Communication Controller CC-Link/CPL Converter CMC10A

Similar documents
Control Motor ECM3000

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

Distributed Multi-Channel Controller DMC10

Network Instrumentation Modules NX Digital Output Modules NX-DY1/DY2

HPV Series. Vane Type Photoelectric Sensors with Integrated General-use Amplifier. Specifications. click FEATURES TYPICAL APPLICATIONS

MODEL: GR8-EM. Communication Adaptor GR8 Series

V-3000 Series Miniature Basic Switches

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Safety Monitoring Relays

SYSMAC Remote Transistor Module

FX-485PC-IF RS485 Interface Unit Hardware Manual

TABLE OF CONTENTS. Communication Functions

Tecnología en Electrónica y Control SRL Ficha Técnica

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

AD-8923-CC. Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD B

RS232C/RS485 Data can be easily monitored by LAN

Single Loop Controller SDC15

MG50-CL MG51. Instruction Manual. CC-Link Interface unit Main module. Distribution module

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

1) Indicates that the identified danger WILL cause physical and property damage.

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Model Number Structure

Safety Relay Unit (I/O Unit Type)

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

SER-4485-SI-M USER S MANUAL

Model Number Structure

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

MGate 4101-MB-PBS Series

1.5 axis motion controller

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

8 Channel USB to RS485/422 Converter USB-402 User s Manual Ver. 1.0 HuMANDATA LTD.

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Communications & Networking

Enhanced communication

SRT2-ROC08, SRT2-ROC16

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Model Number Structure

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

MODEL: R1M-GH. PC Recorders R1M Series

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

11 PROFIBUS Fieldbus Connector

Programmable Relay ZEN V2 Units

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

Inductive Proximity Sensor

Model Number Structure

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Terminal block 2 A 5 X 3. Specification

EX120/121/122 Series Some protocols are not CE-compliant.

For Output. Series EX120/121/122. Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks

Industrial Control Relays Relays and terminal module RS type

ECM3000. Control Motor

Optimum sensing capability for LCD manufacturing

Making Hazardous Operations Safe and Productive

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

EtherCAT Remote I/O Terminal GX series

EX-RC1 Remote I/O Adapter

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

DIGITAL INDICATING CONTROLLER

T1K MODBUS Base Controller Specifications

Temperature Controller E5C4

Switching Power Supply

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

EX-RC1 Remote I/O Adapter

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

HART NETWORK UNIT (HNU)

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

Varistor installation. Input logic. Voltage of relay coil

2. Actuator B: Ball type P: Pin type F: Flat type

EX-RC1 Remote I/O Adapter

Single Loop Controller Model R15

Energy Management BUS Adapter Type VMU-B 01

INSTRUCTION SHEET. Eaton Logic Controller DeviceNet Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CADNET

PRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

PRODUCT SPECIFICATION. PC Board Relays. Series.

Energy Management BUS Adapter Type VMU-B

7-4-2 CP1W-MAD11/CPM1A-MAD11 Analog I/O Units

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept

Communications & Networking

Transcription:

No. CP SS 1766E Communication Controller CC-Link/CPL Converter CMC10A The communication controller CMC10A is a converter designed for the communication between Yamatake's digital indicating controller and Mitsubishi Electric's CC-Link without use of programs. Use of the CMC10A makes it possible to automatically collect the data from the digital indicating controllers connected to the slave communication and to always refresh the data between the CC-Link master unit and CMC10A. As a result, the software programming load is greatly reduced. Features Program communication with Mitsubishi Electric's CC-Link can be performed. One CMC10A unit can communicate with up to 16 digital indicating controllers. PLC ladder software developing load is greatly reduced. The CMC10A automatically collects the data from the digital indicating controllers connected to the slave communication. Additionally, the data between the CMC10A and CC-Link master unit is always refreshed. Therefore, when a communication system is constructed through CC-Link, the communication can be performed only using several program steps, greatly reduced when compared to the ladder program of the computer link unit (approx. 2000 steps). Setup operation can be made with generally available communication software. The setup of the CMC10A does not require any special application software and can be made with generally available communication software (TTY procedure). Compact body The outside dimensions of the CMC10A are only 30 100 105 mm. Additionally, the CMC10A is so designed that it can be mounted on the DIN rail, ensuring easy mounting. * CC-Link is an abbreviation of Control & Communication Link, Mitsubishi Electric's field network. Example of connection Mitsubishi Electric's PLC CC-Link interface module CC-Link applicable unit Special cable CPL communication line Up to 16 units Yamatake's digital indicating controller Character terminal or Personal computer with general software 1

