INTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module

Similar documents
INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual

SL Interpreter Compact

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Introduction Central control equipment Contribution equipment CCS 800 Ultro Discussion System Data Brochure 1. 1.

CCS 800 Ultro Discussion System Data Brochure

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

TELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

DCN Next Generation Simultaneous Interpretation. en Software User Manual LBB 4172/00

TOA ELECTRIC CO., LTD.

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

DCN-D Conference Delegate Units DCN-DS/L, DCN-DCS, DCN-DV, DCN-DVCS. Installation and Operation manual

MASELEC MTC-6 master transfer and monitor system

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

BS 15 BASIC SERIES USER MANUAL FOR THE SINGLE CHANNEL BELTPACK CONTENTS

SoundwebTM. Installation Guide

CCS 800 Ultro. Installation and Operating Manual Discussion System

DCN Simultaneous Interpretation. Software User Manual en LBB 3572

INTERPRETER CONTROL UNIT MODEL PL ICU 2 2 (2 INPUTS 2 OUTPUTS) INSTRUCTION MANUAL Technical Data Warranty Information

TELIKOU Intercom System

Ref. No " DUAL CD PLAYER, MIXER AND CASE USER MANUAL

IC-I AND IC-I F GENERAL DESCRIPTION SPECIFICATIONS. Output Impedance: Phones: 60 ohms (Unit is designed for use with ohm phones.

MCS 50. Discussion Control Unit. 1 of 7

Plena Universal Pre-amplifier. Installation and Operating Manual LBB 1920

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

The Digimic microphone

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems

CS-120. Conferencing and Discussion / Interpretation System. Digital Conference System. conference system. CS-120 Series

CORRIGENDUM No: 1 to the TECHNICAL SPECIFICATIONS

Diplomat Digital Conference System

TELIKOU Intercom System FT-800 (7+1) Channel Main Station Instruction Manual

3. This unit should not be exposed to dripping, splashing or excessive moisture or objects filled with liquid.

IR Wireless Interpretation System

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

CU 4005 CDS 4000 Central Control Unit for 50 Conference Units

HCS-5300MA/ 80 Digital Infrared Wireless Conference Main Unit

PRE116/126. User Manual.

INSTALLATION INSTRUCTIONS

Gonsin Digital Conference Equipment Co., Ltd.

Power LED Beam 56 Narrow

User Operating Manual

MANUAL AND USER GUIDE

LS351 Desktop, single circuit unit, with XLR connectors (XLR3F, XLR3M loop-through). Local plug-in PSU option.

Wireless DMX Control. Show Performer DMX Controller. Stage Desk 48 DMX Controller

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

User Guide PRNT

INSTALLATION INSTRUCTIONS

TPM4200FX MKII V2 24- BIT EFFECTS PROCESSOR MAIN MID LOW FOOT SW FX RETURN FX SEND OUT. 12KHz. 2.5KHz USB PLAYER CH4 OFF COMP./LIM.

Operating Manual AMIS60, 60w Mixer Amplifier & AMIS120, 120w Mixer Amplifier

A120 A W/240W PA Mixer-Amplifier 70V/100V

CU 6005 DCS 6000 Medium Power Central Control Unit

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

IMPORTANT SAFETY INSTRUCTIONS

VM SERIES Rackmount 100V mixer-amplifiers

Control Unit CU-12 / Interpreter Console IC-12. INTERPRETATION System. User Manual

I T S A L L A B O U T T H E M U S I C

Gonsin Digital Conference Equipment Co., Ltd.

AMP20. User Manual.

Orbis MU 21. Digital Delegate Microphone Unit with Loudspeaker Order #

service Studio design and build Acoustic consultancy and treatment Sound service Studio design and build Acoustic consultancy and treatment Sound

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

Instruction Manual. G.R.A.S. 12AA 2-Channel Power Module with gain, filters and SysCheck generator. LI April 2015

CLOUD CX261 Single Zone Mixer

AUDIO D-Type Pin-outs TALKBOX INSTALLER 12 1U RACK BOX BCD 25/09/07. Broadcast Audio Custom Manufacture Design and Consultancy

Plena Feedback Suppressor. Installation and Operating Manual LBB 1968

PS 6379 Mk2 SIX CHANNEL MASTER SPEAKER STATION

GENERAL DESCRIPTION SPECIFICATIONS. output Impedance: Phones: 60 ohms (Designed for use with ohm phones.)

