Perle 10/100 Ethernet Media Converter Module. Installation Guide. P/N (Rev C)

Similar documents
Perle Gigabit Media Converter Module. Installation Guide P/N

Perle Gigabit Media Converters

Perle PoE/PoE+ 10/100 Ethernet Media Converters

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converters

Perle Protocol Transparent Media Converter Modules

Perle Cx-10GR-STS Media Converter Modules

Perle 10GT Media Converter Modules

Perle 10G Media Converter Modules

Perle 10G Media Converter Modules

Perle MCR200 Installation Guide

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide

Perle S-10GRT-SFP Media Converter Installation Guide

Perle 10/100/1000 Ethernet Extender Modules. 10/100 10/100/1000 (Gigabit)

Perle 10GT Media Converters

Perle Advanced Powered Ethernet Extenders Installation Guide

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

USER S MANUAL. 10/100/1000Base-T 1000Base-SX/LX Gigabit Ethernet Converter GEP-5300TF-C GEP-5400TF-C

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

IMC-21A Quick Installation Guide

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

IMC-21GA Quick Installation Guide

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

IMC-21 Quick Installation Guide

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

IFS MC201-1P/1FS User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

10/100Base-TX to 100Base-TX Mini Converter. Operation Manual

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

Industrial 3-Port Fast Ethernet Media Converter Switches

Gigabit 1000Base-T to 1000Base- SX/LX Converter

Fast Ethernet Converter. User Guide MICROSENS

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

KFC-200. Installation Guide

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

IFS MC350-1T-2S User Manual

LNX-0702G-SFP Series

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER

CSM-200 Series. Hardware Installation Guide. First Edition, November 2009

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

LNP-0501 Series. User Manual. 5-Port Industrial PoE+ Unmanaged Ethernet Switches with 4*10/100Tx (30W/Port) + 1*10/100Tx

PTC-101-M12 Hardware Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

FSW-1609TFX FSW-2409TFX

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

MC100FX-TX-PoE Media Converter User Manual

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

Multi-Power Miniature Media Converter 10/100/1000

PTC-101 Quick Installation Guide

PCI Express Gigabit Ethernet Adapter. User's Guide

10/100/1000Base-T to 1000Base-FX Switch Converter User Guide

10/100 Ethernet Fiber Link Card System

TCF-142-RM Series Hardware Installation Guide

Add 10/100 copper ports to a High Density Media Converter Chassis.

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

LNX-1002C-SFP Series

MDI/MDIX) FEP-32005T-2

MOXA Industrial Media Converter

OPERATOR MANUAL OSD2153P SERIES GIGABIT ETHERNET MEDIA CONVERTER. WITH PoE

Gigabit 1000Base-T to 1000Base- SX/LX Converter. User s Manual NGF-741 Series

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

S7055xM / S7075xM Web Smart Managed 5-Port / 7-Port 10/100 Fast Ethernet Switch w/vlan Support Installation Guide

Owner s Manual. Media Converters Models: N SC & N ST

5/8-Port 10/100/1000Mbps. Industrial Gigabit Ethernet Switch IGS-501 / IGS-801 / IGS-501T / IGS-801T. User's Manual

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS

External VDSL Range Extender. User manual

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

Installation Guide HP J3102A

M727xSP. PoE Powered. Ethernet Media Converter 10/100BASE-TX TO 100BASE-SX/LX. Installation Guide

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

16-Port Chassis Media Converter System Manual

Switch manual Models &

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

Gigabit Ethernet Media Converter

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

8~14-Port Managed Ethernet Switch

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

ICF-1150 Series Quick Installation Guide

Transcription:

Perle 10/100 Ethernet Media Converter Module Installation Guide C-110-XXXXX CM-110-XXXXX Unmanaged Module Managed Module P/N 5500307-15 (Rev C)

