SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

Similar documents
SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

Readme SiVArc V14 SP1 Update 6

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Siemens Drives & PLCs

SIMATIC. Function modules FM 351 First Steps in Commissioning. Purpose of the Getting Started. Requirements 2

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

ST (6ES7132-6FD00-0BB1)

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

SIMATIC. ET 200S distributed I/O IM151-1 HIGH FEATURE interface module (6ES7151-1BA02-0AB0) Preface. Properties 1. Parameters 2.

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

PROFIsafe SITRANS. Pressure transmitter SITRANS P, DS III PROFIsafe series. Product Information 7MF4*34 04/2008 A5E

S7-300 Programmable Controller

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

English. SIMATIC Sensors. RFID-Systems RF600. Getting Started. Edition 11/2005; J31069-D0172-U001-A1-7618

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

HawkEye 45T Display User Manual

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

SIMATIC. ET 200SP Digital output module DI 8x24VDC SRC BA (6ES7131-6BF61-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. S7-1500/ET 200MP Technology Module TM NPU (6ES7556-1AA00-0AB0) Preface. Documentation guide. Product overview. Wiring

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

Technological Functions SIMATIC. ET 200S Technological Functions. Preface 1. 1Count24V. 1Count5V 3 1SSI 4 2PULSE. Operating Instructions

First Steps with S7-PDIAG and ProAgent

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

CM PtP RS422/485 BA communication. module (6ES7540 1AB00 0AA0) SIMATIC. S7-1500/ET 200MP CM PtP RS422/485 BA communication module (6ES7540 1AB00 0AA0)

SIMATIC. Distributed I/O Device ET 200iSP. Preface, Contents. Product Overview Getting Started with Commissioning. Configuration Options.

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. Process Control System PCS 7 V7.0 SP1 Software Update With Utilization of New Functions (PCS 7 V6.x to V7.0 SP1) Preface.

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

ST (6ES7522-5HF00-0AB0)

SIMATIC. Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components. Preface. Creating PROFINET components in STEP 7

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

SIMATIC. S7-1500/ET 200MP Digital input module DI 16x24VDC BA (6ES7521-1BH10-0AA0) Preface. Documentation guide. Product overview.

ST (6ES7522-1BH00-0AB0)

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

SIMATIC. ET 200SP Digital input module DI 8x24VDC BA (6ES7131-6BF01-0AA0) Preface. Documentation guide 1. Product overview 2.

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

Digital output module. DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) SIMATIC

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH

SIMATIC. Automation system Fail-safe signal modules. Preface. Product overview 1. Configuration options 2. Configuration and parameter assignment

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

SIMATIC. Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS S120. Introduction. Preparation 2. Learning units 3. Further Information 4

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

Manual Edition 03/2010

SIMATIC. S7-1500/ET 200MP DI 16x230VAC BA Digital Input Module (6ES7521-1FH00-0AA0) Preface. Documentation guide. Product overview.

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

Analog Output Module AQ 4xU/I ST (6ES7135-6HD00-0BA1) SIMATIC. ET 200SP Analog Output Module AQ 4xU/I ST (6ES7135-6HD00-0BA1) Preface

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

SIMATIC. Modifying the System during Operation via CiR. Preface Contents. Requirements and Overview 1. CiR Objects and CiR Modules

SIMATIC. ET 200SP HA Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Security information 1. Product overview 2.

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

SIMATIC. Process Control System PCS 7 OS Web Option (V7.1) Preface 1. Additional documentation 2. Overview of PCS 7 OS Web Option

SIMATIC. ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Preface. Guide to the documentation. New properties. Product overview 3

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Configuration limits for products of the HARDNET-PB DP-Base 1

Digital output module. DQ 4x24VDC/2A ST (6ES7132-6BD20-0BA0) SIMATIC. ET 200SP Digital output module DQ 4x24VDC/2A ST (6ES7132-6BD20-0BA0) Preface

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC. Process Control System PCS 7 V7.0 SP1 Security Information Note: Setting up antivirus software. Preface. Using virus scanners 2

Transcription:

SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 04/2007 A5E01119980-01

Safety Guidelines Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE Qualified Personnel Prescribed Usage Trademarks indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Note the following: Disclaimer of Liability WARNING This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach 48 48 90327 NÜRNBERG GERMANY Ordernumber: A5E01119980-01 P 12/2007 Copyright Siemens AG 2007. Technical data subject to change

