SSD Architecture Considerations for a Spectrum of Enterprise Applications. Alan Fitzgerald, VP and CTO SMART Modular Technologies

Similar documents
HP VMA-series Memory Arrays

NVMe Takes It All, SCSI Has To Fall. Brave New Storage World. Lugano April Alexander Ruebensaal

Achieve Optimal Network Throughput on the Cisco UCS S3260 Storage Server

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Exactly as much as you need.

Sugon TC6600 blade server

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu.

Cisco HyperFlex HX220c M4 Node

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Flash Controller Solutions in Programmable Technology

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

Assessing and Comparing HP Parallel SCSI and HP Small Form Factor Enterprise Hard Disk Drives in Server Environments

Model: DS-2250J. Venus T5 mini 2.5 SATA RAID. User Manual.

EonStor DS 3000 Series

SAS Technical Update Connectivity Roadmap and MultiLink SAS Initiative Jay Neer Molex Corporation Marty Czekalski Seagate Technology LLC

THE SUMMARY. CLUSTER SERIES - pg. 3. ULTRA SERIES - pg. 5. EXTREME SERIES - pg. 9

2.5-Inch SATA SSD PSSDS27Txxx6

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Solid State Performance Comparisons: SSD Cache Performance

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades

HP visoko-performantna OLTP rješenja

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System

Virtual Storage Tier and Beyond

Isilon Scale Out NAS. Morten Petersen, Senior Systems Engineer, Isilon Division

Easily Recreate the Qtier SSD Tier

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

DDN. DDN Updates. Data DirectNeworks Japan, Inc Shuichi Ihara. DDN Storage 2017 DDN Storage

Cisco UCS M5 Blade and Rack Servers

ZD-XL SQL Accelerator 1.6

QuickSpecs. PCIe Solid State Drives for HP Workstations

The PowerEdge M830 blade server

NEC Express5800 Servers System Configuration Guide

The Benefits of Solid State in Enterprise Storage Systems. David Dale, NetApp

EonStor DS 3000 Series

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

Cisco UCS C240 M4 I/O Characterization

Selecting Server Hardware for FlashGrid Deployment

FAQs HP Z Turbo Drive Quad Pro

How to Speed up Database Applications with a Purpose-Built SSD Storage Solution

Cisco UCS S3260 System Storage Management

HP SAS benchmark performance tests

Veritas NetBackup on Cisco UCS S3260 Storage Server

NVMe: The Protocol for Future SSDs

Oracle <Insert Picture Here>

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment.

4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering

Cisco UCS S3260 System Storage Management

HPE Scalable Storage with Intel Enterprise Edition for Lustre*

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510

Cisco UCS C24 M3 Server

End-to-End Adaptive Packet Aggregation for High-Throughput I/O Bus Network Using Ethernet

Interface Trends for the Enterprise I/O Highway

PRESENTATION TITLE GOES HERE

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

The Oracle Database Appliance I/O and Performance Architecture

Storage Update and Storage Best Practices for Microsoft Server Applications. Dennis Martin President, Demartek January 2009 Copyright 2009 Demartek

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

EMC VMAX 400K SPC-2 Proven Performance. Silverton Consulting, Inc. StorInt Briefing

SSD Applications in the Enterprise Area

Flash In the Data Center

Flash Memory. SATA SSD vs. PCIe NVMe SSD. White Paper F-WP003

Increasing Performance of Existing Oracle RAC up to 10X

FlashGrid Software Enables Converged and Hyper-Converged Appliances for Oracle* RAC

The Why and How of Developing All-Flash Storage Server

CompTIA Storage+ Powered by SNIA

Cisco UCS C200 M2 High-Density Rack-Mount Server

Dual-Slot M.2 Drive to SATA Adapter for 2.5" Drive Bay - RAID

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

Enterprise Ceph: Everyway, your way! Amit Dell Kyle Red Hat Red Hat Summit June 2016

IBM Emulex 16Gb Fibre Channel HBA Evaluation

Deep Dive -PCIe3 RAID SAS Adapters Optimized for SSD s

Oracle Server X6-2L. Product Overview

Three Paths to Better Business Decisions

SanDisk Enterprise Storage Solutions

Computer Architecture 计算机体系结构. Lecture 6. Data Storage and I/O 第六讲 数据存储和输入输出. Chao Li, PhD. 李超博士

