Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

Similar documents
GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

GV204 Impulse Splitter for Incremental Encoders

GV470 / GV471 Impulse splitters for incremental encoders - with 4 or 8 output channels

GV460 / GV461 and GV480 / GV481 Pulse splitters for incremental encoders - with simple or complete potential separation

LW217 / LW218 Optical fiber modules for transmission of SSI encoders and measuring systems

MC800 Universal Motion Controller

Series ID / IA / IR Dual position and differential indicators for use with two encoders or measuring systems (SSI absolute or incremental)

Legal notices: Sd340_02h_oi_e.doc / Apr-16 Page 2 / 64

Operating Instructions

Operating Manual. BY340 / BY641 High performance low cost synchronous controllers for one slave axis

Operating Manual. DX345, DX346, DX347 and DX348 Multifunction Indicators with Pulse Inputs

Operating Manual. FM260 Impulse and Frequency Multiplier for use with Incremental Encoders and Sensors

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Speed monitor D / / 2014

OPERATING INSTRUCTIONS

FEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)

GS202 Encoder Switch

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating Manual. Monitor for speed, standstill and direction of rotation. DZ260, DZ261, DZ266, DZ267 und DZ269

2-Axis Counter BDD 622

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

Operating Manual RISH DPM Hz

PanelView Plus/VersaView CE Terminals and Display Modules

531K. Process Display Temperature display for Pt100 and Ni100 RTD's. Installation and Operating Manual

Operating instructions Monitor FD-2 DR2005 DR / / 2007

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

CPCI-PS24 24V-Power Supply

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

V E1B Snap-in I/O Module

Conductive Level Controller

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Operating Instructions Differential Pressure Transducer PS27

FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code

DIGITAL PANEL THERMOMETER

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

V E1B Snap-in I/O Module

V E2B Snap-in I/O Module

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

User safety and equipment protection guidelines

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Operating instructions. Monitor FD / / 2013

Product and functional description

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Push Button Interface UP 220D31

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

INDICATOR FOR PROCESS CONTROL. Love Controls. LCI108J-0x INSTRUCTION MANUAL. EDITION: January Valid for models with software version P-1

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

S82S (3/7.5-W Models)

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

Switch Mode Power Supply S8VT 120/240/480/960 W Models

EWCH 485 Electronic Pulse Counter

CMC III Universal Sensor

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

User Manual Digital Input Module

Geräte-Handbuch Device manual Notice pour utilisateurs

2016 SIGLENT TECHNOLOGIES CO.,LTD

Absolute Encoders Multiturn

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

Z10 SN N Installation Manual Battery operated Length Measuring Unit

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

S8VE (60/90/120/180/240-W Models)

Product and functional description

Solid-state Timer H3YN

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

TA18 active subwoofer. user manual

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

PHOENIX CONTACT - 07/2006

02/11/2015

DALI Professional Controller-4. Control unit Operating instructions

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

MDM 011-Z1 Regen Resistor

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

DIGITAL DISPLAY. for Industry Applications. Serie REX-D. Key-Features:

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Quick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide

TRC-190 User s Manual

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

2-Way Wireless I/O Expander Installation Guide

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

CMC III Temperature/Humidity Sensor

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Transcription:

Operating Manual ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz Product Features: Miniature panel housing Bright LED display with 6 digits Add-on frame for clip or screw mounting Counting frequency 15 to 60 khz (depends on counting mode) Selectable filter for use with mechanical inputs Adjustable scaling factor and divider Protection class IP65 (front side) Diverse counting modes (e. g. event, difference, summing or position) Easy to set up by menu support 10 to 30 VDC power supply motrona GmbH, Zeppelinstraße 16, DE - 78244 Gottmadingen, Tel. +49 (0) 7731 9332-0, Fax +49 (0) 7731 9332-30, info@motrona.com, www.motrona.com

