Druck DPI 620 advanced modular calibrator

Similar documents
GE Infrastructure Sensing. Druck DPI 832. Electrical loop calibrator User manual - K393

Druck DPI 620. advanced modular calibrator. Advanced Test Equipment Rentals ATEC (2832) GE Sensing & Inspection Technologies

GE Industrial Sensing. Druck DPI 104. Digital pressure indicator User manual - K394

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual.

GE Measurement & Control. Druck DPI 620 Genii Advanced Modular Calibrator K0541

GE Digital Solutions. Druck DPI620 Genii Intrinsically Safe Calibrator and Communicator Series. User Manual 116M5464

DPI 620 Genii Advanced Modular Calibrator and HART / Foundation Fieldbus Communicator

DPI 620 Series Advanced Modular Calibration and HART Communication System

Mini Digital Multimeter

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

ETHOS Auto Ranging Digital Multimeter

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Mini Digital Multimeter

Autoranging True RMS Multimeter User Manual

OPERATING INSTRUCTION

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

User Guide True RMS Multimeter Extech EX205T

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

EVO-TM2A EVO-TM2B Touch Screen Monitor

POCKET MULTIMETER Model No: MM18

Mini Digital Multimeter Model MN15. User's Guide

RTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version

Mini Digital Multimeter

MCX II. Druck Portable Documenting Calibrator. GE Sensing. Features. Applications

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Autoranging Mini Multimeter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

7032 Digital-Analog Multimeter

2 in 1 LAN Tester and Multimeter Model:

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

C-RED 2 Quick Start Manual. C-RED 2 Quick Start_

RS Stock No Instruction Manual RS Input Data Logging Thermometer

GE Measurement & Control. Calibration and Maintenance Solutions for the Power Sector

Operating Instructions

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Operating Instructions

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Model A Mini AC/DC Clamp Meter. User's Guide

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

PanelView Plus/VersaView CE Terminals and Display Modules

ENGLISH. User manual.

User s Guide. 600A AC Clamp Meter. Model 38387

Stonex Europe S.R.L. S3 Series Quick Start

User's Guide. Digital Multimeter. Model MN42

EARTH RESISTANCE & RESISTIVITY TESTER

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

DC 100 A Current Probe

Druck DPI bar g. GE Infrastructure Sensing. Pressure Indicator User manual - K344

Do not attempt to service the unit yourself. Seek assistance from a qualified professional.

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

User's Guide. Phase Sequence and Motor Rotation Tester Model

Earth Resistance and Resistivity Tester

W Warning To avoid electrical shock, remove test leads and any input signals from the Model 707 Loop Calibrator before opening the case.

Quick Start Guide and Health and Safety Information

Bluetooth Speaker Instruction Manual

Digital Multimeter User's Manual

User's Guide. MiniTec TM Series Model MN25 MultiMeter

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

midi LOGGER 220 GL220-UM-251

Thank you for your purchase USER MANUAL

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

Model R5010. TRMS Digital Multimeter. Instruction Manual

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

1-36V, 0-3A DC Power Supply

MC1000 Multi-Function Calibrator

AD-400. CD Player with USB/SD and FM Tuner. Item ref: UK User Manual

9040/9040UK. Users Manual. Phase Rotation Indicator

Always there to help you. Register your product and get support at DS3480. Question? Contact Philips.

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

DC 100 A Current Probe

SLA Battery Capacity Analyzer

AutoRanging Digital MultiMeter

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

PicoVNA. USB vector network analyzer. Quick Start Guide

E8431 First Edition Model: T00CP

True RMS Multimeter with IR Thermometer

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

USER MANUAL. True RMS Multimeter. Extech EX430A

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

testo 176 Data loggers

Version 1.0 March 2014 OLC 10.1

B63/ NS MS. EtherNet/IP LINK

50 Amp AC/DC Current Probe PA-655 INSTRUCTION MANUAL 安培交流 / 直流電流探測鉗. DC 500KHz. 5mA 50A.

D Issue A. Instruction Manual. Active Strain Gauge

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

V /06/ Velleman nv

2020 System Calibrator

SX90 Process Controller

PicoScope 9000 Series PC Sampling Oscilloscopes. Quick Start Guide

ENVIRONMENTAL PROTECTION

Platinum RTD Thermometer MODEL NO

SolConeX extra-low voltage flange socket

Transcription:

