FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code

Similar documents
FEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)

Series BDF Serial ASCII

FEMA ELECTRÓNICA. Panel meter for process signals in ma and Vdc. Accepts both active and passive

Panel Meters Series M40 Model M40-A Amplicon.co m IT and Instrumentation for industry

Series K. K40-RTU. Display for Modbus RTU protocol. User s Manual. Tel. (+34)

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

SIGNAL CONVERTERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY. Small catalogue. Tel. (+34)

Series M. M40-P. Meter for process signals. User s Manual. Tel. (+34)

1-36V, 0-3A DC Power Supply

User's Guide. Model High Precision Quad Output DC Power Supply

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

MODEL 805 USER MANUAL

SLA Battery Capacity Analyzer

Operating Manual RISH DPM Hz

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

High Precision Quad Output DC Power Supply

Quick Start Guide and Health and Safety Information

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2

INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT

Hoist Controller for Direct Voltage Hoist Instruction Manual

Hoist Controller for Low Voltage Hoist Instruction Manual

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

Temperature and humidity electronic data loggers, 4 channels, according to European Standard EN 12830

Hoist Controller for Low Voltage Hoist Instruction Manual

Tempco Instruction Manual

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

User's Guide. Phase Sequence and Motor Rotation Tester Model

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

MAXIMA+ Series Rotary Level Indicator

Hoist Controller for Low Voltage Hoist

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

MAXIMA + Series ROTARY LEVEL CONTROL

DST8-DIN 8-way DMX Splitter Instruction Manual

PanelView Plus/VersaView CE Terminals and Display Modules

SP6R Level Controller Operation Manual

CMSA-100 Manual. Cinema Media Server Automation

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Conductive Level Controller

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

Installing the Tracer MP503 Input/Output Module Ordering number: ,

DIGITAL PANEL THERMOMETER

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

ESM H 77x35 DIN Size Heating Controller Digital, ON / OFF Temperature Controller

GUIDE PROGRAMMABLE PANEL METER M905

CPA 40 Two Channel Amplifier

700 Series 200 Amp Clamp Meters

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

1 Channel Strobe Controller ORDERCODE 40226

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Manual Control Unit GFC 32

Model 7026 (1x32) 2-wire Multiplexer

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

User's Guide. Extech AM A AC Analog Clamp Meter

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

PCT2000. User Manual. Precision current transducer 2000 A

Model Channel TTL I/O

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES

Thread length (overall length) material

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

MTP INSTRUCTION MANUAL

Thermoelectric Cooler Controller TED1000

IGLOO IGLOO EASY INSTRUCTION MANUAL

VersaMax IP I/O Module

ELV12 Series. Instruction Manual

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

INDICATOR FOR PROCESS CONTROL. Love Controls. LCI108J-0x INSTRUCTION MANUAL. EDITION: January Valid for models with software version P-1

Fiber optic converter audio and CAN TA OPERATION MANUAL

LED Par 64 Short DMX ORDERCODE 42431

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Manual Simatek Control Unit GFC 32

E2Q4 Square Proximity Sensor

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

MC 11 EB-2 Power supply cabinet with external bus, AC version

Series 8000 RF Signal Switch Solution

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Toll Free: Tel: Fax:

User s Guide. 600A AC Clamp Meter. Model 38387

e30v DIGITAL ELECTRONIC THERMOMETER OPERATING INSTRUCTIONS Index

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Transcription:

LARGE DISPLAYS BCD CODE Series BDF LARGE DISPLAYS for parallel BCD code BDF-xx-BCD for parallel BCD code FEMA ELECTRÓNICA IDEAL SOLUTION to display numerical values at long distances, controlled by parallel BCD signal, in 4 and 6 dgits format. Very strong housing and electrically protected units, designed for all type of industrial applications. USER S MANUAL (HT190307-r190307) FEMA ELECTRÓNICA - Page 1

