SITE-LOG LPTH-1. Product Specifications. recognizes it and handles the configuration, downloading, graph viewing and more OVERVIEW

Similar documents
SITE-LOG LFVB. Product Specifications

Product Specifications

Specifications FEATURES

Its 16-bit ADC makes ilog data loggers well suited for science and laboratory applications where precise and accurate measurements are critical.

User s Manual Microedge Instruments Inc North Bluff Road. White Rock, BC, Canada, V4B 0A7. Toll Free:

User s Manual Microedge Instruments Inc.

USB-5100 Series Multi-Channel Data Loggers

Vaisala Veriteq VL 2000 Temperature Humidity Loggers

USB-5100 Series Multi-Channel Data Loggers

USB-500/600 Series Low-Cost Data Loggers and Accessories

CS200 DIGITAL MFC SOFTWARE 2.0

Specifications Minimum Typical Maximum Unit

Stand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

TITAN S8. Transportable Data Acquisition Device. Product Brochure EN

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

Phone: Fax: For calls outside the US please call:

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

High Voltage DC Meter

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

HIGH-VOLTAGE DC METER

Wide measurement range Temperature operating range is 10 to 65ºC (15 to 150ºF); RH range is 0 to 99% non-condensing.

SHIELD RADAR SPEED DISPLAY

Q.brixx station 101. Base Unit with Test Controller. Most important features:

Temperature/Rh Data logger. Users Manual. USB Datalogger IP 65 Water Proof

TITAN S8. Portable Data Acquisition Logger. Product User Guide

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14)

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Report Logger Manual Quick Start: V

USB to RS-422 / 485. US USB To Serial Operation Manual

Web-enabled DAQ System

WHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore

Operation Manual for Multifunctional Data Logger. HUATO Electronic Co., LTD.

SERIES E L I T - -J. Authorized distributor in Australia:

Product User Guide. QuadTemp and OctTemp. QuadTemp 4-Channel Thermocouple Based Temperature Data Logger

Decagon Devices, Inc. Version: February 29, :38:47

Humidity & Temperature Datalogger

DL6 Data Logger. Quick Start Guide Version 1.2. Delta-T Devices Ltd

A-307. Mobile Data Terminal. Android OS Platform Datasheet

MINI CLOCK TRAVEL PORTABLE FCC CE. SKU: MiniClockTravel USER MANUAL THANK YOU FOR PURCHASING THE MINI CLOCK TRAVEL

DS October MAXIM 1010 Controller

3-Axis G-Force Datalogger

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

USB Temperature and Humidity Data Logger Instruction Manual

SPEEDALERT 18 RADAR MESSAGING SIGN

Product Specification SpeedAlert 18 Radar Message Sign

8 or 16 Channel Universal Input Touch Screen Data Logger

A NEW DATA LOGGER Stand alone. Secure. Fast.

EL-USB-ACT AC and DC Millivolt Data Logger with Current Clamp Input

USB-TH LCD. USB Temperature & Humidity Logger With LCD CALIBRATION CERTIFICATES NOW AVAILABLE

Software for HOBO loggers

8 or 16 Channel Universal Input Touch Screen Data Logger

SCADAPack Smart RTU

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

X-Log Expert Data Logger

Squirrel Portable Data Loggers For research, quality assurance and production monitoring in industry, environmental sciences and in the laboratory

Online data sheet MEAC CEMS SOLUTIONS

GRYF. Measuring Instruments. measuring electrochemical and physical values. monitoring the environment. controlling technological processes

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

Andover ContinuumTM Infinet II

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

DD-600. A member of the Data Dolphin Family of Data Logging Systems. Data Dolphin Installation and Usage Manual

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

TC Compact Series Unitary Equipment Controller

Scannex rt.buffer Overview

Pen Drive USB Datalogger!

