Surgelogic Surge Protective Device I-Line Plug-On Unit Series

Similar documents
SURGELOGIC TM. Surge Protective Device Transient Voltage Surge Suppressor (TVSS) XGA, XT, XF, XP Series. Class Schneider Electric Brands

Surgelogic Surge Protective Devices LC, XR, and XW Series

Internal Modular SPDs

I-Line SPDs Square D TM Internally Mounted Surge Protective Devices

Eaton s SPD Series for integration into electrical distribution equipment

BSPD Surge Protective Devices

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning

B. System Design and Performance Requirements

Section 6. Surge Protective Devices (SPDs) Table of Contents. Externally Mounted Surge Protective Devices

Clipper Power System Visor Series

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

THE SURGE PROTECTION SOLUTION

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Powerware TVSS (Transient Voltage Surge Suppression) ZoneMaster, ZoneSentinel, ZoneDefender

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

ZoneMaster Series Surge Protection Devices

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

Always "On" UPS Systems Inc. USER MANUAL

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

Protect your facility from the destructive effects of power surges with a fully

GE Digital Energy. Power Quality

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

1. This section describes the materials and installation requirements for surge protective devices (SPD) for the protection of all AC electrical

SECTION SURGE PROTECTIVE DEVICES

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Liebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

TVSS Series STABILINE Transient Voltage Surge Suppressors

Section 9 TVSS. Contents

TransGuard. Electrical Transient Suppression Filter Systems. Installation, Operation and Maintenance Manual PN ,

Surge & Filter Protection Addressing your industrial power quality needs.

NEMA 1 / IP40 metal housing. Compact design

Specifications, Installation, and Operating Instructions

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

TDX Series. Transient Discriminating TM TVSS

glossary GE Digital Energy Power Quality Surge Protective Devices (SPDs)

Zelio Count - Counters RC87610

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

DTK-WH8PLUS. Premium Whole House Surge Protection General Product Specifications

Instruction Bulletin Boletín de instrucciones Directives d'utilisation , Rev. 02, 03/2016

Surge Protection Devices Ex9UE2

Surge Protection Solutions. Industrial Market Automation Market OEM Market

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

PDI Modular Compact Remote Power Panel

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

Technical Data Sheet Medium Current Power Surge Filters

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS

GUIDE TO VERIFYING SURGE PROTECTIVE DEVICES INSTALLED IN LIGHTNING PROTECTION SYSTEM INSTALLATIONS ARE COMPLIANT WITH UL 96A.

LPI SST Surge Filters

Liebert LM Series. Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

LPI SG + SS480 Spark Gap Surge Filters

Installation Instructions & User Manual

US Catalog March Surge protective devices (SPDs) UL range

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Equipment level protection for AC/DC network cable, data and low voltage applications. Available in din-rail and direct inline installation.

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

OVRH catalog Surge protective devices

TDS Transient Discriminating Surge Diverters

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

Grid to Chip Surge Protection Product Catalog

In the simplest terms, surge protective devices (SPDs) prevent damaging transient voltage surge levels from reaching the devices they protect.

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Instruction Manual IM E Table of Contents

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Surge Protection for Surveillance Systems

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

Surg Sur e P ot r ection

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Installation and Operation Manual

AC and DC Protector Applications

Isobar Surge Suppressors by Tripp-Lite (Most Popular Models)

Office Product. Surge Protection Devices

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps

LPI SG + SST Spark Gap Surge Filter

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Innovative Technology line filters and surge protectors

Qipof!)815*: !+!Gby!)815*61:.5594!+!Q/P/!Cpy!2969!+!Ivoufstwjmmf-!OD!!39181!+!!! xxx/tjofxbwfufdiopmphjft/cj{!

MAJOR VA Power Inverter

Dirty Power... A Guide to Surge Suppression & Filtering. Surge & Signal Protection for Business-Critical Continuity. EmersonNetworkPower.

Surge Protective Devices (SPD)

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

SP SP-T-9

Single Phase Systems-North American PC125/PC420 Series

Transcription:

Surgelogic Surge Protective Device I-Line Plug-On Unit Series Catalog 1310CT0201R5/07 2007 Class 1310 CONTENTS Description Page Product Description.................................................. 2 Application Information................................................ 3 Selection and Specifications............................................ 4 Replacement Parts................................................... 6 Dimensions and Weights.............................................. 7