Storage Systems Market Analysis Dec 04

Chapter 6. Storage and Other I/O Topics

Next Generation Computing Architectures for Cloud Scale Applications

Linux Device Drivers: Case Study of a Storage Controller. Manolis Marazakis FORTH-ICS (CARV)

IBM 2-watt 15.8 GB 2.5-inch Solid State Drives provide new technology in performance for storage in BladeCenter

Cisco HyperFlex HX220c Edge M5

Deploy a High-Performance Database Solution: Cisco UCS B420 M4 Blade Server with Fusion iomemory PX600 Using Oracle Database 12c

Exam Questions C

Hitachi Virtual Storage Platform Family

EMC SYMMETRIX VMAX 40K SYSTEM

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM

EMC ISILON S-SERIES. Specifications. EMC Isilon S200. EMC Isilon S210 ARCHITECTURE

Accelerating Workload Performance with Cisco 16Gb Fibre Channel Deployments

Dual-Bay 2.5 to 3.5 SATA Hard Drive Adapter Enclosure with RAID

Cisco UCS C220 M5 Rack Server Disk I/O Characterization

Dual-Slot M.2 Drive to SATA Adapter for 2.5" Drive Bay - RAID

Cisco UCS B440 M1High-Performance Blade Server

Removing the I/O Bottleneck in Enterprise Storage

HUAWEI Tecal X6000 High-Density Server

(Detailed Terms, Technical Specifications, and Bidding Format) This section describes the main objective to be achieved through this procurement.

UNIVERSITY OF MASSACHUSETTS Dept. of Electrical & Computer Engineering. Computer Architecture ECE 568

High Performance SSD & Benefit for Server Application

HP0-S15. Planning and Designing ProLiant Solutions for the Enterprise. Download Full Version :

Transcription:

SSD Architecture Considerations for a Spectrum of Enterprise Applications Alan Fitzgerald, VP and CTO SMART Modular Technologies

Introduction Today s SSD delivers form-fit-function compatible solid-state memory replacements for hard disks By offering an HDD plug-in replacement, the SSD serves a massive existing infrastructure Physical size and mounting Host interface connectivity Feature set and software compatibility

Distributed Controllers Drive New SSD Topologies The opportunity today for SSDs in network RAID storage is to replace enterprise HDDs with high IOPS SSDs Advancements in distributed flash controller topologies permit the optimization of flash packaging to improve performance, power, and storage density beyond the standard SSDs in HDD form factors

HDD Storage System Alternative This presentation illustrates a solid state storage system alternative to HDD-based RAID storage systems memory packaging offers better efficiency when not used in the HDD form factor Advanced fabric connected flash controller technology brings advantages of provisioning, reliability, performance, availability, and low cost FRU management

HDD RAID Architecture A network storage system comprises High speed network I/O to the host / network Large cache memory to increase IOPS by consolidating small block transfers Redundant HDD controllers, disk drives, and power supplies to ensure high system availability Hot swappable media where the HDD is the FRU (Field Replaceable Unit)

Typical RAID Implementation w/ 3.5-Inch HDD

Solid State Storage Blade System appropriate, high speed host front-end Fibre Channel, SAS, Infiniband, PCIe Multiple arrays of flash DIMMs The DIMM becomes the FRU interconnected through a highspeed flash fabric Multiple hubs on the flash fabric provide connectivity between the DIMMS and the host front-end System specific application configuration Provisioning Availability Performance

Solid State Storage Blade Hub Dual-Port Host Network Interface Host Interface Storage Application Fabric Fabric Hub Hub Fabric Hub

Solid State Storage Blade

DIMM Packaging Simplifies FRU and User Experience This SSD topology takes advantage of high volume and low manufacturing costs of DIMM packaging Configurable for redundancy (RAID) and hot swapping, the DIMM is field replaceable without system power down The user (not the SSD manufacturer) determines overall capacity through the population and density of DIMMs

Fabric High Speed Serial Single or Multiple Lane Typical serial similar to SATA and PCIe Simplified Fabric Complexity Relative to PCIe, SATA, SAS, IP Low Latency Optimize IOPS and Reduce Bottlenecks Packets Optimized for Logical Pages Enforce Media Efficiencies

