Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

Similar documents
Preface. is the registered trademark of ODVA (Open DeviceNet Vender. Association). *1 Excluding the GP-3200 series.

GP-70 Series. User Manual. I/O Unit

Package Contents. GP Options (Made by Digital)

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

WARNINGS. *1 This mark is applicable only in Taiwan.

Preface. The CC-Link unit is compatible with up to CC-Link Ver. 2.0.

Preface. Essential Safety Precautions

Preface. *1 For the compatible models, please refer to the following. SEE Applicable Products (page 5)

RS232C/RS485 Data can be easily monitored by LAN

PS345XA-HD40 Installation Guide. About the Manual. Safety Cautions. URL

Analog Input/Output Modules

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Preface. Copyright 2014 Digital Electronics Corporation. All rights reserved.

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Automationdirect.com

Memory Loader II Operation Manual

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

Preface. Corresponding units: PS-3700A Series units (All product names that appear in this guide are the trademarks of their respective

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE

Analog Input Installation Manual

COMMUNICATION CONVERTER FOR PROFIBUS

1. Essential Safety Precautions

Analog Monitor Installation Manual

USB Data Transfer Cable CA3-USBCB-01 Installation Guide

Safety Precautions. Danger. Flex Network I/O Unit 32-point Input Sink Source / 32-point Transistor Output Sink Type Installation Guide.

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

1. Safety Precautions (Read these precautions before use.)

EX-RC1 Remote I/O Adapter

Model Number Structure

Rear Cover(CA1-RCVLRG-01) Desktop Stand(CA1-STDLRG-01) Installation Guide

Maximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual

PL-HD220 Installation Guide

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-90AW User s Guide CONTEC CO., LTD.

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-30AW User s Guide CONTEC CO., LTD.

Communication Controller CC-Link/CPL Converter CMC10A

RS-232C/485 Isolation Unit Installation Guide. Essential Safety Precautions WARNINGS

MIC-2 MKII Profibus module user s manual

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

WARNING. To Prevent From Damage:

DVPPF02-SL PROFIBUS DP Slave Communication Module

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

EX-RC1 Remote I/O Adapter

PFXGP4601TAD. Pro-face Xycom GP4000 PFXGP4601TAD

PC-HELPER. PCI Express Expansion Chassis Long size, 4-Slots ECH-PE-CE2-F4A. User s Manual CONTEC CO.,LTD.

Installation and Setup

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

PFXGP4503TAD. Pro-face Xycom GP4000 PFXGP4503TAD

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

EX-RC1 Remote I/O Adapter

User s Manual. PCI Bus Expansion Chassis Short x 2Slots ECH(PCI)BE-H2B CONTEC CO.,LTD. PC-HELPER. Long x 2Slots ECH(PCI)BE-F2B

Quick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Conductive Level Controller

PL-FD200 Installation Guide

High Precision Quad Output DC Power Supply

DC I/O Conversion Module

DC I/O Conversion Module FA-TB32XY

VC200 Mobile Phone Tester Please Read before Use

PC-HELPER. PCI Bus Expansion Chassis Short x 4Slots ECH-PCI-CE2-H4A. Short x 7Slots ECH-PCI-CE2-H7A. User s Manual CONTEC CO., LTD.

BGS (at min. setting) BGS (at max. setting)

MU110-6U. Analog output module 6 channel. User guide

PROGRAMMABLE CONTROLLER FP3/FP10S THERMOCOUPLE INPUT UNIT

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Solid-state Timer H3YN

WARNING. To Prevent From Damage:

MODEL: R2K-1 SEN TRONIC AG. R2K Series

CompactFlash for Fix Disk CF-1GB-B, CF-2GB-B, CF-4GB-B, CF-8GB-B User s Guide

About the Manual. ST-3400 Series Installation Guide. Package Contents

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

T1K MODBUS Base Controller Specifications

TVAC25100 TVAC25110 User manual

INSTRUCTION MANUAL GPIB TO USB ADAPTER GUG-001 B

Motorized Curtain Tracks Progress 50 Motor Set

1. Safety Precautions (Read these precautions before use.)

Sensing method Appearance Connection method Sensing distance Output Model. M12 connector 10±3 mm. Size Type Appearance Cable length Model Straight

This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy.

INSTALLATION/USER MANUAL

PC-HELPER. Expansion Adapter for Express Card Slot EAD-CE-EC. User s Manual CONTEC CO.,LTD.