Description Description I-Line Plug-On Unit with Surgelogic TVSS Surge protective device (SPD) units protect electronic equipment from transients. The I-Line Plug-On Unit with Surgelogic Transient Voltage Surge Suppressor (TVSS) is a modular parallel TVSS device designed for service entrance, distribution, or branch panel applications. The device is a multi-stage suppression circuit consisting of field-proven, fast-acting 34 mm metal oxide varistors (MOVs). Each MOV is thermally protected for low current faults, and each module is fused. The I-Line plug-on unit with Surgelogic TVSS device is a high performance surge suppressor package incorporating individual modules for each phase. Modes of protection include: Line-to-Neutral (L N) Line-to-Ground (L G) Neutral-to-Ground (N G) Line-to-Line (L L) A filter provides EMI/RFI noise filtering. The suppression elements are encapsulated in a UL Recognized thermosetting epoxy material another performance element that provides additional protection. Each surge suppression mode is individually fused and uses circuitry with thermal cutouts to isolate the TVSS and ensure shutdown in the event of MOV damage during severe overvoltages even when operated on high fault current power systems. Online diagnostics continuously monitor the unit status, and LEDs signal a loss of a suppression circuit. An audible alarm with an enable/disable feature and dry contacts are included in the standard diagnostic package. Design Features Same easy installation as I-Line circuit breaker Requires 13.50 in. (343 mm) of mounting space FC units mount in the same mounting slots as FA circuit breakers. FI units mount in the same mounting slots as KA circuit breakers Can be applied in a six-disconnect panel or switchboard (TVSS counts as one disconnect) High-energy parallel design for ANSI/IEEE C62.41 and C62.45 category B and C3 applications. 2 2007 Schneider Electric All Rights Reserved 05/2007

Application Information Application Information The effects of lightning and the damage caused by lightning-generated transients are well known. The failure of electronic equipment in a facility located in a high lightning area can easily be attributed directly to lightning-generated transients. Transient protection can be installed on the power distribution system to protect this equipment from these externally generated transients. Lower magnitude transients generated within a facility and their effect on microprocessor-based equipment are less obvious than the transients induced by lightning. Transient voltage generated from inductive motors, pumps, electric welders, etc., may not be large enough to cause immediate damage, but they can cause equipment to malfunction. A damaging transient voltage can enter a facility from several locations. The highest level of protection should be provided at the service entrance. A second level of protection should be provided at distribution points serving critical areas, for example, computer rooms, accounting areas, and laboratories. Other facility entry points that should be protected include panels serving outdoor lights, or outdoor equipment such as motors. Protection should also be provided for critical areas with equipment essential to the company. Square D brand TVSS products offered by Schneider Electric provide protection at every level of the electrical distribution system. Typical applications include: Banking Transportation Retail Education Wastewater/Sanitation Utility Government Medical Insurance Petrochemical Financial Data Processing Military Telecommunications Publishing Automated Manufacturing 05/2007 2007 Schneider Electric All Rights Reserved 3

Selection and Specifications Selection and Specifications Model Number Format FC 4 IMA 16 C The model number format consists of: Device Type, Voltage Code, TVSS Model, Surge Current Rating Code, and Option Code. The possible device types and codes are shown in the tables below. Option Code Surge Current Rating Code TVSS Model (IMA only) Voltage Code Device Type In the example at left, FC4IMA16C is an integral suppressor for 480Y/ 277 Vac 3-phase, 4-wire, 160 ka surge capacity with surge counter. Specifications Device Types, Interrupting Ratings, and Continuous Current Ratings Device Type Interrupting Rating @ 240 Vac @ 480 Vac @ 600Y/347 Vac Continuous Current Rating FC 100 ka 65 ka 60 A FI 200 ka 200 ka 100 ka 60 A Voltage Codes and Systems Voltage Code Voltage System 1 120/240 Vac 1-phase, 3-wire 2 208Y/120 Vac 3-phase, 3-wire or 4-wire 3 240/120 Vac 3-phase, 4-wire (high leg Delta) 4 480Y/277 Vac, 3-phase, 3-wire or 4-wire 7 380Y/220 Vac, 3-phase, 3-wire or 4-wire 8 600Y/347 Vac, 3-phase, 3-wire or 4-wire Surge Current Rating Codes and Surge Capacities Surge Current Rating Code Per Phase Per Mode L N L G N G 12 120 ka 60 ka 60 ka 120 ka 16 160 ka 80 ka 80 ka 120 ka 24 240 ka 120 ka 120 ka 120 ka Surge Suppressor Options, Descriptions, and Option Codes Option Description Option Code Surge counter Displays the combined total number of transient voltage surges detected from L N, L G, N G, and L L since the counter was last reset. C Remote monitor Displays the alarm status of the surge protective device up to 1000 ft (305 m) away from the unit. This option uses the dry contacts. Order catalog number TVS12RMU Dry contacts Provides available Form C type contacts. Standard Audible alarm with enable/disable switch Provides audible indication that there is a loss of protection. Standard 4 2007 Schneider Electric All Rights Reserved 05/2007

