AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

Similar documents
AEW36.2. Pulse Adapter. Siemeca AMR

AEW Pulse Adapter. Building Technologies

Network node WTT56.. A6V _en--_c Building Technologies

AB Axis Industries. Use

Network nodes with gateway

Mobile Data Collector

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

RMZ790. Operator Unit. Building Technologies. Synco 700

M-bus RF gateway. Meters and Energy Cost Allocation WTT563-0C0000

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Interface converter for VAV compact controllers

Digital input modules

TXM1.8RB. TX-I/O Blinds module

Rotary actuators for ball valves

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

M-Bus Central Unit. Use

Room unit with PPS2 interface

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

The network node works extremely well in more complex building environments (e.g. where fire doors/glass walls are installed).

Air damper actuators

SEH62.1. Digital Time Switch

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Fast running actuators for air dampers

Room unit with PPS2 interface

ERF910. RF Repeater. Synco living

Rotary version, three-position control

RF adapter plugs, dimming

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Electromotive actuators for combi valves

LON Module for Variable Speed Drive

Heating Circuit Controller

BACnet/IP Web Interface

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Super universal modules

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

WFZ16 WFZ166. Add-on radio module. Add-on modules for external water meters prepared for wireless transmission

Handheld Tool for VAV compact and modular controllers

Electromotoric actuators

Radiator Lockshield Valves ADN.. AEN..

Extension module for lighting control

Semi flush-mounted room temperature controllers with LCD

RNN5-STD NETWORK NODE FOR AMR SYTEMS

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Room Temperature Controller

Immersion Temperature Sensors

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Communication module to connect M-bus devices to POL6xx.xxx controllers.

VAV modular controller

Power supply module, bus connection module

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Air Damper Actuators Modbus RTU

MC 11 EB-2 Power supply cabinet with external bus, AC version

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Accessories and options

Heating Circuit Controller

Electromotoric actuators

Electromotoric actuator

Rotary actuator for ball valves KNX / PL-Link

M-Bus Central Unit OZW10

Air Damper Actuators Modbus RTU

MID approval no. DE-08-MI004-PTB004 Date of release

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Electrical Actuators

24-hour room temperature controller

ABB 520BID01 Binary Input datasheet

Electrical Actuators

VAV compact controller

multipulse, multilog Installation and operating manual All that counts. EnergyMetering

SONOMETER TM 500 Ultrasonic compact energy meter

HOBO State Data Logger (UX90-001x) Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Status display unit with P-bus connection

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Solenvis SL80 Pulse to M-Bus Converters

Transponder card holder

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

HOBO State Data Logger (UX90-001x) Manual

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Non-communicating room controllers

Operating instructions. Standstill monitor A / / 2011

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

Island bus expansion module

Operating Manual -ENGLISH- Page 1 KWG-ISO

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Room unit with PPS2 interface

PADPULS2 M-BUS Pulse Input Modules

Operating and mounting instructions

Transcription:

2 873 Siemeca AMR Pulse Adapter AEW36.2 The AEW36.2 pulse adapter acquires and handles the pulses from 1 or 2 consumption meters with pulse output and transmits the data to a Siemeca AMR network. For setting the parameters, the pulse adapter is equipped with 2 interfaces, 1 wired interface and 1 optical interface. Use The pulse adapter is a component of the Siemeca AMR system. It is for installations where consumption meters with pulse output are used the data of which shall be collected by the Siemeca AMR system. Such devices can be meters for hot water, cold water, gas, electricity, etc. Functions Acquisition of the pulses delivered by the connected consumption meters Monitoring the connecting cable in the case of metering devices with NAMUR circuit Handling of pulses and storage of consumption data and set day values Wireless transmission of data 6 times a day to the WT..16.. network nodes of the Siemeca AMR system CE1N2873en Building Technologies