Version: Description: Zx02001b/K/hk/Jan02 valid for models before august, 2006 Zx02002a/K/hk/Dec06 60 khz, Divider, (x4), summing mode ZX02002b/hk/Aug07 modification of temperature range Zx02002c/ag/March15 - power down memory removed from the features on page 1 - new design, techn. specifications and safety instructions Zx020_02d/ag/July15 - Chapter 2. updated (setup procedure has been changed) - Legal Notices supplemented Zx020_02e/ag Correction of the temperature range Legal notices: All contents included in this manual are protected by the terms of use and copyrights of motrona GmbH. Any reproduction, modification, usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH. Table of Contents 1. Safety Instructions and Responsibility... 3 1.1. General Safety Instructions... 3 1.2. Use according to the intended purpose... 3 1.3. Installation... 4 1.4. Cleaning, Maintenance and Service Notes... 4 2. Front Key Operation... 5 2.1. Enter the Setup Mode... 5 2.2. Parameter Settings... 5 3. Operational parameters... 6 3.1. Input polarity... 6 3.2. Input filter... 6 3.3. Input Mode of count impulses... 6 3.4. Impulse scaling factor... 7 3.5. Decimal point... 7 3.6. Set/Reset mode... 7 3.7. Set point... 8 3.8. End of program... 8 4. Terminal Assignments... 9 5. Delivery includes:... 9 6. Technical Specifications... 10 7. Dimensions... 11 7.1. Mounting without use of add-on frames... 11 7.2. Bezel 50 x 25 mm (1.969 x 0.984 ) for clip mounting... 11 7.3. Bezel 50 x 25 mm (1.969 x 0.984 ) for screw mounting... 11 Zx020_02e_oi_e.doc / Apr-16 Page 2 / 11

1. Safety Instructions and Responsibility 1.1. General Safety Instructions This operation manual is a significant component of the unit and includes important rules and hints about the installation, function and usage. Non-observance can result in damage and/or impairment of the functions to the unit or the machine or even in injury to persons using the equipment! Please read the following instructions carefully before operating the device and observe all safety and warning instructions! Keep the manual for later use. A pertinent qualification of the respective staff is a fundamental requirement in order to use these manual. The unit must be installed, connected and put into operation by a qualified electrician. Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property and for consequential damage, due to incorrect handling, installation and operation. Further claims, due to errors in the operation manual as well as misinterpretations are excluded from liability. In addition the manufacturer reserve the right to modify the hardware, software or operation manual at any time and without prior notice. Therefore, there might be minor differences between the unit and the descriptions in operation manual. The raiser respectively positioner is exclusively responsible for the safety of the system and equipment where the unit will be integrated. During installation or maintenance all general and also all country- and application-specific safety rules and standards must be observed. If the device is used in processes, where a failure or faulty operation could damage the system or injure persons, appropriate precautions to avoid such consequences must be taken. 1.2. Use according to the intended purpose The unit is intended exclusively for use in industrial machines, constructions and systems. Nonconforming usage does not correspond to the provisions and lies within the sole responsibility of the user. The manufacturer is not liable for damages which has arisen through unsuitable and improper use. Please note that device may only be installed in proper form and used in a technically perfect condition in accordance to the Technical Specifications (see chapter 6). The device is not suitable for operation in explosion-proof areas or areas which are excluded by the EN 61010-1 standard. Zx020_02e_oi_e.doc / Apr-16 Page 3 / 11

