X6 Access Control. System User Manual

Similar documents
.

Set-up of ZK RFID Pin Pad

Installation Guide. UHF RFID Integrated Machine: U1000E, U1000F, U2000E, U2000F. Version: 1.0 Date:

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

SCR100 User Manual. Version:1.1 Date:Dec 2009

C5S120 Installation and Connection Guide

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

GENERAL QUICK START GUIDE

Fingerprint Access Control F1. User Manual

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Connecting a Cisco Output Module

Installation Instructions (KF-2000)

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Digital Keypad Introduction

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

HSY-S209 EM Metal waterproof access control system User Manual

Installation and User Manual

PL- AC02B6 AZ Access Control User Manual

F11 Installation Guide. Version: 1.0 Date: Jul. 2010

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Two Door Controller GEN-045

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

AS Keypad User Manual

REX F-0-9 Standalone or Access Controller

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

DG-800 Stand-Alone Proximity Reader Instruction Manual

ENGLISH RLC CONTROL UNIT USER MANUAL VT-ENG-RLC-V1 090S413

Fingerprint Door Lock OPERATOR S MANUAL

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Single Door Standalone Access Control User Manual

Fingerprint Door Lock User MANUAL

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Wiring Instructions v3

D45 System. 3.5 Colour handsfree internal unit. Front view

ivms-4200 Access Control Client User Manual UD00895N

FTK5 PROXIMITY KEYPAD

User Manual. Split access control with intelligent secured power supply.

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

RFID/Digital Access Control Keypad

CM-110SK Standalone Keypad Installation Instructions

IP Apartment System Quick Start Guide

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Wiring Instructions v4

Operation manual For NG BIOSINGLE Version 1.1

Connecting a Cisco Input Module

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Revision Date: 02 Mar 2018

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Wiring Instructions. Gatekeeper h4.0. Technical Support.

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

GV-EL124S Electric Strike

DT-AKP 2 WIRE SYSTEM. User Manual. Access keypad panel with scramble keypad DT-ENG-AKP-V1 /

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

iface Series Installation Guide

5.5 AS Layout. GeoVision Technical Handbook 77

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

INTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

DSC programming for the Alexor and Impassa

Waterproof. Keypad/Reader/Controller

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Time Attendance User s Manual

212iL Rev. 1.1

DESSMANN - FINGERPRINT LOCK. User Guide G800FPC TX - with SMS Function

DT1 Series 2.1 SINGLE CHANNEL TALKING DIALLER # N761. INSTALLATION MANUAL 3 rd EDITION.

Peristaltic Cased Tube Pump

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

Non-contact or proximity card access control using the manual

8. Electric Lock Connection

K44 Code lock. Technical manual

Wireless Key fob, Key pad & Receiver Range

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

ONYX FINGERPRINT PASSWORD LOCK MANUAL

Installation Guide & User Manual. FR1300 Version: Date: November, 2014

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

The HAUSSMANN RIRI keypad

Users Manual. Operating and Installation Instructions Buffalo River Black Dimaond. Model:ECSL-0601A Electronic Combination Controller

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

Specifications: Features:

W3-H Waterproof Keypad/Reader/Controller

SK-1011-SQ Digital Access Keypad with 5A Relay Output

WiFi Video Doorbell. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

D1265. Installation Guide. Touchscreen Keypad

ACTsmart2 Product Range Operating and Installation Instructions

A-1300 Biometric Access Control System USER'S MANUAL

Access Control Integration Host User s Manual

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Transcription:

X6 Access Control System User Manual

1.Equipment Installation Wall mount installation (1)Remove the screw on the bottom of device. (2)Take away the back cover. (3)Fix the back cover on the wall according to the mounting paper. (4)Fix the device to the back cover. (5)Fix the screw. 2.Structure and Function Access Control System Function: (1)If a registered user verified, the device will export the signal to unlock the door. (2)Door sensor will detect the on-off state. If the door is unexpected opened or improperly closed, the alarm signal (digital value) will be triggered. (3)If the device being illegally removed, the device will export alarm signal. (4)External exit button is supported; it is convenient to open the door inside. (5)External bell is supported. 1

