Make the Most of Time

Similar documents
Iterative CT Reconstruction Using Curvelet-Based Regularization

Portability of TV-Regularized Reconstruction Parameters to Varying Data Sets

Total Variation Regularization Method for 3-D Rotational Coronary Angiography

Total Variation Regularization Method for 3D Rotational Coronary Angiography

Scaling Calibration in the ATRACT Algorithm

Spatial-temporal Total Variation Regularization (STTVR) for 4D-CT Reconstruction

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation

The Near Future in Cardiac CT Image Reconstruction

Depth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

Respiratory Motion Compensation for C-arm CT Liver Imaging

2D Vessel Segmentation Using Local Adaptive Contrast Enhancement

Respiratory Motion Estimation using a 3D Diaphragm Model

Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay

Reconstruction of CT Images from Sparse-View Polyenergetic Data Using Total Variation Minimization

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Automatic Removal of Externally Attached Fiducial Markers in Cone Beam C-arm CT

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

NIH Public Access Author Manuscript Med Phys. Author manuscript; available in PMC 2009 March 13.

Motion Compensation from Short-Scan Data in Cardiac CT

Reduction of Metal Artifacts in Computed Tomographies for the Planning and Simulation of Radiation Therapy

Towards full-body X-ray images

A new calibration-free beam hardening reduction method for industrial CT

DUE to beam polychromacity in CT and the energy dependence

Single Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction

Image Artefact Propagation in Motion Estimation and Reconstruction in Interventional Cardiac C-arm CT

Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

Estimating 3D Respiratory Motion from Orbiting Views

An Efficient Technique For Multi-Phase Model Based Iterative Reconstruction

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Automatic Intrinsic Cardiac and Respiratory Gating from Cone-Beam CT Scans of the Thorax Region

Coping with Real World Data: Artifact Reduction and Denoising for Motion-Compensated Cardiac C-arm CT

Separate CT-Reconstruction for Orientation and Position Adaptive Wavelet Denoising

Estimation of Missing Fan-Beam Projections using Frequency Consistency Conditions

Image Acquisition Systems

Blind Sparse Motion MRI with Linear Subpixel Interpolation

On the Characteristics of Helical 3-D X-ray Dark-field Imaging

Traditional Machine Learning for Limited Angle Tomography

Improvement and Evaluation of a Time-of-Flight-based Patient Positioning System

MOTION of a patient induces artifacts such as streaks

Accelerated C-arm Reconstruction by Out-of-Projection Prediction

ONE of the issues in radiology today is how to reduce the. Efficient 2D Filtering for Cone-beam VOI Reconstruction

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Non-Stationary CT Image Noise Spectrum Analysis

Sparse Principal Axes Statistical Deformation Models for Respiration Analysis and Classification

Image-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees

Intensity-Based 3D-Reconstruction of Non-Rigid Moving Stenosis From Many Angiographies erschienen in

Guided Image Super-Resolution: A New Technique for Photogeometric Super-Resolution in Hybrid 3-D Range Imaging

Constrained Reconstruction of Sparse Cardiac MR DTI Data

Top-level Design and Pilot Analysis of Low-end CT Scanners Based on Linear Scanning for Developing Countries

Digital Image Processing

Band-Pass Filter Design by Segmentation in Frequency Domain for Detection of Epithelial Cells in Endomicroscope Images

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

A Curvelet based Sinogram Correction Method for Metal Artifact Reduction

An approximate cone beam reconstruction algorithm for gantry-tilted CT

Optimal threshold selection for tomogram segmentation by reprojection of the reconstructed image

A Projection Access Scheme for Iterative Reconstruction Based on the Golden Section

View Aliasing Artifacts Reduction Method Based on 4D Cone-Beam CT Reconstruction with Joint Projection Data

Dynamic Cone Beam Reconstruction Using a New Level Set Formulation

Penalized-Likelihood Reconstruction for Sparse Data Acquisitions with Unregistered Prior Images and Compressed Sensing Penalties