Models BDF for BCD code LARGE DISPLAYS for parallel BCD code The BDF series of large displays for parallel BCD signal is available in 4 and 6 digits format with 57mm or 100mm digit height. Digits are 7 segments in red color (optional green led, ask for information). The display value of each digit is controlled by BCD code. Several paralel lines control all digits (lines ABCD independient for each digit). Control to light the decimal point independent for each digit, control for «HOLD» function to block the refresh of each digit, and control for negative sign (polarity) Function «BLANK» to switch-off all segments and function «TEST» to light all segments. The mechanical of the BDF instruments is a very strong and sturdy aluminium housing anodized in black color, for panel mount, and for wall mount as an option. The front lens is antirreflexive and is firmly inserted on the aluminium profile with a rubber gasket around, providing IP65 protection on the front. The signal wires are connected to plug-in screw clamps for higher security of the connections, accesible at the rear side of the instrument. The power is connected to a 3 terminal plug (2 power connections and 1 earth) containing an integrated protection fuse and an additional fuse as spare part. 0.- ORDERING REFERENCE BDF Size Model Power Color 24 BCD 230 Vac R - Red 26 115 Vac 44 24 Vdc isolated 46 1.- SIZES SIZE BDF-24.- Instrument with 4 digits 57mm digit height SIZE BDF-26.- Instrument with 6 digits 57mm digit height SIZE BDF-44.- Instrument with 4 digits 100mm digit height SIZE BDF-46.- Instrument with 6 digits 100mm digit height FEMA ELECTRÓNICA - Page 2

E D C B A User s Manual - Instrument BDF-xx-BCD 2.- FRONT AND REAR VIEW Connector 2 DIgit1 Negative sign Decimal point Instruments BDF for parallel BCD code are available in 4 or 6 digits format. Digits are led type 7 segments, with decimal point and negative sign. Connector 1 Power (includes fuse) 3.- GENERAL CHARACTERISTICS DISPLAY DIGIT 4 or 6 digits red color Led type 7 segments 57mm (2,3") (BDF-24, BDF-26) 100mm (4,0") (BDF-44, BDF-46) DATA LÓGIC paralel BCD code positive logical level «1» logical level «0» >4,3 Vdc (max. 40 Vdc) <1,1 Vdc. READING FRONTAL DECIMAL POINT selectable HOUSING POWER -9999 to 9999 in 4 digits -999999 to 999999 in 6 digits antirreflexive filter IP65 protection on front filter extruded aluminium anodized in black color for panel mount (optional for wall mount) standard 230 Vac 50/60 Hz optional 115 Vac 50/60 Hz optional 24 Vdc isolated WEIGHT see section 7 and 8 SIZES see section 7 and 8 ENVIRONMENTAL DATA Working Temp. Storage Temp. Relative Hum. from 0 to +50ºC (32/122 ºF) from -20 to +85 C (-4/185ºF) from 0 to 85% non condensed HOLD «HOLD» active in logical state «1». independient for each digit independient for the negative sign in logical state «0» reading updates continuously TEST active in logical state «0». lights all segments «-8.8.8.8.8.8.» BLANK active in logical state «0» lights-off all segments NEGATIVE negative sign active in logical sate «0» with independent «HOLD» control CONSUMPTION CONSUMPTION BY CHANNEL 4 ma at 24 Vdc 1,5 ma at 12 Vdc 150 µa at 5 Vdc 6 VA sizes BDF-24 and BDF-26 12VA sizes BDF-44 and BDF-46 FEMA ELECTRÓNICA - Page 3

4.- CONNECTIONS AND OPERATION OF THE INSTRUMENT Signal connections at SUB-D connector available at the rear of the instrument. Each digit has 4 connection lines (ABCD) for its BCD code, 1 «Hold» line controlling the display update, and 1 control for the decimal point. The negative sign has 1 control line and 1 line for «Hold». Connection lines identified as «+5Vdc» can be used as fixed controls with logical state «1». Connection lines identified with «GND» can be used as fixed controls with logical state «0». The «Digit1» is the Least Significat Digit. DigitX BCD Value Display D C B A 0 0 0 0 0 0 0 0 0 1 1 1 0 0 1 0 2 2 0 0 1 1 3 3 0 1 0 0 4 4 0 1 0 1 5 5 0 1 1 0 6 6 0 1 1 1 7 7 1 0 0 0 8 8 1 0 0 1 9 9 1 0 1 0 10 A 1 0 1 1 11 b 1 1 0 0 12 C 1 1 0 1 13 d 1 1 1 0 14 E 1 1 1 1 15 «BLANK» E D C B A Connector2 Connector1 Digit 3-A Hold2 Digit 2-D Digit 2-C Digit 2-B Digit 2-A Hold1 Digit 1-D Digit 1-C Digit 1-B Digit 1-A 13 12 11 10 9 8 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 BIank Test Hold4 Digit 4-D Digit 4-C Digit 4-B Digit 4-A Hold3 Digit 3-D Digit 3-C Digit 3-B N/C Hold6 Digit 6-D Digit 6-C Digit 6-B Digit 6-A Hold5 Digit 5-D Digit 5-C Digit 5-B Digit 5-A 13 12 11 10 9 8 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 N/C +5 Vdc +5 Vdc Decimal Point-1 Decimal Point-2 Decimal Point-3 Decimal Point-4 Decimal Point-5 Decimal Point-6 GND Hold Negative Sign Negative Sign FEMA ELECTRÓNICA - Page 4

