Perle 10GT Media Converter Modules

Similar documents
Perle 10G Media Converter Modules

Perle 10GT Media Converters

Perle 10G Media Converter Modules

Perle Cx-10GR-STS Media Converter Modules

Perle S-10GRT-SFP Media Converter Installation Guide

Perle Protocol Transparent Media Converter Modules

Perle Gigabit Media Converter Module. Installation Guide P/N

Perle 10/100 Ethernet Media Converter Module. Installation Guide. P/N (Rev C)

Perle MCR200 Installation Guide

Perle Gigabit Media Converters

Perle SMI Media Converter Installation Guide

Perle 10/100/1000 Ethernet Extender Modules. 10/100 10/100/1000 (Gigabit)

Perle PoE/PoE+ 10/100 Ethernet Media Converters

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converters

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Perle Advanced Powered Ethernet Extenders Installation Guide

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

USER S MANUAL. 10/100/1000Base-T 1000Base-SX/LX Gigabit Ethernet Converter GEP-5300TF-C GEP-5400TF-C

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

IFS MC201-1P/1FS User Manual

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

Signamax Connectivity Systems Dual Rate SFP Converter Series U S E R S

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Connects 1000BASE-T twisted-pair to 1000BASE-SX/LX fiber.

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Gigabit Ethernet Media Converter

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

PCI Express Gigabit Ethernet Adapter. User's Guide

FCC Statement. Trademarks. Preface. Gigabit Ethernet Media Converter

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

LNX-0702G-SFP Series

Preface. Manual Revisions. Trademarks

10 Gigabit Ethernet Copper-to-Fiber Media Converter - Open SFP+ - Managed

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

The RFS-105 / RFS-108 is a high-performance Fast Ethernet switch, with all ports capable of 10 or 100Mbps auto-negotiation operation.

These tiny media converters are perfect for bringing fiber to the desktop.

ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT.

Add 10/100 copper ports to a High Density Media Converter Chassis.

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Raven Series Standalone Media Converters

10/100Base-TX to 100Base-TX Mini Converter. Operation Manual

IMC-21GA Quick Installation Guide

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

LNX-1002C-SFP Series

PCI-E Dual / Single Port 10 Gigabit Ethernet Adapter

HES-3106-PLUS SERIES

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

GEU-0520 GEU QIG Manual

Port Type Link Status (Left Side LED) Speed (Right Side LED) Green solid: Link detected/no activity Off: No link/card offline

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

16-SLOT IN-BAND MANAGEMENT CHASSIS

LevelOne. User Manual GSW-1656/GSW /24-Port Gigabit Switch w/ 4-Port SFP. Version

Rugged Industrial Media Converter

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

10/100/1000Base-T to 1000Base-FX Switch Converter User Guide

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Converts any fiber optics type interface to any other fiber optics type interface.

Owner s Manual. Media Converters Models: N SC & N ST

TF-3239DL 10/100Mbps PCI Network Adapter

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Bridge Module. Installation Guide and Users Reference Manual

Fast Ethernet Converter. User Guide MICROSENS

HDMI Optical Extender USER MANUAL VE882 / VE892

Preface. Media Converter

MC100FX-TX-PoE Media Converter User Manual

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

H3C SecPath M9000-S NSQM2MPUD0 main processing unit

The Gigabit Ethernet Media Converter fully complies with IEEE802.3ab 1000Base- T and IEEE802.3z 1000Base-SX/LX Gigabit Ethernet standards.

GSW User Manual. 4-Port TP + 1-Port SFP Gigabit Ethernet Switch. Ver

Fast / Gigabit Ethernet Switch Module. MII series. User's Manual

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

FNC-0108TX 10/100Mbps Fast Ethernet Adapter. User s Manual Version:1.0

5/8 Port Gigabit Ethernet Switch

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

PLANET Fiber Transceiver MFB-Series/MGB-Series/MTB-Series

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

32/64-bit PCI Bus 1000BASE-SX Gigabit Fiber Ethernet Adapter. User s Guide

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

FCC Certifications. CE Mark Warning

CONVERTEON Family. One-Slot Chassis AT-CV1000. Installation Guide Rev. A

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Transcription:

Perle 10GT Media Converter Modules Installation Guide C-10GT-SFP CM-10GT-SFP C-10GT-XFPH CM-10GT-XFPH P/N 5500337-10 (Rev B)

