MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Similar documents
PANEL MOUNT INTERCOMS

810D Series FAA L-810 Double Obstruction Light Installation Manual

PowerLogic High Density Metering System 1-Meter Enclosure

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Informer Sensor/Radio Interface Unit

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

PV Rapid Shutdown device

INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL EZ1 ECHO INTERCOMS

Multi Unit Enclosed Meter

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

NI PXIe-1062Q Power Supply Shuttle

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Model 7705 Control Module

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

C-POWER AC AUTOMATIC CONTROL

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

MAXIMA+ Series Rotary Level Indicator

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

IMPORTANT SAFETY INSTRUCTIONS

hp uninterruptible power system r12000 xr models installation instructions

PS/IO Circuit Board Retrofit

RAINPROOF* COLOR CAMERA SECURITY SYSTEM

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

M215 (M215-60) Safety

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

PanelView Plus/VersaView CE Terminals and Display Modules

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- RELAY OUTPUT FR-A5AR

MAXIMA + Series ROTARY LEVEL CONTROL

High Speed Remote I/O Module

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Series Amp Pad Mount Quick Connect Input and Output Power Panels

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

ETC Installation Guide

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Service Instructions. Conductor 420

Masibus Automation And Instrumentation Pvt. Ltd.

FLP-PS DC Power Supply Model. Portable Sound System Mixer Amp/ Pre Amp/ Power Amp

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

Single Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL

M250 (M LL) Safety

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

VECTOR INVERTER -INSTRUCTION MANUAL- HIGH RESOLUTION ANALOG INPUT / EXTRA CONTACT INPUT / THERMISTOR INTERFACE FR-V5AX

Model GHz 50 Ohm RF Module

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Installation Job Aid for Ethernet Routing Switch 3600 Series

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

Instruction Manual: IM E

Setup and Instruction Manual

Installation Job Aid for Ethernet Routing Switch 5900 Series

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

OPLC Installation Guide

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Manual No: Revision: F. Relay Output Modules. Installation Guide

Analog Monitor Installation Manual

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Model 2657A-LIM-3 LO Interconnect Module

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

INSTRUCTION MANUAL A141 High Level Audible Warning System

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

High Precision Quad Output DC Power Supply

Installing the Cisco MDS 9020 Fabric Switch

YASKAWA AC Drive-1000 Series Option Operator Mounting Kit NEMA Type 4X, IP66 Installation Manual Model No.: UUX or UUX000527

Enphase S-Series Microinverter and Engage Cable Safety

Installation and Operations Manual. Electronic copies available at (Rev_ )

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

TRC-190 User s Manual

E1135C PDU and Pod Upgrade Procedure

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

Tesla TI Generator Set Interface

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Solar Combiner Enclosure

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

SAVE THESE INSTRUCTIONS

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Secondary Surge Arrester Instruction Manual Page 1 of 5

V E1B Snap-in I/O Module

Temperature. Power requirements. Weight. Dimensions

Progressive Industries, Inc. EMS Electrical Management System

Cutter Option Installation Instructions

Basketball Shot Clock Set LX2180 Manual

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

3M Wrist Strap and Ground Monitor 773. User s Guide

M215-Z Safety Information (M LL-IG-ZC)

Transcription:

MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT

INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state signalling device that can be used for general purpose signalling. Any one of three distinctive signalling tones may be selected by dry contact closure at the appropriate connections of J4. The tone can easily be changed if the signalling requirements change. The Model can be installed either indoors or outdoors. B. SPECIFICATIONS. Operating Voltage 120/240VAC 50-60Hz, 24VDC Operating current Voltage Current 120VAC 210MA 240VAC 120MA 24VDC 600MA Sound Output db(a) @ 10' db(a) on Axis UL Rating Wail 109.5 100 Yelp 111 100 Horn 107 94 Weight (approx.) 4.4 lbs. (2.173Kg) Dimensions (HWD) 14.5" x 12" x 9" C. UNPACKING. After unpacking the unit, examine it carefully for damage that may have occurred in transit. If the equipment has been damaged, file a claim immediately with the carrier, stating the extent of the damage. Before proceeding, ensure that the parts listed in the KIT CONTENTS LIST have been supplied. D. KIT CONTENTS LIST. Qty. Description Part Number 1 Adapter K8476121A-04 1 Gasket, Adapter K8476122A 1 Connector Plug, 4-Position K140340B 1 Connector Plug, Tone Selector K140389A-04 E. INSTALLATION. SAFETY MESSAGE TO INSTALLERS People s lives depend on safe installation of our products. It is important to follow all instructions shipped with the products. This device is to be installed by a trained electrician who is thoroughly familiar with the National Electrical Code and will follow the NEC Guidelines as well as local codes. The selection of the mounting location for the device, its controls and the routing of the wiring is to be accomplished under the direction of the Facilities Engineer and the Safety engineer. In addition, listed below are some other important safety instructions and precautions you should follow: Read and understand all instructions before installing or operating this equipment. Do not connect this unit to the system when power is on.

