Installation User Manual

Similar documents
Installation User Manual

Installation User Manual

Installation User Manual

Installation User Manual

EPON OLT PTF3004. Description: Features:

FD series EPON ONU

ONU-1GE-W series is SOFTEL s for broadband access market based on the introduction of EPON

8-port GPON OLT P Compact high performance GPON OLT for medium and small operator

Wi-Fi series meet n/b/g technical standards Up to 20KM transmission Distance Support data encryption, group broadcasting, port Vlan separation,

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

EOC Master (Headed Equipment) User Manual

FD111HZ-EPON User Manual. Version:V1.1

H3C SecPath M9000-S NSQM2MPUD0 main processing unit

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011

CVH Slot Media Converter Chassis Quick Installation Guide

Chapter1: Overview. 1.1 Product Description. 1.2Application Chart. Model:-FS-2LAN+1POTS+WiFi Dual Mode. HGU User Manual V1.0

AN B Optical Line Terminal Equipment. Hardware Description. Version A. Code: MN FiberHome Telecommunication Technologies Co., Ltd.

FSM-510G Series Ethernet Management Switch Quick Start Guide

Gigabit EPON ONU (ONU-241) User s Guide

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

BDCOM GP3600 series High-density Rack-mounted GPON OLT

ONT-1GE-W. Brief Views

EPON ONU User Handbook V1.1

Hardware Description

CBS-GEPON-P CONNECTION TO THE MODERN WORLD. CBS-GEPON-P (Giga Ethernet Passive Optical Network) PIZZA BOX

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

IES7110-2GS Series. Managed Industrial Ethernet Switch. User manual. Summarize. Panel layout. Packing list. Feature

ISCOM6820-GP GPON OLT

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X

Industrial Ethernet switch ⅹ 1 Documentation and software CD ⅹ 1 User manual ⅹ 1 DIN-Rail mounting kit ⅹ 1 Warranty card ⅹ 1

Quick Start Guide. Physical Description. The Port Status LEDs

OP-GONT 91001W. Overview: 1Port Gigabit GPON ONT

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Support IEEE802.3ah EPON Maximum transmission distance is 20Km at 1:32 split ratio

IEC /IEEE 1613 Lite L3 Hardened Managed 24-port Gigabit SFP. 10GbE Connectivity Four 10G SFP+ for connecting the switch to the core network

Product Overview. Switch Models CHAPTER

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

GV-POE2401-V2 24-Port 802.3at Web Management PoE

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

PHB-200M PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub

8~14-Port Managed Ethernet Switch

SWH-3112 Series 12-port L2+ Managed Gigabit Fiber Switch User s Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

PHB-200M/PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

SW24MGSFP 10/100/1000 Mbps + 2 Gb SFP Web Smart Ethernet Switch User Manual Version 1.0 (January 2011)

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

IPS-3110 Managed Industrial PoE Gigabit Ethernet Switch

Industrial 3-Port Fast Ethernet Media Converter Switches

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

INDUSTRIAL POE SWITCH

Installing the Cisco 2524 and Cisco 2525 Routers

KFC-200. Installation Guide

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X FE/GbE Media Converter Concentrator

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

ECS4620 Series 28/52-Port Layer 3 Stackable GE Switch Installation Guide

C-Data GEPON OLT FD2000S

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Industrial Switches Industrial Switches

Overview. Features CHAPTER

Installing the Cisco AS5400XM Universal Gateway

PIX 520. PIX 520 Product Overview CHAPTER

Summit Virtual Chassis Design and Installation Guide

Spotlight Versatile Connectivity Modularized Ethernet Switch of 24-port 10/100BASE-TX/FX/BX and 4-port Gigabit-TX/SX/LX/BX/SFP

Hardened Web-Smart High Power PoE Ethernet Switch

Gigabit Ethernet Switch With 10G Uplinks. Hardware Manual MS400860M

IES1024 series. Industrial Ethernet switch. User manual

720Gbps Switching Capacity

Save installation time and money with PoE

Hardened PoE Ethernet Switch

2-Port GEPON Managed OLT EPL-2220

IEC /IEEE1613 Managed 24-port 10/100BASE and 4-port Gigabit Ethernet Switch with SFP options

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

Product Overview. Features CHAPTER

SW-UNM-24FE2GC-24POE 24 Fast Ethernet Ports PoE + 2 Giga Combo User Manual Ver 1.1

Managed Ethernet Switches

10/100M Ethernet Media Converter.