Overview This document contains instructions necessary for the installation and operation of the Perle C/CM-10GT Media Converter modules. These models are used in conjunction with a Perle Media Converter chassis. Each module contains one pluggable transceiver port that permits insertion of a SFP+ or a XFP fiber module and one integrated RJ-45 (copper) port. These media converter modules can use either Perle Systems or third party MSA compatible 10G XFP or SFP+ modules including support for the following standards: 10GBase-SR, 10GBase-LR, 10GBase- ER, 10GBase-LRM and 10GBase-ZR. The C/CM-10GT-SPF supports one low power transceiver (SFP+), whereas the C/CM- 10GT- XFPH supports one high power transceiver (XFP) (up to power level 4). These modules take two slots within a Perle Media Converter chassis The C model modules are the unmanaged modules and the CM models are the managed modules. For information on the management options of the CM modules refer to the Perle MCR- MGT User s Guide that came with your Perle Management Module. All combination of modules within the chassis cannot exceed the chassis power input consumption. The full power consumption for Perle Media Converter chassis can be found on the Perle website. Model Port 1 Port 2 Type C-10GT-SFP SFP+ RJ-45 unmanaged CM-10GT-SFP SFP+ RJ-45 managed C-10GT-XFPH XFP RJ-45 unmanaged CM-10GT-XFPH XFP RJ-45 managed Note: The C/CM-10GT-SFP media converter module can operate as a 1G media converter module if a 1G fiber transceiver has been inserted into the SFP+ transceiver port. Visit Perle s web site for the most up to date Installation guides, models and specifications: http://www.perle.com/ Perle C/CM-10GT Media Modules Installation Guide 2

Getting to know your C/CM-10GT Media Converter Your C/CM-10GT Media Converter package consists of the following items: C/CM-10GT module with one transceiver port (SFP+ or XFP) and one RJ-45 (copper) port. This guide Front View Perle C/CM-10GT Media Modules Installation Guide 3

Installation The default switch setting (all switches in the UP position) will work for most installations. The Auto-Jumper is set to Auto for Ethernet Auto detection. These are the steps required to configure the Perle C/CM-10GT module. 1. Set the Auto-Jumper switch. (optional) 2. Set the DIP switch settings. (optional) 3. Install the module into the chassis. See Installing Modules. 4. Insert the appropriate SFP+/XFP into the transceiver port. 5. Connect the fiber cable. 6. Connect the RJ-45 (copper cable). See Copper Cable Requirements. C/CM-10GT-SFP or C/CM-10GT-XFPH Perle C/CM-10GT Media Modules Installation Guide 4

DIP Switch Settings The DIP switches are located on the module. Note: Switch changes made when the module is powered up take effect immediately and will result in a link reset on both ports. Operating Mode (Switch 1) Switch Position Mode Up (default) Down Data Test Data: In Data mode, data will flow between the fiber connection and the copper connection. Test: Test Mode is used to run diagnostics, enable loopback and for running the Built In Link Tests. Note: The Operation Mode (Switch 1) affects the function of DIP Switches 2 and 3 when in Test mode. Link Mode (Switch 2 Data Mode) Switch Position Mode Up (default) Down Smart Link Pass-Through Mode Standard Mode Smart Link Pass-Through: In this mode, the link state on one port connection is directly reflected through the media converter to the other port connection. If link is lost on one of the connections, then the other link will be brought down by the media converter. Standard Mode: In this mode, the links can be brought up and down independently of each other. A loss of link on either connection can occur without affecting the other fiber connection. Perle C/CM-10GT Media Modules Installation Guide 5

Test Function (Switch 2 Test Mode) Switch Position Type Up (default) Down Built In Link Test (BILT) Loopback Built In Link Test: Set Switch 2 to the Up position for the C/CM- 10GT media converter module to initiate the Built In Link Test on port 1. These tests consist of the media converter module generating test patterns to be sent out on port 1 to the remote media converter module. If the remote media converter module is also a compatible 10GBaseT media converter module then the remote media converter module will automatically be put into test mode. Note: The BILT can operate on 10G modules. This feature can also be used with Perle S-10G media converters Loopback: If Switch 2 is down, the specified port will be forced into loopback mode (switch 3 determines the port number). Data received on the receiver (RX) will be looped back to the transmitter (TX) connection. This mode is not used in conjunction with BILT. It can be used when other data generation methods are used. Illustration of the Built In Link Test Local C/CM-10GT Configuration Test Mode (Switch 1 Down) Test Function (Switch 2 Up) Remote-C/CM-10GT Configuration All switches in the Up position Perle C/CM-10GT Media Modules Installation Guide 6