Optimum sound distribution will be severely reduced if any objects are in front of the speaker. You should ensure that the front of the speaker is clear of any obstructions. All effective warning speakers produce loud sounds which may cause, in certain situations, permanent hearing loss. You should take appropriate precautions such as wearing hearing protection. All effective warning speakers produce loud sounds, which may cause, in certain situations, permanent hearing loss. The device should be installed far enough away from potential listeners to limit their exposure while still maintaining its effectiveness. The OSHA Code of Federal Regulations 1910.95 Noise Standard provides guidelines which may be used regarding permissible noise exposure levels. After installation, ensure that all bolts and threaded joints are tightened. Establish a procedure to routinely check the sound system for proper activation and operation. Provide a copy of these instructions to the Safety Engineer, operator(s) and maintenance personnel. File these instructions in a safe place and refer to them when maintaining and/or reinstalling the device. Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death to you or others. The Model can be attached to any relatively flat surface or to a variety of electrical wall boxes. A four position plug is supplied for electrical power connection. In addition, two #8-32 x 3-1/4" slotted machine screws are included to attach the unit to a four-inch square electrical box. After the mounting method and location have been selected, follow the procedure in the appropriate paragraph of this section. The speaker portion of is not shown in the installation figures for clarity. The speaker and its base assembly provides three degrees of freedom, allowing the horn to be oriented for any coverage pattern desired. Adjustment is accomplished with hand tightened nuts which require minimal torque to maintain horn position. When mounted outdoors, ensure that the rain guard on the swivel base is oriented to protect the speaker wire openings from falling rain. CAUTION Always provide sufficient support of the mounting boxes used to mount the horn. Failure to do so may result in property damage, serious injury or death to you or others. 1. Weatherproof Mounting in WB Box. a. See figure 1. Insert the two #8-32 x 3-1/4" slotted pan head screws into the base at opposite corners. b. Install the adapter gasket in the adapter, and place the adapter with installed gasket over the screws inserted in step a. c. Secure the base/adapter assembly in the WB with the pan head screws as shown in figure 1. 2. Wall Mounting. Wall mounting the in an NB or NBL box is accomplished using the adapter, adapter gasket, and the #8-32 x 3-1/4" pan head screws as shown in figure 2. a. See figure 2. Insert the two #8-32 x 3-1/4" slotted round head screws into the base at opposite corners. b. Install the adapter gasket in the adapter, and place the adapter with installed gasket over the screws inserted in step a. c. Secure the base/adapter assembly in the NB or NBL box with the pan head screws as shown in figure 2. -2-

3. Surface Mounting. Surface mounting the in an NB or NBL box is accomplished using the adapter, adapter gasket, and the #8-32 x 3-1/4" pan head screws. Use figure 2 as guide. a. See figure 2. Insert the two #8-32 x 3-1/4" slotted pan head screws into the base at opposite corners. b. Install the adapter gasket in the adapter, and place the adapter with installed gasket over the screws inserted in step a. c. Secure the base/adapter assembly in the NB or NBL box with the pan head screws as shown in figure 2. 4. Concealed Conduit Mounting. The concealed conduit mounting method is shown in the figure 3. This mounting method is recommended when an existing junction box or handy box will not accommodate the Model. In order to accomplish this type of mounting, a Federal Model NBL Outlet Box and an adapter plate are required. A pair of 6-32 and 8-32 flat head screws are included with the concealed mounting kit to secure the plate to the existing box. Two 10-32 x 1/4" round head screws are supplied to attach the NBL box to the plate. An insulated bushing is also supplied to protect electrical leads passing through the center knockout of the NBL box. F. POWER CONNECTIONS. Make sure that the AC power is off. When the unit is to be operated from an AC source, set the voltage selector switch SW1 to the desired source voltage. CAUTION Use only 12 to 18 AWG wire for power connection. Strip no more than 0.25-inch of wire insulation from the ends of the power leads. Connect the AC power leads to the 120/240VAC terminals of the four position connector plug supplied with the unit by inserting the stripped ends of the wire into the connector as far as they can travel. Make sure supply lead insulation is flush with connector. If stranded wire is used, be sure that there are no loose strands outside the connector plug that could touch the adjacent lead and cause a short circuit. Plug the connector into the receptacle provided on the printed circuit board. For 24VDC operation, remove the jumper and connect the positive lead to the (+) terminal and negative lead to the (-) terminal of the four position connector as shown in figure 4. Choose either AC or DC power operation. Do not try to operate the unit by connecting both AC and DC power sources at the same time. G. TONE ACTIVATION WIRING. 1. Remote Tone Activation Connection. Make sure that AC or 24VDC operating power to the unit is off. The remote tone activation can be accomplished by applying a dry contact closure at J4 plug (see figure 1) between GND terminal and one of the tone (WAIL, YELP, HORN) terminals. Use #18AWG shielded twisted pair wires, strip no more than 0.25-inch of wire insulation from the ends of leads to connect remotely located tone activating dry contact terminals between GND and WAIL, YELP or HORN terminal of four position connector plug supplied with unit. Make sure the lead insulation is flush with connector. If stranded wire is used, be sure that there are no loose strands outside the connector plug that could touch adjacent lead and cause a short. Plug the connector into the receptacle J4 on the printed circuit board. The selected tone will play when unit is powered up and remote activation contacts are closed. For proper operation of the remote activating circuit the total loop (resistance of GND wire plus resistance of tone terminal wire plus the dry contact resistance) resistance of the circuit should not exceed 1000 ohms. -3-