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

S8VE (60/90/120/180/240-W Models)

UL/c-UL(CSA) Application Notes

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Tempco Instruction Manual

User s Manual. PCI Bus Expansion Chassis Short x 2Slots ECH(PCI)BE-H2B CONTEC CO.,LTD. PC-HELPER. Long x 2Slots ECH(PCI)BE-F2B

User s Manual. PCI Bus Expansion Chassis Short x 2Slots ECH(PCI)SF-H2B CONTEC CO.,LTD. PC-HELPER. Long x 2Slots ECH(PCI)SF-F2B

For Sales + Purchasing Info, Click Page To Visit BMI Gaming (800)

USER S MANUAL Linear Programmable DC Power Supply APS

VMC-8114P VMC-8414P INSTRUCTION MANUAL. Colour Video Monitor

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

Transcription:

Preface Thank you for purchasing the Profibus DP unit, hereafter referred to as the Profibus unit. This unit is intended for use with the Digital Electronics Corporation s GP-470/570/675/870 series touch panels (hereafter referred to collectively as the GP ), and as an interface between the Profibus data network and any of the abovementioned GPs. This manual describes the procedures, settings, wiring, etc. required to perform communication on the Profibus network via the GP(s). also, each GP has its own reference manual you can refer to for detailed GP operation information. Before actually beginning to use the Profibus unit, please be sure to the GP s User s Guide s section 1-1 Prior to Operating the GP. The following GP series displays can be used with the Profibus unit. GP-470-EG, GP-570-TC, GP-570-SC, GP-570-TV, GP-571-TC, GP-675, GP-870V All company or manufacturer names used in this manual are the registered trademarks of their respective companies. 1. It is forbidden to copy the contents of this manual, either in whole or in part, except for the purpose of the user s personal use, without the express written permission of the Digital Electronics Corporation of Japan. 2. The information provided in this manual is subject to change without notice. 3. This manual has been written with care, however, should the user discover any errors or omissions, please contact the Digital Electronics Corporation and inform them of your findings. 4. Please be aware that the Digital Electronics Corporation is not responsible for any damages resulting from the use of its products, regardless of article 3 above. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation. IBM DOS are registered trademarks of IBM. GP-470/570 series Profibus User s Manual 1

Preface Table of Contents Preface Preface... 1 Table of Contents... 2 Essential Safety Precautions... 3 Packing Box Contents... 4 Symbols... 5 Chapter 1 Introduction 1-1 Operating the Profibus Unit... 1-1 1-2 System Configuration... 1-2 1-3 When Using Screen Creation Software... 1-2 Chapter 2 Specifications 2-1 Profibus Specifications... 2-1 2-1-1 General Specifications... 2-1 2-1-2 Physical Specifications... 2-2 2-1-3 Performance Specifications... 2-2 2-2 Part Names and Functions... 2-3 Chapter 3 Installation 3-1 Installing the Profibus Unit... 3-1 Chapter 4 Troubleshooting 4-1 Troubleshooting... 4-1 4-1-1 Possible Problems... 4-1 4-1-2 Possible Solutions... 4-1 4-1-3 No Data Communication... 4-3 4-2 Error Messages... 4-5 2 GP-470/570 series Profibus User s Manual

Preface Essential Safety Precautions For the safe and correct use of the Profibus and GP series, be sure to follow the guidelines stated below. Due to the possibility of an electrical shock, be sure that the power supply for the GP is not plugged in when installing the Profibus unit. Do not attempt to modify or alter the Profibus unit. Doing so may cause a fire or an electric shock. To prevent the danger of either personal injury or machinery/material damage, please design your machine s control system so it will not malfunction due to a communication problem between the GP and host controller (PLC). To Avoid Damaging the Profibus unit: Do not allow water, liquids, or metal particles to enter into the Profibus unit s case, since it can cause a malfunction or electrical shock. Avoid storing or operating the Profibus unit in locations where it will be exposed to direct sunlight, high temperature, excessive dust, or vibration. Because the Profibus unit is a precision instrument, do not store or operate it in locations where something may strike or hit the unit. Do not store or operate the Profibus unit where chemicals or acids are stored, or where high concentrations of fumes are present. Do not use paint thinner or organic solvents to clean the outside of the Profibus unit. Instead, soak a soft cloth in a diluted neutral detergent, wring it tightly, and then wipe the unit s outside case. GP-470/570 series Profibus User s Manual 3