Data Sheet. RS Datascan data acquisition system

Seven Features You Didn t Expect from Your Bench DC Power Supply APPLICATION NOTE

Temperature/Humidity Data Logger with 2 Universal External Inputs

TALON Network Manager- 2 & 6 Express

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Notes on installing and using the OM-USB-5201 and OM-USB-5203 data logging devices

8 CHANNEL ANALOG DATA LOGGER

OPERATION MANUAL. USB Datalogger (Temp./RH/Thermocouple)

TFS 2100 Traveling Wave Fault Location System

2YL-T15-4M & 2YL-T16-4M Thermocouple Loggers. 2YL-M36-4M & 2YL-M37-4M Multi Terminal Input Loggers. 2YL-M61-4M & 2YL-M62-4M Lux Loggers

Agilent U2722A USB Modular Source Measure Unit. Data Sheet

Sefram SEFRAM DAS 20/DAS 40. Sefram

CONVERTER MC608 A/B/R/P/I. The Hybrid electronic converter for all applications DS300-1-USA

DATA SHEET Advanced Graphical Interface, AGI 100 series

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

Wireless Data Logger System

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

GP1 Data Logger. Quick Start Guide v2.0. Delta-T Devices Ltd

DS Type: MAXIM III Controller

and/or b. an optional internal Iridium satellite modem.

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

Software and Hardware Data-sheet

GTWIN 1.1 CONTROL TECHNOLOGY CORPORATION. GTWIN 2.8 Quick Start. MGT Panel & GTWIN Quick Start Guide

Model 475 Field Communicator. Connection. Environmental. Shipping Weight

AGATE TECHNOLOGY AT-2040

DIGITAL DIRECTIONAL INLINE OPTICAL POWER MONITOR/METER

MULTICHANNEL DATA RECORDERS

Q.brixx station 101. Base Unit with Test Controller. Most important features:

TC Modular Series for BACnet Networks

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Transcription:

SITE-LOG LPTH-1 407 15216 North Bluff Road White Rock, BC Canada V4B 0A7 Phone: 604.424.9092 Toll Free: 1.877.352.9158 Fax: 1.877.453.0658 Email: info@microedgeinstruments.com Web: Product Specifications OVERVIEW The SITE-LOG LPTH-1 is a 7-channel, battery powered, stand-alone thermistor data logger with storage up to 8 MB of data in non-volatile flash memory. It accepts nearly any kind of thermsitors that have the resistance value above 1K at 25 C. Its on-board temperature channel provides environment monitoring and temperature compensation. Its aluminum enclosure makes it excellent in the harshest industrial environment. Plug & Play USB port and versatile custom equation simplify communications and engineering unit conversion. 16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical. Simply plug the logger to computer's USB port, and the software automatically recognizes it and handles the configuration, downloading, graph viewing and more FEATURES High Data Resolution: The 16-bit analog-to-digital converter meets most high-resolution Large Memory Size: The 8-Mega-Byte Memory stores years of measurements. Programmable Input Ranges: One on-board thermistor channel monitors ambient temperature. Seven rangeprogrammable voltage external input channels cover wide measurement Multiple Communication Interfaces: The SITE-LOG data loggers can be accessed via USB, MODEM, or Ethernet connections with auto baud rate of up to 115 kbps. 1

Its on-board TTL serial port and USB interfaces meet most communication TTL Serial Port USB Port Excitation control turns on the power of external transmitter/transducer only when the logger is sampling. Alarm & Excitation Control 10-Year Battery Life: The internal lithium battery provides over 10 years of instantaneous logging operation when sampling at an interval of one minute. Fast Sampling Mode: The SITE-LOG data loggers can log data with the sampling interval as fast as 20 milliseconds, replacing data acquisition devices. Alarm and Excitation Output: The SITE-LOG data logger notifies the alarm condition over alarm terminal strips or communication lines. (USB, Serial Port, MODEM) Rugged Physical Design: The rugged aluminum enclosure and coated PCB makes the Site-Log data loggers perfect in the harshest industrial environment. Aluminum Case SITEVIEW SOFTWARE FEATURES SiteView is a PC based application works with SITE-LOG Series data loggers for downloading, configuration and data analyzing and plotting. Its user-friendly graphic interface plus powerful functionalities fit both novice and advanced users. The versatility of custom equation and custom-line equation handle complicated measurement Features: Support USB, Serial port and Ethernet connections for easy local and remote access Fast communication speed up to 115200 bps makes downloading fast 2