BS 217 DUAL CHANNEL MASTER STATION USER MANUAL

GSGC5G ISDN MIXERS PRODUCT DETAILS

SoundwebTM. Installation Guide

Achat 110 MA active full-range speaker. user manual

HCS-48U7C Chairman Unit with Voting and Channel Selection

AMU1-CHD+MK2 AUDIO MONITORING UNIT

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

PROTECH.

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

1081R Remote Mic-Line Rack

INFERNO DANTE NETWORK AUDIO SINGLE USER COMMENTARY BOX PRODUCT DETAILS

Installation & Operation Guide

MANUAL CONCEPT1 CONCEPT1T

QUICKSTART GUIDE ENGLISH ( 3 9 ) MANUAL DE INICIO RÁPIDO ESPAÑOL ( ) GUIDE D UTILISATION RAPIDE FRANÇAIS ( )

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN

ASK-4 #101-DV AUDIO MONITORING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

PTAU45. 2x120W Max Stereo Power Amplifier with AUX CD/USB inputs and MIC PAGER.

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order #

Marshall Electronics. AR-AM4-BG Analog Audio Monitor. Operating Instructions

ARTIST. CCP-1116 Commentary Control Panel

TA12 full-rangespeaker. user manual

PXR 1506 / WATT MIXER AMPLIFIER

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

CCS 1000 D Digital Discussion System 1. CCS 1000 D Digital Discussion System Compact yet versatile

1073N. Channel Amplifier. User Manual Issue 1.3

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN

MA100 full-range speaker. user manual

Quickstart Guide (English)

Audio Interface. User s Manual 14 HP. Eurorack Synthesizer Modules

TELOS INFINITY MP-16 Digital Intercom Master Panel

VE9121 Series Classroom Audio Management System

bi-way starter kit lbb 7026/65 MI v.1.2 mounting guide

MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER

Transcription:

INTEGRUS en Installation and User Instructions Integrus Language Distribution System LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker LBB 3422/20 Integrus Audio Input and Interpreters Module

INTEGRUS Installation and User Instructions Safeguards Important Safeguards Prior to installing or operating this product always read the Safety Instructions which are available as a separate document.

INTEGRUS Installation and User Instructions Table of contents Table of contents 1 6-Channel interpreter desk with loudspeaker (LBB 3222/04)..................................1 1.1 Introduction......................................................................1 1.2 Front panel controls................................................................1 1.3 Rear panel controls.................................................................3 1.4 Interpretation procedures............................................................3 1.5 Configuring the interpreter s system....................................................4 1.6 Auto floor function.................................................................5 2 Integrus audio input and interpreters module (LBB 3422/20)..................................6 2.1 Introduction......................................................................6 2.2 Configuration.....................................................................7 3 Connecting to an Integrus transmitter.....................................................8 3.1 Connecting interpreters desks LBB 3222/04 directly......................................8 3.1.1 Maximum cable length for connecting interpreters desks LBB 3222/04..................9 3.1.2 Recording the audio channels..................................................10 3.2 Connecting interpreters desks LBB 3222/04 via the CCS 400 system........................11 3.3 Connecting other analogue conference systems..........................................11 4 Technical data.........................................................................12 4.1 LBB 3222/04 6-Channel interpreter desk with loudspeaker................................12 4.1.1 Physical characteristics........................................................12 4.1.2 Electrical characteristics.......................................................12 4.2 LBB 3422/20 Integrus audio input and interpreters module................................12 4.2.1 Physical characteristics........................................................12 4.2.2 Electrical characteristics.......................................................12 4.3 Connection details.................................................................13

