5 Hz rate (1 second ON, 1 second OFF) to indicate that the Neuron is unconfigured (i.e. communications parameters not loaded). Corrective action: Configure the Neuron by downloading an application using the Work Place Technician s Tool or configure the neuron using a third party management tool. Indicates Neuron is not operating properly. Replace controller. F-26724-3 Copyright 2006 TAC All Rights Reserved. 7

Table-1 LED Indications LED Operation Status Heartbeat (Green LED) Blinking Wink Mode Diagnostic Blink Diagnostic Blink Diagnostic Blink OFF (Normal operation) The heartbeat LED blinks at 0.5 second ON, 0.5 second OFF to indicate controller is operating properly. Wink mode provides a visual means for identifying the controller using WP Tech or third party management tool. During wink, the heartbeat LED blinks as follows: With revision 1.x firmware: 2 seconds ON, 0.5 seconds OFF; cycles five times for a total of 12.5 seconds of wink time. With revision 2.x (or later) firmware: 3 seconds ON, 1 second OFF; cycles three times for total of 12 seconds wink time. (RAM/ROM Failure) The heartbeat LED repeats a pattern of 2 quick flashes followed by pause. To correct, turn power OFF then ON. Replace controller if necessary. (ROM Failure) The heartbeat LED repeats a pattern of three quick flashes followed by a pause. To correct, turn power OFF then ON. Replace controller if necessary. (RAM Failure) The heartbeat LED repeats a pattern of four quick flashes followed by a pause. To correct, turn power OFF then ON. Replace controller if necessary. Indicates controller is not operating properly. Check power. Replace controller if necessary. 4. Power down MN 800 controller if the programming will be done later, or program using TAC WorkPlace Tech. Figure-5 LED Indicators. Service Components within the MN 800 are not field repairable. The printed circuit board may be replaced, if necessary. (Follow the procedure described earlier in the Printed Circuit Board Installation section.) Consult your local TAC office for additional service details. Copyright 2006, TAC All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. F-26724-3 TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, IL 61132-2940 Distributed, manufactured, and sold by TAC. I/A SERIES trademarks are owned by Invensys Systems, Inc. and are used on this product under master license from Invensys. Invensys does not manufacture this product or provide any product warranty or support. For service, support, and warranty information, contact TAC at 1-888-444-1311. www.tac.com