Features MPS- Green Display MPS-VN-PC ure Sensors Features ure Ranges: Vacuum ure 0 to -0 inhg Positive ure 0 to 5 PSI Sensor : NPN or PNP Open Collector Transistor, 0VDC, 5mA Optional Analog, to 0mA Optional Analog, to 5VDC Switch Point and Window Comparator Mode Selectable Units of Measure (mmhg, -bar, -kpa, inhg) (kgf/cm, PSI, bar, kpa) Response Time Less Than.0 Milliseconds RoHS Air and Non-Corrosive Gases Error Message MPS- Programming Options MPS-VN-PG Mounting Bracket MPS-ACCK Included with Sensors. WRA7 with MPS-VN-PG s Change N.O. / N.C. Units of Measure change EZY Mode Hysteresis Mode Window Comparator Mode Auto Teach Mode Auto Surveillance Mode Display Refresh Settings Response Time Display Peak / Bottom Difference Value Special Display Features Lockout Option Peak Value at a Touch Bottom Value at a Touch Zero Reset / Green LED Display Options Peak Surveillance Mode Energy Savings Mode Scan Mode Password Lockout Error Mode Setting of Decimal Point 8
Ordering Information Specifications ure Sensors MPS- Ordering Numbers ure Range Port Size Circuit Electrical Connector Part Number 0 to -0 inhg /8 NPSF* PNP Sourcing Pin, M8 MPS-VN-PC M Lead Wire MPS-VN-PG NPN Sinking Pin, M8 MPS-VN-NC M Lead Wire MPS-VN-NG PNP Sourcing Pin, M8 MPS-PN-PC M Lead Wire MPS-PN-PG 0 to 5 PSI /8 NPSF* NPN Sinking Pin, M8 MPS-PN-NC M Lead Wire MPS-PN-NG PNP Sourcing with -0ma Pin, M8 MPS-PN-PCI PNP Sourcing with -5VDC Pin, M8 MPS-PN-PCA * Mounting Bracket Included Specifications ure Range Vacuum (V) Positive (P) Units of Measure Display Resolution (with unit-switching function) bar: kpa: mmhg: inhg: 0.00 0. 0. bar: MPa: kgf/cm : PSI: 0.0 0.00 0.0 Proof ure -0 to 0 kpa 0 to MPa Media Air & Non-Corrosive Gases ure Port (N) /8" NPSF Operating Temperature to F (0 to 50 C) Storage Temperature to 0 F (-0 to 60 C) Humidity 5 to 85% RH Electrical Connection (C) -Pin, M8 Connector, (G) Grommet Open Lead Power Supply to VDC +0% or less, Ripple (Vp-p) 0% or less Display + / Digit, Color, 7-Segment LED Display Refresh. to.0 Seconds, Variable (Factory set at 0.) Control NPN (Sinking), PNP (Sourcing), Open Collector, max 5mA, Switch Signal, NPN or PNP, Normally Open or Closed, LED Indicator Modes Hysteresis or Window Comparator Response Time ms or less,(variable, 8, 0ms) Analog Repeatability Voltage Current ± 0.% of F.S. ± digit or less ± 0% of F.S. ± digit or less to 5VDC ( + 0.0V, 5 + 0.0V); Outout Impedance kω; Linearity 0.5% of F.S.; Response Time ms or less to 0mA; Linearity ±0.5% of F.S. or less; Maximum Load Impedance 00Ω with Power Supply Voltage of V; 600Ω with Power Supply Voltage of V; Minimum Load Impedance 50Ω to F (0 to 50 C) 5 C (77 C) + % of F.S. or less at range of to F (0 to 50 C) Thermal Error General Protection IP50, CE Marked, EMC-EN6000-6-: 00 Current Consumption <80mA Vibration Resistance 0 to 50Hz, Double Amplitude.5mm, XYZ, hrs. Shock Resistance 0G, XYZ Material Housing: ABS (gray), ure Port: Zinc Die-cast, Diaphragm: Silicone Mass.7 oz. (5g) (Not including cable) 9