INTEGRUS Installation and User Instructions

INTEGRUS Installation and User Instructions 6-Channel interpreter desk with loudspeaker en 1 1 6-Channel interpreter desk with loudspeaker (LBB 3222/04) 1.1 Introduction The LBB 3222/04 6-channel interpreter desk provides listening and speaking facilities for interpreters using the CCS 800, CCS 400 or non-bosch discussion systems. Up to 12 desks can be connected to an Integrus transmitter using the Integrus audio input and interpreters module (LBB 3422/20). It can distribute up to 6 outgoing languages. An auto-floor -feature is incorporated for relay interpretation. This allows a less well-known floor language to be translated by one interpreter into a language familiar to all other interpreters and relayed as the auto-floor. The LBB 3222/04 has an integral loudspeaker and is supplied with a microphone incorporating an illuminated status ring to warn everyone in the booth that the microphone is active. Two outgoing channels are provided, A and B, switchable by means of a channel select key. Note: Flashing indicators warn that the language channel occupied by this desk is also being used by one or more other desks. 1.2 Front panel controls The desk has the following front-panel controls and indicators (see figure 1.1): Figure 1.1: 1. Microphone activating key - 2-position toggle switch for activating the microphone. An interlock facility can be enabled (using the under-panel controls) that prevents the microphone being activated if the desk s outgoing language distribution channel is occupied by another desk. 2. Microphone status indicators - Two red LEDs to indicate that the microphone is active. 3. Microphone mute key - A non-locking push-button to temporarily mute the microphone. When pressed, the status indicators and status ring are off, but the outgoing language distribution channel remains occupied by the desk. 4. Microphone - Gooseneck microphone with integral status indicator ring. Figure 1.1 LBB 3222/04 6-channel interpreter desk

INTEGRUS Installation and User Instructions 6-Channel interpreter desk with loudspeaker en 2 5. Call-channel key - Non-locking push-button to route the microphone to the call channel for oneway communication with the operator (with priority over the A/B channel). The microphone status indicators and status ring are on when the call-channel key is pressed. The outgoing language distribution channel remains occupied by the desk. Not applicable for use with CCS 800 discussion systems. 6. Outgoing message key - Non-locking push-button to be used for signalling purposes. When pressed, contacts are closed. This switch is connected to the 6-pole DIN connector for custom wiring. 7. Incoming message indicator - A yellow LED with 1 k W series resistor connected to the 6-pole DIN connector. To be used for custom signalling purposes. 8. Tone/volume controls - Rotary volume, bass and treble controls for the headphone. 9. Volume control - Rotary volume control for builtin loudspeaker. 10. Monitor loudspeaker - Built-in loudspeaker for monitoring without headphones. The speaker is only active when the microphone is off. 11. Incoming channel selector - 8-position rotary switch to select either OR, OR2 or channels 1 to 6 for monitoring as incoming language. This switch is only active if the incoming channel pre-selector key is in the up -position. 14. A-B channel selector key - 2-position toggle switch for selecting either A or B. If use of channel B is inhibited, the outgoing channel will be the one pre-set for the desk by the under-panel A select control. If channel B is enabled, the outgoing channel can be selected with the channel-b select keys. 15. Outgoing channel-a indicators - 6 green LEDs to indicate which outgoing channel is assigned to the desk for channel A using the under-panel controls. 16. Outgoing channel-b indicators - 6 green LEDs to indicate which outgoing channel is assigned to the desk for channel B using the outgoing channel-b select keys. 17. Outgoing channel-b select keys - 6-way interlocking push-button array to select the outgoing channel when channel B is selected. 18. A-B channel select indicators - 2 red LEDs to indicate which channel, A or B, is selected. 19. Outgoing OR2 indicator - Green LED to indicate that the desk is enabled for relaying OR2 to other desks (using under-panel controls). 20. Engaged channel indicators - 2 yellow LEDs, one each for A and B, to indicate that the outgoing channel selected is occupied by one or more desks. A flashing LED indicates that the outgoing channel occupied by the desk is also being used by one or more other desks. Note: For a full explanation of terms OR and OR2, see section 1.6. 12. Incoming channel pre-selector key - 2-position toggle switch to select either OR when in the down -position, or the channel selected by the incoming channel selector knob when in the up - position. If OR is selected and OR2 is activated using the auto-floor-feature, the desk automatically receives OR2 for monitoring. 13. Incoming channel OR2 indicator - Green LED to indicate that OR2 is active instead of OR during relay interpretation.

