XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)

Similar documents
XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

XU1-DC DC voltage relay. (June 1998) Manual XU1-DC (Revision New)

XG2 Generator-/Mains Monitor. Manual XG2 (Revision A)

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

BN1-400 Mains decoupling relay. (February 2000) Manual BN1-400 (Revision New)

MRA1 Trip circuit supervision. Manual MRA1 (Revision A)

MRT1 Test Unit. Manual MRT1 (Revision A)

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Contact protection relay

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.21

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-ERD.12

Electronic timer CT-ARS.11

Electronic timer CT-AHD.22

TRIO-DIODE/12-24DC/2X10/1X20

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

QUINT-BUFFER/24DC/24DC/40

02/11/2015

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

STEP-PS/1AC/24DC/1.75

MRP2-S3 Apparent Power Relay. Manual MRP2-S3 (Revision A)

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

RM4JA32MW current measurement relay RM4-J - range A V AC DC

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Three-phase monitoring relay

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RM4JA01F current measurement relay RM4-J - range ma V AC

Power supply CP-C 24/5.0

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Messaging module CP-C MM

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Switching relay CT-IRE with 1 c/o (SPDT) contact

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

RM4TR31 three-phase network control relay RM4-T - range V

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Earth-fault Relay SPAJ 110 C. Product Guide

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Installation / Control Technique

PHOENIX CONTACT - 07/2006

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

MINI-PS AC/10-15DC/8

MPR 10. Digital Motor Protection Relay. P&B Engineering Belle Vue Works Boundary Street Manchester M12 5NG

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

FL MC 2000E (SM40) LC

Arc protection relay. Features Three-phase overcurrent function. Application

Residual overvoltage relay

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

RM4UA33M voltage measurement relay RM4-U - range V V AC

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

Power Supply HARTING pcon

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM4JA31M current measurement relay RM4-J - range ma V AC

Thermistor motor protection relay CM-MSS.21

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

MINI MCR-SL-PT100-UI(-SP)(-NC)

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Binary output and supervision 520CSD01 Data sheet

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

MINI MCR-SL-UI-REL(-SP)

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

DC561, digital input/output module,

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

02/11/2015

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Thermistor motor protection relay CM-MSS.41

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Transcription:

XE2 DC current relay for loss of excitation protection Manual XE2 (Revision A)

Woodward Manual XE2 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by Woodward Governor Company is believed to be correct and reliable. However, no responsibility is assumed by Woodward Governor Company unless otherwise expressly undertaken. Woodward 1994-2008 2 DOK-TD-XE2 Rev.A

Manual XE2 GB Woodward Inhalt 1. Applications and features... 4 2. Design... 5 3. Function... 6 4. Operation and settings... 8 4.1 Setting of DIP-switches... 9 4.2 Setting of the tripping values... 10 4.3 Communication via serial interface adapter XRS1... 11 5. Relay case and technical data... 12 5.1 Relay case... 12 5.2 Technical data... 13 DOK-TD-XE2 Rev.A 3

Woodward Manual XE2 GB 1. Applications and features DC current relay XE2 is used for supervision of the ex-citer current. By the exciter current element the direct current of the excitation machine in brushless machines is supervised. The protection function includes detection of overcurrent and undercurrent as well as supervision of the ripple component of the exciter current and so faults of the rotating diodes would be revealed. When compared to the conventional protection equipment all relays of the PROFESSIONAL LINE reflect the superiority of digital protection techniques with the following features: High measuring accuracy by digital data processing Fault indication via LEDs Extremely wide operating ranges of the supply voltage by universal wide-range power supply Very fine graded wide setting ranges Data exchange with process management system by serial interface adapter XRS1 which can be retrofitted Extremely short response time Compact design by SMD-technology In addition to this the XE2 has the following special features: Galvanically decoupled measuring input of the exciter current 0.2-15 A Trip delay and limits for overcurrent and undercurrent can separately be set Supervision of rotating diodes by means of measuring the ripple component of the exciter current 4 DOK-TD-XE2 Rev.A

