URGENT Field Safety Notice Philips HeartStart MRx Monitor/Defibrillator

Similar documents
This document contains important information for the continued safe and proper use of your equipment

This document contains important information for the continued safe and proper use of your equipment

URGENT - Medical Device Correction IntelliVue MX40 Missing Warnings in IFU

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

URGENT FIELD SAFETY NOTICE

Philips HeartStart XL Defibrillator Manual

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

Defibrillation made simple

SpO 2 Upgrade Instructions

Product Specifications

Complete the Confirmation Sheet, and return it to Physio-Control using the information on the form.

Defibtech DDU-100 Semi-Automatic External Defibrillator

CARELINK NETWORK UPDATES SUMMARY OF ENHANCEMENTS May 2017

URGENT FIELD SAFETY NOTICE Reserve battery and new instructions for users of the PAD 300/PAD 300P (Public Access Defibrillator)

Philips HeartStart MRx Owners Manual

Service Manual. M4735A HeartStart XL Defibrillator/Monitor

LIFEPAK 15 Test Calibration Procedure ( TCP)

Urgent Medical Device Correction LIFEPAK 1000 Defibrillator

HeartStart XL+ Service Library. Service Manual. HeartStart XL Edition 3

Cardiostart. Biphasic Defibrillator Monitor

LIFEPAK CR PLUS/EXPRESS Defibrillator TABLE OF CONTENTS

Making lifesaving faster, easier, better for professional responders. Philips HeartStart FR3 Defibrillator supplies and accessories

Original Manufacturer

HeartStart Data Messenger User guide

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

HAZARD NOTICE By arrangement with the Scottish Executive Health Department

Important Medical Device Advisory NM Implantable Pulse Generator Inaccurate Elective Replacement Indicator

R Series Configuration Manual

Power. Document Part Number: This guide explains how the computer uses power. December 2005

Important Medical Device Advisory NM Implantable Pulse Generator Inaccurate Elective Replacement Indicator

LEGAL NOTICE INVITATION TO SUBMIT BIDS

IMPORTANT SAFETY INSTRUCTIONS

SPECIFICATION FOR THE SUPPLY OF A BATTERY MONITORING SYSTEM

DEFRIBILLATORS PARAMEDIC CU-ER1

ipad SP2 Automatic External Defibrillator

PowerMust Office Uninterruptible Power System

Always in touch. IntelliVue Telemetry System with Smart-hopping technology, surveillance of ambulatory cardiac patients

Power. Document Part Number: This guide explains how the computer uses power. March 2006

Universal Docking Station with 2.4GHz Wireless Speakers for iphone/ipod

M Series AHA/ERC Guidelines 2005 Software Configuration Overview

Defibtech DDU-100 Semi-Automatic External Defibrillator User Manual

Defibtech Automated External Defibrillator Lifeline/ReviveR DDU-100 Lifeline/ReviveR AUTO DDU-120

OWNER'S GUIDE BT 390

Making lifesaving faster, easier, better for professional responders

NO COMPROMISE IN AN EMERGENCY CASE

An AED with a view. Never fear. Rescue ready.

Bluetooth Speaker Instruction Manual

Vital Signs Trending. with the HeartStart MRx and XL+ PUBLISH. Application Note. Introduction

Delta 1600 User Manual

Installation of Firmware Updates on H-2221 GOES Transmitters

Copyright 2018 by Boston Scientific, Inc.. Permission granted to INCOSE to publish and use. #hwgsec

The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance.

Defibtech DDU-100 Series Automated External Defibrillator DDU-100 DDU-120

Hardware and Components: Philips Monitors in Critical Care

5.6" Multi-function Monitor

1.0.0 May A. Polycom RealPresence Group Series with Zoom Connector for Polycom

Defibtech DDU-2300 Semi-Automatic External Defibrillator

BTH-808 WIRELESS BLUETOOTH HEADSET USER S MANUAL

RTT98 VINTAGE TURNTABLE

Defibtech DDU-2400 and DDU-2450 Automated External Defibrillator

17 th Edition (BS 7671:2008) incorporating Amendment No 1

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

EPS Power Supply

Polycom RealPresence Group Series

Installing and Configuring Rialto Analytic Appliances

Introducing Lifeline PRO

Connex Vital Signs Monitor 1.7 to 2.2 Upgrades

Philips GoGear audio video player SA065104K SA065104S SA065108K SA065108S. Quick start guide

User Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction

Allworx 24x Service and Troubleshooting Guide

User s Guide for the Polycom RealPresence Group Series

User Guide. μvrc Robotic Control System. μvrc Robotic Control System. Part No. V

Product codes with prefix (all variants): 8001, 8002, 8003, 8004, and ATTENTION: Clinical Personnel, Risk Managers, Biomedical Personnel