INTEGRUS Installation and User Instructions 6-Channel interpreter desk with loudspeaker en 3 1.3 Rear panel controls The rear panel of the interpreter desk contains the following controls and connectors (see figure 1.2). Figure 1.2 Rear view of LBB 3222/04 Figure 1.2: 1. Headset switch - 2-position slide switch to select either the headset s microphone or the built-in gooseneck microphone. 2. System cable - 3 m long cable terminated with a 25-pole male D-type connector for connecting the desk to the preceding desk or to the central. 3. System connector - 25-pole female D-type connector (lockable) for connecting to the next desk. 4. Headphone connector - 6.3 mm jack socket for connecting the headphone. 5. Headset connector - 5-pole female 180 DIN connector for connecting a headset (in accordance with IEC 268-1 1). 6. Message connector - 6-pole female DIN connector for message function (if required). 1.4 Interpretation procedures The original floor language spoken by a delegate is distributed throughout the conference area, either via a PA system, or via built-in loudspeaker units on the delegates microphone units (both methods may also be used simultaneously). This floor language is also distributed to all interpreters desks, where through their headphone sets the interpreters can listen to the floor language to base their interpretations. The 6-channel interpretation system is operated completely independently from the system operator, and is operated as a stand-alone system only. The procedures used for interpreting the original floor language is understood by all interpreters, and where the floor language is not so well known, two different operational procedures can be used: normal operational mode and relay interpretation mode. In the normal operational mode, where the original floor language is familiar to all interpreters, the interpreters will listen via their headphone or headset to the original floor language. The translations are then fed to the appropriate channels on the delegate s program selector units or receivers. In a situation where interpreters are unfamiliar with the floor language (and therefore unable to translate it), the CCS 800 system has a relay interpretation facility. This facility allows for an interpreter who is familiar with the floor language to relay his translation to other interpreters to which they can base their own translations.

INTEGRUS Installation and User Instructions 6-Channel interpreter desk with loudspeaker en 4 1.5 Configuring the interpreter s system The configuration of the 6-channel interpreter s system is carried out independently of the CCS 800 system. The controls located under the removable panel on the desk must be pre-set before putting the system into operation. To gain access to the controls, remove the plastic protection cover and text plate located at the top of the unit. This is achieved by inserting a small pointed implement into the holes at either side of the cover and carefully pushing forward to lever it off (see figure 1.3). Set-up selector DIL switch 2 Switch On Off 1 Channel B disable Channel B enable 2 Mic. OR2 disable Mic. OR2 enable 3 Interlock enable Interlock disable 4 Slave Master 5 Loudspeaker Loudspeaker OR2 disable OR2 enable 6, 7, 8 Not used Figure 1.4 Factory setting of DIL switch 2 Figure 1.3 Under-panel controls on the LBB 3222/04 interpreter desk A-select switch The outgoing language distribution channel assigned to each desk must be pre-set using the A-select 6-position rotary switch. Each booth should be assigned a different channel (1 to 6). The language assigned to each channel can be written on the removable panel in the spaces provided alongside the outgoing channel A indicators. The appropriate LED will illuminate to indicate which language is assigned to a particular desk. Factory setting: channel 1. SW 2-1 SW 2-2 SW 2-3 SW 2-4 B-enable - If desks are not to make use of the B output, the B-enable switch must be switched on. The outgoing language distribution channel for each desk will then be determined by the A-select switch only (regardless of the position of the A-B channel selector key on the front panel). OR2 enable - To configure an auto-floor system, the desk from which the transfer interpretation will be made must have the OR2 function enabled. The outgoing channel OR2 indicator will illuminate on this desk. The B-enable switch must be off for this desk. Interlock - To prevent two or more desks using the same outgoing channel, the interlock feature can be enabled. When this switch is on, the microphone will remain inactive if an occupied outgoing channel is selected. Master / slave - If more than one desk is installed in a booth, the additional desks must be set with this switch in the on -position. The first desk in a booth (that nearest to the IR transmitter) must have this switch in the off -position. If only one desk is installed in the booth, this switch must also be off.

