DATASHEET FUJITSU SPARC ENTERPRISE T5440 SERVER

Similar documents
Data Sheet Fujitsu M10-4 Server

Datasheet Fujitsu ETERNUS DX90 S2 Disk Storage System

Data Sheet Fujitsu M10-1 Server

Data Sheet Fujitsu M10-4S Server

Datasheet Fujitsu ETERNUS DX90 S2 Disk Storage System

Data Sheet Fujitsu M10-4 Server

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Data Sheet FUJITSU Storage ETERNUS DX200F All-Flash-Array

Datasheet Fujitsu ETERNUS DX60 S2 Disk Storage System

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System

Data Sheet Fujitsu ETERNUS DX500 S3 Disk Storage System

Data Sheet FUJITSU ETERNUS DX60 S3 Disk Storage System

Datasheet Fujitsu ETERNUS DX8700 S2 Disk Storage System

Data Sheet Fujitsu ETERNUS DX80 S2 Disk Storage System

Data Sheet Fujitsu ETERNUS DX400 S2 Series Disk Storage Systems

Datasheet Fujitsu ETERNUS LT20 S2

Fujitsu ETERNUS LT40 S2

Datasheet Fujitsu ETERNUS LT60 S2

Flexible and scalable system that delivers high performance and high availability for mission-critical enterprise applications

Data Sheet FUJITSU Storage ETERNUS DX60 S3 Disk Storage System

DATASHEET FUJITSU ETERNUS LT20 TAPE LIBRARY

Data Sheet FUJITSU JX60 S2 DAS Subsystem

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX600 S3 Disk System

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Data Sheet FUJITSU Storage ETERNUS JX60 Subsystem

Data Sheet FUJITSU Storage ETERNUS JX40 S2 Subsystem

Datasheet Fujitsu ETERNUS LT60 S2

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

SUN SERVER X2-4 SYSTEM

Data Sheet FUJITSU Storage ETERNUS DX500 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX60 S4 Disk Storage System

Data Sheet FUJITSU Storage ETERNUS LT20 S2 Tape System

SUN SPARC ENTERPRISE M5000 SERVER

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

Data Sheet FUJITSU Storage ETERNUS LT40 S2 Tape System

Data Sheet FUJITSU Storage ETERNUS AF650 S2 All-Flash Array

Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node

Cisco MCS 7816-H3. Supported Cisco Applications. Key Features and Benefits

SUN BLADE 6000 CHASSIS

Data Sheet FUJITSU Storage ETERNUS LT60 S2 Tape System

Oracle Database Appliance X6-2S / X6-2M

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

Fujitsu SPARC M12-1 Server

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

Data Sheet FUJITSU Storage ETERNUS AF250 S2 All-Flash Array

Oracle Database Appliance X6-2L

Data Sheet Fujitsu PRIMERGY TX1310 M1 Server

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

Data Sheet Fujitsu PRIMERGY TX100 S3 Server

SUN SERVER X2-8 SYSTEM

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

Fujitsu SPARC M12-2S Server

Datasheet Fujitsu ETERNUS LT270 S2

Oracle Database Appliance X6-2S / X6-2M

FUJITSU ETERNUS DX8000 SERIES DISK STORAGE SYSTEMS FOR LARGE ENTERPRISES

Data Sheet FUJITSU Server PRIMERGY SX960 S1 Storage Blade Disk

Data Sheet FUJITSU Storage ETERNUS DX8700 S3 Disk System

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Data Sheet FUJITSU Storage ETERNUS AF250 All-Flash Array

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Cisco UCS C200 M2 High-Density Rack-Mount Server