Please check the packaging and accessories by your first using. Industrial Ethernet switch ⅹ 1 User manual ⅹ 1

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Installing the ASA 5550

Industrial Ethernet Switch

Quick Start Guide Elinx ESW500 Series. Managed Din Rail Ethernet Switch

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

IES615-2D Series. Industrial Ethernet Switch. User Manual. Summarize. Panel layout. Packing list. Features. Shenzhen 3onedata Technology Co., Ltd.

FD404GW series 4GE+ 2POTS + CATV+ Wi-Fi Single Fiber EPON ONU Brief Views ONU FD404GW (4GE+2POTS+RF+Wi-Fi) series is a FTTH bandwidth access equipment

PON Product Datasheet U9016B

D-Link Switch User Manual. Table of Contents

SWITCH, 24 POE PORTS ART. IPSWP240A

Installing Power Modules

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

PT-7728/7828 Quick Installation Guide

Transcription:

EPON OLT EPON Optical Line Terminal Equipment Installation User Manual V.1.3

Contents 1 PRODUCT INTRODUCTION... 2 1.1 BRIEF INTRODUCTION... 2 1.2 FUNCTIONAL FEATURES... 2 1.3 APPEARANCE AND INTERFACE... 3 2 PRE-INSTALLATION PREPARATION... 5 2.1 POWER REQUIREMENT... 5 2.2 EQUIPMENT GROUND... 5 2.3 ROOM DESIGN REQUIREMENTS... 5 3. HARDWARE INSTALLATION... 5 3.1 OPEN PACKAGE AND CHECKOUT... 5 3.2 PRE-INSTALLATION PREPARATION... 6 3.3 OLT INSTALLATION... 6 3.3.1 Plane stack installation... 6 3.3.2 Rack Installation... 7 3.4 PORT AND CONNECTION... 7 3.4.1 Uplink Port... 8 3.4.2 PON Port Connection... 9 3.4.3 Ground Cable Connection... 9 3.4.4 Management Port Connection... 10 3.4.5 Power Supply... 11 3.5 OLT WORKING STATUS CHECKOUT... 12 3.5.1 Check out power supply... 12 3.5.2 Check out OLT s working status... 13 3.5.3 Check out ONU Registration... 13 3.5.4 Network Connection Checkout... 13 3.5.5 Network Management Checkout... 13 5 DEFAULT CONFIGURATION... 14 5.1 NETWORK PARAMETER CONFIGURATION... 14 5.2 CONSOLE PARAMETER CONFIGURATION... 14 5.3DEFAULT USERNAME AND PASSWORD... 14 6 APPENDIX : OLT SPECIFICATION... 15 8 ENDING... ERROR! BOOKMARK NOT DEFINED. 1

1 Product Introduction 1.1 Brief Introduction The Pizza-Box OLT series products of 1U high 19 inch rack mount. The features of the OLT are small, convenient, flexible, easy to deploy, high performance. It is appropriate to deploy in an compact room environment. The OLT can use for Triple-Play, CPN, IP Camera, Enterprise LAN and IOT applications. It is a high cost performance products. 8 PON OLT in EPON system 1.2 Functional Features Support 8 PON ports at most. Support 512 ONU (by 1:64 splitting ratio within 10km). provides 8GE(copper) and 8SFP slots Combo interface for uplink. Layer-two link rate switch. MAC Address Capacity: 16K VLAN supported number:4096 ONU auto-detection and registration 2