Manual XE2 GB Woodward 2. Design Figure 2.1: Connections Analog inputs The exciter current is fed to the protection relay via terminals I+ and I-. Auxiliary voltage supply The XE2 needs a separate auxiliary voltage supply. Therefore a DC or AC voltage must be used. The XE2 has an integrated wide range power supply. Voltages in the range from 19-390 V DC or 36-275 V AC can be applied at connection terminals A1 and A2. If a DC auxiliary voltage is used, the connection polarity at terminals A1-A2 is optional. Contact positions Figure 2.2: Contact positions of the output relays DOK-TD-XE2 Rev.A 5

Woodward Manual XE2 GB 3. Function Failures in the excitation system of a synchronous generator may cause severe damage to the rotor of the generator as well as undesirable operating conditions: Failure AVR failure; undercurrent in parallel operation AVR failure; undercurrent in single operation AVR failure; overcurrent in parallel operation AVR failure; overcurrent in single operation Rotating diode open Rotating diode short Effect Excessive reactive current flow to the generator => System stability endangered (machine may slips, asynchronous torque) System undervoltage if single operation => System stability endangered Excessive reactive current flow to the system => Thermal overload of the exciter and stator winding System overvoltage if in single operation => Thermal overload of the exciter and stator winding Diodes overloaded => further diode faults Excessive exciter current => severe overheating of the rotor system within a very short time. De-energizing and disconnection of the generator should be carried out within approx. 10 s. Table 3.1: Effects of different failures Exciter current supervision: The exciter current supervision comprises of three elements: under- and overcurrent and ripple component measurement. Those elements cover above mentioned failures of the generator excitation system. Undercurrent protection: If the exciter current I e falls below the set value I<, the relay trips after the set time delay ti<. The current setting I e should be chosen at about 70% of the no load exciter current of the generator. The corresponding time delay should be set to a value well above the AVR response time (e.g. 2 s), to allow transient deexcitation of the generator due to voltage regulator operation. Overcurrent protection: Function of the overcurrent protection is similar to that of the undercurrent protection. If the set value is exceeded, the relay trips after the set time delay. The current setting I e should be chosen at about 120% of the nominal exciter current of the generator. The time delay should be set to a value well above the AVR response time and required short circuit, to allow transient over-excitation of the generator due to voltage regulator operation. Diode failure protection: The diode failure protection is based on the measurement of the ripple component of the exciter current related to the mean value of the exciter current as per following formula: %,, 100 6 DOK-TD-XE2 Rev.A

Manual XE2 GB Woodward Condition of diodes I R All diodes all right: I R 15...20% One diode open: I R 110% One diode short: I R 200% Table 3.2: Typical values for IR The setting of IR> should be chosen in the range from 40% to 50%. IR> trips with a fixed time delay of 4 s. Note! The required settings depend on various factors like: Required power factor of the generator Required minimum short circuit duration etc. DOK-TD-XE2 Rev.A 7

Woodward Manual XE2 GB 4. Operation and settings All operating elements needed for setting parameters are located on the front plate of the XE2 as well as all display elements. Because of this all adjustments of the unit can be made or changed without disconnecting the unit off the DIN-rail. Figure 4.1: Front plate For adjustment of the unit the transparent cover has to be opened as illustrated. Do not use force! The trans-parent cover has two inserts for labels. Figure 4.2: How to open the transparent cover 8 DOK-TD-XE2 Rev.A

Manual XE2 GB Woodward LEDs LED ON is used for display of the readiness for service (at applied auxiliary voltage Uv). LED I>, IR> and I< signal pickup (flashing) or tripping (steady light) of the corresponding function. Test push button This push button is used for test tripping of the unit and when pressed for 5 s a check-up of the hardware takes place. Both output relays are tripped and all tripping LEDs light up. If DIP-switch 1 is in ON position the TEST push button has an additional function. It then serves additionally for resetting the I>/IR> output relay after tripping. For this purpose, briefly press push button (<5 s). 4.1 Setting of DIP-switches The DIP-switch block on the front plate of the XE2 is used for adjustment of the nominal values and setting of function parameters: DIP-switch OFF ON Function 1 OFF ON Relay latching I>/IR> 2 3 4 active blocked Exciter overcurrent element I> 5 active blocked Exciter undercurrent element I< 6 active blocked Ripple component supervision IR> 7 x 1 x 10 Multiplier for ti> 8 x 1 x 10 Multiplier for ti< Table 4.1: Functions of DIP-switches Blocking of overexcitation element When DIP switch 4 is in "ON" position, the overexcitation element is blocked. Blocking of underexcitation element When DIP switch 5 is in "ON" position, the underexcitation element is blocked. Blocking of ripple component supervision When DIP switch 6 is in "ON" position, the ripple component supervision is blocked. Relay latching If DIP-switch1 is in position "ON", the output relay I>/IR> will only return to is original position after tripping if the fault has been cleared and the TEST/RES. key is pressed. The relay can also be reset electrically e. g. by a NC contact in the aux. voltage supply (interruption >2 s). DOK-TD-XE2 Rev.A 9

