Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Similar documents
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Characteristics. Application RTU560. DIN Rail RTU 560CIG10. Data Sheet DIN Rail RTU 560CIG10

Characteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01

Application. Characteristics RTU560. DIN Rail RTU 560CIG10. Data Sheet DIN Rail RTU 560CIG10

DIN Rail RTU 540CMD01 Data sheet

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Remote Terminal Unit Connections and Settings

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Bus Connection Unit 560BCU04

Analog output 520AOD01 Data sheet

Binary output and supervision 520CSD01 Data sheet

ABB 520BID01 Binary Input datasheet

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3.

Control Panel CP600-eCo CP604, CP604-B

RTU500 series Data Sheet Power Supply CP-E 24/2.5

OnCell G3150A-LTE Series

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Control Panel CP600 CP651, CP651-WEB

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

HEC. General Operating, Maintenance and Installation Manual

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Control Panel CP600 CP635, CP635-B, CP635-WEB

TM221M16R controller M IO relay

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

TM3AI4 module TM3-4 analog inputs

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

TM221CE40R controller M IO relay Ethernet

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Features and Benefits. Certifications

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

+70 C -25 C 95% RH EMC

TM221CE24R controller M IO relay Ethernet

DI561 Digital Input Module

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

MGate 4101-MB-PBS Series

TM251MESC controller M251 Ethernet CAN

TM221ME32TK controller M IO transistor PNP Ethernet

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

Switching relay CT-IRE with 1 c/o (SPDT) contact

Control Panel CP600 CP635-FB, CP635-FW

TM241CE24T controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet

TM3TI4 module TM3-4 inputs temperature

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

DI572 Digital Input Module

TM241CE40R controller M IO relay Ethernet

AC 800M for Compact Product Suite Outline of all modules

DC561, digital input/output module,

TM3TI4 module TM3-4 inputs temperature

Messaging module CP-C MM

TM3DI16 module TM3-16 inputs

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

TM3TI8T module TM3-8 inputs temperature

TM241C40U controller M IO transistor NPN

GT- IRDM-9603 Product description Rev. 2 17/06/2014

TM241CE40R controller M IO relay Ethernet

TM241CE24U controller M IO transistor NPN Ethernet

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

TM241C24T controller M IO transistor PNP

TK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

Redundancy unit CP-A RU

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM241C40R controller M IO relay

DC562, digital input/output module,

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

TM221CE24T controller M IO transistor PNP Ethernet

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

TM241CEC24R controller M IO relay Ethernet CAN master

Feature and Benefits. Certifications

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

TM241CE40R controller M IO relay Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM221CE40R controller M IO relay Ethernet

TM241CE40T controller M IO transistor PNP Ethernet

TM251MESC controller M251 Ethernet CAN

NPort Z2150/Z3150 Series

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

DX561 Digital Input/Output Module

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

AI561 Analog Input Module

TM3DI16G module TM3-16 inputs spring

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

TM221ME16T controller M IO transistor PNP Ethernet

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

TM221M32TK controller M IO transistor PNP

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

Installation & Configuration manual. InduBox GSM IV

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

LMC058LF42 compact base - 42 I/O - 24 V DC supply

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

Transcription:

Data Sheet Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and date for the RTU. The time can be set and synchronized from the central system via the serial lines or via the Ethernet LAN interface (SNTP). Application The 560CMD11 is the Communication Unit (CMU) of the DIN rail RTU540. The 560CMD11 consists of a metal DIN rail Housing, which includes a CPU and a Power Supply (PSU). The essential tasks of the 560CMD11 are: Managing and controlling of the RTU211 I/O modules via the 10 pole Wired-OR- Bus (WRB). Reading Process events from the input boards. Writing commands to the output boards. Communicating with control systems and local MMI systems via the 4 integrated serial line interfaces and the 2 Ethernet 10/100 BaseT LAN interfaces. Managing the time base for the RTU540 station and synchronizing the I/O modules. Handling the dialogue between RTU540 and Web-Browser via the Ethernet interface. Communication via integrated GPRS- Modem (only R0011) Characteristics The two microprocessors are the essential hardware parts of the board, which share themselves in the tasks: MPU: 32 Bit Main Processing Unit SLC: 8 Bit Serial Line Controller Figure 1: Function block diagram 560CMD11 The control unit stores configuration files power fail save in a removable Compact Flash memory card. That allows the 560CMD11 to have valid configuration data after power on and 560CMD11 will be available again after a short initialization. The serial communication interfaces Communication Port CP1 Communication Port CP2 Communication Port CPA Communication Port CPB are designed for RS232C and RS485 standard and can be parameterized by software. The interfaces E1 and E2 are based for the Ethernet standard 10BaseT/100BaseT. The connectors of the serial and Ethernet communication interfaces are provided as RJ45 jacks integrated in the board's front plate. Doc.-No.: 1KGT 150 764 V007 1 1

The 560CMD11 serial peripheral bus (I/O- Interface/ Wired-OR-Bus ) is connected via 20- pole pluggable connector. The 560CMD11 R0011 provides a radio interface via an integrated Quad-Band GSM/GPRS modem. For communication via the GSM/GPRS modem a pluggable SIM-Card is necessary. At the housing an antenna or antenna cable can be connected via connector RF (see Figure 2) 560CMD11 indicates operational and error states by light emitting diodes on the front plate (see Figure 3). The exact definition for the LED has to be taken from the functional description of the RTU500 series releases. ERR (1x) red Error / Warning Tx (4x) green Transmit data, communication ports 1, 2, A, B Rx (4x) green Receive data, communication ports 1, 2, A, B Act (2x) green Ethernet activity Lnk (2x) yellow Ethernet link IO-Bus (1x) green Wired-OR-Bus activity PF (1x) red One of the output voltage is fail RUN (1x) green The CMU is reachable via Ethernet RUN (1x) yellow Firmware is running but not reachable via Ethernet Def. IP (1x) red The default IPaddress is active GPRS (1x) green Communication via GPRS modem Table 1: Description LEDs Due to different handling of the connection startup with different GPRS providers we recommend a test installation before a rollout of 560MDD10/ 560CMD11 R0011 devices. Doc.-No.: 1KGT 150 764 V007 1 2

Fig 2: Top side of 560CMD11 R0011 housing (with antenna connector RF) Fig 3: Front side 560CMD11 R0011 housing Fig 4: Bottom side of 560CMD11 R0011 housing Doc.-No.: 1KGT 150 764 V007 1 3

Technical Data In addition to the RTU500 series general technical data, the following applies: Main Processing Unit MPU Microprocessor RAM Flash Memory ELAN520 @ 133 MHz (incorporating an Intel 586 TM class 32 bit processor) 64 MByte Serial Line Controller SLC Controller Type RAM Dual Ported RAM 128 MByte (Compact- Flash) 80C251 32 kbyte 16 kbyte Serial Interfaces 1 and 2 Physical Interface Bit rate Signal lines RS232C Serial Interface A and B Physical Interface Bit rate Signal lines RS485 RS232C / RS485 selectable by software 38 400 bit/s GND E2/102 TxD D1/103 RyD D2/104 RTS S2/105 CTS M2/106 DTR S1.2/108 DCD M5/109 RS485 / RS232C selectable by software 19 200 bit/s G Signal ground A Receive/Transmit B Receive/Transmit GSM/GPRS modem (only R0011) Frequency GPRS Class 10 SIM Card Interface GSM 850MHz max. 2Watt transmitting power E-GSM 900MHz max. 2Watt transmitting power DCS 1800MHz max. 1Watt transmitting power PCS 1900MHz max. 1Watt transmitting power ID-000 50 SMA-RF connector (female) Power consumption of the 560CMD11 (without powered IO-bus interface) 24 V DC 300 ma (R0001) 380 ma (R0011 DC Input 24 V DC Tolerance Range -15... +20 % Max. Current 2.8 A @ 24 V DC Starting Current: Efficiency: Reverse voltage protection Internal Output 1 < 1, 1.5 m sec (Class S1) according IEC 60870-4 88 % @ 24 V DC yes 5.0 V DC Tolerance: ± 5 % Ethernet LAN Interface E1 and E2 Physical Interface 10BaseT/100BaseT Bit rate 10/100 MBit/s 1 A 100 mv ss Doc.-No.: 1KGT 150 764 V007 1 4