Real-time view and chart recording replaces chart recording device Custom equation and custom-line equation solves scientific and laboratory algorithm difficulties Zoom in/zoom out, annotation/label of graph functions provide detailed view of data Multiple file loading allows easy data comparison Dynamic statistics provides detailed information of current zoomed view Export to CSV, TXT, BMP, JPG, TIF, PNG, GIF file formats. 3

SPECIFICATIONS Product Identification Product Name Model Inputs Connections Site-Log LPTH-1 Pluggable terminal block for seven external channels, excitation controls and alarm outputs. Channels One on-board thermistor temperature (-40 C ~ 70 C, -40 F ~ 158 F). Seven external thermistor channels. Resolution 0.0018% Accuracy Internal thermistor channel: +/- 0.2 C(0 C ~ 70 C, 32 F ~ 158 F) External thermistor channels: +/- 0.2% FSR @ 25 C Alarms Channel Alarms Two editable alarm thresholds per channel. Alarm Outputs ALARM1 & A2/EXT terminal strips can be configured as alarm outputs. Alarm-On: MOSFET(N-Channel) switch on. Alarm-Off: MOSFET(N-Channel) switch off. Max Power: 200mA @ 24VDC. With purchase of SiteView software, the Site-Log can report alarm status to host PC via USB, Modem or Ethernet Device Server. Alarm-On Delay: Programmable 0-10 minutes delay with 1-minute increments. Alarm Indicator On-board LED lights in red when in alarm condition. On-board Memory 8 Mega bytes (4 Mega measurements). Data Retention Over 20 years. Sampling & Logging Sampling Interval 20 milliseconds to 12 hours user selectable [1] Logging Mode Stop recording or FIFO when memory is full. Logging Activation Programmable instant, start delay or field push-button activation. Communications Interface Baud Rate Battery Power Life Cycle USB(USB cable included). AUX(RJ11) for direct TTL level communications. With purchase of DeviceServer Kit, the Site-Log logger can be connected to Ethernet for remote access. Auto-detect baud rate from 2400 to 115200 bps on both USB and AUX ports. Built-in 3.6V Lithium Battery. 10 years based on 1 minute sampling interval. 4

Software SiteView [2] Configuration, downloading, plotting, real-time view, custom calibration and custom equation. Software Requirements Computer with 1.0 GHz or faster processor 256 MB Memory or higher 1.0 GB of available hard-drive space or higher Windows XP with SP2 or later, Vista, Window 7 At least one USB port or one COM port Physical Material Aluminum enclosure. PCB Treatment Conformal coating. Dimension 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches) Weight 200g. Mounting Probe/Wall-mount holes for hanging/mounting. Others LED Indicator Tri-Color LED: (can be disabled for power saving) Normal Sampling: green when sampling Alarm: red when sampling Low Battery: amber when sampling. Excitation Control A2/EXT terminal strip can be configured as excitation control output for driving the power of connected devices. Warm-up delay Interval settings: 10 to 240 seconds with 10- second increments. Operating Environment -40 ~ +70 C (-40 F ~ 158 F), 0~95%RH non-condensing. Clock Accuracy +/- 1 minute per month. Approvals CE, FCC [1]: Maximum enabled channel: 1 for 20ms interval, 2 for 30ms, 8 for 40ms or bigger interval. External power supply required if the sampling interval is less than five seconds. [2]: Sold separately. LOGGING CAPACITY TABLE Sampling Interval Enabled Channel Logging Sampling Interval Enabled Channel Logging 1 minute 1 8 years 1 second 1 48 days 1 minute 2 4 years 1 second 2 24 days 1 minute 8 1 year 1 second 8 6 days 10 seconds 1 485 days 100 ms 1 4 days 10 seconds 2 242 days 100 ms 2 2 days 10 seconds 8 60 days 100 ms 8 14.4 hours 5