Overview This document contains instructions necessary for the installation and operation of the Perle 10/100 Ethernet Media Converter Module(s) (C- 110 and CM-110) that are used in conjunction with a Perle MCR Chassis. The C-110 are unmanaged media converter modules, and the CM-110 are the managed versions. These products convert a 10/100Base-T connection (copper) to a 100Base-X connection (fiber). The fiber connection can be either single mode () or multimode (MM) and can operate over different wavelengths and distances, depending on the model (see table below). For information on management features of the CM-110 module, refer to the MCR-MGT Module User s Guide. Model Connector Mode - Distance Wavelength C-110-M1ST2U CM-110-M1ST2U C-110-M1ST2D CM-110-M1ST2D C-110-M2xx2 CM-110-M2xx2 C-110-M1SC2U CM-110-M1SC2U C-110-M1SC2D CM-110-M1SC2D C-110-S2xx20 CM-110-S2xx20 C-110-S2xx40 CM-110-S2xx40 C-110-S2xx80 CM-110-S2xx80 C-110-S2xx120 CM-110-S2xx120 C-110-S1xx20U CM-110-S1xx20U C-110-S1xx20D CM-110-S1xx20D C-110-S1SC40U CM-110-S1SC40U C-110-S1SC40D CM-110-S1SC40D ST MM 2 km/1.2 mi. 1310 nm ST MM 2 km/1.2 mi. 1550 nm SC/ST/LC MM 2 km/1.2 mi. 1310 nm SC MM - 2 km/1.2 mi. 1310 nm SC MM - 2 km/1.2 mi 1550 nm SC/ST/LC 20 km/12.4 mi. 1310 nm SC/ST/LC - 40 km/24.9 mi. 1310 nm SC/ST/LC - 80 km/49.7 mi. 1550 nm SC/ST/LC - 120 km/74.6 mi. 1550 nm SC/ST - 20 km/12.4 mi. 1310/1550 nm SC/ST - 20 km/12.4 mi. 1550/1310 nm SC - 40 km/24.9 mi. 1310/1550 nm SC - 40 km/24.9 mi. 1550/1310 nm Note 2: Please refer the Perle web site for the most up to date Installation guides, models and specifications: http://www.perle.com/ 2 Perle 10/100 Media Converter Module Installation Guide

Installation The module comes equipped with a bank of DIP switches and jumpers for setting configuration. The default dip switch settings (all switches in the UP position) and default jumper settings will work for most installations. The following steps are used to configure the Perle 10/100 Ethernet Media Converter Module: 1. Set the Auto-MDIX jumper (optional). 2. Set the Auto-Config jumper (CM-110 only) (optional) 3. Set the DIP switch settings (optional). 4. Insert the Media Converter Module into the Chassis. 5. Connect the fiber cable. 6. Connect the copper cable. Auto-MDIX Jumper Note: The factory settings for Auto-MDIX will work for most installations, but if there is a need to modify the settings, follow the procedure below. The AUTO-MDIX jumper (J5) is located on the upper edge, at the midpoint of the module (see diagram below for labelling).. By covering or strapping pins 2 and 3(AUTO), the C-110 and CM-110 will automatically detect the Ethernet cable s polarity and configure itself as either an MDI or an MDIX device. By covering or strapping pins 1 and 2(MDIX), the C-110 and CM-110 will operate as an MDIX device Removing the strapping is the same as AUTO. NOTE: The default jumper setting is AUTO Perle 10/100 Media Converter Module Installation Guide 3

Auto-Config Jumper (CM-110 only) The Auto-Config jumper (J6) is located just below the Auto-MDIX jumper (see above). Refer to the diagram below for labelling. This jumper only applies to CM-110 modules. Strapping pins 1 and 2 of the jumper will set the module in SW mode and strapping pins 2 and 3 will set it in Auto Config mode. Auto: When set to Auto the module will, at power-up, check its internal flash memory to see if configuration information has been downloaded to it from a management module. If so it will use this as its running configuration. If there is no configuration in flash it will read the settings of the DIP switches and use those as its running configuration. SW: When set to SW (Switch), the module will, at power-up, read the settings of the DIP Switches and use those as its running configuration. It will ignore any configuration information in its flash memory. NOTE: The default jumper setting is Auto 4 Perle 10/100 Media Converter Module Installation Guide

DIP Switches DIP Switch Settings Auto Negotiation (Switch 1) Switch Position Up (default) Down Mode Auto Off Note: Auto negotiation should only be turned off, if the copper link partner does not support Auto Negotiation or fixed settings are required by the copper link partner. Auto: In this mode of operation the Media Converter Module will negotiate Ethernet parameters on the copper connection. This will ensure that the most optimal connection parameters will be used. If the copper link partner does not support Auto negotiation, the Media Converter Module will parallel detect to 10 or 100 Mbps and force Half Duplex mode as per IEEE specifications. Off: When the Auto Negotiation switch is set to the OFF position, the Media Converter Module will not negotiate the Ethernet parameters Perle 10/100 Media Converter Module Installation Guide 5