Woodward Manual XE2 GB 4.2 Setting of the tripping values The PROFESSIONAL LINE units have the unique possibility of high accuracy fine adjustments. For this, two potentiometers are used. The coarse setting potentiometer can be set in discrete steps of 2.5 A. A second fine adjustment potentiometer is then used for continuously variable setting of the final 0-2.5 A. Adding of the two values results in the precise tripping value. Exciter overcurrent I> By using potentiometers shown on fig. 4.3, the over-excitation element I> can be adjusted in the range from 0-15 A (I> min. = 0.2 A). The dropout to pickup ratio (hysteresis) is 5 %. Example : The tripping value intended to be adjusted is 9 A. So the setting value of the right potentiometer is simply added to the value of the potentiometer for coarse adjustment. (The arrow of the coarse setting potentiometer must be inside the marked bar, otherwise no defined setting value). Figure 4.3: Adjustment example Supervision of exciter undercurrent I< By using potentiometer I<, the underexcitation element I< can be adjusted in the range from 0-5 A (I< min = 0.2 A). The dropout to pickup ratio (hysteresis) is 5 %. Ripple component supervision IR> By using potentiometer IR>, the ripple component supervision IR> can be adjusted in the range from 0-125 %. (IR> min = 10 %; hysteresis = 5 %). Time delay ti> By using DIP switch 7, time delay ti> for supervision of exciter overcurrent I> can be adjusted infinitely from 0-5 s or 0-50 s. Time delay ti< By using DIP switch 8, time delay ti< for supervision of exciter undercurrent I< can be adjusted infinitely from 0-5 s or 0-50 s. 10 DOK-TD-XE2 Rev.A

Manual XE2 GB Woodward 4.3 Communication via serial interface adapter XRS1 Figure 4.4: Communication principle For communication of the units among each other and with a superior management system, the interface adapter XRS1 is available for data transmission, including operating software for our relays. This adapter can easily be retrofitted at the side of relay. Screw terminals simplify its installation. Optical transmission of this adapter makes galvanic isolation of the relay possible. Aided by the software, actual measured values can be processed, relay parameters set and protection functions programmed at the output relays. Information about unit XRS1 in detail can be taken from the description of this unit. DOK-TD-XE2 Rev.A 11

Woodward Manual XE2 GB 5. Relay case and technical data 5.1 Relay case Relay XE2 is designed to be fastened onto a DIN-rail acc. to DIN EN 50022, the same as all units of the PROFESSIONAL LINE. The front plate of the relay is protected with a sealable transparent cover (IP40). Figure 5.1: Dimensional drawing Connection terminals The connection of up to a maximum 2 x 2.5 mm 2 cross-section conductors is possible. For this the transparent cover of the unit has to be removed (see para. 4). 12 DOK-TD-XE2 Rev.A