Connecting a dry set of contacts for each of three tones, any one tone can be activated by closing the appropriate contact. When contact closures are applied to all tone terminals simultaneously, HORN tone will override the other two tones. If contact closures are applied to HORN and any other tone HORN tone will override the other tone. If contact closures are applied to WAIL and YELP, the WAIL tone will override the YELP tone. 2. Wiring for Single Tone Activation at Power-Up. Make sure that AC or 24VDC operating power to the unit is off. The unit can be operated by switching operating power (AC or 24VDC) ON to the unit if a permanent short wire jumper is installed between GND and the desired tone terminal of the four-position connector plug instead of dry contact closure. Connect a short (1" long) #22 AWG wire between GND and the desired tone terminal of the four position remote tone activation terminal connector plug supplied with the unit. Plug the connector into the J4 receptacle (see figure 1) on the printed circuit board. Switching ON the operating power will now activate the unit. H. SERVICE. SAFETY MESSAGE TO MAINTENANCE PERSONNEL Read and understand all instructions before performing any maintenance to this unit. To reduce the risk of electrical shock or ignition of hazardous atmospheres, do not perform maintenance/service on this device when circuits are energized. Optimum sound distribution will be reduced if speaker becomes clogged with a foreign substance. Periodic checks should be performed to ensure foreign substances are not packed into the speaker. Any maintenance to the unit MUST be performed by a trained electrician in accordance with NEC Guidelines and local codes. Never alter the unit in any manner. Safety in hazardous locations may be endangered if additional openings or alterations are made in units specifically designed for use in these locations. The nameplate, which may contain cautionary or other information of importance to maintenance personnel, should not be obscured if exterior of housings used in hazardous locations are painted. Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death to you or others. The Federal factory will service your equipment or provide technical assistance with any problems that cannot be handled locally. Any units returned to Federal Signal for service, inspection or repair must be accompanied by a Return Material Authorization. This R.M.A. can be obtained from your local Distributor or Manufacturer s Representative. At that time a brief explanation of the service requested, or the nature of the malfunctions, should be provided. I. REPLACEMENT PARTS. Description Board Assy, Connector Plug, 4-position Connector Plug, Tone Selector Part Number K2001177 K140340 K140389A-04-4-

1 GASKET ASSEMBLED DETAIL WB GASKET 8-32 x 3-1/4" SCREWS(2) WB BASE ASSEMBLY GASKET (SECTIONAL VIEW) WB GASKET (REF.) 290A4032-01 2 ASSEMBLED DETAIL NB, OR NBL BOX GASKET NB OR NBL 8-32 x 3-1/4" SCREWS(2) BASE ASSEMBLY GASKET (SECTIONAL VIEW) WALL 290A4032-02 -5-

3 ASSEMBLED DETAIL NB, OR NBL BOX GASKET NBL 8-32 x 3-1/4" SCREWS(2) CC BASE ASSEMBLY (SECTIONAL VIEW) 290A4032-03 4 J3 JUMPER SW1 TONE SELECTOR CONNECTOR, J4 POWER CONNECTOR PLUG, J3-24VDC + 120/240 120V 240V J3 SW1 SSTX-MV PRINTED CIRCUIT BOARD AC VOLTAGE SELECTOR SWITCH, SW1 HORN WAIL YELP GND J4 FOR YELP TONE J4 YELP GND FOR WAIL TONE J4 WAIL GND FOR HORN TONE J4 HORN GND 290A4032-04 2561620A REV. A 300 Printed in U.S.A.