with the copper link partner. The parameters used by the Media Converter Module will be determined by the Duplex (switch 4) and Speed (switch 5) dip switch settings. Link Mode (Switch 2) Switch Position Up (default) Down Mode Link Pass-Through Mode Standard Mode Link Pass-Through: In this mode, the link state on one connection is directly reflected through the Media Converter Module to the other connection. If the link is lost on one of the connections, then the other link will be brought down. With Media Converters on both ends of the fiber link and both setup for Link Pass-Through, a loss of copper link on the far end device will propagate through both Converters and will result in a loss of copper link at the near end device. This would, in effect, resemble a direct copper connection Standard Mode: In this mode, the links on the fiber and copper sides can be brought up and down independently of each other. A loss of link on either the fiber or copper port can occur without affecting the other connection. Far End Fault (Switch 3) Switch Position Up (default) Down Mode Enabled Disabled Enabled: If the Media Converter Module detects a loss of receive fiber signal, it will transmit a FEF signal to the remote Media Converter. This, in effect, notifies the fiber link partner that an error condition exists on the fiber connection. If the remote Media Converter is set up for Far End Fault (FEF) and the local Media Converter is set up with Link Pass-Through, a loss of 6 Perle 10/100 Media Converter Module Installation Guide

fiber link on either the transmit or receive line will be passed through to the local copper connection thus notifying the connected device. If the Media Converter has been set to Link Pass-Through mode, the effect will be the same as FEF, since the link loss on the fiber receiver will result in bringing down the copper link, which will in turn cause the transmit fiber link to be brought down. Note: If it is required to either generate or detect the FEF signal, then the FEF switch needs to be set. Disabled: The Media Converter Module will not monitor for or generate Far End Fault. The following diagram is an illustration of the operation of this feature. (A) Remote Media Converter setup for Far End Fault Enabled, Auto Negotiation OFF and Link Mode Standard. (B) Local Media Converter setup for Far End Fault - Enabled, Link Pass-Through - On and Auto Negotiation - OFF 1 (A) Loses fiber connection on its receiver. 2 (A) Sends FEF. 3 (B) Detects FEF signal and shuts down the fiber link. 4 (B) Drops link on copper connection because Link Pass-Through is configured. 5 (A) Link on copper connection is not affected because Link Mode is set to Standard. Perle 10/100 Media Converter Module Installation Guide 7

Duplex (copper) (Switch 4) Switch Position Up (default) Down Mode Full Half Note: When Auto Negotiation (SW1) is set to Off, the Media Converter will use this Duplex setting for its copper connection. Up: The Media Converter Module will be set to Full Duplex mode. Down: The Media Converter Module will be set to Half Duplex mode. Speed (copper) (Switch 5) Switch Position Mode Up (default) 100 Down 10 Note: When Auto Negotiation (SW1) is set to Off, the Media Converter Module will use this Speed setting for its Ethernet copper connection. Up: The Media Converter will be fixed at 100 Mbps. Down: The Media Converter will be fixed at 10 Mbps. 8 Perle 10/100 Media Converter Module Installation Guide

Duplex (fiber) (Switch 6) Switch Position Up (default) Down Mode Full Half Up: The Media Converter Module s fiber link will be set to Full Duplex Mode. Down: The Media Converter Module s fiber will be set to Half Duplex Mode. Loopback (Switch 7 Switch Position Up (default) Down Mode Disabled Enabled Disabled: This is the setting for normal operation. The switch must be set to this position in order for data to pass through the Media Converter Module. Enabled: This is a test mode. All data received on the receive (RX) fiber connection is looped back to the transmit (TX) fiber connection. The state of the copper link is not relevant since no data is passed through to the copper side. This mode will override all other switch settings. Perle 10/100 Media Converter Module Installation Guide 9

Installing or Replacing Media Converter Modules Caution: Observe electrostatic discharge precautions when installing the Media Converter Module(s) into the Chassis. Failure to observe this caution could result in damage to the Media Converter Module(s) and /or chassis. The Perle Media Converter Modules can be installed in any available slot and in any order within the Chassis. Installing or Replacing a Media Converter Module 1. Remove the Media Converter Module from its packaging. 2. Using a cross-head screwdriver, remove the screw holding the face plate to the Chassis to reveal the slot opening. 3. Set the jumpers and DIP switches on the Media Converter Module to the desired operating mode. 4. Locate the top and bottom alignment guides inside the Chassis. 5. Using the module alignment guides gently slide the module into the slot until it becomes flush with the front of the Chassis. Light pressure may be needed to seat the module. Do not force the module as you might cause some damage. If there is resistance, remove the module, check the module connector for damaged or incorrectly aligned pins, if there is no damage, retry module insertion. 10 Perle 10/100 Media Converter Module Installation Guide