Type summary Standard version AEW36.2: Connection of 2 meters to the connecting cable by means of the cable connectors supplied with the unit. Labeling in German. Country-specific version AEW36.2/DK: Connection of 2 meters to the pulse adapter s terminal block. Labeling in Danish. Ordering When ordering, please give type reference: AEW36.2 Equipment combinations When installing, the pulse adapter must be programmed with the data set delivered with the parameter setting software for the respective meter. If meters not contained in the meter data base shall be connected, a new data set must be requested. With the correct data set installed, the following types of meters can be connected: Water meters with pulse output Heat meters with pulse output Gas meters with pulse output Steam meters with pulse output Electricity meters with S0 interface (note: an additional S0 converter is required, e.g. z.b. IC-2, available by Nordwestdeutsche Zählerrevision Ing. Aug. Knemeyer GmbH & Co. KG, Heideweg 33, 49196 Bad Laer) Technical design The pulse adapter handles pulses in accordance with the following specification: Pulse source limit values (if parameters are appropriately set) blue / red to AEW Electronic outputs (Open Collector, Open Drain) residual voltage when switched max. frequency min. pulse width < 0.7 V < 17 Hz 30 ms Mechanical switches (Reed contact, relays) bounce time max. frequency min. pulse width < 1 ms < 2 Hz 260 ms R2 R1 Mechanical switches with NAMUR circuits resistance R1 resistance R2 2.2 kohm 5.6 kohm The inputs are protected against overvoltages. Open collector outputs must be connected with the correct polarities: Channel 1: + blue, ground Channel 2: + red, ground

Power supply Data transmission The pulse adapter is powered by a lithium battery which has a service life of 12 + 1 years. It cannot be changed in the field. Data are transmitted to the Siemeca AMR network 6 times a day. Display steps short press of button short press of button short press of button Statistik Statistik Statistik Statistik Statistik Statistik Statistik Statistik long press of button The LCD of the pulse adapter has 4 display levels: Meter 1 ( Zähler 1 ) Meter 2( Zähler 2 ) Meter 1 statistics Meter 2 statistics The display level currently used is indicated by a little arrow ( ) below the name of the level. A short press of the button produces a switching action within the same display, a long press produces a change from one display level to the next. The first 2 display levels show current, meter-related values. The other 2 display levels show 13 end-of-the-month values of the relevant meter. Display Display levels 1 and 2 (meters 1 and 2) are identical. Statistik Statistik Display level meter 1 or meter 2 In the event of fault (severe, constant fault), this is the standard display. It alternates with the display showing the date the fault occurred. In the event of a temporary fault, the respective error code is displayed. This display alternates with a blank display. In normal operation, the standard display shows the consumption. kwh C GJ/h The display test switches all display segments on and off. Consumption on the set day. This display alternates with the display showing the set day (notation: dd.mm). If, during the pulse adapter s operation, some other set day is programmed, the new set day appears here. 3/8

Identification number of the connected meter (to be entered when setting the meter s parameters). Data set number (describes the type of meter). h Number of operating hours. Primary address When pressing the button for more than 2 seconds in this step, the transmission of 8 installation telegrams will be started. IrDA primary address. Software version. Installation telegrams: Sending installation telegrams; the 2 digits indicate the remaining telegrams for the 2 channels of the pulse adapter. Display levels 3 and 4 (meter 1 statistics and meter 2 statistics) are identical. They show the consumption values and the date of that consumption over the past 13 months. Statistik Statistik Display level meter 1 statistics or meter 2 statistics Alternate display of consumption value and last day of the previous month (notation: dd.mm.yy). Alternate display of consumption value and last day of the previous month (notation: dd.mm.yy). Displays continue for the last 13 months. Error code Error code Description of fault 2 Number of operating hours 6 Pulse acquisition channel 1 open-circuit 7 Pulse acquisition channel 1 short-circuit 8 Pulse acquisition channel 2 open-circuit 9 Pulse acquisition channel 2 short-circuit B Number of communication via IrDA exceeded C Number of communication via M-bus exceeded F Device not initialized