FIELD CORRECTIVE ACTION NOTICE

OWNER S MANUAL. Lighting Audio System. Read the supplied b o ok let S afet y Bro chure b efore us i n g t h e u n i t Yamaha Corporation

Olive_QS_SL.book Page 1 Wednesday, September 18, :41 PM Quick Start

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

Defibtech DDU-2300 Semi-Automatic External Defibrillator

1.0 October A. Polycom RealPresence Group Series with BlueJeans Relay

Defibtech Lifeline AED Fully Automatic Manual

USER S MANUAL. CCTV TESTER Model:TM035

Mini Pulse Electronic Stimulator Model: PM-120

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

the next generation life energy

ml/h ml/h ml/h ml/h or off or off )or off

Contents -1- Please read the following safety warnings and precautions before using your device.

Operating instructions Addressing unit AC1144

PUBLISH. HeartStart MRx Service Library. Implementation Guide. Data Transmission. HeartStart MRx to HeartStart Telemedicine

1 - Spedo 2100TRO Operators Manual Spedo UK Limited

ARGUS PRO LifeCare 2. Patient monitor, 12-channel ECG, defibrillator and pacemaker in a compact format F A C T U R M A N U A N D I N E D E U R O I G N

Model: VA/230W UPS Backup System

Operating Instructions

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

CU-SP1 INTELLIGENT PUBLIC ACCESS DEFIBRILLATOR. Medical and Surgical Requisites Pty Ltd

Lenovo ideapad 300. User Guide. ideapad ISK ideapad ISK ideapad ISK


User s manual PS1200-T.

ENVIRONMENTAL PROTECTION

HBAC-30. Owner s Manual. Battery powered Guitar Amp

Transcription:

Philips Healthcare - 1/5 - FSN86100160A Dear Customer, Philips has identified issues that could impact the safety and/or performance of certain MRx monitor/defibrillators. These issues are further detailed in the attached Field Safety Notice. This Field Safety Notice is intended to inform you about: what the issue is and under what conditions it can occur the actions that should be taken by the customer/user in order to prevent risks for patients the corrective action planned by Philips to address the issue This document contains important information for the continued safe and proper use of your equipment Please review the following information with all members of your staff who need to be aware of the contents of this communication. It is important to understand the implications of this communication. Please retain a copy with the equipment Instructions for Use. Please see the following pages, which provide information on how to identify affected devices and instructions on actions to be taken. Follow the ACTION TO BE TAKEN BY CUSTOMER / USER section of the notice. Philips is initiating a software upgrade that will be provided to customers free of charge. A Philips Healthcare representative will contact you to arrange for installation of the software upgrade. We appreciate your patience as we work to schedule your upgrade. This voluntary correction has been reported to the appropriate regulatory agencies. Philips sincerely apologizes for any inconvenience this may cause you. If you have questions regarding this notification or need any further information or support, please contact your local Philips representative or the UK Philips Customer Care Service Centre on 0870 532 9741. Sincerely, John Pardo Director QA/RA, Emergency Care and Resuscitation

Philips Healthcare - 2/5 - FSN86100160A AFFECTED PRODUCTS Product: s Units Affected: MRx units with a serial number within the following ranges: Model M3535A: US00100100 to US00576623 Model M3536A: US00100902 to US00576650 Model M3536J: US00209838 to US00332675 Model M3536M: US00500002 to US00553553 Model M3536MC: US00500001 to US00500087 Model M3536M2: US00554176, US00554177, US00554178 Model M3536M4: US00500003 to US00574869 Model M3536M5: US00500001 to US00562935 Model M3536M6: US00554358 to US00576619 PROBLEM DESCRIPTION Issue 1: The MRx can be susceptible to interference from electrical fast transients (EFTs) when connected to AC or DC power, operating with a LAN cable, or operating near a source of EFT interference, which could cause therapy to be delayed or delivered inadvertently. Issue 2: If a user performs either of the following two atypical clinical workflows, the MRx can exhibit unexpected behavior. These workflows do not correspond to instructions in the MRx Instructions for Use (IFU) and are not expected to be performed by trained clinicians. In addition, these device behaviors have only been observed during internal testing, and have not been reported during clinical use. The workflows and associated device behaviors are as follows: Workflow A: When using external paddles for defibrillation, the MRx can deliver a shock when only one of the two shock buttons are depressed if the user performs the following sequence: 1. MRx in use with external paddles and turned on in Manual Defib mode 2. User presses and holds a single button on the external paddle Apex and turns the Therapy Knob to any other Clinical Mode (Monitor, Pacer, AED) 3. User releases the button being held on the external paddles 4. User turns the MRx back to any Manual Defib setting and presses charge 5. User inadvertently presses the button on the other external paddle Sternum. The MRx will deliver a shock with this single button press. The ability to shock with a single button press will continue until the device is shut off. Note: Paddles Apex and Sternum can be interchanged to reproduce the issue.