6. Tighten the captive retainer screw to ensure the Media Converter Module is locked in place. 7. Remove the dust cap from the fiber connector and connect the fiber and copper cables. Removing Media Convert Modules 1. Loosen the captive retainer screw on the front of the Media Converter Module and gently pull the Media Converter Module out. 2. If not inserting a replacement, cover the opened slot with a face plate and secure the screw Installing the Duplex Fiber Cable Locate a 100Base-X compliant duplex (2 strands) fiber cable with appropriate connectors. Connect the fiber cables from the Media Converter Module to the other Media Converter/switch/fiber device ensuring that the RX and TX are reversed (crossed) at the opposite end. Installing the Simplex Fiber Cable Locate a 10/100Base-X compliant simplex (1 strand) fiber cable with appropriate connectors. Connect the fiber cable from one Media Converter Module to the other Media Converter/switch/fiber device. Perle 10/100 Media Converter Module Installation Guide 11

Installing the Copper Cable Locate 10/100Base-T compliant copper cables with male, RJ- 45 connectors installed at both ends. Connect the RJ-45 cable between the Perle Media Converter Module and the device. Note: The Perle Media Converter Module supports Auto-MDIX which allows a straight-through or cross-over Ethernet cable. See page 4 in this guide for jumper positions. 12 Perle 10/100 Media Converter Module Installation Guide

Operation Status LED The Perle 10/100 Ethernet Media Converter Modules have six single color status LEDs located on the face plate of the module. PWR On Power is on; module is operating normally Blinking (slow) The module is in Loopback mode. Blinking (fast) The module has a hardware failure. FDF (fiber) On Full Duplex Mode. Off Half Duplex Mode. LKF (fiber ) On The fiber link is present Off No fiber link is present. Blinking (fast) The fiber link is present and receiving data. 100 (copper speed) On 100 Mbps Off 10 Mbps FDC (copper) On Full Duplex Mode. Off Half Duplex Mode. LKC (copper) On The copper link is present. Off No copper link present. Blinking (fast) The copper link is present and receiving data. Perle 10/100 Media Converter Module Installation Guide 13

Other Features Auto-MDIX: Auto-MDIX (automatic medium-dependant interface crossover) detects the signalling on the 10/100BASE-T interface to determine the type of cable connected (straight-through or crossover) and automatically configures the connection. Error Recovery: In certain configurations, and under specific conditions where the Media Converter Module brings down a link to convey status, there is potential for a deadlock. Recovery is achieved by momentarily restoring the link to see if the original failure has been resolved. If it has not, the link will be forced down again, however if the original problem has been resolved, the link will be restored. Pause (IEEE 802.3xy): Integrated Pause signalling is an IEEE feature that temporarily suspends data transmission between two devices in the event that one of the devices becomes overwhelmed. The Perle Media Converter Module can generate and respond to Pause messages. 14 Perle 10/100 Media Converter Module Installation Guide

Troubleshooting General Ensure that the Media Converter Module is securely seated in the chassis. The PWR LED should be on. Ensure both devices on either end of the fiber are compatible. If using a simplex fiber connection, ensure that you have both an Upstream (U) and Downstream (D) Media Converter. Ensure all cabling is of the correct type and is in good working order. For duplex fiber connections, ensure the RX and TX has been reversed between the two Media Converters. No connectivity If unable to get full connectivity with all DIP switches in the UP position, these methods are recommended for troubleshooting. Method 1 1. If the Module is a CM-110, set the Auto-Config jumper (J6) to SW so that DIP switches are being read. 2. Set the Link mode to Standard (SW2 Down) on both Media Converters. Leave all other switches in the Up position. 3. Connect the near end device to the copper connection. The LKC LED indicates good copper connection. If the LKC LED is not lit, then check the copper cable and the attached device. Repeat for the far end Media Converter. 4. Connect the fiber cable to both Converters. The LKF LED indicates good fiber connection. If no LKF LED then check the fiber cabling. 5. Return converters to desired configuration. Perle 10/100 Media Converter Module Installation Guide 15

Method 2: The fiber connection can also be verified by configuring the remote Media Converter for loopback mode. The LKF LEDs on both Media Converters should be lit. Data should pass through the local converter, over the fiber connection to the remote Media Converter. At the remote Media Converter, the data will be looped back and passed through the fiber, once again, to pass through the local converter to the copper link. Note: If troubleshooting a CM-110, setting the Auto-Config jumper (J6) to SW will ensure the DIP switches are being read. 16 Perle 10/100 Media Converter Module Installation Guide