Engineering notes To ensure correct data transmission, the pulse adapter should be installed in locations where radio transmission is not impaired. In case of doubt, the transmission conditions are to be tested with the PC radio module (refer to Data Sheet CE1N2876). Length of connecting cable For immunity reasons, the total length of the connecting cable may not exceed 10 m. Mounting notes Electrostatic Sensitive Devices f Mounting All modules integrated in the meters are electrostatically endangered components. The freely accessible contacts (cable end, plug connector) are only partially protected against interference. Skilled personnel should avoid wearing polyester clothing and shoes with plastic soles as this type of clothing promotes electrostatic charging. Electrostatic charging of skilled personnel must be deflected when handling open components e.g. by touching an earthed piping system. When installing the meter, insert 1 wire of the pulse adapter s connecting cable and 1 wire of the meter s connecting cable into one of the cable connectors supplied with the unit. Then, squeeze the connector with a pair of pliers. This connection cannot be separated and offers degree of protection IP54. Only for AEW36.2/DK: With the housing cover open, insert the meter connecting cables with the O-ring from the rear of the unit into the cable strain relief and connect the cables to the terminal block. Then, close the housing. Commissioning notes Wired parameter settings The pulse adapter is to be programmed during installation. Enter the following data for each channel: Type of pulse source (Reed switch, Reed switch with NAMUR, Open Collector, etc.) per input Type of medium (gas, water, etc.) per input Physical variable (kwh, m 3, etc.) per input Pulse valency per input Set day per input (1 set day per year) Meter readings when commissioning the pulse adapter, per input Meter number (identification number) per input The parameters can be set wire-bound or via the integrated optical interface (IrDA): For wired parameterization, a laptop (Windows 98 or higher), the ACT20 parameter setting software, and the WFZ.MBM programming adapter are required. 5/8

Parameter settings via IrDA Triggering installation telegrams Parameterization via the integrated optical interface (IrDA) is carried out by means of a PDA. For the pulse adapter to log on to the Siemeca AMR network, installation telegrams must be triggered on the pulse adapter after parameterization: On the first display level, press the button briefly a few times until you reach the M-bus display: Then, keep the button depressed for more than 2 seconds. The installation telegrams will be sent: The display shows the number of the remaining installation telegrams for each channel. Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Dispose of empty batteries in designated collection points. Technical data Operating voltage DC 3 V Life expectancy 12 +1 years Nominal frequency 868.3 MHz Transmitting power < 5 mw Transmission frequency 6 times / 24 hours Degree of protection IP 54 to EN 60 529 Safety class III to EN 60 950 Perm. ambient temperature Transport and storage Operation 25 +60 C 0 55 C Product standard EN 60950-1 Safety of information technology equipment Electromagnetic compatibility (Applications) For use in residential, commerce, light-industrial and industrial environments EU conformity (CE) CE1T2873xx *) Weight 0.3 kg Product environmental declaration (contains CE1E5383 *) data on RoHS compliance, materials compo sition, packaging, environmental benefit, disposal) *) The documents can be downloaded from http://siemens.com/bt/download.

39,5 79 Connection diagrams INP 1 INP2 U1 Connection of any type of meters with pulse output blue red P1 P2 U1 AEW36.2 pulse adapter P1, P2 Meter with pulse output AC 230 V INP 1 INP2 U1 blue red Connection of electricity meters with S0 interface OUT INP N1 OUT INP N2 S0 P1 S0 P2 U1 AEW36.2 pulse adapter P1, P2 Electricity meters with pulse output N1, N2 WHZ.SO pulse converter Dimensions 3,5 79 90 95,5 27,3 Dimensions in mm Connecting cable length is 350 mm. 7/8

Overview of Siemeca AMR documentation Type of unit Siemeca AMR system Type reference Document Data Sheet CE1N2870 Engineering Manual CE1J2870 Heat cost allocator WHE46 Data Sheet CE1N2877 Wireless pulse adapter AEW36.2 Data Sheet CE1N2873 Heat meters WFM26, WFQ26. Data Sheets CE1N5333, CE1N5347, CE1N5338, CE1N5348 Water meters WFC26, WFH26, WFC36, WFH36, WMC36, Data Sheets CE1N5341, CE1N5343 Data Sheets CE1N5328 Data Sheets CE1N5329 WMH36 Network node WTT16 WTX16 Data Sheet CE1N2874 Network node with Gateway Software WTX16.IP WTX16.GSM WTX16.MOD ACS, ACT Data Sheet CE1N2878 Data Sheet CE1N2875 PC radio module WTZ.RM Data Sheet CE1N2876 M-bus central unit OZW10 Data Sheet CE1N5362 Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2007 Delivery and technical specifications subject to change