Sequence of Events 1. The Local C/CM-10GT media converter module sends the Remote C/CM-10GT media converter module a signal to go into test mode. 2. The Remote C/CM-10GT media converter module turns on test mode. 3. Built In Link Test data is sent from the Local C/CM-10GT media converter module to the Remote C/CM-10GT media converter module. 4. The Remote C/CM-10GT media converter module analyses the received test data and sends its own test data plus a diagnostic code back to the Local C/CM media converter module. 5. If the PWR LED on the Local C/CM media converter module blinks red, this connection may require further testing. The PWR LED should flash green to indicate that there have been no errors in the last second. 6. The Built in Link Test continues to run until Switch 1 on the Local C/CM-10GT media converter module is set to Data mode. Fiber Fault Alert (Switch 3 Data Mode) Switch Position Mode Up (default) Down Enabled Disabled Enabled: If the media converter module detects a loss of signal on the fiber port, the media converter module notifies the link partner on that same port that an error condition exists by bringing down the link. Disabled: The media converter module will not monitor for fiber fault. Perle C/CM-10GT Media Modules Installation Guide 7

Fiber Fault Alert Sample Config Media Converter Module A Configuration Link Mode Standard Mode Fiber Fault Alert Media Converter Module B Configuration Link Mode Smart Link Pass through Mode Fiber Fault Alert Sequence of Events 1. Media Converter Module A loses fiber connection (RX). 2. Media Converter Module A notifies the remote Media Converter Module that there is a fault on the Link. 3. Media Converter Module B detects loss of fiber link on receiver (RX). 4. Media Converter Module B turns off transmitter (TX). Port Selection (Switch 3 Test Mode) Switch Position Port Up (default) 1 Down 2 When Loopback mode is selected (Switch 1 and Switch 2 down), this switch specifies which port to enable loopback mode on. Perle C/CM-10GT Media Modules Installation Guide 8

EEE (Energy Efficient Ethernet) Switch Position Mode Up (default) Down Enabled Disabled Enabled: When enabled, the media converter will auto negotiate this capability with the attached EEE compliant devices/servers. Disabled: The media converter will not auto negotiate this capability with the attached EEE compliant devices/servers. Installing Modules 1. Set any jumpers and/or DIP switches on the module to the desired operating mode. 2. Gently slide the module into the slot until it becomes flush with the front of the chassis. Light pressure may be needed to seat the module. Do not force the module as you might damage the module. If there is resistance, remove the module and check the module s backplane connector for damage to the pins. If the module s backplane connector is not damaged, try to reinsert the module again. 3. Tighten the Captive retainer screw to ensure the module is locked in place. Caution: Observe electrostatic discharge precautions when installing or removing the module(s) from the Chassis. Failure to observe this caution could result in damage to the module(s) and/or chassis. Perle C/CM-10GT Media Modules Installation Guide 9

AUTO-Config Jumper (CM models only) The Auto-Config jumper is located on the outer edge, at the midpoint of the module. Jumper the top and middle pin to select Auto mode. Jumper the middle and bottom pin to select SW mode. AUTO: When set to Auto the module will, at power-up, check its internal flash memory to see if configuration information has been downloaded to it from a management module. If so it will use this configuration as its running configuration. If there is no configuration in flash it will read the settings of the DIP switches and use those as its running configuration. SW: When set to SW (Switch), the module will, at power-up, read the settings of the DIP Switches and use those as its running configuration. It will ignore any configuration information in its flash memory. NOTE: The default jumper setting is AUTO Perle C/CM-10GT Media Modules Installation Guide 10

Operation Status LED The Perle C/CM 10GT Media converters modules have three status LEDs located on the faceplate of the module. PWR - Power/Test Green On: Power is on and the module is in normal operation mode. Green blinking slowly: the module is in test or loopback mode. Red Solid: During power up: Hardware error detected. (See PWR Red LED Errors) Red Blinking quickly: Error detected. (See LK1/LK Errors) Red blinking slowly while in Test mode: Indicates an error within the last second. Perle C/CM-10GT Media Modules Installation Guide 11