Communica- CC-Link Note (1) Communication method Broadcast polling method tions (HOST CMC) Synchronization method Frame synchronization Transmission line type Transmission speed Station type Number of occupied stations Model type Bus type (RS-485 compatible: 3-wire system) 10M/5M/2.5M/625K/156K bps Remote device station 4 stations are occupied. Temperature controller (Temperature controller 8-ch type or temperature controller 16-ch type can be selected using the setup.) 1 to 64 (Start station No. ranging from 1 to 61 is set.) Transmission 10m 5m 2.5m 625K 156K speed Total extension 100m 150m 200m 600m 1200m distance Units satisfying the following formulas (1) and (2) can be connected. Remote station No. Maximum transmission distance Note (2) (examples of maximum transmission distances with use of cable FANC-SB) Number of connection units (1 x a) + (2 x b) + (3 x c) + (4 x d) 64... (1) a: Number of units occupying station 1, b: Number of units occupying station 2 c: Number of units occupying station 3, d: Number of units occupying station 4 (16 x A) + (54 x B) + (88 x C) 2304... (2) A: Number of units occupying station 1, B: Number of units occupying station 2 C: Number of units occupying station 3, D: Number of units occupying station 4 For example, when only the CMC10A is connected, up to 16 units can be connected. Connection cable Special CC-Link cable Terminating resistor (3) Terminating resistor unit (optional unit) 110Ω: 81446717-001(2 pcs./set) 130Ω: 81446717-002 (2 pcs./set) Connection connector Model No. 81440792-001 (4 pcs./set, optional unit) Note (1) CC-Link is an abbreviation of Control & Communication Link. For details about CC-Link specifications, see the User's Manual for CC-Link system master local unit published by Mitsubishi Electric. Note (2) In the CC-Link, the specifications of the maximum transmission distance may vary depending on the cable type, transmission speed, total number of remote units, minimum distance between stations, and/or system configuration. For details, see Mitsubishi Electric's sequencer technical news No. PLC-D-330. Note (3) In the CC-Link, the specifications of the terminating resistor may vary depending on the cable type. For details, see Mitsubishi Electric's sequencer technical news No. PLC-D-330. CPL communications Communication method Half duplex method (CMC LOCAL) Synchronization method Start-stop synchronization Transmission line type Bus type (RS-485 compatible: 3-wire system) Transmission speed 9600 bps Transmission distance Up to 500m Number of connection Up to 16 units (Up to 8 units when using temperature controller 8-ch type) units Data format 8 data bits, 1 stop bit, even parity Communication address 1 to 127 (LOCAL station address) Connection applicable C10-series, C20/21-series, C30/31-series and C40A series (standard models model) Models with optional RS-485 communication of each model-series Loader communications Communication method Half duplex method (CMC PC) Synchronization method Start-stop synchronization Transmission line type Control method Transmission speed Data format Special cable 81440793-001 (optional unit) is used. Non-procedure (TTY procedure) 9600 bps 8 data bits, 1 stop bit, even parity 2