GE Sensing & Inspection Technologies A1.1 DPI 620: Channel 1 (CH1) Druck DPI 620 advanced modular calibrator safety and quick reference guide - K0454 Measure (M) / Source (S) / Power (P) a ±30 V (M) b 0 to 12 V (S) ±2000 mv (M) Figure C1 c 0 to 2000 mv (S) Note: = See figure or d 0 to 4000 Ω (M/S) table. e 0 to 50 khz (M/S) f Switch (M) g ±55 ma (M) Figure C2 h 0 to 24 ma (S) i 11 RTDs (M/S) Figure C3 (2, 3, 4-wire) j 12 TCs (M/S) Figure C4 k ±300 Vac: AC probe Figure C5 (Part: IO620-AC) A1.2 DPI 620: Channel 2 (CH2) l ±30 V (M) m ±2000 mv (M) n ±55 ma (M) o 0 to 24 ma (S) p 24 V loop (P) q Switch (M) Figure D1 A1.3 DPI 620 + MC 620 + PM 620 Pressure* (M) Figure E1 Gauge: 25 mbar to 200 bar (0.36 to 3000 psi) Absolute: 350 mbar to 1000 bar (5 to 15000 psi) Note: Maximum pneumatic pressure: 500 bar (7250 psi) * Caution: To prevent damage to the PM 620 module, only use it within the specified pressure limit on the label. 2008 General Electric Company. All rights reserved. Trademarks All product names are trademarks of their respective companies.

A2.1 DPI 620 A2.2 DPI 620 2 3 4 a 9 b C1 DPI 620: CH1 C2 DPI 620: CH1 V, mv, Ω, Hz, A1.1 ( a, b, c, d, e, f ) ma A1.1 ( g, h ) c d 10 e f 1 A2.2 5 6 11 C3 DPI 620: CH1 C4 DPI 620: CH1 A1.1 ( i ) A1.1 ( j ) 7 12 8 A3 DPI 620 B1 MC 620 + PM 620 1 a b 1 1 2 2 5 a C5 DPI 620: CH1 E1 DPI 620 + MC 620 + PM 620 A1.1 ( k ) P1 P2 A1.3 C 4 2 3 3 4 B2 4 a DPI 620 + MC 620 + PM 620 D1 DPI 620: CH2 V, mv, ma, 24 Vo, A1.2 ( l, m, n, o, p, q ) 3 1 b 2 K0454 Issue 1

Quick Reference WARNING: Before you use this instrument, read and understand the Safety section. It is dangerous to ignore the specified warnings. Start operations (S1 to S4) S1: Install the battery. Refer to Section 5. S2: Power on/off sequence ON ➀ First display Normal output OFF ➀ Press and hold S3: Example change of function (Voltage to Current) Task Settings Press Channel Settings 3 4 1 2 TAP Select Function Channel Settings Task Settings 5 6 7 8 [EN] English - K0454 Issue 1 Quick Reference 1

S4: Touch-screen operations (maximise, minimise, set voltage) Maximise Minimise Set voltage 3 * 1 2 4 * TAP Menu sequence 1 * Alternative options for step ➀ TAP Task* Settings CH1 CH2 Channel Settings Function Select Function None Current Units Voltage Utility Caption * A channel can only have one function at a time. 2 Quick Reference K0454 Issue 1 - [EN] English