Cisco MCS 7825-H3. Supported Cisco Applications

Acer AT110 F2 Specifications

ORACLE DATABASE APPLIANCE X3 2

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

Fujitsu SPARC M12-2 Server

Data Sheet FUJITSU Storage ETERNUS CS800 S7

Data Sheet FUJITSU Storage ETERNUS DX200 S4 Disk System

Datasheet FUJITSU ETERNUS LT270 S2

Data Sheet FUJITSU Storage ETERNUS DX200 S3 Disk System

NEC Express5800/R120e-1M System Configuration Guide

SUN SERVER X3-2 SYSTEM

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server

Data Sheet Fujitsu PRIMERGY TX100 S2 Server

Data Sheet FUJITSU Storage ETERNUS DX200F

Data Sheet FUJITSU Storage ETERNUS CS800 S6

Data Sheet Fujitsu LTO Desktop Drive

Data Sheet FUJITSU Server PRIMERGY BX900 S2 Blade Server

Data Sheet Fujitsu PRIMERGY MX130 S2 Server

SPARC T5-8 SERVER. Product Overview

Altos T310 F3 Specifications

Data Sheet FUJITSU Storage ETERNUS LT60 S2 Tape System

Data Sheet FUJITSU Storage ETERNUS DX100 S4 Disk System

NEC Express5800/R120d-2M Configuration Guide

Data Sheet Fujitsu PRIMERGY BX900 S2 Blade Server

Data Sheet Fujitsu PRIMERGY TX1330 M2 Server

Datasheet Fujitsu SPARC Enterprise M8000 server

Cisco MCS 7816-H3 Unified Communications Manager Appliance

Data Sheet FUJITSU Storage ETERNUS DX500 S4 Disk System

Data Sheet FUJITSU Storage ETERNUS DX500 S4 Disk System

Data Sheet Fujitsu PRIMERGY TX100 S2 Server

Oracle Database Appliance X7-2S / X7-2M

2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 1 of 6

Intel IP Network Server NSI2U

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

Acer AC100 Server Specifications

NEC EXPRESS5800/R320a-E4 Configuration Guide

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Transcription:

DATASHEET FUJITSU SPARC ENTERPRISE T5440 SERVER SPARC Enterprise Server are proven UNIX based computers based on the latest and most performant and reliable SPARC processor architecture and running the worldwide number 1 UNIX operating environment Solaris 10. The new Fujitsu SPARC Enterprise server T5440 like T5140 and T5240 using the new UltraSPARC T2 Plus chip-multithreading (CMT) processor - is setting new standards in the market for network centric computing, energy efficiency and compute density, providing the ideal platform particularly for larger web and application tier services and for online transaction processing and technical workloads. This new model extends the existing CMT platform to 4-socket multiprocessor systems. Built-in, no-cost virtualization capabilities in the server also enable customers to easily maximize system utilization, helping to lower the cost of delivering new IT services. SPARC Enterprise T5440 The model T5440 is the first model in the T5xxx line incorporating up to 4 UltraSPARC T2 Plus processors with 1.2 GHz, 1.4 GHz or 1.6 GHz (each with 8 cores enabled). Each of the cores can issue up to 8 threads simultaneously, in total up to 256 threads. The T5440 model also offers in a compact 4 RU form factor - up to 512 GB memory (64 DIMM slots), 4 hot-plug disk bays and 8 PCIe slots, two 10 GbE plus two 1 GbE onboard network interfaces. The Solaris 10 Operating System and the logical domain feature are preinstalled and provide a highly flexible, efficient and secure application environment. RAS features include redundant power supplies, fans, core offlining, extended ECC protection and the Integrated Lights Out Management (ILOM) tool to enable the server to be integrated and managed within industry-standard management frameworks. Page 1 of 7