Cardiac C-arm computed tomography

Scatter Correction Methods in Dimensional CT

A Simulation Study and Experimental Verification of Hand-Eye-Calibration using Monocular X-Ray

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

Suitability of a new alignment correction method for industrial CT

GPU-based Fast Cone Beam CT Reconstruction from Undersampled and Noisy Projection Data via Total Variation

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction

4D Computed Tomography Reconstruction from Few-Projection Data via Temporal Non-local Regularization

Erlangen-Nuremberg, Germany

1238 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 29, NO. 6, JUNE /$ IEEE

Image registration for motion estimation in cardiac CT

Fast iterative beam hardening correction based on frequency splitting in computed tomography

3D Guide Wire Navigation from Single Plane Fluoroscopic Images in Abdominal Catheterizations

Automatic Extraction of quasi-synchronous Views from Rotational Angiographic Sequence without ECG-Data

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

Background. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE /

Fiber Selection from Diffusion Tensor Data based on Boolean Operators

Generation of Triangle Meshes from Time-of-Flight Data for Surface Registration

Image-Based Device Tracking for the Co-registration of Angiography and Intravascular Ultrasound Images

Redundancy Encoding for Fast Dynamic MR Imaging using Structured Sparsity

Guided Noise Reduction with Streak Removal for High Speed Flat Detector CT Perfusion

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

Computer-Tomography II: Image reconstruction and applications

2005 IEEE Nuclear Science Symposium Conference Record M10-2

Automatic Extraction of 3D Dynamic Left Ventricle Model from 2D Rotational Angiocardiogram

Edge-Preserving Denoising for Segmentation in CT-Images

Deep Scatter Estimation (DSE): Feasibility of using a Deep Convolutional Neural Network for Real-Time X-Ray Scatter Prediction in Cone-Beam CT

Total Variation and Tomographic Imaging from Projections

Helical 4D CT pitch management for the Brilliance CT Big Bore in clinical practice

Acknowledgments and financial disclosure

Multidimensional Noise Reduction in C-arm Cone-beam CT via 2D-based Landweber Iteration and 3D-based Deep Neural Networks

Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition

ECG-Correlated Imaging of the Heart with Subsecond Multislice Spiral CT

Acknowledgments. Nesterov s Method for Accelerated Penalized-Likelihood Statistical Reconstruction for C-arm Cone-Beam CT.

7/31/ D Cone-Beam CT: Developments and Applications. Disclosure. Outline. I have received research funding from NIH and Varian Medical System.

GPU-Accelerated Time-of-Flight Super-Resolution for Image-Guided Surgery

Transcription:

Make the Most of Time Temporal Extension of the itv Algorithm for 4D Cardiac C-Arm CT Viktor Haase 1,5, Oliver Taubmann 2,3, Yixing Huang 2, Gregor Krings 4, Günter Lauritsch 5, Andreas Maier 2,3, Alfred Mertins 1 1 Institute for Signal Processing, University of Luebeck 2 Pattern Recognition Lab, Friedrich-Alexander-University Erlangen-Nuremberg 3 Graduate School in Advanced Optical Technologies (SAOT), Erlangen, Germany 4 University Medical Center Utrecht, Netherlands 5 Siemens Healthcare GmbH, Forchheim, Germany viktor.haase@student.uni-luebeck.de Abstract. Gated 4D cardiac imaging with C-arm CT scanners suffers from insufficient image quality due to strong angular undersampling. To deal with this problem, we suggest an iterative reconstruction method with spatial and temporal total variation regularization based on an established framework which controls the relative contributions of raw data error minimization and regularization. This new method is tested on a simulated heart phantom and on two clinical data sets. We show that the additional use of temporal regularization is advantageous compared to spatial regularization exclusively, with the relative root mean square error lowered from 11.75 % to 8.24 % in the phantom study. 1 Introduction Tomographic medical image generation by an angiographic C-arm system during an intervention would be efficient and helpful for planning, guiding and monitoring the therapeutic procedure. The research efforts of the last few years make it possible to reconstruct four-dimensional (4D) volumes using C-arm scanners [1, 2]. The projection data of one C-arm rotation documents various cardiac phases of multiple heart beats. ECG-gating, which divides the projection data into subsets for individual heart phases, is necessary to achieve sufficient temporal resolution. Each resulting subset contains too few projections and thereby allows only a highly artifact-impaired 3D image reconstruction. Therefore, 4D cardiac imaging typically suffers from bad image quality. To overcome these problems, motion estimation and compensation algorithms are suggested in the framework of filtered backprojection reconstruction techniques [1, 2]. Further improvements are achieved by incorporating spatiotemporal smoothing [3]. The problem of undersampled data is also addressed by iterative optimization algorithms in the context of compressed sensing. They employ sparsity-based regularization such as spatial total variation (TV) minimization. Mory et al. add a temporal TV regularizer for 4D cardiac imaging, T. Tolxdorff et al. (Hrsg.), Bildverarbeitung für die Medizin 2016, DOI 10.1007/978-3-662-49465-3_31, Springer-Verlag Berlin Heidelberg 2016