Preface Packing Box Contents The Profibus unit s packing box contains the items listed below. Please confirm that everything illustrated here has been included. Profibus Unit GP Series Profibus User s manual (this manual) GP Series (470/570/675/870) Profibus User s MANUAL Ferrite Cores (2) This unit has been carefully packed, however, should you find any item to be either damaged or missing, please contact your local GP distributor immediately for service. 4 GP-470/570 series Profibus User s Manual

Preface Symbols The list below describes the symbols and abbreviations used in this manual. Indicates a potentially hazardous situation which could result in serious injury or even death, if the instructions are not followed. Indicates a potentially hazardous situation which could result in minor injury or equipment damage if the instructions are not followed. Explains a situation that requires a moderate amount of user caution. GP-PRO/PB III Indicates the GP screen editing/creation software, GP-PRO/PBIII. PLC Programmable Logic Controller *1 Indicates supplemental explanatory information is located at the bottom of the page. Indicates additional, relevant information. Reference pages of related sections and topics. The Tag Reference, Operation, Software Operation, PLC Connection, and Parts List Manuals referred to here are those included in the GP-PRO III or GP-PRO/PBIII for Windows 95 software package. Indicates procedure numbers. Be sure to follow these steps to perform a particular task correctly. GP-470/570 series Profibus User s Manual 5

MEMO This page intentionally left blank. 6 GP-470/570 series Profibus User s Manual

Chapter 1Introduction 1-1 Operating the Profibus Unit 1-2 System Configuration 1-3 When Using Screen Creation Software This chapter describes the operation of the Profibus unit and the cautions necessary for correct data communication. 1-1 Operating the Profibus Unit The Profibus unit allows one of the following GP series units to be connected directly to a PLC that supports the Profibus network. <How to set up the Profibus unit> CPU Connection Diagram Data Cable I/F Module GP Types Siemens S7-300 Series i.e. S7 315-2-DP See Cable Wiring Diagram 1 RS-485 Profibus-DP Module (GP070-PF11) GP 470E GP-570L GP-570S GP-570T GP-675 GP-870VM GP-470/570 series Profibus User s Manual 1-1

Introduction 1-2 System Configuration Use RS-485 cables to make the connection. This will allow for a maximum of 64 slaves, in DIO mode, with the Seimens S7-300. With same Seimens PLC, and using Packet mode the limilt is four (4) slaves. Siemens RS-485 RS-485 GP GP... to a maximum of 64 slaves GP 1-3 When Using Screen Creation Software When selecting the PLC type to use on your screen creation software, choose Profibus. For detailed selection procedures, refer to the Operation Manual for the respective screen creation software. When using the GP-PRO/PB III for Windows 95 software, refer to 1-8-2 Select a Project/Create a New Project in the GP-PRO/ PB III for Windows 95 Operation Manual. When using the GP-PRO/PB III (DOS) software, refer to 1-5-2 Select Project in the GP-PRO/PB III Operation Manual. 1-2 GP-470/570 series Profibus User s Manual

Chapter 2-1 Profibus Specifications 2-2 Parts Names and Functions 2Specifications This chapter describes the specifications, names, and figures for the Profibus unit. 2-1 Profibus Specifications 1 General Specifications Rated voltage 5 VDC ±5% (supplied by the GP unit) Power consumption Less than 3 W (Typically 1.9W) Voltage capacitance 1500 VAC, 20 ma 1 min. (between live and FG terminals) Insulation resistance 500 VDC, more than 10 MΩ (between live and FG terminals) Ambient operating temperature 0 to 50ºC (Do not operate in temperatures in excess of GP s specified range) Ambient operating humidity 30 to 85% RH (Do not operate in areas where humidity is higher than GP s specified range) Ambient storage -10 to 60ºC temperature Ambient storage humidity 20 to 85% RH (no condensation) Vibration resistance 10 to 25 Hz (X, Y, Z directions for 30 minutes each at 2G) Noise endurance Noise voltage: 1000 Vp_p Pulse length: 1 µs Rise time: 1 ns (with simulator) Operating Atmosphere Free of corrosive gases Grounding Class 3 GP-470/570 series Profibus User s Manual 2-1