FEATURES AND BENEFITS MAIN FEATURES BENEFITS 1, 2 or 4 UltraSPARC T2 Plus processors (8 cores each) with 1.2 GHz, 1.4 GHz or 1.6 GHz Massive compute density and throughput through four-socket server design processor field-upgrade to 2 or 4 processors Industry-leading space and power consumption efficient, rackoptimized 4RU design No-compromise eco efficiency: 4 sockets for maximized performance and throughput at minimized space and power levels only 1.6 watts per thread with 1.2GHz Solaris 10 Operating System and LDom support preinstalled Providing new standards for performance, availability and security, saving significant time and money when deploying, operating and managing IT infrastructures Increased consolidation/virtualization capabilities with Solaris containers and logical domains Flexible basic configurations starting with 1 processor and upgradeable to up to 4 processors Right-sized configurations - easy to configure and order - depending on customers request. Processor field-upgrade guarantees investment protection Built-in no-cost multithreading (256 threads) and virtualization (128 LDom s) capabilities Highest level of utilization by deploying many applications on a single server improved flexibility, reduced administration efforts Advanced reliability, serviceability and security features, including electronic prognostics monitoring Decreased installation time and downtime, increased agility and reduced management overhead Page 2 of 7

Technical characteristics Up to 4 UltraSPARC T2 Plus processors with CoolThreads technology offers up to thirty-two multithreaded cores. Typical processor power consumption of 105 watt (1.2 GHz) or 132 watt (1.4 GHz), delivering up to 256 simultaneous threads per System. Using Logical Domains (LDoms) up to 128 isolated OS instances possible. Up to 64 FBDIMM Slots Up to 8 PCI-express controllers. Up to 2 external PCI expansion Boxes with each 2 boats and in each boat 6 PCI slots for PCI-express possible, each boat occupies 1 server internal PCI-e slot for a Link card. Total amount of 28 PCI slots. Up to 2 XAUI cards for 10Gbit Ethernet, occupies 1 PCI-e slot and 1 onboard 1 Gbit Eth. Port each. Redundant components: hard disk drives 2.5, fans (standard), power supply units and power feeds Hot-plug able components: hard disk drives, power supply units and fans Monitoring of system operating status in real time on system management console. 19-inch rack system (4HU) Integrated Lights Out Manager, ILOM, with: 1 Serial interface 1 10/100 Mb Ethernet interface CLI, LAN console connection through LAN direct to ILOM LAN port. Secure Ethernet interface (secure shell CLI) Host side interface/admin utility Host side monitoring (disks, fans, power, temp, PSU, Field Replaceable Unit ID, hot plug devices) Host control (power, reset) Enhanced events logging (ILOM events, host events, hot-plug devices) Logging events to ILOM (including nvram and syslog) Logging host console stream output Out-of-box functionality (Server management capability even when the OS is not available) Hardware environmental monitoring/management Ultra SPARC T2 Plus Processor Functions 8 core version SPARC V9 compliant Core features: 8 threads per core 8 KB primary data cache per core 16 KB primary instruction cache per core 2 instruction pipelines per core 1 Floating Point Unit per core 1 Security coprocessor per core 1 cryptographic accelerator unit per core (IPsec Enable only with special SW) Two memory channels: Memory BW 25 GB/sec Read and 13 GB/sec Write each channel four cache coherence channels for processor to processor connection integrated onto chip 4 MB On-chip level 2 cache shared by all cores, 8 banks Two memory controllers Up to 64 threads per Processor In Processor Integrated Options: Up to 8 cores, 8 threads per core PCI-E x8 interface with relaxed DMA ordering Technology: 65 nm technology 1.2 GHz, 1.4 GHz and 1.6 GHz frequency Power consumption 105 watt (1.2 GHz) 0r 132 watt (1.4 GHz) Page 3 of 7