LK1- Port 1 Activity On: Fiber link present. Blinking quickly: Fiber link present and receiving data. Blinking slowly: The fiber link has been taken down as a result of Smart Link Pass-Through. Off: No fiber link present. LK2 Port 2 Activity On: Copper link present. Blinking quickly: Copper link present and receiving data. Blinking slowly: The copper link has been taken down as a result of Smart Link Pass-Through. Off: No copper link present. LK1 LK2 Error Codes LK1 LK2 Meaning Off Off Incompatible SFP+ or XFP Off On Power Budget exceeded XFP s requesting more power than specified port rating. On Off SFP+ or XFP communication error C/CM-10GT unable to communicate with module On On Internal Error PWR-Red LED Errors LK1 LK2 Meaning Blinking n/a Blinking one second on, 3 seconds off: the maximum specified operating temperature within the inserted module has been exceeded Off Off Internal Hardware. Perle C/CM-10GT Media Modules Installation Guide 12

Troubleshooting General Ensure that the SFP+ or XFP module is inserted correctly into the transceiver port. Ensure that the copper cabling (RJ-45) meets Ethernet copper cabling requirements. See Copper Cable Requirements in this guide. No connectivity If unable to get full connectivity with all DIP switches in the UP position, these procedures can be used for troubleshooting. Built In Link Test The Built In Link Test requires two 10GBaseT modules/converters. Choose one side of the link to generate the test data (master side) and one side to receive and analyse the test data (slave side). 1. Set Switch 1 down and Switch 2 to the Up position (Built In Link Test) on the master side. 2. The master side automatically sends test data to the slave side. 3. The slave side analyses the received test data and sends its own test data plus a diagnostic code back to the master side. 4. If the PWR LED on the master side blinks red then this connection may require further testing. 5. If the PWR LED on the master side blinks green after several seconds of testing, then the SPF+/XFP link is passing the Built In Link Test. 6. The Built in Link Test continues to run until Switch 1 on the master side is set back to Data mode. Perle C/CM-10GT Media Modules Installation Guide 13

Loopback Test This mode is not used in conjunction with BILT. 1. If either media converter module is not a Perle 10GT module then you need to set loopback mode on one of the media converter modules. (See the User s Guide that came with that media converter module). 2. Use an alternative way to generate data to the unit set in loopback mode. Data received on the receiver (RX) will be looped back to the transmitter (TX) connection. Use a third party application to analyse the received data. Module Temperature Protection All C/CM-10GT modules come equipped with module temperature protection. Should an inserted SFP+ or XFP module operate above its specified maximum operating temperature, the C/CM- 10GT will reduce the power to that module. The C/CM-10GT will continue to monitor the modules temperature until the temperature is below the maximum operating temperature and then the C/CM-10GT will return the module to normal operating mode. Perle C/CM-10GT Media Modules Installation Guide 14

Technical Specifications Maximum Power Consumption 10GT to SFP 10* SFP+ Operating Temperature 0 C -50 C (32 F - 122 F) Storage Temperature -25 C -70 C (-13 F -158 F) Operating Humidity 5% to 90% non-condensing Storage Humidity 5% to 95% non-condensing Operating Altitude Up to 3,048 m (10,000 ft) Maximum Power Consumption 10GT to XFP 15* XFP Operating Temperature -40 C -75 C (-40 F - 167 F) Storage Temperature -40 C -85 C (-40 F -185 F) Operating Humidity 5% to 90% non-condensing Storage Humidity 5% to 95% non-condensing Operating Altitude Up to 3,048 m (10,000 ft) *Maximum rating for both media converter and modules inserted. Actual rating is dependent on the power consumption of the SFP+/XPF modules inserted. SFP+ and XFPH Feature Set MSA Compliant SFP/SFP+ MSA complaint Class 1,2,3 and 4 XFP modules for the C/CM- 10GT-XFPH 1G copper modules 1G fiber modules SFP+ supports CX1 modules XFP supports CX4 modules Fiber Cabling Requirements MM: SM: 50/125 microns 62.5/125 microns 9/125 microns Copper Cable Requirements Category 6A Straight through or Ethernet crossover Perle C/CM-10GT Media Modules Installation Guide 15

Compliance Information FCC This product has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. EN 55022 Class A WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. EN 55024 Class A Contacting Technical Support Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. A Technical Support Query may be made via this web page. www.perle.com/support_services/support_request.shtml Warranty / Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage. Details can be found at: http://www.perle.com/support_services/warranty.shtml Copyright 2017 Perle Systems Limited All rights reserved. No part of this document may be reproduced or used in any form without written permission from Perle Systems Limited. Perle C/CM-10GT Media Modules Installation Guide 16