Dynamic bandwidth allocation. Support online upgrading and ONU batch upgrade. Management Interface: Support in-band and out-band management. Management Mode: CLI, TELNET,EMS Reliability: dual power redundant power supply 1.3 Appearance and Interface The 8 PON OLT 1U high Pizza-Box, can be mounted into the standard 19 rack. Demission of machine frame: 442 mm (Length) x 315 mm (Width) x 44 mm (Height). As shown below: Front View of 8 PON OLT 8 EPON SFP ports, 8GE(copper) and 8SFP slots Combo interface for uplink, 1 console port and 1 GE network management port. For details, see the following table. Item Specification Uplink Port Copper 10/100/1000M auto-negotiable,rj45, 8pcs SFP 8 SFP slots(combo) QTY 8 PON Port Physical Interface SFP Slots Connector Type 1000BASE-PX20 CONSOLE port RJ45 connectors for local configuration Management Ports AUX port (auxiliary port) ---RJ-45 connectors for Remote configuration Reset Button For reset the OLT Please refer to Table about LED and button on the front panel of OLT. Type Identification Status Indication Power supply PWR n Green, Always ON Normal Power supply 3

indicator ( n = 1/2 ) OFF Power supply is unconnected or breaks down System SYS Flash per second System normally operate status Out-band management AUX Flash There is communication data at AUX port port Green, Always MGNT port is connected ON OFF MGNT port isn't connected PON port P n Flash There is communication data indicator ( n=1/2/3/4/5/6/7/8) at EPON port(n) Green, Always ON There are ONU registed on OLT port(n) and the optical Uplink port GE n indicator ( n=1/2/3/4/5/6/7/8) fiber link is normal. OFF NO ONU link with the OLT port(n) Flash Green, Always ON There is the communication data at the uplink port(n) The uplink port(n) is connected OFF The uplink port(n) isn't connected Alarm ALARM1 Reserved ALARM2 Reserved Back View of 8 PON OLT Item Grounding Terminal Power supply slot Specification One, it's in the left of the front panel and is used to grounding for machine frame There are two slots for power supply. You can chose AC or DC power supply 4

2 Pre-Installation Preparation 2.1 Power Requirement The input voltage must be stable, no EMI noise and distortion. When use DC power supply, the input voltage is -48VDC, the allowed range is -36 ~ -72 VDC. When use AC power supply, the input voltage is 110/220VAC, the allowed range is 90 ~ 264VAC. Note: Follow all security specification and the rule about the electricity in the locality or the building. All power supply must be legal. 2.2 Equipment Ground The grounding body must be configured in the machine room, the grounding resistance value is less than 1Ω. It can be realize by layout the anti-static copper nose. 2.3 Room Design Requirements The environment of the equipment operation has very big effect on its long-term reliable operation.room design requests to up to the following standards: The device allows room temperature is 0 C ~ 40 C. To ensure that equipment works in the normal temperature environment (25 C or so), should try to make the equipment away from the main heat source (such as power supply, etc.), if the environment temperature is higher than 40 C, should try to improve the ventilated condition of the room, such as install fan in the frame or air conditioning in the room. The ventilation pipe in the room should be swept clean and ventilated, etc.; There must be the good cable wiring and go line space in the room. Cable and optical cable wiring (including fiber splicing work) are already in place. The related humidity 10%~95%, No condensation, no frost; The dust particles density with more than 5μm in diameter 3.0*104/m3 ; Dust particles is a non-conductive, the non-magnetic and the non-corrosive; 3. Hardware Installation 3.1 Open package and checkout According to the packing list or supply contract, check and verify the goods, if any 5