Technical Specifications Maximum Power Consumption: 2.1 watts Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -25 C to 70 C (-13 F to 158 F) Operating Humidity: 5% to 90% non-condensing Storage Humidity: 5% to 95% non-condensing Operating Altitude: Up to 3,048 m (10,000 ft) MTBF: (C-110) 577,872 hours (CM-110) 561,817 hours Fiber Optic Specifications: Model C-110-M1ST2U CM-110-M1ST2U C-110-M1ST2D CM-110-M1ST2D C-110-M2SC2 CM-110-M2SC2 C-110-M1SC2U CM-110-M1SC2U C-110-M1SC2D CM-110-M1SC2D C-110-M2ST2 CM-110-M2ST2 C-110-M2LC2 CM-110-M2LC2 C-110-S2SC20 CM-110-S2SC20 C-110-S2ST20 CM-110-S2ST20 C-110-S2LC20 CM-110-S2LC20 C-110-S2SC40 CM-110-S2SC40 C-110-S2ST40 CM-110-S2T40 Mode MM MM MM MM MM MM MM Wavelength (nm) RX: 1550 RX: 1310 RX: 1310 RX: 1550 RX: 1310 RX: 1310 RX: 1310 RX: 1310 RX: 1310 RX :1310 RX :1310 RX :1310 TX Power (db) Min: -15 Max: -8 Min: -15 Max: -8 Min: -20 Max: -12 Min: -15 Max: 0 Min: -15 Max: 0 Min: -20 Max: -12 Min: -20 Max: -12 Min: -18 Max: -7 Min: -15 Max: -8 Min: -15 Max: 0 Min: -5 Max: 0 Min: -5 Max: 0 RX Power (db) Min: -3 4 Min: -3 4 Min: -31 Max: -14 Min: -28 Max: -8 Min: -28 Max: -8 Min: -31 Max: -14 Min: -30 Max: -14 Min: -32 Min: -32 Min: -34 Max: -5 Min: -34 Min: -34 Budget (db) 12 12 11 13 13 11 10 14 17 19 29 29 Perle 10/100 Media Converter Module Installation Guide 17

C-110-S2LC40 CM-110-S2LC40 C-110-S2SC80 CM-110-S2SC80 C-110-S2ST80 CM-110-S2ST80 C-110-S2LC80 CM-110-S2LC80 C-110-S2SC120 CM-110-S2SC120 C-110-S2ST120 CM-110-S2ST120 C-110-S2LC120 CM-110-S2LC120 C-110-S1SC20U CM-110-S1SC20U C-110-S1SC20D CM-110-S1SC20D C-110-S1ST20U CM-110-S1ST20U C-110-S1ST20D CM-110-S1ST20D C-110-S1SC40U CM-110-S1SC40U C-110-S1SC40D CM-110-S1SC40D RX :1310 RX: 1550 RX: 1550 RX: 1550 RX: 1550 RX: 1550 RX: 1550 RX: 1550 RX:1310 RX: 1550 RX:1310 RX:1550 RX:1310 Min: -5 Max: 0 Min: -5 Max: 0 Min: -5 Max: 5 Min: -5 Max: 0 Min: 0 Max: 5 Min: 0 Max: 5 Min: 0 Max: 5 Min: -14 Max: -8 Min: -14 Max: -8 Min: -15 Min: -15 Min: -8 Min: -8 Min: -34 Min: -34 Min: -34 Min: -34 Min: -35 Min: -35 Max: 0 Min: -35 Min: -32 Min: -32 Min: -3 4 Min: -3 4 Min: -33 Min: -33 29 29 29 29 35 35 35 18 18 12 12 25 25 Fiber Cabling Requirements: MM: : 50/125 microns or 62.5/125 microns 9/125 microns Ethernet Copper Cabling Requirements: Category 5 UTP or STP 24-22 AWG Straight through or Ethernet crossover 18 Perle 10/100 Media Converter Module Installation Guide

Compliance Information FCC This product has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. EN 55022, Class A WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. EN 55024, Class A Laser Safety IEC 60825-1:2007 This product meets Class I Laser safety requirements per IEC-60825-1:2007 standard and complies with FDA/CDRH 21 CFR1040.10 and 21 CFR1040.11. WARNING: Visible and invisible laser radiation may be present when cables are not connected. Do not stare into the beam or view the beam directly with optical instruments. Failure to observe this warning could result in an eye injury or blindness. WARNING: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure. Perle 10/100 Media Converter Module Installation Guide 19

Warranty / Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage. Details can be found at: http://www.perle.com/support_services/warranty.shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. A Technical Support Query may be made via this web page. www.perle.com/support_services/support_request.shtml Copyright 2010-2017 Perle Systems Limited All rights reserved. No part of this document may be reproduced or used in any form without written permission from Perle Systems Limited. 20 Perle 10/100 Media Converter Module Installation Guide