1.3. Installation The device is only allowed to be installed and operated within the permissible temperature range. Please ensure an adequate ventilation and avoid all direct contact between the device and hot or aggressive gases and liquids. Before installation or maintenance, the unit must be disconnected from all voltage-sources. Further it must be ensured that no danger can arise by touching the disconnected voltagesources. Devices which are supplied by AC-voltages, must be connected exclusively by switches, respectively circuit-breakers with the low voltage network. The switch or circuit-breaker must be placed as near as possible to the device and further indicated as separator. Incoming as well as outgoing wires and wires for extra low voltages (ELV) must be separated from dangerous electrical cables (SELV circuits) by using a double resp. increased isolation. All selected wires and isolations must be conform to the provided voltage- and temperatureranges. Further all country- and application-specific standards, which are relevant for structure, form and quality of the wires, must be ensured. Indications about the permissible wire crosssections for wiring are described in the Technical Specifications (see chapter 6). Before first start-up it must be ensured that all connections and wires are firmly seated and secured in the screw terminals. All (inclusively unused) terminals must be fastened by turning the relevant screws clockwise up to the stop. Overvoltages at the connections must be limited to values in accordance to the overvoltage category II. For placement, wiring, environmental conditions as well as shielding and earthing/grounding of the supply lines the general standards of industrial automation industry and the specific shielding instructions of the manufacturer are valid. Please find all respective hints and rules on www.motrona.com/download.html --> [General EMC Rules for Wiring, Screening and Earthing]. 1.4. Cleaning, Maintenance and Service Notes To clean the front of the unit please use only a slightly damp (not wet!), soft cloth. For the rear no cleaning is necessary. For an unscheduled, individual cleaning of the rear the maintenance staff or assembler is self-responsible. During normal operation no maintenance is necessary. In case of unexpected problems, failures or malfunctions the device must be shipped for back to the manufacturer for checking, adjustment and reparation (if necessary). Unauthorized opening and repairing can have negative effects or failures to the protection-measures of the unit. Zx020_02e_oi_e.doc / Apr-16 Page 4 / 11

2. Front Key Operation 2.1. Enter the Setup Mode There are two different ways to enter the setup mode: a) keep both front keys pressed when powering on b) keep both front keys pressed for 5 seconds, if the power is already on 2.2. Parameter Settings With an activated setup mode, the display shows: After releasing the keys, the display shows: In order to cancel the setup hold the left key pressed and additionally press the right one By pressing the right key, the display changes to: To jump into the first parameter, hold the left key pressed and additionally press the right one After releasing the keys, the display alternates between the parameter title and the setting of the parameter. After pressing any key, only the parameter value for setting is displayed. Press the right key, to jump into the next parameter. For numerical inputs select the decade with the left key and change the value by the right one To jump into the next parameter, hold the left key pressed and additionally press the right one After reaching the last menu item Endpro, two selections can be done: Yes : will store all new entries, before the unit automatically switches to normal operation. No : will repeat the setup routine. The latest values will remain without saving and can be checked or modified before they are permanently stored. Zx020_02e_oi_e.doc / Apr-16 Page 5 / 11

3. Operational parameters Please enter all of the subsequent parameters, as explained in section 2. 3.1. Input polarity InpoL npn NPN: All inputs must switch to 0 PnP PNP: All inputs must switch to +. For Namur: Set to NPN, see chapter 4. 3.2. Input filter Filter Off on Filter off: Counting frequency up to 60 khz see Technical Specifications (chapter 6) Filter on. Maximum counting frequency 30 Hz 3.3. Input Mode of count impulses Input Cnt.dir Up.dn Input A: Count input Input B: Direction select up/down Differential: Input A: increments Input B: decrements Summing: Input A: increments Input B: increments Quad Quadrature up/down for signals A/B, 2 x 90 Counts rising edge of input A Quad 2 Quad 4 Similar to quad, but with impulse doubling. Counts rising and falling edges of input A Similar to quad, but with impulse quadrupling. Counts all edges of inputs A and B Zx020_02e_oi_e.doc / Apr-16 Page 6 / 11

3.4. Impulse scaling factor Factor 00.0001 Multiplies the input pulses with the factor set. 99.9999 Setting range 0.0001 to 99.9999. Setting 0 will not be accepted. Divider 00.0001 Divides the input pulses by the divider set. 99.9999 Setting range 0.0001 to 99.9999. Setting 0 will not be accepted. 3.5. Decimal point dp 0 Sets the decimal point of the display. 0.000 (Max. 3 decimal places) 3.6. Set/Reset mode resmd Man.el No res El res Manre Manual Set/ Reset function by the red front key and electrical Set/ Reset by the rear input. All Set/ Reset functions disabled. Electrical Set/ Reset only by input Reset. Manual Set/ Reset only by the red front key. Zx020_02e_oi_e.doc / Apr-16 Page 7 / 11