4D Cardiac C-Arm CT 171 achieving superior image results [4]. By applying temporal regularization, information of data from all heart phases can be leveraged during reconstruction of each individual phase. The improved total variation (itv) algorithm [5] is a sophisticated implementation of a spatial TV regularized reconstruction in which the trade-off of data fidelity and spatial regularization is controlled adaptively, in contrast to a fixed balance as used in, e. g., Mory s algorithm [4]. In this paper, we propose to extend the itv algorithm in order to incorporate temporal regularization. 2 Materials and methods The itv algorithm uses the simultaneous algebraic reconstruction technique (SART) and spatial TV minimization in an alternating manner [5]. In this section, we explain our adjustments to itv and specify the data used for evaluation. 2.1 Image reconstruction with spatio-temporal regularization For 4D imaging several cardiac phases t T = {0,...,N phases } are reconstructed. The measured projection data p(t) are assigned a heart phase t, with f n (t) denoting the corresponding reconstruction after iteration n {1,...,N}. An overview of our method is given in Fig. 1. We start from an empty volume f 0 (t) =0. To ensure data fidelity, a SART update step including a nonnegativity constraint is calculated in the beginning of each iteration resulting in the volume f SART n+1 (t). Two temporal regularization steps (orange boxes in Fig. 1) are introduced in addition to the spatial TV minimization of the original itv algorithm. At first, a no-motion constraint is enforced outside of a (manually chosen) volume of interest (VOI) containing the heart to improve convergence [4]. For this purpose, all voxels outside of the VOI are averaged over the temporal domain. Then, spatial TV minimization is applied to each volume [5]. Next, temporal TV regularization is incorporated into the algorithm, extending the idealized assumption of piecewise constant objects to the temporal domain. The 1D TV norm w. r. t. the temporal domain [4] is calculated. It is minimized for Data Fidelity Regularization f 0p SART VOI-based No-Motion Constraint Spatial TV Temporal TV f final if λ<λ lim f SART n+1 f n+1 =(1 λ)f SART n+1 + λf TV n+1 λ Calculation ɛ n Error Calculation f TV n+1 p ω Fig. 1. Sequence diagram of the extended itv algorithm. The new temporal regularization parts are highlighted in orange. When the stopping criterion λ<λ lim is reached, f final (t) is calculated using the dashed green path.