5.- POWER CONNECTIONS The power connector allows one terminal for earth and two power terminals. Internal fuse is integrated on the connector and an additional fuse is available as a spare part. The value of the fuses depends on the power supply, and is according to rule IEC127/2 230 Vac - 200 ma fuse time-lag 115 Vac - 400mA fuse time-lag 24 Vdc - 350 ma fuse fast Powered 230 Vac (115 Vac optional) Fuse Powered 24 Vdc Isolated + - 6.- WARRANTY FEMA ELECTRÓNICA, S.A. warrants this instrument free of defects for a period of 24 MONTHS from the date of shipment. This warranty covers both the materials of the instrument and the processes used for manufacturing. This warranty is excluded and does not apply if the instrument is damaged due to misuse, improper application, accident, or if the instrument has been manipulated or repaired by unauthorized personnel or companies. BLANK SECTION FEMA ELECTRÓNICA - Page 5

7.- SIZES AND DIMENSIONS Size 24/26 A B C 4 digits 57mm 264mm 120mm 112mm (2 ) (10,40 ) (4,75 ) (4,41 ) 6 digits 57mm 384mm 120mm 112mm (2 ) (15,12 ) (4,75 ) (4,41 ) C B A Rear Side Cover Size 44/46 A B C Antirreflexive Filter 4 digits 100mm 480mm 180mm 112mm (4 ) (18,90 ) (7,09 ) (4,41 ) 6 digits 100mm 668mm 180mm 112mm (4 ) (27,10 ) (7,09 ) (4,41 ) Note.- add 27mm to the «C» dimmension for the power supply plug 8.- PANEL CUT-OUT AND WEIGHT Size 24/26 D E Weight 4 digits 57mm 256mm 112mm 2.3 Kg (2 ) (10,07 ) (4,40 ) (5 lbs) 6 digits 57mm 376mm 112mm 2.7 Kg (4 ) (14,80 ) (4,40 ) (6 lbs) Size 44/46 D E Weight PANEL CUT-OUT E D Panel width Max. 14 mm (0,55 ) Min. 2,5mm (0,10 ) 4 digits 100mm 472mm 172mm 5.0 Kg (4 ) (18,58 ) (6,77 ) (11,0 lbs) 6 digits 100mm 680mm 172mm 5.7 Kg (4 ) (36,77 ) (6,77 ) (12,5 lbs) 9- PANEL INSTALLATION Introduce the instrument «1» into the panel cut-out and place a fixation piece «3» on each side. Place the screw «2» through the fixation piece «3» until it presses the panel «4» and is firmly fixed. Note.- The front of the instrument is sealed with a protection level IP65. To have the same level of protection between the panel and the instrument, place a rubber profile (squared or round) as indicated «5». «1» Instrument BDF «2» Screw «4» Panel «3» Fixation piece «5» Rubber profile FEMA ELECTRÓNICA - Page 6