3.Lock Connection Warning: No operation when power on! (1) The system supports NO LOCK and NC LOCK. For example the NO LOCK (normally open at power on) is connected with NO terminal, and the NC LOCK is connected with NC terminal. (2) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107 diode (equipped in the package) to prevent the self-inductance EMF affect the system, do not reverse the polarities. (I)Share power with the lock: Deviceshare power with the lock: ULOCK=12V, I-ILOCK>1A Andthe lockis near to the device. (II)Does not share power with the lock: Devicedoes notsharepower with thelock: A.ULOCK =12V I-ILOCK 1A; B.ULOCK 12V; C.The lock is far apart fromthe device. I1: I : device output current, ULOCK : lock voltage, ILOCK : lock current. 2

4. Conect with alarm Notice: Voltage output DC 12V for Alarm 5.Connect with Power Input DC 12V, 500mA (50mA standby) Positive is connected with +12V, negative is connected with GND (do not reverse the polarities 3

Instructions Buttons represent: [#] means yes, [* ]means Escape Lights represent: Green means sucess, Red means Failure Number: Password=4 digits, work code<=5 digits Tones: Long buzz means success, short buzz twice means failure, short buzz 4 times means wrong action Notice: make sure you pressed [#] to confirm, [*] exit to initial condition 1. User management 1.1 Administraction Operations For the security the data, admin password is needed to operate the machine. Register the admin's fingerprint Press [*]+[#] Input [1234#] register fingerprint 3 times (green light on and a long buzz) press [*] to exit (green light on and a long buzz) Modify the admin's fingerprint Press [*]+[#] Press admin fingerprint press [8] (green light on and a long buzz) register fingerprint 3 times press [*] to exit (green light on and a long buzz) Lost the admin fingerprint Please contact customer service at: 4006-900-999 1.2 Add/Edit a User Each user can regist 10 fingeprint and 1 card at most Press [*]+[#] ress admin fingerprint press [#] Input a new/ exist work code [#] register fingerprint 3 times (green light on and a long buzz) press [#] contiue to add new users OR press [*] to escape(green light on and a long buzz) Notice: a. New user has to put work code,the machine will defultly edit the present user if the number existed. b. After the first fingeprint registered, same user's other fingerprints can be added, 10 pcs at most c. If there is wrong action or repeat occured suring register fingeprint/ cards, machine's red light will be on along with short buzz 4 times, then green light will be on. Continue to register without exit, no operation limits. 1.3 Register Eight Passwords for Opening the Door The machine support at most 8groups of door password, each password respond to a group (range: 1~8): Press [*]+[#] Press admin fingerprint press [3] Input modified group number (1~8) Put 4 digits password [#] (repeat twice) press [*] to exit Notice: a. When a group of password was changed into 00000, then this group of password was shut down 4 b. When a group of password was changed successfully, you can input next group of number to modify directly.

1.4 User Authentication Fingerprint / Card / Password authentication Connect the power, the machine is on the mode of authentication. Press password [#] / Press fingerprint / Swipe card Authenticat successfully Notice: When use a password, the door can be opened as long as the password is same as one of the 8 groups of passwords. Original 8 groups of password are empty. 1.5 Delete Users Delete a single user Press [*]+[#] Press admin fingerprint press [3] Press [2] Put work number [#] / fingerprint / card press [*] to exit Delete all of the users Press [*]+[#] Press admin fingerprint press [9]+[#] press [*] to exit 2. Acess control management (Default setting is recommened) 2.1 Configure Unlocking Duration (Default 6 seconds) Press [*]+[#] Press admin fingerprint press [4] Input unlock duration (1s~10s) press [*] to exit When the unlock duration is bigger than 10, red light will be on. 2.2 Configure Authentication Mode (FP/PW/RF) Press [*]+[#] Press admin fingerprint press [5] Input authentication mode value [#] press [*] to exit Authentication Mode Value Description: Mode Value Description PW 1 Only Password RF 2 Only Card FP 3 Only fingerprint FP/PW/RF 4 Fingerprint or password or card RF& PW 5 Card then password FP & PW 6 Fingeprint them password 2.3 Configure Alarm Alarm Switch (Default ON) The switch is the master switch of the machine, only when it's on, can the alarm incorrectly, tamper alarm and magnet alarm be working properly. The alarm will be shut dowm when it's off. Press [*]+[#] Press admin fingerprint press [0]+ [1] Configure main switch [#] (0: ON, 1:OFF) press [*] to exit Tamper Alarm Configure (Default ON) Only when this function is on, the machine can be alarmed during tampering. Press [*]+[#] Press admin fingerprint press [7] Configure tamper alarm switch [#] (0: ON, 1:OFF) press [*] to exit