Preface Preface Purpose of the manual This manual supplements the ET 200S Distributed I/O System Operating Instructions. General functions for the ET 200S are described in the ET 200S Distributed I/O System Operating Instructions. The information in this document along with the operating instructions enables you to commission the ET 200S. Basic knowledge requirements To understand these operating instructions you should have general knowledge of automation engineering. Scope of the manual This manual applies to this ET 200S module. It describes the components that are valid at the time of publication. Recycling and disposal Thanks to the fact that it is low in contaminants, this ET 200S module is recyclable. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste. Additional support If you have any questions relating to the products described in these operating instructions, and do not find the answers in this document, please contact your local Siemens representative. http://www.siemens.com/automation/partner The portal to our technical documentation for the various SIMATIC products and systems is available at: http://www.siemens.com/automation/simatic/portal The online catalog and ordering system are available at: http://www.siemens.com/automation/mall Manual, 04/2007, A5E01119980-01 3

Preface Training center We offer courses to help you get started with the ET 200S and the SIMATIC S7 automation system. Please contact your regional training center or the central training center in D -90327, Nuremberg, Germany. Phone: +49 (911) 895-3200. http://www.siemens.com/sitrain Technical Support You can reach technical support for all A&D projects using the support request web form: http://www.siemens.com/automation/support-request Phone: + 49 180 5050 222 Fax: + 49 180 5050 223 For more information about our technical support, refer to our Web site at http://www.siemens.de/automation/service Service & Support on the Internet In addition to our documentation services, you can also make use of our comprehensive online knowledge base on the Internet. http://www.siemens.com/automation/service&support There you will find: Our Newsletter, which constantly provides you with the latest information about your products. The right documentation for you using our Service & Support search engine. The bulletin board, a worldwide knowledge exchange for users and experts. Your local contact for Automation & Drives in our contact database. Information about on-site services, repairs, spare parts. Lots more can be found on our "Services" pages. 4 Manual, 04/2007, A5E01119980-01

Table of contents Preface... 3 1 Properties... 7 1.1...7 2 Parameters... 11 3 Diagnostics... 13 3.1 Diagnostics using LED display...13 3.2 Error types...14 4 Configuring... 15 4.1 Configuring the address space...15 Index... 17 Manual, 04/2007, A5E01119980-01 5

Table of contents 6 Manual, 04/2007, A5E01119980-01

Properties 1 1.1 Properties The power module PM-E DC24..48V monitors the supply voltage for all the electronic modules in the voltage group. The supply voltage is fed in by means of the TM-P terminal module. You can use all the electronic modules except the 2DI AC120V ST, 2DI AC230V ST, and 2DO AC24..230V/1A in the voltage group of the PM-E DC24..48V power module. Control interface (PIQ) and feedback interface (PII) in the process image for option handling. The current status of the power module is stored in the status byte in the process input image (PII). This is updated irrespective of whether the "No Load Voltage" diagnosis has been enabled. The PM-E DC24..48V power module is suitable for fail-safe modules. CAUTION Only connect the specified rated load voltage of 24 VDC to 48 VDC to the TM-P terminal module of the power module. The connected rated load voltage must correspond to the supply voltage of the electronic modules in the voltage group. Maximum configuration per voltage group The number of modules that can be connected depends on the total current of all modules in a voltage group. This total must not exceed the maximum current carrying capacity. Manual, 04/2007, A5E01119980-01 7

Properties 1.1 Address space of inputs/outputs Address space of inputs/outputs by selecting the following as an option: Options Address space of the inputs Address space of the outputs Status byte (S) 1 byte -- Option handling (O) 8 bytes 8 bytes Status byte and option handling (SO) 9-byte inputs 9 bytes (9th byte not relevant) General terminal assignment Note Terminals A4 and A8 are only available at specified terminal modules. Terminal assignment for PM-E DC24..48V (6ES7138-4CA50-0AB0) Terminal Assignment Terminal Assignment Notes 2 L+ 6 L+ L+: Rated load voltage 24VDC to 48 VDC 3 M 7 M M: Ground A4 AUX1 A8 AUX1 AUX1: Protective-conductor terminal or potential bus (freely usable up to 230 VAC) Usable terminal modules TM-P15C23-A1 (6ES7193-4CC30-0AA0) TM-P15S23-A1 (6ES7193-4CC20-0AA0) TM-P15N23-A1 (6ES7193-4CC70-0AA0) Usable terminal modules for PM-E DC24..48V (6ES7138-4CA50-0AB0) TM-P15C23-A0 (6ES7193-4CD30-0AA0) TM-P15S23-A0 (6ES7193-4CD20-0AA0) TM-P15N23-A0 (6ES7193-4CD70-0AA0) TM-P15C22-01 (6ES7193-4CE10-0AA0) TM-P15S22-01 (6ES7193-4CE00-0AA0) TM-P15N22-01 (6ES7193-4CE60-0AA0) Spring terminal Screw-type terminal Fast Connect 8 Manual, 04/2007, A5E01119980-01