Four DIMM Array 1 TeraByte Ctrl 256 GB Memory Array Fabric Fabric Hub Fabric Ctrl Ctrl 256 GB Memory Array 256 GB Memory Array Ctrl 256 GB Memory Array

DIMM Characteristics 256 GByte Capacity 2 Watts 25 K / 20 K / ~20 K IOPS 4 KByte random Read / Write / 2R:1W 300 MB/s / 200 MB/s 128 KByte sequential Read / Write 78 IOPS per GByte 2R:1W 20 K / 256 128 GBytes per Watt 256 GBytes / 2

DIMM Storage Element

Distributed Controllers Using High Speed Fabric Communication over the Fabric High speed single or multi-lane Optimized command set for low power and low latency Each Controller Manages Arrays of Appears as a group of logical pages to the fabric Translation to host logical blocks performed at the Application Layer through a Logical Unit Manager

Controller Basic Controller Responsibilities Interface I/O supporting all of the external connectivity, features and protocols Logical block to physical memory translation mapping and management channel management with error detection, error correction, wear leveling, defect management, and the flash physical interface

DIMM Storage FRU Controller Memory Arrays 32 GBytes NAND Fabric Fabric Interface Bus Control 8 or More Arrays 32 GBytes NAND Manager L2P Memory Payload Controller Cache Memory

JBOD Storage Application Logical Unit Management Individual Disks with no Redundancy RAID 0 Striped Disks with no Redundancy RAID 1 Mirrored Disks with Redundancy RAID 5 3 or More Disks with Redundancy

Storage Front-End Host I/O Application Layer I/O Host Network Host Interface: Infiniband PCIe FC Dual Port SAS Dual Port Storage Application - Logical Unit Management JBOD RAID 0 RAID 1 RAID 5 Fabric I/O Fabric

Application Configured Solid State Storage Blade Hub RAID 0 Dual-Port Host Network Interface Host Interface Storage Application Fabric Fabric Hub Hub Fabric JBOD RAID 1 RAID 5 Hub

JBOD on a Single DIM 256 GByte Capacity ~20 K IOPS Random 2R:1W 4 KB >200 MBps Sequential (Fabric Saturated) High Availability No Redundancy 128 GBytes per Watt 256 GBytes / 2 W 78 IOPS per GB 20 K / 256 GBytes 10,000 IOPS per Watt 20 K / 2 W

RAID 0 Example

RAID 0 Across Five DIMS 1.25 TeraByte Capacity ~100 K IOPS Random 2R:1W 4 KB >800 MBps Sequential High Availability No Redundancy 125 GBytes per Watt 1,250 GB / 10 W 80 IOPS per GB 100 K / 1,250 GB 10,000 IOPS per Watt 100 K / 10 W

RAID 1 Example

RAID 1 Across Two DIMS 256 GByte Capacity ~33 K IOPS Random 2R:1W 4 KB >400 / 200 MBps R/W Sequential High Availability One DIMM per DIMM Pair Redundancy 64 GBytes per Watt 256 GB / 4 W 129 IOPS per GByte 33 K / 256 GB 8,250 IOPS per Watt 33 K / 4 W

RAID 5 Example

RAID 5 Across Eight DIMS 1.75 TeraByte Capacity ~140 K IOPS Random 2R:1W 4 KB >800 MBps Sequential High Availability One DIMM Redundancy 109 GBytes per Watt 1,750 GB / 16 W 80 IOPS per GB 140 K / 1,750 GB 8,750 IOPS per Watt 140 K / 16 W

Storage Application Performance Variations IOPS MBps GB / W IOPS / G IOPS / W JBOD 20K 300R / 200W 128 78 10,000 RAID 0 100K >800 125 80 10,000 RAID 1 33K 400R / 200W 64 129 8,250 RAID 5 140K >800 109 80 8,750

Wrap Up There are many storage applications with a corresponding number of SSD solutions ranging from 1.8 HDD replacements to PCIe plug-in cards. This discussion represents one perspective among the many solid state storage solutions. SMART is currently developing Fabric Attached flash controllers. Our first products based on this technology will be available in Q1 of 2010.

Thank You!