INTEGRUS Installation and User Instructions 6-Channel interpreter desk with loudspeaker en 5 SW 2-5 OR-only - When the OR-only switch is in the on -position, the loudspeaker will always monitor the floor channel. When the ORonly switch is in the off -position, the loudspeaker will automatically switch over to the OR2 channel when this channel is available. 1.6 Auto floor function To cater for circumstances where the original floor language is either well known or less well known, two different operational procedures can be utilised. Figure 1.5 Normal operation (OR1 active) In the normal operational mode (shown in figure 1.5), where the original floor language (OR) is familiar to all interpreters, they will listen to the original floor language for interpretation. The translations are then fed to the appropriate language distribution channels. In a situation where interpreters are unfamiliar with the floor language and therefore unable to interpret it, the system offers an automated relay interpretation facility ( auto floor - see figure 1.6). An interpreter assigned to translate the floor language, translates it into another language easily understood by other interpreters. The floor language (OR) on all interpreters desks will be replaced by this transfer interpretation. This transfer interpretation or auto floor (OR2) is then used as a base for further translations. In the example in figure 1.6, Japanese is the OR and the auto-floor facility is enabled on the Japanese interpreter desk using the set-up selector DIL switch under the removable panel (the outgoing OR2 indicator is illuminated on this desk). This interpreter selects outgoing channel B and automatically relays a French translation as OR2 to all other desks for interpretation and also feeds the French language distribution channel. The incoming channel OR2 indicator shows on all other desks that auto floor is active. Figure 1.6 Relay interpretation using the auto-floor feature (OR2 active)

INTEGRUS Installation and User Instructions Integrus audio input and interpreters module en 6 2 Integrus audio input and interpreters module (LBB 3422/20) 2.1 Introduction An Integrus audio input and interpreters module is required when an Integrus transmitter is to be used for direct connection of interpreters desks LBB 3222/04 (in combination with e.g. the CCS 800 system) or with analogue conference systems (such as the CCS 400). The interface module must be mounted in the transmitter housing. 4 1 5 2 4 3 1 Figure 2.1 Integrus audio input and interpreters module, rear view and PCB layout Figure 2.1: 1. Interface connector A 25-pole sub-d female connector for direct connection of up to 12 LBB 3222/04 interpreters desks or analogue conference systems with interpretation. 2. Positions for input transformers Eight input transformers can be mounted for galvanic separation of source and electronics inputs. The eight Integrus audio inputs at the 25-pole D-type plug can be isolated by adding eight audio transformers (Beyer type TR/BV3) in these positions. 3. Function switches Three DIL switches for determining module functionality. 4. PCB connector - A 55-pins connector that connects the module to the Integrus transmitter s main PCB. 5. Mounting plate.

INTEGRUS Installation and User Instructions Integrus audio input and interpreters module en 7 2.2 Configuration Before using the Integrus audio input and interpreters module, the operation mode must be chosen by setting the DIL function switches on the module s circuit board: Select the mode in which the module must operate: 1. As an interface to one or more LBB 3222/04 interpreters desks. 2. As an interface to other audio sources. Select if floor distribution (see section 1.6) should be enabled. 1. Enable floor distribution when LBB 3222/04 interpreters desks are directly connected 2. Disable floor distribution when LBB 3222/04 interpreters desks are connected via a CCS 400 system. Select the channels on which the module s signals will be distributed. The table below lists all the settings. Notes: If floor distribution is enabled (DIL switch III-4 off), the floor audio signal will be distributed on those channels where the interpretation microphone is switched off. When interfacing between more than one LBB 3222/04 interpreter desk and the infra-red system, or interfacing between the CCS 400 power supply and the infra-red system, the floor distribution should be disabled (DIL switch III-4 on). Do not use a CCS 400 power supply in combination with direct connection to LBB 3222/04 interpreter desks, as this will cause a fuse to blow. When the Integrus audio input and interpreters module is used in combination with audio signals connected to the cinch inputs of the Integrus transmitter, the signals on corresponding channels are mixed. Check the positions of the DIL-switches before mounting the LBB 3422/20 Integrus audio input and interpreters module in an Integrus transmitter. DIL Switch Function On Off I 1,2,3,4,5,6,7,8 Interpretation Direct connection to Connection to LBB 3222/04 interpreters desks other audio sources II 1,2,3,4,5,6,7,8 Interpretation Direct connection to Connection to LBB 3222/04 interpreters desks other audio sources III 1,2,3 Interpretation Direct connection to Connection to LBB 3222/04 interpreters desks other audio sources III 4 Floor distribution Disabled Enabled III 5 Channel selection Channels 8-15 Channels 0-7 III 6,7,8 Not used