TECHNICAL DETAILS Processor CPUs / cores and threads Level-1 Cache per core, (I/D) Level-2 Cache shared by all cores Ultra SPARC T2 (SPARC V9 compliant) up to 4 CPU per Server / 8 core 64 threads per CPU 16KB Instruction Cache / 8KB Data Cache 4MB / CPU Clock Speed 1.2 GHz 1.4 GHz 1.6 GHz SPECint_rate2006 (with 8 cores) SPECfp_rate2006 (with 8 cores) 258 estimated 197 estimated 301 230 360 270 Main memory configuration min. capacity max. capacity Expansion unit up to 64 Fully Buffered DIMM slots, ECC / Extended ECC(only 4 GByte FBDIMM s) protected 8 GB (4 x 2 GB DIMMs) 512 GB (64 x 8 GB DIMMs) 4GB, 8GB and 16GB units (bundled in pieces confirmed via Configuration Guide) I/O ports (Standard) LAN / XAUI 4 x 1 Gbit Ethernet (10baseT / 100baseTX / 1000base TX ; RJ45) On Board / OR 2 x 1 Gbit Ethernet (10baseT / 100baseTX / 1000base TX ; RJ45) plus 2 x 10Gbit via XAUI (occupy PCI Slots) V.24 (RS232C) 1 serial port (DB9 RS232C) USB 2 x 2 ports Ver. 2.0. (2 on Front Side and 2 on Rear Side, only for Keyboard and Mouse) console port 1 x serial port (RJ45 on ILOM) 1 x Ethernet port (10baseT / 100baseTX RJ45 on ILOM) SAS bus (for int. disk drives) 2 buses per 1 Control-Chip per Server (SAS, Serial attached SCSI) PCI slots PCI-express 8 slots low profile with PCI-e 8 lanes (see also LAN / XAUI) External PCI expansion Boxes up to 2 Expansion Box PCI slots Electively in each Box 1 or 2 boats with 6 PCI-e slots each (one boat occupies a system internal PCI-express slot) PCI Slots in external I/O-Box Up to 24 PCI Slots in total Up to 28 Useable PCI-controller LVD U320 Dual SCSI U320 SCSI, 16bit, 2 channels Fibre Channel SAS 2connector, 8port/8line 1 Gb Gigabit Ethernet 4 or 8 Gbit/s, 2 channels or 1 channel 1Gb Gigabit Ethernet 1000 base-sx, 2 channels 10Gb Gigabit Ethernet 10baseT/100baseTX/1000 base-tx, 2 channels or 4 channels Graphics 10 Gbit XAUI with 1 GIBIC module, or PCI-e 10 Gbit with up to 2 GIBIC modules Page 4 of 7

Mass storage (hard disks) 2,5 SAS 10krpm / 15krpm Max. Data rate 300MB/s Min. capacity 1 x 73 GB 1) Expansion unit 73 GB 1) / 146 GB 1) / 300 GB 1) Max capacity 1200 GB 1) (4 x 300GB 1) ) Mass storage (Solid State Disk) 32 GB 1) 2,5 SATA SSD Mass storage (DVD) DVD+/-RW Software Operating system Solaris 10 starting with Update 6 1) 1 MB = 10 6 Byte, 1 GB = 10 9 Byte Page 5 of 7