3.7. Set point Setpt -199999 Upon a Set/ Reset command, the counter sets to the value entered here. 99.9999 Range -199 999...999 999. 3.8. End of program Endpro No Yes Select No to return to the beginning of the menu for verification of settings. Select Yes to store data and exit the menu. Zx020_02e_oi_e.doc / Apr-16 Page 8 / 11

4. Terminal Assignments (also printed to the top of the unit) 5. Delivery includes: Panel mounting clip Bezel for screw mounting with panel cut out 50 x 25 mm Bezel for clip mounting with panel cut out 50 x 25 mm Sealing Zx020_02e_oi_e.doc / Apr-16 Page 9 / 11

6. Technical Specifications Power supply: Input voltage: Protection circuit: Consumption: 10 30 VDC reverse polarity protection max. 50 ma Connections: Type of connection screw terminal, 1.5 mm² / AWG 16 Incremental input: Power down memory: Display: Housing: Ambient temperature: Conformity & standards: Characteristic: Switching levels: Channels: Counting frequency: Pulse form: Internal resistance: Pulse time (set/reset): Data retention: Storage Cycles: Type: Digit height: Range: Material: Mounting: Dimensions: Miscellaneous: Protection class: Weight: Operation: Storage: EMC 2004/108/EC: RoHS 2011/65/EU: NPN / PNP / Namur LOW: 0 V 0.2 x power supply voltage HIGH: 0.6 x power supply voltage 30 V A, B and Set/Reset 15 60 khz (depends on selected counting mode) arbitrary (Schmitt-Trigger) Ri 10 kohm min. 5 ms 10 years 10 6 6 digit LED, red 8 mm / 0.3149 inch -199999 999999 plastic panel cut out (w x h): 45 x 22 mm resp. 1.772 x 0.866 inch outer dimensions (w x h x d): 48 x 24 x 59 mm resp. 1.889 x 0.9449 x 2.323 inch additional bezels for clip or screw mounting are included in the delivery front: IP 65 / rear: IP20 approx. 50 g -20... + 55 C / -4... 131 F (not condensing) -25... + 70 C / -13... 158 F (not condensing) EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 EN 50581 Maximum counting frequency with respect to operating mode and power supply: Mode Power supply 24 VDC Power supply 12 VDC CntDir 60 khz 20 khz Up-Down 25 khz 15 khz Up-Up 25 khz 15 khz Quad 25 khz 15 khz Quad2 25 khz 15 khz Quad4 15 khz 15 khz Zx020_02e_oi_e.doc / Apr-16 Page 10 / 11

7. Dimensions 7.1. Mounting without use of add-on frames max. 19.3 max. 0.7 6 22 x45 24,0 (.945 ) 22,2 ( +0,3) 0.874 (+ 0.012) 48,0 (1.890 ) 59,0 (2.323 ) 4,0 (0.157 ) 6,5 (0.256 ) 45,0 (+0,6) 1.772 (+ 0.024 ) 7.2. Bezel 50 x 25 mm (1.969 x 0.984 ) for clip mounting 26,0 (1.024 ) 25,0 x 50, 0 (0.984 x 1.969 ) 25,0 +0,5 0.984 +0.020 40,0 (1.575 ) 32,0 (1.260 ) 25,0 x 50,0 (0.984 x 1.969 ) 25,0 +0,5 0.984 +0.020 32,0 + 0,1 (1. 260 +0.004) 53,0 (2.087 ) 1,0 (0.039 ) 4,0 (0.157 ) 50,0 +0,6 (1.969 +0.024 ) 7.3. Bezel 50 x 25 mm (1.969 x 0.984 ) for screw mounting A A= Senkung Af3, DIN 74 Counterbore Af3, DIN 74 M3 A 56,0 (2.205 ) 1,0 (0.039 ) 4,0 (0.157 ) M3 50,0 +0,6 (1.969 +0.0 24 ) Zx020_02e_oi_e.doc / Apr-16 Page 11 / 11