INTEGRUS Installation and User Instructions Connecting to an Integrus transmitter en 8 3 Connecting to an Integrus transmitter 3.1 Connecting interpreters desks LBB 3222/04 directly An Integrus transmitter requires the LBB 3422/20 Integrus audio input and interpreters module to directly interface with one or more LBB 3222/04 interpreter desks. This module must be mounted in the transmitter housing (see the Integrus installation manual). Up to 12 interpreter desks can be loop-through connected to the module. The system cable of the first interpreter desk is connected to the 25-pole sub-d connector on the Integrus audio input and interpreters module. The system cables of the next desks are loopthrough connected to the system input plugs on the preceding desks. The floor signal for the interpreters desk is connected to the Aux-Left input of the Integrus transmitter with an XLR connector. The floor signal can come from a CCS 800 analogue conference system (i.e. the line output cinch connector, see the CCS 800 installation manual) or from an external audio source, such as an audio mixer. Note: To connect the floor signal, a cable with a male XLR connector and a male cinch connector must be made. See figure 3.1 and figure 3.2 for the wiring. Figure 3.1 Connecting one or more LBB 3222/04 interpreter desks directly to the modular IR transmitter The DIL switches on the Integrus audio input and interpreters module must be set to Direct connection to LBB 3222/04 interpreter desks (see section 2.2). The Aux. Input mode of the Integrus transmitter must be set to Emergency/Mono (see the Integrus installation manual). Integrus AUX-Left 1 2 3 XL CCS800 Line output Figure 3.2 Wiring of the cinch to XLR connecting cable

INTEGRUS Installation and User Instructions Connecting to an Integrus transmitter en 9 3.1.1 Maximum cable length for connecting interpreters desks LBB 3222/04 The maximum length of the cables to connect the interpreters desks to the Integrus transmitter depends on the number of interpreters desks. A leader cable connects the first interpreters desk to the transmitter. An extension cable may be needed between the interpreters desks. The table below shows the maximum extension cable length (additional to the standard 3 m cable) that can be used with different numbers of interpreters desks. Number of interpreters desks LBB 3222/04 2 4 6 8 10 12 Additional leader cable length between meter 100 50 35 15 5 0 first interpreter desk and transmitter Additional extension cable lengths meter 34 8 2.9 2.4 1.8 1 between interpreters desks Number of interpreters desks LBB 3222/04 2 4 6 8 10 12 Additional leader cable length between feet 328 164 115 49 16 0 first interpreter desk and transmitter Additional extension cable lengths feet 112 26 9.5 7.9 6.0 3.3 between interpreters desks

INTEGRUS Installation and User Instructions Connecting to an Integrus transmitter en 10 3.1.2 Recording the audio channels To record the audio channels, a connection box can be inserted between the interpreters desks LBB 3222/04 and the Integrus audio input and interpreters module LBB 3422/20. Such a connection box should be locally made. See figure 3.3 for the wiring. RECORDING EQUIPMENT Floor Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 14 x LBB 3422/20 Audio 1 input Audio 2 input Audio 3 input Audio 4 input Audio 5 input Audio 6 input Audio 7 input Audio 8 input Audio Comm Audio AF Supply (+12V) Supply (- 12V) Earth 1 14 4 18 2 16 5 17 7 19 8 22 6 20 11 23 9 21 3 15 24 25 12 13 10 1 14 4 18 2 16 5 17 7 19 8 22 6 20 11 23 9 21 3 15 24 25 12 13 10 LBB 3222/04 OR Floor Channel Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Busy in Comm. OR2 Auto Relay Supply (+27V) Ground Earth Figure 3.3 Connection box for recording audio and language channels