Philips Healthcare - 3/5 - FSN86100160A PROBLEM DESCRIPTION (continued) Workflow B: When using the Periodic Clinical Data Transmission (PCDT) option on the MRx, the MRx can reboot if the user performs the following sequence: 1. In Monitor mode with PCDT turned on and transmitting, the user switches from Monitor Mode to Manual Defib mode. 2. While the display is transitioning from Monitor mode to Manual Defib mode, the user presses the Sync button. 3. The MRx reboots, restarting in 6 to 8 seconds. The MRx could stop demand mode pacing due to an ECG leads-off condition when electrode-to-skin contact impedance values are outside design ranges for detection. Note: Philips has previously improved the MRx s ability to maintain ECG monitoring in the presence of high skin contact impedance. However, these improvements are not available on devices with Revision B.06.XX software. HAZARD INVOLVED Issue 1: If EFT interference occurs: The MRx shock function could disarm, causing a delay in defibrillation therapy. The MRx pacing function could pause, causing a delay in pacing therapy The MRx could deliver an inadvertent discharge when using switched internal paddles, causing an unintended shock to patient or users. Note: If the MRx disarms unexpectedly due to this issue, the user can press the charge button to continue operation. Likewise, if the MRx pauses pacing due to this issue, the user can resume pacing to continue operation. Issue 2: Workflow A B Hazard if specific workflow is followed When using external paddles for defibrillation, the MRx can deliver an inadvertent shock when only one of the two shock buttons are depressed, potentially causing an unintended shock to patient or users. When using the PCDT option on the MRx, the MRx can reboot. If a patient is in need of emergent cardioversion, the reboot could potentially lead to a delay in therapy. If electrode-to-skin contact impedance values are outside the ranges for detection during demand mode pacing, pacing could be interrupted, potentially leading to a delay in therapy.

Philips Healthcare - 4/5 - FSN86100160A HOW TO IDENTIFY AFFECTED PRODUCTS ACTION TO BE TAKEN BY CUSTOMER / USER Philips HeartStart MRx Monitors/Defibrillators identified above are affected by one or more of these issues. The model and serial numbers of your HeartStart MRx Monitor/Defibrillator are printed on the primary label on the back of the MRx in battery bay B. You can continue to use your MRx prior to receiving the software upgrade, provided that you follow the guidance provided below. Issue 1: If interference were to occur: Users could experience the symptoms described below, and can take the listed actions to resume operation. (Note: these symptoms can occur for other clinical reasons unrelated to electrical interference.) Symptom When charged, the MRx disarms unexpectedly, and displays a Defib Disarmed message and audio tone. When pacing, the MRx displays a Pacing Stopped message, displays a Pads Off or Pads Cable Off message, and enunciates an alarm. Action to resume operation To recharge the device, press the Charge button. Check that the pads are applied correctly to the patient. Check cable connections. Press the Resume Pacing soft key to continue pacing. There is a potential for inadvertent discharge when using switched internal paddles. To mitigate the risk associated with this, users should ensure that, prior to charging the MRx, the internal paddles are correctly applied to the patient and the user is not touching the patient or paddle contacts. Issue 2: Ensure that users are aware that the two workflows described in the Problem Description section of this Field Safety Notice can lead to unexpected device behavior, and therefore should not be performed.

Philips Healthcare - 5/5 - FSN86100160A ACTION TO BE TAKEN BY CUSTOMER / USER (continued) The MRx will display the Pacing Stopped. Leads Off message when pacing has stopped due to detection of a leads-off condition or an ECG cable disconnection. (Note: this message can display for clinical reasons unrelated to the issue described in this Field Safety Notice.) If this message appears during demand mode pacing, users can choose either of the following options to resume pacing, if desired: Troubleshoot the leads-off condition as described in the MRx Instructions for Use: Check that the monitoring electrodes are applied properly to the patient. Check cable connections. Press the Resume Pacing soft key to continue pacing. Change the pacing mode to fixed using the following steps: 1. With the therapy knob in the Pacer position, press the Menu Select button to activate the Main Menu. 2. Use the Navigation buttons to select Pacer Mode and press the Menu Select button to confirm. 3. Use the Navigation buttons to select Fixed, and press the Menu Select button to confirm. ACTIONS PLANNED BY PHILIPS FURTHER INFORMATION AND SUPPORT Philips is initiating a correction to affected devices. A software upgrade will be provided free of charge for all units affected by one or more of these issues. A Philips Healthcare representative will contact customers with affected devices to arrange for installation of the upgrade. If you need any further information or support concerning this issue, please contact your local Philips representative or the UK Philips Customer Care Service Centre on 0870 532 9741.