component is loss, wrong or damaged, please contact with your customer manager. The list includes the following content normally: 1 OLT Machine(1 Pcs) SFP modules are ordered according to user requirement AC power line or DC power line according to user requirement 3.2 Pre-installation Preparation Verify the following working environment and installation requirements 1 Power Supply Requirement: - DC power supply: 48V DC, the allowed range:-36vdc~ -72 VDC - AC power supply: 110/220V AC, the allowed range: 90 ~ 264VAC 2 The equipment should be equipped in the dry, cool place, at least have 10 centimeters at both sides for the ventilation space. 3 Avoid the direct light, far away from the heat source or the place with the stronger electromagnetic interference 4 If want to install OLT inside the rack, ensure that have the necessary mounting screws and nuts and necessary tools. 5 Check the required cable and connectors for installation 6 In the system management, need connect the following equipment with OLT: - A management platform, such as PC - RJ45/DB9 RS232 Console line 3.3 OLT Installation OLT can be put in the bigger horizontal surface or within the standard EIA 19 " rack. 3.3.1 Plane stack installation Step I: Pre-Installation Validation Ensure the worktable is strong enough to support the weight of the device and cables. Ensure no obstacles on the worktable and the surroundings affecting the installation of the device exist. Prepare the OLT device to be installed and move the device to the place where is near the work table and facilitates the handling. Step II: Lift the OLT device and slowly move to the front of the worktable. Step III: Move the OLT device to the location slightly higher than the worktable and then place the OLT device to the specified location on the worktable. 6

3.3.2 Rack Installation OLT equipment can be installed inside 19 rack which is compliance with ETSI standard. OLT rack diagram as shown in below. The installation process is as follows: Step I: Pre-Installation Validation Ensure the cabinet is fixed and the installation location of the OLT device in the cabinet is well arranged, and no obstacles inside the cabinet and the surroundings affecting the installation of the device exist. Prepare the OLT device to be installed and move the device to the place where is near the cabinet and facilitates the handling. Step II: Lift the OLT device and slowly move the device to the front of the cabinet. Step III: Lift the OLT device to the location slightly higher than the tray or sideway of the cabinet, place the OLT device to the tray or sideway of the cabinet and then push it to the cabinet. Step IV. Use screws to fix the suspension loops of the cabinet to the square holes of the 19-inch cabinet column and to fix the OLT device to the cabinet. 3.4 Port and Connection The chapter describes the port and power supply connection situation in OLT system, mainly include the following parts: Uplink Port PON Port Connection Ground Cable Connection Management Port Connection Please carefully read the following introduction before connecting each port of OLT: 7

3.4.1 Uplink Port 3.4.1.1 Port Explanation OLT offers eight GE (Copper) and eight GE SFP slot Combo interface for uplink. To use the optical port, you need insert the SFP module to the port and then connect other Ethernet devices through the optical fiber cable. If the port is inserted with the SFP module, the corresponding electrical port cannot be used. To use the electrical port, you can connect the electric port and other Ethernet devices with the direct-through or cross cable through the UTP port of the 8 PON OLT. In this case, the corresponding optical port cannot be used. SFP module can be the optical module or the electrical module, and follow standards below: 1000Base-LX (Long wave length) 1000Base-SX (Short wave length) 10/100/1000Base-T (Electrical port) When use the single mode optical fiber, the maximum transmission distance can be up to 10-40km; when use the multimode fiber, the maximum transmission distance is less than 500 meters. Gigabit Ethernet uplink port supports the duplex mode and flow control autonegotiation. But need note that the maximum length of the optical fiber is related with work mode of the optical fiber: Maximum length of 1000Base-LX fiber is depend on duplex mode Maximum length of 1000Base-SX fiber is the same in both full duplex and halfduplex mode 3.4.1.2 Port Connection There are two kinds of uplink network connection: Cable with RJ45 connectors at both sides Cable with LC connector at both sides Decide the port type of OLT according to the port type of the uplink device (Switch or Route) 3.4.1.3 Method of making cable If you use SFP optical module, cable specification: the optical cable with LC connector at both sides. If you use GE copper interface, cable specification: Category 5 cable or Category5 super cable with RJ45 connector at both sides45 8

The below the reference for making STP (Shielded Twisted-Pair) cable with RJ45connector at both sides 3.4.2 PON Port Connection 8 PON OLT support eight EPON SFP slots, every SFP EPON slots can mount a EPON SFP module and provides one PON port. Caution: When insert into optical cable, please confirm the connector is inserted into the correct position, thus guarantee the good contract. SFP PON slots installs standard 1000BASE-PX20 OLT SFP.The OLT SFP interface is SC/PC. Please use the patch cord with SC/PC connector to connect between the OLT and the ODN networking. 3.4.3 Ground Cable Connection Ensure the safety and reliable working of OLT. 8 PON OLT should be connected with the ground if necessary. Grounding screws are located in the rear panel. While connecting, you should use screwdriver to loosen the grounding screw first, then connect the ground cable, finally tighten the screws. 9