172 Haase et al. all voxels simultaneously by gradient descent iterations using backtracking line search and corner rounding to enable discrete differentiability. We denote the resulting volumes as f TV n+1(t). So as not to abandon raw data fidelity in spite of the desired regularization, f SART n+1 (t) andf TV n+1(t) are combined linearly at the end of each iteration [5] f n+1 (t, λ) =(1 λ)f SART n+1 (t)+λf TV n+1(t) (1) The variable λ [0, 1] controls the impact of data fidelity and regularization. We design it to be independent of the heart phase, thereby avoiding different degrees of smoothing applied to the individual phases. It is related to the parameter ω ]0, 1[ which specifies the permitted loss of data consistency by regularization for the current iteration n + 1 regarding the previous n-th iteration ɛ n+1 =(1 ω)(ɛ SART n+1 ɛ n )+ɛ n (2) where ɛ now denotes the total data consistency error for all phases ɛ = t T( R(t)f(t, λ) p(t) 2 2) (3) R(t) is the system matrix that describes the projection of f(t) to the corresponding raw data p(t). By solving the quadratic Eq. (2), the ideal λ is determined [5]. If this would result in λ<0orλ>1, λ is set back to its defined limits. Typically, λ starts at 1 and decreases over the course of optimization [5]. Instead of a fixed maximum number of iterations N, weprefertostopthereconstruction after λ has dropped below a specified limit λ lim. Hence, the desired degree of smoothness in the resulting images can be specified directly. Higher values of λ lim lead to a more comic-like appearance due to stronger TV minimization. With a high ω, theλ values decrease more slowly, resulting in more iterations to be performed. Once the stopping criterion is reached, the full regularization is applied one last time (visualized as the green path in Fig. 1) so that high-frequency artifacts are reduced in the final volume f final (t). 2.2 Experimental setup The reconstruction method is evaluated on a simulated heart phantom data set [6]. The projections are generated with a polychromatic X-ray spectrum [7]. The acquisition protocol is identical to that of the clinical data sets described below, with a simulated heart rate of 120 bpm and no respiratory motion. The ground truth is a static phantom showing the end-diastolic heart phase. It is reconstructed from a fully sampled scan with our method (Fig. 2 (a)). As evaluation measures, the relative root mean square error (RMSE) and the universal image quality index (UQI) [8] are calculated over the VOI. Instead of a global computation, the UQI is averaged over 10 small blocks of size (16 mm) 3 to increase sensitivity.

4D Cardiac C-Arm CT 173 To test our proposed algorithm on real data, two clinical patient data sets are acquired using an Artis zee biplane system (Siemens Healthcare GmbH, Forchheim, Germany). The detector dimension is 960 x 960 pixels. The isotropic pixel resolution is 0.312 mm/pixel (0.21 mm/pixel in isocenter). One C-arm rotation of 5 s duration is performed, capturing 133 projection images with an angular increment of 1.5 per frame. The heart is paced through external stimulation to 228 bpm for the first and 140 bpm for the second data set, resulting in 19 and 11 heartbeats per rotation, respectively. The following reconstruction parameters are used: For all data sets, eight cardiac phases are reconstructed. In every SART update step, eight full SART subiterations are executed with a relaxation parameter of 0.8. Every SART subset consists of one complete projection image. For both TV minimization steps, 10 gradient descent iterations are performed. The chosen values for the convergence controlling parameters ω =0.8 andλ lim =0.35 are determined empirically. To bring out the effects of our proposed method more clearly, all reconstructions are repeated with spatial TV minimization only, excluding the temporal regularization steps. 3 Results The results for the heart phantom data set are shown in Fig. 2. For the sake of comparison, a SART reconstruction without any regularization is performed (a) (b) (c) (d) Fig. 2. Reconstructed images of the heart phantom data set. From left to right: Ground truth (a), SART reconstruction (b), iterative reconstruction with spatial TV regularization (c) and our proposed method (d). All images display the end-diastolic heart phase. The top row shows an axial plane, a coronal plane is depicted underneath. The grayscale is set to [ 1000, 2480] HU.