Specifications 2 Physical Specifications Usage External dimensions Weight Cooling method Installed as an option board in GP-470/570 series(large units) s expansion slots 167(W) x 116.1(H) x 25.1(D) (mm) (Main unit only, including terminal block) Approx. 330 g Natural air circulation 3 Performance Specifications Memory 2-port RAM: 1KB GP connection I/F GMU buses Address bus: 16-Bit Data bus: 8-Bit Interrupt function: 1 ch (IRQ A, FIX) Communication I/F Connector used: D-SUB 9-pin Input/output : Complies with RS-485 (insulated type) Transfer rate: 12 Mbps 1500 kbps 500 kbps 187.5 kbps 93.75 kbps 19.2 kbps 9.6 kbps Recommended cable: EIA RS-485 twisted pair Terminating resistor: Built-in (turns ON/OFF via DIP switches) 4 Usage Environment Specifications 1. Gp Data Transfer Settings GP Settings Data Transfer Speed 9.6K to 12Mbps *1 Data Transfer Method RS-485 System Area Start Address DB2W0 DB60W65514 Station No. 0-127 : Default Settings *1 : The data transfer speed is automatically changed, according to the ladder software s specifications. Thus, setting this speed via the GP is uneeded. *2 : Station No.s are set via the Profibus Rotary Switches. 2-2 GP-470/570 series Profibus User s Manual

Specifications 2-2 Parts Names and Functions Profibus Unit LED Indicators The figure below shows the Top-Mounted placement of the Profibus module s LED indicators. Top Mounted LED Unit Power LED DIA LED ERROR LED R E D G R E E N The following table shows the function of each LED indicator: LED NAME COLOR FUNCTION ERR RED Lit: Normal Operation Unlit: Bus is OFF or has error DIA (NONE) Not Used POWER GREEN Lit: Power is ON Unlit: Power is OFF Terminating the First and Last Profibus Module The first and last Profibus module must be terminated for the bus unit to operate properly. To do this, simply turn on the terminating switch on the first and last Profibus I/F unit. (See figure below) Also, be sure to turn all other Profibus unit termination switches OFF. Profibus Unit Rotary Switches The rotary switches are used to set the Profibus-DP slave node number. These must be set to the same value as that specified in the Profibus-DP slave configuration. If the GP is to be the last node on the Profibus-DP network, then the TERM switch must be set to the ON position to mark the network termination. The diagram below shows an example where the node address is set to 1, thus the rotary switches are set to 0 1. ON 1 0 1 9 2 8 3 7 6 5 4 0 1 9 2 8 3 7 6 5 4 GP-470/570 series Profibus User s Manual 2-3

Data Cable Wiring The following cable diagram should be used when making a cable for the Profibus-DP cable s connector. <Cable Wiring Diagram> Station 1 Station 2 (9-pin) (9-pin) RxD/TxD-P (3) DGND (5) VP (6) RxD/TxD-N (8) (3) RxD/TxD-P (5) DGND (6) VP (8) RxD/TxD-N Protective Ground Be sure to earth the PLC s FG according to Class 3 earthing standards. (For details, please refer to the PLC maker s manual) Collect all the data cable s shield wires and connect them to the PLC s FG. *1 Cable Data (for S7315-2-DP model) Parameters: Line A Line B, according to Profibus-DP DIN 19245 part1/4.91, section 3.1.2.3 Wire Gauge: >0.64mm >0.53mm Conductor Area: >0.34mm 2 >0.22mm 2 1* Be sure to attach the ferrite cores shown below to the data transfer cables leading to the Profibus unit, and use a D-sub connector with a metal case. This will help to suppress the effect of any noise created by surrounding equipment. TDK ferrite cores, or their equivalent, are recommended. Ferrite Cores: model name: ZCAT2035-0930A (TDK Co.), or equivalent D-sub 9pin connector (Metal case) Profibus Unit 2-4 GP-470/570 series Profibus User s Manual

Chapter 3-1 Installing the Profibus Unit 3Installation This chapter describes how to install and wire the Profibus unit and how to set the Profibus address. 3-1 Installing the Profibus Unit To install the Profibus unit in the GP, follow the steps below. WARNING Before installation Due to the possibility of an electrical shock, be sure the GP s power cord is not plugged in to the power supply. Be sure not to touch the surface of the printed circuit board. Disconnect the power cable from the GP Use a screwdriver to unscrew the GP rear cover s 2 attachment screws and remove the rear cover. Attachment screws Profibus Unit Rear of GP * This figure describes how to install the Profibus module into a GP-470 series display unit. GP-470/570 series Profibus User s Manual 3-1

Installation Protruding tabs Be careful not to touch the surface of the Profibus unit s printed circuit board. Holes for installing the unit Insert the protruding tabs of Profibus unit into the installation holes. Be sure to install the unit so that the smooth metal face of the Profibus unit points outward. Be careful not to touch the surface of the Profibus unit s printed circuit board. Screw holes Hold the GP with your left hand and insert the Profibus unit into its slot with your right hand. Be sure that the unit is seated correctly in place, so that no gaps remain between the GP and the Profibus unit. Attachment Screws Reattach the attachment screws and secure the Profibus unit to the GP. 3-2 GP-470/570 series Profibus User s Manual