Internal Output 2 ± 15 V DC Tolerance: ± 5 % Internal Output 3 0,5 A 200 mv ss 18 V DC Tolerance: ± 5 % 1 A 200 mv ss DC Output (It is not allowed for the process supply) 24 V DC Tolerance: -15 % +20 % Mechanical Layout Metal Housing Height Weight Connector Types Power Supply IO- Interface Wirde- OR- Interface Ethernet Interface E1 and E2 Serial Interfaces 1, 2 and A, B 500m A 200 mv ss 204 x 105 mm 55 mm Approx. 0.5 kg 2 x 3 pole pluggable screw terminals 1 x 20- pole Pluggable connectors RJ45 jack, 8 pole RJ45 jack, 8 pole Electromagnetic Compatibility EN61000-4-2 Electrostatic Discharge Immunity EN61000-4-3 Radiated RF Field EN61000-4-4 Fast Transient Immunity (Burst) EN61000-4-5 Surge Immunity EN61000-4-6 Conducted RF Field EN55011 RF emmisions air EN55011 RF emmisions cable 8KV Air 6KV direct 10V/m 2KV/4KV 2KV/4KV 10V 30MHz up to 1GHz class A (Industry) 0,01 MHz up to 30 MHz class A (Industry) Environmental Compatibility EN60068-2 EN60068-2-1 EN60068-2- 1 Start up Test EN60068-2-14 EN60068-2-30 IEC60255-21-3 Seismic Test IEC60255-21-1 Vibration Test IEC60870-2-2 Vibration durance test IEC60255-21-2 Schock Test IEC60870-2-1 Schock Test IEC60255-21-2 Bump Test 70 C 96h fully active loaded -25 C 96h fully active loaded -40 C System starts on -40 C 0 C /70 C Temperature cycles 48h, fully active loaded 70 C/95% rel. Humidity Storage, not activ Class 1 Class 1 Class Bm 15g, Class 1 25g, Class 1 10g, Class 1 Doc.-No.: 1KGT 150 764 V007 1 5

Electrical Safety EN60950-1 Safety class 1 Environmental Conditions Electrical Safety investigation Flamability investigation Temperatur -40 C start up -25 C +70 C operation -40 C +85 C storage IP class IP 30 Relative humidity 5 95 % (non condensing) Ordering Information 560CMD11 R0001 560CMD11 R0011 Bar (dipole) antenna 560ANA01 Wall-mount antenna connected by a 5m long coaxial cable 560ANA02 Extension cable for wall mounted GPRS antenna 560ANA02 560CAB02 1KGT023400R0001 1KGT023400R0011 1KGT023600R0001 1KGT023700R0005 1KGT033800R0015 Antenna Data 560ANA01 Bar antenna Gain 2,2 dbi Size 54mm x 6,7mm x 9,65mm Connector SMA Male 560ANA02 (5m) Wall-Mount antenna with cable Gain 2,2 dbi Size Dimensions (H x L x B / W x Ø) 370mm x 155mm x 36mm x 16mm Cable type RG58 Cable length 4950 + 100mm Protection IP66 Class Weight 420g 560CAB02 extension cable for wall mounted GPRS antenna Cable type RG58 Cable length 15m Doc.-No.: 1KGT 150 764 V007 1 6

Data Sheet Communication Unit 560CMD11 Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2013 ABB All rights reserved Doc.-No.: 1KGT 150 764 V007 1 7