174 Haase et al. (Fig. 2(b)). The image is dominated by noise and streaks due to undersampling and the process is stopped after 10 iterations as no further improvement is identified after this point. To a certain degree, these artifacts can be reduced by applying spatial TV regularization as seen in Fig. 2(c). The image quality achieved with our proposed spatio-temporal regularization in Fig. 2(d) is a pronounced improvement; all structures seen in the ground truth (Fig. 2(a)) are now represented more clearly, even though they are somewhat blurred. For the heart itself, this may in part be caused by residual motion inside the gating window. The visual advantages of the incorporated temporal regularization compared to the application of spatial regularization only are reflected by the quantitative evaluation. The relative RMSE over the VOI is decreased from 11.75 % to 8.24 % and the UQI over the VOI is increased from 0.76 to 0.98. Fig. 3 shows that the temporal regularization helps to accelerate the convergence of the reconstruction as λ reaches the lower limit of λ lim more quickly. Instead of 63 iterations, only 22 iterations are necessary to achieve convergence. The spatio-temporal regularization also works well on our clinical data. A clear improvement can be seen for the first data set in Fig. 4(b) compared to 4(a) as well as for the second in Fig. 4(d) compared to 4(c). In general, the reconstruction of the second data set struggles with more artifacts due to the lower number of recorded heart beats. It took 18 iterations for the first and 19 iterations for the second data set to converge with our proposed method. 4 Discussion While the chosen parameters appear to be suitable for the examined data sets, it is yet to be verified how well they generalize over a larger number of cases. As an extension of the proposed method, it may be helpful to introduce the possibility to control the influence of the temporal TV minimization separately from the spatial one. For further research, it may be worthwhile to implement a different optimization algorithm which does not optimize the data fidelity and regularization terms alternately but combines them into one cost function to minimize them jointly as proposed in [9]. We suggest an extended version of the itv algorithm using spatio-temporal regularization to overcome the challenges posed by angular undersampling due to ECG gating. The results of our experiments in a phantom study and on two clinical data sets demonstrate that especially the use of temporal regularization is highly beneficial for use in 4D cardiac C-arm CT. Fig. 3. Development of λ during the 1.0 Full Regularization reconstruction of the phantom data set. Spatial Regularization The spatial regularization (dashed blue λ 0.75 curve) is compared to the proposed spatiotemporal regularization (orange curve). 0.5 The threshold λ lim used in our stopping λ lim 0.25 criterion is marked with the green line. 0 10 20 30 40 50 60 70 Iteration

4D Cardiac C-Arm CT 175 Fig. 4. Reconstructed images of the clinical patient data sets. From left to right: the first data set reconstructed with spatial TV regularization (a) and with our proposed method (b), the second data set reconstructed with spatial TV regularization (c) and with our proposed method (d). All images show a coronal view. The grayscale is set to [ 1000, 2480] HU. (a) (b) (c) (d) Disclaimer. The concepts and information presented in this paper are based on research and are not commercially available. References 1. Müller K, Maier A, Schwemmer C, et al. Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT. Phys Med Biol. 2014;59(12):3121. 2. Wielandts JY, De Buck S, Michielsen K, et al. Multi-phase rotational angiography of the left ventricle to assist ablations: feasibility and accuracy of novel imaging. Eur Heart J - Cardiovasc Imaging. 2015. 3. Taubmann O, Lauritsch G, Maier A, et al. Estimate, compensate, iterate: joint motion estimation and compensation in 4-D cardiac C-arm computed tomography. Proc MICCAI. 2015; p. 579 86. 4. Mory C, Auvray V, Zhang B, et al. Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization. Med Phys. 2014;41(2):021903. 5. Ritschl L, Bergner F, Fleischmann C, et al. Improved total variation-based CT image reconstruction applied to clinical data. Phys Med Biol. 2011;56(6):1545. 6. Segars W, Sturgeon G, Mendonca S, et al. 4D XCAT phantom for multimodality imaging research. Med Phys. 2010;37(9):4902 15. 7. Maier A, Hofmann HG, Berger M, et al. CONRAD - A software framework for cone-beam imaging in radiology. Med Phys. 2013;40(11):111914. 8. Wang Z, Bovik AC. A universal image quality index. IEEE Signal Process Lett. 2002;9(3):81 4. 9. Lauzier PT, Tang J, Chen GH. Prior image constrained compressed sensing: implementation and performance evaluation. Med Phys. 2012;39(1):66 80.