INTEGRUS Installation and User Instructions Connecting to an Integrus transmitter en 11 3.2 Connecting interpreters desks LBB 3222/04 via the CCS 400 system An Integrus transmitter requires the LBB 3422/20 Integrus audio input and interpreters module to interface with the CCS 400 discussion and interpretation system. This module must be mounted in the transmitter housing (see the Integrus installation manual). The CCS 400 system is connected to the Integrus audio input and interpreters module by means of a 25- pole sub-d connecting cable. The interpreters desks and the floor signal are connected to the CCS 400 system. See the CCS 400 installation manual for more information. 3.3 Connecting other analogue conference systems An Integrus transmitter requires the LBB 3422/20 Integrus audio input and interpreters module to interface with other analogue conference systems. This module must be mounted in the transmitter housing (see the Integrus installation manual). The analogue conference systems are connected directly to the Integrus audio input and interpreters module by means of a 25-pole sub-d connecting cable. For pinning information see chapter 4. It is also possible to connect a conference system directly to the Integrus audio cinch inputs of an Integrus transmitter. In that case the interface module is not necessary. Note: Before connecting the CCS 400 analogue conference systems, the DIL switches on the Integrus audio input and interpreters module must be set to Connection to other audio sources. For details of the required settings, see section 2.2. Notes: Before connecting other analogue conference systems, the DIL switches on the Integrus audio input and interpreters module must be set to Connection to other audio sources. For details of the required settings, see section 2.2. If galvanic separation is required, add Beyer type TR/BV3 audio transformers on the module s PCB (see section 2.1).

INTEGRUS Installation and User Instructions Technical data en 12 4 Technical data 4.1 LBB 3222/04 6-Channel interpreter desk with loudspeaker 4.1.1 Physical characteristics Mounting Table top or flush mounting Dimensions (H front x H rear x W x D) 20-58 x 250 x 189 mm (0.79 2.28 x 9.84 x 7.44 inch) Weight 1.75 kg (3.85 lb) Finish Light gray 4.1.2 Electrical characteristics Frequency response 125 Hz (-10 db) to 12.5 khz (-2 db) Rated equivalent sound < 32 db pressure due to inherent noise Total harmonic distortion < 5% at overload Cross talk attenuation > 66 db 4.2 LBB 3422/20 Integrus audio input and interpreters module 4.2.1 Physical characteristics Mounting Mounting plate and two screws included Dimensions (H x W x D) 100 x 45 x 231 mm (39 x 21 x 91 inch) Weight 188 g (0.41 lb) 4.2.2 Electrical characteristics Audio input level with AGC -16.5 dbv (150 mveff) to +3.5 dbv (1500 mveff) Audio input level without AGC -4.4 dbv (600 mveff) Asymmetric input impedance 10 kohm DC input impedance 200 kohm

INTEGRUS Installation and User Instructions Technical data en 13 4.3 Connection details System cable A 3 m long cable terminated with a 25-pole male D-type connector Pin nr. Function 1, 14 Floor line (OR) 2, 16 Outgoing language distribution channel 2 3, 15 Auto floor (OR2) 4, 18 Outgoing language distribution channel 1 5, 17 Outgoing language distribution channel 3 6, 20 Outgoing language distribution channel 6 7, 19 Outgoing language distribution channel 4 8, 22 Outgoing language distribution channel 5 9, 21 Call channel 10 Ground reference 12, 13 Supply ground 23 Status line 24, 25 Positive supply voltage System 25-pole female D-type connector connector Pin nr. Function 1, 14 Floor line (OR) ` 2, 16 Outgoing language distribution channel 2 3, 15 Auto floor (OR2) 4, 18 Outgoing language distribution channel 1 5, 17 Outgoing language distribution channel 3 6, 20 Outgoing language distribution channel 6 7, 19 Outgoing language distribution channel 4 8, 22 Outgoing language distribution channel 5 9, 21 Call channel 10 Ground reference 12, 13 Supply ground 23 Status line 24, 25 Positive supply voltage Headphone 6.3 mm jack socket connector Contact Function Tip Audio out Fling Audio out Sleeve Return Headset 5-pole female 180 DIN connector in connector accordance with IEC 268-11 Pin nr. Function 1 Mic. live 2 Mic. return 3 Left-hand headphone 4 Return both headphones 5 Right-hand headphone Message 6-pole female DIN connector connector Pin nr. Function 1 Connected to outgoing message key 2-3 Connected to outgoing message key 4 Connected via internal series resistor to incoming message indicator LED (anode) 5 Connected to incoming message indicator LED (cathode)

INTEGRUS Installation and User Instructions Product index Products LBB 3222/04 6-channel interpreter desk with loudspeaker......................................1 LBB 3422/20 audio input and interpreters module............................................6

INTEGRUS Installation and User Instructions

For more information please visit www.boschsecuritysystems.com 2005 Bosch Security Systems B.V. Data subject to change without notice 2005-04 9922 141 70164en