1 Overview The advanced modular calibrator (AMC) is part of a set of hand-held modules that you can quickly put together to include a wide range of calibrator functions. Advanced modular calibrator, DPI 620: This is a battery-powered instrument for electrical measure and source operations and HART communications; see table A1(front DPI 620 cover). It also supplies the power and user interface functions for all the add-on modules. You can use the touch-screen to display up to six different parameters. Pressure module carrier, MC 620: Optional item. This attaches to the DPI 620 calibrator to make a fully integrated pressure indicator instrument. To measure and display pneumatic or hydraulic pressures, you can have up to two MC 620 interchangeable pressure transducers at a time. PM 620 PV 62x Pressure modules, PM 620: Optional item. These modules attach to the pressure module carrier (MC 620) or to a pressure station (PV 62x) to give the DPI 620 calibrator the necessary pressure measurement functionality. They are fully interchangeable plug and play modules with no initial set-up or user calibration. Pressure stations, PV 62x: Optional item. To make a fully integrated pressure calibrator, you can attach the DPI 620 calibrator to one of the three pressure stations. Refer to user manual - K0457. 2 Standard equipment These items are part of the standard equipment with the DPI 620 calibrator: DC power supply/battery charger unit Li-Polymer battery Set of six electrical test leads Safety and quick reference guide CD with the user manual [EN] English - K0454 Issue 1 Overview/Standard equipment 3

3 Safety Before you use the instrument, make sure that you read and understand all the related data. This includes: the applicable local safety procedures, the user manual (K0449), and the instructions for the accessories/options/equipment you are using it with. General warnings Electrical warnings Pressure warnings WARNING It is dangerous to ignore the specified limits for the instrument or to use the instrument when it is not in its normal condition. Use the applicable protection and obey all safety precautions. Do not use the instrument in locations with explosive gas, vapour or dust. There is a risk of an explosion. To prevent electrical shocks or damage to the instrument, do not connect more than 30V between the terminals, or between the terminals and the ground (earth). To prevent electrical shocks, use only the GE specified AC probe (Part: IO620-AC) to measure AC voltages (maximum: 300 Vac). This instrument uses a Lithium-Polymer (Li-Polymer) battery pack. To prevent an explosion or fire, do not short circuit, do not disassemble, keep it safe from damage. For operating conditions, see Table 1. To prevent an explosion or fire, use only the GE specified battery, power supply and battery charger. To prevent battery leakage or heat generation, only use the battery charger and power supply in the temperature range 0 to 40 C (32 to 104 F). For operating conditions, see Table 1. Some liquid and gas mixtures are dangerous. This includes mixtures that occur because of contamination. Make sure that the equipment is safe to use with the necessary media. To prevent a dangerous release of pressure, isolate and bleed the system before you disconnect a pressure connection. Continued 4 Safety K0454 Issue 1 - [EN] English

To prevent a dangerous release of pressure, make sure that all the related pipes, hoses and equipment have the correct pressure rating, are safe to use and are correctly attached. Cautions Marks and symbols on the instrument To prevent damage to the display, do not use sharp objects on the touch-screen. To prevent damage to the PM 620 module, only use it within the specified pressure limit on the label. Before you start an operation or procedure in this publication, make sure that you have the necessary skills (if necessary, with qualifications from an approved training establishment). Follow good engineering practice at all times. Complies with European Union directives Warning - refer to the manual Read the manual USB ports: Type A; Mini-type B connector Ground (Earth) ON/OFF Do not dispose of this product as household waste. Refer to Maintenance (Section 5.5). More marks and symbols are specified in the user manual (K0449 - Druck DPI 620 Advanced modular calibrator) 4 Parts Refer to the figures on the front cover (A2, B1). 4.1 Key to figure A2 (DPI 620 calibrator) A2 1. On or off button. Refer to Quick Reference. 2. CH1 Channel 1 connectors for: voltage (V); frequency (Hz); resistance (Ω); resistance temperature detectors (RTD): 3W, 4W = 3-wire, 4-wire RTD input; switch operation; current (ma+, ma-): COM = Common connector You can also use the GE specified AC probe (Part: IO620-AC) to measure AC voltages (maximum: 300 Vac). 3. TC Channel 1 connectors for thermocouples. 4. CH2 Isolated channel 2 connectors for: voltage (V); current (ma+, ma-); 24V loop power supply (24Vo); switch operation [EN] English - K0454 Issue 1 Parts 5