3.4.4 Management Port Connection OLT 8 PON OLT equipment provides console interface (marked as CONSOLE RJ45 type port) and out-band management internet access (marked as AUX RJ45 type port). Console access is really only required when initially configuring a device, or if remote access fails. Console access requires: Console cable: RJ-45-to-DB-9 console cable Terminal emulation software: HyperTerminal The cable is connected between the serial port of the host and the console port on the device. Most computers and notebooks no longer include built-in serial ports. If the host does not have a serial port, the USB port can be used to establish a console connection. A special USB-to-RS-232 compatible serial port adapter is required when using the USB port. Port on Computer Serial Port USB Type-A Port Cable Required RJ-45 to DB-9 Console Cable USB to RS-232 compatible serial port adapter ( Adapter may require a software driver ) RJ-45 to DB-9 Console Cable Port on OLT RJ-45 Console Port When starting the out-band management, please use straight and cross Ethernet cable, connecting MANAGE out-band management interface to network or managed PC. 10

3.4.5 Power Supply 3.4.5.1 Connecting the AC Power Cable The two AC power supply units in the 8 PON OLT allow for 1 + 1 power redundancy. If one power supply unit fails, then the system will continue to operate using the remaining power supply unit. Additionally, to ensure true AC line input redundancy for the OLT, you should connect each AC power cable to a different AC power source. You can also connect an uninterruptible power supply (UPS) between each AC power source and the OLT to increase the availability of the OLT. 1. Get the supplied AC power cords from the OLT's shipment kit. 2. Connect one end of each AC power cord into the AC power inlet connectors located at the rear of the OLT. 3. Connect the other ends of the power cords into AC wall outlets. Connect each AC power cord to a different AC power source if you want AC line input power redundancy. 3.4.5.2 Connecting the DC Input Power Cable 1. Identify the parts that you will use to assemble the DC input power cable The following DC connection cable is required to assemble one or more DC power input cables. These cables connect the -48V DC input source(s) to the power supply units. 2. Turn off power from the DC power source through the circuit breakers. Caution - Do not proceed with these instructions until you have turned off the power from the DC power source through the circuit breakers. 3. Get a DC input plug from the ship kit. 4. Locate the four wires coming from the DC power source that will be used in the connection to your unit:: -48V (negative terminal) (two wires) -48V Return (positive terminal) (two wires) 5. Strip 5/16 inches (8 mm) of insulation from each of the wires coming from the DC power source. Do not strip more than 5/16 inches (8 mm) from each wire. Doing so leaves uninsulated 11

wire exposed from the DC connector after the assembly is complete. 6. Feed the exposed section of the appropriate wire into the rectangular plug hole in the DC input plug.shows which wires should be inserted into each hole in the DC input plug. 7. Repeat Step 5 and Step 7 for the other two wires to complete the assembly of the DC input power cable. 8. Connect the DC input power cables to the DC connectors 3.5 OLT working status checkout 3.5.1 Check out power supply Before you connect the power supply, double check the power supply if it is accord with the power supply requirements, If each module and card are installed correctly, If the equipment is in reliable grounding or not. After checking everything is OK, you can turn on the power supply sources. 12