Technical Information ure Sensors Sensor Pin Out Pin # Brown: VDC White: NPN / PNP Open Collector Blue: 0VDC Black: NPN / PNP Open Collector Sensor Pin Out with Analog Current Pin # Brown: VDC White: to 0mA Blue: 0VDC Black: PNP Open Collector Lead Wiring Brown VDC White NPN / PNP Open Collector Blue 0VDC Black NPN / PNP Open Collector Voltage Pin # Brown: VDC White: to 5VDC Blue: 0VDC Black: PNP Open Collector Internal Circuit for Open Collector and Analog Wiring Main Circuit D Tr Tr ZD ZD K ZD (Brown) +V Max. 5mA (Black) Out Load Max. 5mA Load (White) Out Max. 5mA (Blue) OV + DC 0.8V 0V Main Circuit Tr Tr ZD K D ZD (Brown) +V (Black) Out (White) Out Max. 5mA Max. Load ZD 5mA Option Load (Blue) OV + DC 0.8V 6.V Main Circuit Tr Tr ZD K D ZD ZD (Brown) +V (Black) Out Max. 5mA (White ) Analog -0 ma Option (Blue) OV Load + DC 0.8V 6.V NPN ( Open Collector ) PNP ( Open Collector ) PNP (with Analog )! Cautions The MPS- ure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Operating Environment Parker Sensors have not been investigated for explosionproof construction in hazardous environments. Do not use with flammable gases, liquids, or in hazardous environments. Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. Operations Dedicate a power supply of 0.8 to 6.VDC to the sensor and set the ripple to Vp-p0% or less. Avoid excessive voltage. Avoid voltage surges. A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. Verify the operating media is compatible with the specified sensor. Check the chemical make-up, operating temperatures, and maximum pressure ranges of the system before installing. Installation of air dryer system is recommended to remove moisture. Installation Never insert an object into the pressure port other than an appropriate fluid connector. Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0V. Do not connect the output lead wires (black / white) to the power supply. s not being used should be trimmed and insulated. Install as shown using the metal mounting bracket. Error Messages Display Description Solutions Err Zero Reset Error Reset Zero Below % of F.S. Er System Error (Internal) Contact Factory CE Over current of Load current exceeds maximum 5mA. FFF FF Applied pressure exceeds pressure range Apply pressures within the rating of the sensor 0
Dimensions ure Sensors Dimensions N /8" Female.06 (7).8 (,5). (8,5).5 ().5 (6.) Cable Length: 000mm.5 (6.) M8 -Pin Connector.6 (,) N /8 NPT Ø x Ø.5 Tube Connection Venting Port White: OUT Brown: +V Black: OUT Blue: 0V Grommet Lead MPS-ACCK Mounting Brackets (Included).55 ().8 (7).98 (5). (5,5).55 ().06 (7).0 (8).69 ().7 (5).77 Dia (,5).87 (). (6). (5,5).77 Dia (,5).5 ().5 ()
Programming Features ure Sensors See page 8 for Symbol Explanation Hold x Set Open or Closed Selecting Units of Measure Easy Mode Activation x Mode Hysteresis or Window Comparator x Switch Point Setting Hysteresis Mode x Mode Hysteresis or Window Comparator Window Comparator Mode Low High 5 x 6 Switch Point Setting Hysteresis Mode 5x Automatic Teach Mode & Auto Surveillance 7 6x Display Refresh Settings / Response Time Interval Vacuum Cycle Window Comparator Mode Low High Release Cycle Note: When Auto Survelillance is turned on P is added to setting, is turned off and P- becomes. 8 7x Display Peak Value 9 8x Special Display 0 9x Bottom Value or Features Their Difference Display Color Choices and / or Green, Energy Save Or x to Return Wait Seconds On Off Green Green Green Green Hold x Hold x x x for Seconds Zero Reset Lock Unlock Peak Value Bottom Value
Accessories ure Sensors Accessories Cables CB-M8-P-M, Female to Open Lead.8.96 (5) Dia 6.56 ft (m).6 () CB-M8-P-5M, Female to Open Lead.96 (5) Dia 6.0 ft (5m).6 () CB-M8-P-5M-90, Female to Open Lead.8.8 CB-M8-P-M8-M, M8 Female to M8 Male 6.56 ft (m) Pin Out Connection Female Interface -Pin, M8.96 (5) Dia Male Interface -Pin, M8.6 ().8.96 (5) Dia 6.0 ft (5m).87 ().75. (9) (0,7) Cable Pin Color Brown White Blue Black MPS-ACCH7 Panel Mounting Bracket.7 (,8).57 (0).57 (0). (,) Knockout. (6) (+0.5, -0.). (6) (+0.5, -0.)