Manual XE2 GB Woodward 5.2 Technical data Measuring input circuits Rated frequency: 0-300 Hz Thermal withstand capability in current circuit: during 10 s 5 x In continuously 2 x In Power consumption in current path: at In = 10 A 0,2 VA Exciter current measuring: Rated exciter current In: 10 A DC (measuring range up to 17 A DC) Power consumption in measuring path: <1 VA Auxiliary voltage Rated auxiliary voltage Uv/ Power consumption: 19-390 V DC or 36-275 V AC (f = 40-70 Hz) 4 W (terminals A1-A2) Maximum interruption time UV = 24 V DC: tu = 8 ms, UV = 48 V DC: tu = 35 ms of auxiliary voltage tu UV > 60 V DC: tu = 50 ms Common data Dropout to pickup ratio: >95 % Resetting time from pickup: <40 ms Returning time from trip: 500 ms Minimum initialization time after supply voltage has applied: 200 ms Minimum response time when supply voltage is available: <120 ms Output relay Number of relays: 2 Contacts: 1 changeover contact for each trip relay Maximum breaking capacity: ohmic 1250 VA / AC resp. 120 W / DC inductive 500VA / AC resp. 75 W / DC Maximum rated voltage: 250 V AC 220 V DC ohmic load I max = 0,2 A inductive load I max = 0,1 A at L/R 50 ms 24 V DC inductive load I max = 5 A Minimum load: 1 W / 1 VA at U min 10 V Maximum rated current: 5 A Making current (16ms): 20 A Contact life span: 10 5 operations at max. breaking capacity Contact material: AgCdO System data Design standard: VDE 0435 T303; IEC 0801 part 1-4; VDE 0160; IEC 255-4; BS142; VDE 0871 Temperature range at storage and operation: - 25 C to + 70 C Constant climate class F acc. DIN 40040 and DIN IEC 68, part 2-3: more than 56 days at 40 C and 95 % relative humidity DOK-TD-XE2 Rev.A 13

Woodward Manual XE2 GB High voltage test acc. to VDE 0435, part 303 Voltage test: 2.5 kv (eff.) / 50 Hz; 1 min Surge voltage test: 5 kv; 1.2/50 µs, 0.5 J High frequency test: 2.5 kv / 1 MHz Electrostatic discharge (ESD) acc. to IEC 0801, part 2: Radiated electromagnetic field test acc. to IEC 0801, part 3: Electrical fast transient (burst) acc. to IEC 0801, part 4: Radio interference suppression test as per DIN 57871 and VDE 0871: 8 kv 10 V/m 4 kv / 2.5kHz, 15 ms limit value class A Accuracy of the specific rated values: 3 % Repeat accuracy: 2 % Basic time delay accuracy: 0.5 % or 50 ms Temperature effect: 0.05 % per K Mechanical test: Shock: class 1 acc. to DIN IEC 255-21-2 Vibration: class 1 acc. to DIN IEC 255-21-1 Degree of protection Front plate: Weight: Relay case material: Mounting position: IP40 at closed front cover approx. 0.5 kg self-extinguishing any Parameter Setting range Graduation I> 0-15 A (min 0,2 A) continuously variable I< 0-5 A (min 0,2 A) continuously variable IR> 0-125 % (min 10 %) continuously variable ti> 0-5 s / 0-50 s continuously variable ti< 0-5 s / 0-50 s continuously variable Table 5.1: Setting ranges and graduation Technical data subject to change without notice! 14 DOK-TD-XE2 Rev.A

Manual XE2 GB Woodward Setting-list XE2 Project: Woodward job.-no.: Function group: = Location: + Relay code: - Relay functions: Date: Setting of parameters Function Unit Default settings I> Exciter overcurrent A 0.2 I< Exciter undercurrent A 0.2 IR> Ripple component supervision % 10 ti> Time delay for I> s 0 ti< Time delay for I< s 0 Actual settings DIP-switch settings DIP-switch Function Default settings 1 Relay latching I>/IR> OFF 2 3 4 Exciter overcurrent element I> Active 5 Exciter undercurrent element I< Active 6 Ripple component supervision IR> Active 7 Multiplier for ti> x 1 8 Multiplier for ti< x 1 Actual settings DOK-TD-XE2 Rev.A 15

Woodward Woodward Kempen GmbH Krefelder Weg 47 D 47906 Kempen (Germany) Postfach 10 07 55 (P.O.Box) D 47884 Kempen (Germany) Phone: +49 (0) 21 52 145 1 Internet www.woodward.com Sales Phone: +49 (0) 21 52 145 216 or 342 Telefax: +49 (0) 21 52 145 354 e-mail: salesemea_pgd@woodward.com Service Phone: +49 (0) 21 52 145 614 Telefax: +49 (0) 21 52 145 455 e-mail: SupportEMEA_PGD@woodward.com