3.5.2 Check out OLT s working status Please check if the OLT s working status from following aspects: Check the power LED. The power LED will be on. The SYS LED will flash per second If the uplink equipment is connected to the uplink port, the relevant connection LED is on. 3.5.3 Check out ONU Registration In default situation, there is no need any configuration after you turn on the equipment. ONU equipment can be registered after connected with the PON port of OLT 8 PON OLT. Before starting access the equipment, please use optical power meter to measure the optical power of PON port, and check if it s in equipment specification range. Using one ONU correctly connecting with any PON port of OLT, check if this ONU can be registered to OLT by means of the ONU s LED working status, once the ONU is successfully registered, the Pn LED close to PON port of OLT should be on. 3.5.4 Network Connection Checkout In the case of default configuration, the network of users could communicate with when ONU registers with 8 PON OLT. Connect a PC with an ONU UNI port and check if the network is running well by means of ping LAN (in the same IP address) or by PING package tools. 3.5.5 Network Management Checkout Local Command Line Interface Management: Use the RJ45/DB9 Serial Port cable (in package) to link management PC with 8 PON OLT CONSOLE port. Management computer can access to OLT equipment from Super terminal interface of the PC for configuration.. In Band and out band Management Use PC which has installed EMS network management software to connect in band or out band port of 8 PON OLT. EMS network management can visit 8 PON OLT after adding the olt into EMS interface. The icon of 8 PON OLT shows green, and its PON card is also green. Icon of ONU which register to 8 PON OLT is green under EMS interface as well. 13

You also can telnet the 8 PON OLT by inband and outband. Please refer to relevant CLI user manual if you want to know more about command management, and refer to EMS network management configuration user manual to know more about EMS network management functions and operations 5 Default Configuration 5.1 Network Parameter Configuration Out Band Network Port (uplink port on switch control card) IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Default Gateway: 192.168.1.1 Read community: public Write Community: private In Band Network Port IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Default Gateway: 192.168.1.1 Read community: public Write Community: private 5.2 CONSOLE Parameter Configuration Band Rate: 9600 Data Bit: 8 Parity Check: NO Stop Bit: 1 Flow Control: NO 5.3Default Username and Password Local Command Line Username:admin Password:admin SNMP Access 14

Read Community: public Write Community: private 6 Appendix : OLT Specification Item 8 PON OLT Chassis Rack 1U 19 inch standard box Slots NA QTY 16 Uplink Port Copper 10/100/1000M auto-negotiable,rj45:8pcs PON Port SFP QTY 8 Physical Interface Connector Type Max splitting ratio 1:64 8 SFP slots(combo) SFP Slots 1000BASE-PX20 Management Ports 1*100BASE-TX outband port 1 CONSOLE port Transmission Distance 20KM PON Port Specificatio n (Apply to Pon module) PON port speed Symmetrical 1.25Gbps Wavelength 1490nm TX,1310nm RX Connector SC/PC Fiber Type 9/125μm SMF TX Power +2.5~+7dBm Rx Sensitivity -27dBm Saturtion Optical Powr -6dBm Management Mode SNMP, Telnet, and CLI management mode. Fan Group Detecting Port Status monitoring and configuration management; Layer-2 switch configuration such as Vlan, Trunk,RSTP,IGMP,QOS, etc; Management Function EPON management function: DBA,ONU authorization, ACL,QOS,etc; Online ONU configuration and management User management Alarm management Support port VLan and protocol Vlan Support Vlan tag/untag,vlan transparent transmission; Support 4096 VLAN Layer-two Switch Support 802.3dd trunk RSTP QOS based on port,vid,tos and MAC address 15

EPON Function Dimension Weight Power 220VAC Supply -48DC Power Consumption Operating Working Temperature Environme Storage Temperature nt Relative Humidity IGMP Snooping 802.x flow control Port stability statistic and mornitoring Support port-based rate limitation and bandwidth control; In compliant with IEEE802.3ah Standard Up to 20KM transmission Distance Support data encryption, group broadcasting, port Vlan separation,rstp,etc. Support Dynamic Bandwidth Allocation (DBA) Support ONU auto-discovery/link detection/remote upgrade of software; Support VLAN division and user separation to avoid broadcast storm; Support various LLID configuration and single LLID configuration.different user and different service could provide different QoS by means of different LLID channels. Support power-off alarm function,easy for link problem detection Support broadcasting storm resistance function Support port isolation between different ports Support ACL and SNMP to configure data packet filter flexibly Specialized design for system breakdown prevention to maintain stable system Support dynamic distance calculation on EMS online Support RSTP,IGMP Proxy 442mm(L)*315mm(W)*44mm(H) 4.5kg AC: 90V~240V,47/63Hz DC:-36V~-72V 48W -10~45-40~85 5~90%(non-conditioning) 16

17