Chapter 4-1 Troubleshooting 4-2 Error Messages 4Troubleshooting This chapter describes the usual troubleshooting procedures to use when a problem occurs with the Profibus unit. 4-1 Troubleshooting The following section describes standard problems and their possible solutions. 1 Possible Problems The most common problems that could occur while operating the GP are as follows: (1) No Data Communication Data communication does not take place between the GP and Host. In some cases, an error message will be displayed on the screen. For error messages, refer to 4-2 Error Messages, and the respective GP unit s User s Manuals. (2) OFFLINE mode menu appears on the main unit during operation. 2 Possible Solutions For problem (1), use the following troubleshooting flowchart to diagnose the problem s cause and find a possible solution. For problem (4), the cause may be due to a main (GP) unit system error. Please remember that the GP unit s OFFLINE mode will display if you touch the upper left corner of the screen within 10 seconds after start-up. GP-470/570 series Profibus User s Manual 4-1

Troubleshooting WARNING Before installing the Profibus DP unit: Before beginning installation, due to the possibility of an electrical shock, be sure the main unit (GP) s power cord is unplugged from the power supply. This chapter describes only GP unit problems, and assumes there are no PLC problems. For PLC problem causes, please refer to the PLC maker s Operation Manual. 4-2 GP-470/570 series Profibus User s Manual

Troubleshooting 3 No Data Communication If the GP can not communicate with the host, follow the flowchart described below to find the cause of the trouble and correct the problem. In cases where an error message is displayed on the GP s screen, check the error code list and correct the problem. Refer to 4-2 Error Messages, and the respective GP unit s User s Manuals No data communication can be performed Turn off the GP s power supply. Has the PLC type info. been entered correctly? YES NO Select Target PLC when entering the PLC type. Refer to 1-3 When Using Screen Creation Software, as well as the GP-PRO/PB III Operation Manual Has the Profibus unit been installed correctly? YES NO Insert the Profibus unit correctly and tighten the attachment screws securely. Refer to 3-1 Installing the Profibus Unit Have the Profibus unit connector pins been bent? YES Contact your local distributor. NO Has the address setting for the Profibus been set correctly? NO Confirm that the rotary switch address settings for the Profibus unit are correct. Refer to Section 2-2 Part Names and Functions for details. YES GP-470/570 series Profibus User s Manual 4-3

Troubleshooting Has the Profibus unit been installed correctly? YES Turn ON the power supply NO Check that none of the connector pins have become bent or skewed. Then, reinstall the Profibus unit in the back of the GP so that its connector is correctly connected. Does the ERR LED light up? NO Does the PWR. LED light up? YES YES YES Is the network configured correctly? NO Configure the network correctly. NO Contact your local distributor for assistance and possible replacement of the unit. Assuming an authorized replacement unit has been sent to you. NO Does the unit communicate normally? YES OK/Finished YES Does the new Profibus unit communicate normally? NO The GP unit may be defective. Contact your local distributor for further assistance. The original Profibus unit is defective. 4-4 GP-470/570 series Profibus User s Manual

Troubleshooting 4-2 Error Messages The PLC does not respond (02:FE) This error message is displayed when a time-out occurs while receiving data or there is too much noise on the line. The possible causes are described below. Select the solution below that applies to your particular problem. Cause The master PLC s power is OFF, or in stop mode. The PLC and the GP have been turned on in the wrong order. The communication cable is not connected properly. PLC Communication Error Solution Turn on the PLC power supply. First turn on the GP power supply, then turn on the PLC power supply after 2 to 3 seconds. Check the wiring of the communication cables, and wire them correctly. One possible cause of this error message is that the address value set for the tag exceeds the range specified by the processor. Check the displayed error number, and proceed by following the respective solutions. PLC Communication Error ( 02 : x x) 0 2 : x x Error No. Error No. F6 Solution 1) Be sure that your screen data uses only the designated LS area(s). 2) Reset the System Area (to all zeroes). Target PLC has not been set up This error message is displayed when data other than that used by the target PLC is transferred. Reinitialize the GP, and then send the correct data. GP-470/570 series Profibus User s Manual 4-5

Troubleshooting MEMO This page intentionally left blank. 4-6 GP-470/570 series Profibus User s Manual