Selection and Specifications UL Suppression Voltage Ratings IMA Series Voltage Specifications UL Suppression Voltage Rating (SVR) Partial Catalog Number Voltage Service L N L G N G L L MCOV Surgelogic I-Line Plug-on TVSS Unit FC1IMA FI1IMA FC2IMA FI2IMA FC3IMA FI3IMA FC4IMA FI4IMA FC7IMA FI7IMA 120/240 Vac, 1-phase, 3-wire 208Y/120 Vac, 3-phase, 3-wire or 4-wire 240/120 Vac, 3-phase, 4-wire (high leg Delta) 480Y/277 Vac, 3-phase, 3-wire or 4-wire 380Y/220 Vac 3-phase, 3-wire or 4-wire 400 400 400 800 150 400 400 400 800 150 800/400 800/400 400 1500/800 275/150 800 800 800 1600 320 800 800 800 1600 320 600Y/347 Vac, FI8IMA 1200 1200 1200 2000 420 3-phase, 3-wire or 4-wire MCOV = Maximum Continuous Operating Voltage Not available as FC device Standard Features and Descriptions Feature Description Environmental Relative humidity: 0 to 95% non condensing Operating frequency: 47 63 Hz Surge suppression operating temperature: -40 +65 C (-40 +149 F) Storage temperature: -40 +65 C (-40 +149 F) UL 1449, Second Edition, UL 1283 Compliance standards culus Listed as a circuit breaker in compliance with UL 489/CSA C22.2 No. 0.5 (TVSS unit only) Meets 2002 NEC Article 285.6 Fused suppression Fused with individual surge-rated fuses (200 kair) paths Thermal Thermal cutout for low current faults protection On-line test functions Diagnostics Indication per phase Service indicator shown on the front panel of each TVSS unit Replaceable Separate, replaceable modules for each phase modules Self-contained suppression circuits and filtering for each module LED indicators Indication of loss of protection Suppression Individually-fused modules Solid state Bi-directional Front panel alarm Includes an enable/disable switch High-energy Category A, B, and C3 applications parallel design EMI/RFI Filtering Up to -50 db (100 khz to 100 MHz) Short-circuit 200 ka (TVSS modules only) current rating Duty cycle tested ANSI C62.41 C3, Minimum 5000 impulses 10 ka 20 kv Warranty Five years Surge counter liquid crystal display may not indicate at temperatures less than -20 C (-4 F) 05/2007 2007 Schneider Electric All Rights Reserved 5

Replacement Parts Replacement Parts MA Module Replacements Voltage System 120/240 Vac, 1-phase, 3-wire 208Y/120 Vac, 3-phase, 3 wire or 4-wire 240/120 Vac, 3-phase, 4-wire (high leg Delta) 480Y/277 Vac, 3-phase, 3-wire or 4-wire 380Y/ 220 Vac, 3-phase, 3-wire or 4-wire 600Y/347 Vac, 3-Phase, 3-wire or 4-wire Peak Surge Current Rating Catalog Number Phase A Phase B Phase C 120 ka MA1IMA12 Empty MA1IMA12 160 ka MA1IMA16 Empty MA1IMA16 240 ka MA1IMA24 Empty MA1IMA24 120 ka MA1IMA12 MA1IMA12 MA1IMA12 160 ka MA1IMA16 MA1IMA16 MA1IMA16 240 ka MA1IMA24 MA1IMA24 MA1IMA24 120 ka MA1IMA12 MA3IMA12 MA1IMA12 160 ka MA1IMA16 MA3IMA16 MA1IMA16 240 ka MA1IMA24 MA3IMA24 MA1IMA24 120 ka MA4IMA12 MA4IMA12 MA4IMA12 160 ka MA4IMA16 MA4IMA16 MA4IMA16 240 ka MA4IMA24 MA4IMA24 MA4IMA24 120 ka MA7IMA12 MA7IMA12 MA7IMA12 160 ka MA7IMA16 MA7IMA16 MA7IMA16 240 ka MA7IMA24 MA7IMA24 MA7IMA24 120 ka MA8IMA12 MA8IMA12 MA8IMA12 160 ka MA8IMA16 MA8IMA16 MA8IMA16 240 ka MA8IMA24 MA8IMA24 MA8IMA24 With all system voltages, TVSS devices must be grounded in accordance with all applicable standards. Phase B modules are different than Phase A and Phase C modules. Surgelogic Device Mounted in Panel with 4-Piece Trim Installed 6 2007 Schneider Electric All Rights Reserved 05/2007

Dimensions and Weights Dimensions and Weights 5.07 [129] 12.16 [309] 13.50 [345] Weight: 18.90 lb (8.60 kg) in. Dimensions: [mm] FC I-Line Plug-On Unit (Front View) 5.07 [129] 12.16 [309] 13.50 [345] Weight: 23.30 lb (10.60 kg) in. Dimensions: [mm] FI I-Line Plug-On Unit (Front View) 05/2007 2007 Schneider Electric All Rights Reserved 7

Schneider Electric USA 1601 Mercer Road Lexington, KY 40511 USA 1-888-SquareD (1-888-778-2733) www.us.squared.com Schneider Electric Canada 19 Waterman Avenue, M4B 1 Y2 Toronto, Ontario 1-800-565-6699 www.schneider-electric.ca 1310CT0201R5/07 2007 Schneider Electric All Rights Reserved Replaces 1310CT0201R3/03 April 2003. 05/2007