A2 5. USB type A connector for connections to external peripherals (USB flash memory or optional external modules). 6. USB mini-type B connector for communication with a computer. 7. +5V DC power input socket. This supply also charges the battery. 8. Sealed speaker unit. 9. Liquid crystal display (LCD): Colour display with touch-screen. To make a selection, lightly tap on the applicable display area. a. Battery indicator b. Date and time 10. CH1: Window for the channel 1 settings and values. c. Measure or source indication d. Function e. Full scale (FS) range f. Function units 11. Other windows: The number of windows you see on the display is set by the number of task selections and external modules you are working with (maximum: 6). 12. Tap this button to set up the Task, set up the instrument (Configure) and to access Help (?). Refer to Quick Reference. Tap this button to maximise each of the available windows in sequence. Refer to Quick Reference. Pause (II) or Play ( ): Tap (II) to hold (freeze) all the data on the display. To release the display and continue, tap ( ). 4.2 Key to figure B1 (MC 620 module carrier/pm 620 module) - Optional item B1 1. Pressure connection (G1/8 or 1/8NPT) to attach external pressure equipment. 2. Pressure and electrical connections for a pressure module (PM 620). These are self-seal pressure connections. 3. Two screws to attach the calibrator (DPI 620). 4. Electrical connections for the calibrator (DPI 620). 5. Pressure module (PM 620) with a pressure connection, reference port (a) and a label. The label includes: Pressure range. Example: 20 bar g (g: gauge; a: absolute); serial number (S/N); manufacturer: name, address, website 6 Parts K0454 Issue 1 - [EN] English

5 Installation Before you start: Read and understand the Safety section. Do not use damaged equipment. Note: Use only original parts supplied by the manufacturer. 5.1 AMC battery See figure A3 (front cover). A3 Step Procedure 1. When the power is off, loosen the five screws (a) and remove the cover (b). If necessary, turn the instrument over and let the discharged battery drop into your hand. 2. Install the new battery correctly until it is flat in the compartment. 3. Re-attach the cover. 5.2 Indicator assembly Optional item (MC 620/PM 620). See figure B2 (front cover). B2 Step Procedure 1. Align the two slots (a) on the calibrator with the two posts (b) on the module carrier. 2. When the posts are fully engaged in the slots, tighten the two screws until they are hand tight. 3. Attach one or two PM 620 modules with the correct range and type. 4. Tighten each one until it is hand tight only. 5.3 Electrical connections 5.4 External pressure connections See figure C1 to C5, and D1 (front cover). See figure B1/E1 (front cover). Use an applicable method to seal the external pressure connections, and then tighten to the applicable torque. Maximum torque: 1/8 NPT: 35 Nm (26 lbf.ft) G1/8: 25 Nm (18.4 lbf.ft) [EN] English - K0454 Issue 1 Installation 7

5.5 Maintenance Clean the case with a moist, lint-free cloth and a weak detergent. Do not use solvents or abrasive materials. Return the instrument to the manufacturer or an approved service agent for all repairs. Refer to the user manual. Do not dispose of this product as household waste. Use an approved organisation that collects and/or recycles waste electrical and electronic equipment. For more information, contact one of these: our customer service department: (Contact us at www.gesensing.com) your local government office. 6 Specification Display Operating temperature Storage temperature Ingress Protection Humidity Shock/Vibration Table 1: General specification LCD: Colour display with touch-screen -10 to 50 C (14 to 122 F) -20 to 70 C (-4 to 158 F) IP65 (DPI 620 calibrator only) 0 to 90% relative humidity (RH) non-condensing Def Stan 66-31, 8.4 cat III EMC Electromagnetic compatibility: BS EN 61326-1:2006 Electrical safety Electrical - BS EN 61010:2001 Pressure safety Approved Pressure Equipment Directive - Class: Sound Engineering Practice (SEP) CE Marked Battery power Lithium-Polymer battery (GE Part number: 191-356) Capacity: 5040 mah (minimum), 5280 mah (typical); Nominal voltage: 3.7 V. Charge temperature: 0 to 40 C (32 to 104 F) Note: When the instrument senses the temperature is outside this range, it stops charging. Discharge temperature: -10 to 50 C (14 to 122 F). Charge/discharge cycles: > 500 > 70% capacity 8 Maintenance/Specification K0454 Issue 1 - [EN] English

Customer service Visit our web site: www.gesensing.com