General Rated power voltage 24Vdc specifications Operating power voltage 21.6 to 26.4Vdc Power consumption Insulation resistance Dielectric strength Isolation 5W (under operating conditions) 50MΩ or more when measured using 500Vdc-Megger (between case or grounding terminal and power terminal) 500Vac for 1 min. (between case or grounding terminal and power terminal) Grounding/Shield terminal (CC-Link connection connector) CC-Link communication Loader communication Digital circuit CPL communication Grounding terminal (Base) Power supply circuit Operating conditions Ambient temperature 0 to 50 C Ambient humidity 30 to 90%RH Transport/Storage Ambient storage temperature 20 to +70 C conditions Ambient storage humidity 10 to 90%RH Vibration resistance 4.9m/s 2 or less Package drop test: Drop height 60 cm free fall Screw tightening torque Connector for CC-Link Terminal part: 0.8 N m connection Mounting part: 0.8 N m Power supply and CPL 0.8 to 1 N m communication terminals Mounting Screw mounting or DIN rail mounting Mask/Case Mask/Case materials Mask: Polycarbonate, Case: Polycarbonate, Base: Polycarbonate Mass Mask/Case color 300g Mask: Navy blue, Case: Light gray, Base: Light gray Solid line: Isolated. Dotted line: Not isolated. Optional units Unit name Model No. Contents (separately sold units) Connector set 81440792-001 Connector set for CC-Link connection (4 pcs./set) Special cable 81440793-001 Special cable for loader communication (1 set/set) (Jack D-SUB 25-pin, D-SUB 25-pin 9-pin) Terminating resistor unit (110Ω) 81446717-001 110Ω terminating resistor unit (2 pcs./set) Terminating resistor unit (130Ω) 81446717-002 130Ω terminating resistor unit (2 pcs./set) Model selection guige I II III IV V Example: CMC10ACL1A000 I II III IV V Basic model Additional No. Application Mounting Option Contents CMC10 Communication controller A Additional No. CL1 Applicable to CC-Link A Left and right base connectors provided. 000 None 3

0 12 3 4 5 6 7 8 9 Terminal/Connector connections Body LOADER jack : Special cable 81440793-001 (optional unit) is connected to set up the CMC10A. The set contents become valid after the RESET switch is pressed or the power is turned OFF, and then it is turned ON again. CC-Link station No. setup switch : The CMC10A is a type of 4-station occupy unit. Set the start station No. The setting range is 1 to 61. (factory setting: 00) CC-Link transmission speed setup switch Position Transmission speed 0 156Kbps 1 625Kbps 2 2.5Mbps 3 5Mbps 4 10Mbps (factory setting: 0) Connector for CC-Link connection Position Signal name 11 DA 12 DB 13 DG 14 SLD 15 FG CMC ADDRESS 0 12 3 45 6 12 3 4 LOADER POWER L RUN X1 HOST OMC B.RATE L ERR 11 12 13 14 15 X10 ERR HOST CMC CMC LOCAL RESET CMC10 Indicators: Indicate the operating state of the CMC10A POWER: Lit when the power is ON. L RUN L ERR ERR RESET switch: Resets the CMC10A. Indicate the operating state of the CC-Link. Indicate the operating state of the slave communication. Indicates if an error occurs in the CMC10A. Connecting the CC-Link CC-Link is connected using a connector. Applicable connector is 81440792-001 (4 pcs./set). DA 11 DB 12 DG 13 SLD 14 15 FG Control and Communication Link DA DB DG Shield Base Connecting the power supply Connect the power terminal as follows: 1 2 3 Communications disconnection switch : Used for disabling CPL communications with devices linked on the left side (factory setting: CONNECT ) Mounting hole DIN rail stopper: Used for securing on a DIN rail Power supply terminal No. Signal 1 24Vdc (+) 2 24Vdc ( ) 3 FG CPL communications terminal: 3-wire RS-485 connector terminal No. Signal 4 DA 5 DB 6 SG 24Vdc±10% FG Connecting CPL communications CPL communications (RS-485) is performed using a 3-wire connection. 4 5 6 DA DB SG CPL (RS-485) 4

External Dimensions Body/Base 8 30 10.5 105 (unit: mm) (9) 100 5 32.3 Dimension required for mounting and removal from DIN rail Dimension required for mounting and removal of the body (40) Dimensions for screw mounting M3 (30) 5 10 0.2 30 0.9 0.3 5 Secure two mounting holes in the base using the M3 screws. (100) 78.5 0.2 5

RESTRICTIONS ON USE This product has been designed, developed and manufactured for general-purpose application in machinery and equipment. Accordingly, when used in the applications outlined below, special care should be taken to implement a fail-safe and/or redundant design concept as well as a periodic maintenance program. Safety devices for plant worker protection Start/stop control devices for transportation and material handling machines Aeronautical/aerospace machines Control devices for nuclear reactors Never use this product in applications where human safety may be put at risk. Specifications are subject to change without notice. Advanced Automation Company 1-12-2 Kawana Fujisawa Kanagawa 251-8522 Japan URL:http://www.azbil.com Printed in Japan. (H) 1st Edition: Issued in Jan., 2003 6 No part of this publication may be reproduced or duplicated without the prior written permission of Yamatake Corporation.