10.- SECURITY PRESCRIPTIONS INSTALLATION PRECAUTIONS.- The installation and operation of this instrument must be done by qualified operators. This instrument DOES NOT have power switch and will start to operate as soon as the power supply is connected. The instrument has an internal protection fuse, according to IEC-127/2, and is located inside the power-supply connector. The values are Fuse 200 ma Time Lag (for 230 Vac power) Fuse 400 ma Time Lag (for 115 Vac power) Fuse 350 ma Fast (for 24 Vdc power) When the instrument is used to control machines or processes where the personnel or the process can be damaged, the appropriate security elements must be added to the system in order to protect the operator and / or the system. SAFETY PRESCRIPTIONS.- This instrument has been designed and verified according to the UNE-20553 rules and is delivered in perfect conditions of operation. This manual contains the adequate information for the electrical installation. Before starting operations for connections, readjustment, substitution, maintenance, repair, etc, the instrument must be unplugged from the power supply. The instrument must be installed in places with good ventilation to avoid excesive heating, and far from sources of electrical noise or magnetic field generators, such as power relays, electrical motors, speed controls, etc... The instrument can not be installed in open places. Do not use until the installation is finished. The instrument is designed to be mounted on a metallic panel with the adequate protections. DO NOT clean the front lens with abrasive products (such as solvents, alcohol, etc) use a clean and water humid rag. Do not expose the instrument to excesive moisture. DO NOT operate the unit in the pressence of flammable gases or fumes. EXCITATION VOLTAGE Vexc.- Instruments BDF-xx-32 and BDF-xx-36 supply an excitation voltage of 10 to 24 Vdc (50mA) to power transducers, available between terminals A and C. Do NOT connect these terminals to an external power supply, permanent damages may result on both instruments. POWER SUPPLY.- Connect the Power Supply to the terminals indicated in this manual. Verify that the voltage and frecuency of the power supply is according to the voltage and frecuency values indicated in the label attached to the unit. DO NOT connect the instrument to power lines which are overloaded, or power lines with loads working in ON/OFF cycles, or with inductive loads. SIGNAL WIRING.- Information to consider relating the wiring of the sensors, probes, transducers, etc. The wires can act as antennas and introduce electrical noise from the environment into the signal wires, specially if the wires are close to noise sources or electromagnetic sources. There are several rules generally known which should be taken into consideration for the wiring : a.- DO NOT install impulse, control or signal wires together in the same conduits as the wires connected to power lines, connected to CC or AC engines, electromagnets,... b.- When using shielded wires, connect the shield to the common of the instrument, and leave not-connected the probe side c.- The wires of impulse, control and signal should be placed in places far away from switches, transformers, control relays, etc... IN CASE OF FIRE 1.- Disconnect the unit from the power supply. 2.- Give the alarm according to the local rules. 3.- Switch off all the air conditioning devices. 4.- Attack the fire with carbonic snow, do not use water in any case. WARNING : In closed areas do not use systems with vaporized liquids. 11.- DECLARARION OF CONFORMITY DECLARATION OF CONFORMITY Manufacturer.- FEMA ELECTRÓNICA, S.A. Address.- Pol. Ind. Santiga - Altimira 14 (T14 - N2) E-08210 Barberà - BARCELONA ESPAÑA - SPAIN DIRECTIVES EUROPEAN DIRECTIVE FOR LOW VOLTAGE D73/23/CEE AMMENDED BY D93/68/CEE. Equipments powered from 50 to 1000 Vac and/or from 75 to 1500 Vdc. Conforming Products Series.- BDF-24, BDF-26, BDF-44 and BDF-46 Models.- BCD We hereby declare that the above products conform to the essential protection requirements of Directives and Harmonized standards indicated below. Signed.- D. Juncà Position.- Quality Manager Place.- Barberà, 2005 EUROPEAN DIRECTIVE FOR ELECTROMAGNETIC COMPATIBILITY D89/336/ CEE AMMENDED BY D93/68/CEE STANDARDS IMMUNITY UNE EN 50082-1 (1998) EMMISIONS UNE EN 50081-2 (1994) ELECTRICAL SAFETY UNE EN 61010-1 (1997) UNE EN 60204-1 (1998) NOTE.- During an electromagnetic disturbance (10V/m) it is permitted a worst case error of 1% of the A/D range. The instrument will recover automatically its functionality when the disturbance stops, without need of the operator to reset or restart. FEMA ELECTRÓNICA - Page 7

more products Programmable Panel Meters Signal Converters & Isolated Transmitters Large Displays Standard Panel Meters Miniature Panel Meters Large Displays for TIME www.fema.es ELECTRONIC INSTRUMENTATION FOR INDUSTRY FEMA ELECTRÓNICA, S.A. Pol. Ind. Santiga - Altimira 14 (T14 - N2) E-08210 Barberà - BARCELONA ESPAÑA - SPAIN Tel. (+34) 93.729.6004 - www.fema.es Fax (+34) 93.729.6003 - info@fema.es FEMA ELECTRÓNICA - Page 8