Installations specification SPARC Enterprise Server T5440 4HU rack version up to 4-CPU socket, up to 32 cores, up to 256 threads per Server I/O-Box for T5440 4HU rack version Up to 2 boats, each 6 PCI-e slots Width 445 mm 440 mm Depth 633 mm 730 mm (1000 mm with cable management unit) Height 176 mm 175 mm Maintenance area Maintenance area is specified in rack description Weight 40 kg 36.8 kg Rated voltage 100-120 VAC / 200-240 VAC 100-240 VAC Main connections max. 4 x IEC320-C14 2 x IEC320-C14 Frequency 50/60Hz 50/60Hz Wattage Power consumption, max. 2,700 Watt 600 Watt Heat generation 9,213 BTU/hr (9,720 kj/hr) Operating temperature / from 5 to 35 º C / 0 900 m, from 5 to 34 º C / 0 1,200 m, Operating altitude from 5 to 33 º C / 0 1,500 m, from 5 to 32 º C / 0 1,800 m, from 5 to 31 º C / 0 2,100 m, from 5 to 30 º C / 0 2,400 m, from 5 up to 35º C / 0 3,000 m from 5 to 29 º C / 0 2,700 m, from 5 to 28 º C / 0 3,000 m Relative humidity 10 % - 90 % relative humanity, non condensing 20 % - 80 % relative humanity, non condensing Non-operating Environment -40 C to 65 C 93% relative humidity, non condensing 98% RH 38 C, relative humidity, non condensing Declared Acoustic Operating/Idling Acoustic Noise 8.9 B (LwAd,1B=10dB) 80 db (LpAm, bystander positions) Operating/Idling Acoustic Noise 6.7 B (LwAd,1B=10dB) 59 db (LpAm, bystander positions) Category Relevant Standards T5440 Relevant Standards I/O-Box Product Safety CFR21 part1040, CNS14336, IEC825-1, IEC825-2, EN60950-1, IEC60950-1 CB Scheme with all country deviations, UL/CSA-60950-1 RFI / EMC * 1) 47CFR15B ClassA, AS/NZ3548 ClassA, CNS13438 ClassA, EN55022 ClassA, EN61000-3-2, EN61000-3-3, ICES-003 Class A, KSC5858 ClassA, VCCI ClassA, CSA/UL-60950-1, EN60950-1, IEC825-1, IEC60950-1 and CB Scheme with all country deviations EN55022/CISPR22 ClassA, FCC CFR47 part15 ClassA, EN61000-3-2, EN61000-3-3 Immunity EN55024, IEC61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8 & -4-11 EN55024, EN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8 & - 4/11 Telecommunications EN300-386 Regulatory Markings BSMI, CE, C-tick, FCC, GOST-R, ICES-003, MIC, UL/cUL, UL/S-mark, VCCI CE, UL, BSMI, FCC, VCCI, ICES, C-tick, Gost-R, MIC, WEEE, China-RoHS, CCC, S-mark, CSA/UL *1) This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Page 6 of 7

FUJITSU PLATFORM SOLUTIONS MORE INFORMATION COPYRIGHT In addition to FUJITSU SPARC ENTERPRISE/SERVER, FUJITSU provides a range of platform solutions. They combine reliable FUJITSU products with the best in services, know-how and worldwide partnerships. Dynamic Infrastructures With the FUJITSU Dynamic Infrastructures approach, FUJITSU offers a full portfolio of IT products, solutions and services, ranging from clients to datacenter solutions, Managed Infrastructure and Infrastructure-as-a-Service. How much you benefit from FUJITSU technologies and services depends on the level of cooperation you choose. This takes IT flexibility and efficiency to the next level. Computing Products www.fujitsu.com/global/services/computing/ Software www.fujitsu.com/software/ Learn more about FUJITSU SPARC ENTERPRISE/SERVER, please contact your FUJITSU sales representative or FUJITSU Business partner, or visit our website. http://www.fujitsu.com/sparcenterprise FUJITSU GREEN POLICY INNOVATION FUJITSU Green Policy Innovation is our worldwide project for reducing burdens on the environment. Using our global know-how, we aim to resolve issues of environmental energy efficiency through IT. Please find further information at [http://www.fujitsu.com/ global/about/environment/] Copyright 2009 FUJITSU Technology Solutions FUJITSU, the FUJITSU logo and FUJITSU brand names are trademarks or registered trademarks of FUJITSU Limited in Japan and other Countries. Other company, product and service names may be trademarks or registered trademarks of their respective owners. DISCLAIMER Technical data are subject to modification and delivery subject to availability. Any liability that the data and illustrations are complete, actual or correct is excluded. Designations may be trademarks and/or copyrights of the respective manufacturer, the use of which by third parties for their own purposes may infringe the rights of such owner. CONTACT FUJITSU Technology Solutions Website: www.fujitsu.com/sparc ENTERPRISE 2010-11-11 [WW] [EN] Page 7 of 7