Properties 1.1 Block diagram Figure 1-1 Block diagram of the PM-E DC24..48V power module Technical data PM-E DC24..48V (6ES7138-4CA50-0AB0) Dimensions and weight Dimension B (mm) 15 Weight Rated load voltage Approx. 35 g Voltages, currents, potentials Reverse polarity protection Yes Overvoltage protection No Protection with automatic circuit breakers Max. current-carrying capacity (up to 60 C) 24 VDC to 48 VDC Yes, tripping characteristic B, C 10 A Short-circuit protection No Electrical isolation Between rated load voltage and backplane Yes bus Between the power modules Yes Insulation test voltage 500 VDC Current consumption From the load voltage L+ (no load) Max. 12 ma Power dissipation of the module Typically 500 mw Parameter length 3 bytes Status, interrupts, diagnostics Diagnostic function Yes Group error Red "SF" LED Load voltage monitoring Green "PWR" LED Diagnostic information readable Yes Manual, 04/2007, A5E01119980-01 9

Properties 1.1 10 Manual, 04/2007, A5E01119980-01

Parameters 2 Parameters The following table lists the power module parameters. Table 2-1 Parameters for power modules PM-E 24 to 48 VDC Range of values Default setting Applicability Diagnostics: No load voltage disable/enable Disable Power module The parameters are explained below. Diagnostics: No load voltage Use this parameter to enable a diagnostic message because there is no load voltage. If there is no load voltage only the diagnostic message of the affected power module is sent to the DP master. The SF error LEDs of all modules in the relevant potential group light. Manual, 04/2007, A5E01119980-01 11

Parameters 12 Manual, 04/2007, A5E01119980-01

Diagnostics 3 3.1 Diagnostics using LED display Power module LED displays on the power module: 1 2 1 2 Batch error (red) Load voltage (green) Status and error displays by means of LEDs on power modules The table below shows the status and error displays on the power module. SF on Event (LEDs) PWR off Cause No parameter assignment or incorrect module plugged in. A diagnostic message is pending. There is no load voltage at the power module. Remedy Check the parameter assignment. Evaluate the diagnostics. Check the load voltage. Manual, 04/2007, A5E01119980-01 13

Diagnostics 3.2 Error types 3.2 Error types Power module error types The diagnostic message is reported on channel 0 and applies to the entire module. The table below shows the types of errors affecting power modules Table 3-1 17D Power module error types Error type Meaning Remedy 10001: Encoder or load voltage missing Supply voltage not present or too low. Correct the process wiring. Check the supply voltage. 14 Manual, 04/2007, A5E01119980-01

Configuring 4 4.1 Configuring the address space Address area for option handling and status byte You can control and monitor option handling, and evaluate the status byte of the power module using the control (PIO) and feedback interface (PII). The address range of the control (PIO) and feedback interface (PII) depends on how the corresponding entry in the configuration software is configured, or which entry has been selected. This table shows the PII feedback interface and the PIO control interface for different entries. Table 4-1 PII feedback interface and PIO control interface With STEP 7, HW Config PII feedback interface PIO control interface or COM PROFIBUS or other configuration software Usual entry for the power --- --- module Ends in...s IBx Status byte --- Ends in...o IBx QBx ::: IBx+7 Option handling ::: QBx+7 Option handling Ends in...so IBx QBx ::: IBx+7 Option handling ::: QBx+7 Option handling IBx+8 Status byte QBx+8 Not applicable Manual, 04/2007, A5E01119980-01 15

Configuring 4.1 Configuring the address space Status byte for power modules Figure 4-1 Assignment of status byte for power modules 16 Manual, 04/2007, A5E01119980-01

Index B Basic knowledge requirements, 3 Block diagram, 9 D Disposal, 3 I Internet Service & Support, 4 M Maximum configuration, 7 P Parameters for power modules, 11 Power modules, 13 Error types, 14 Parameters, 11 Properties, 7 R Recycling, 3 S Scope Manual, 3 Service & Support, 4 T Technical data, 9 Technical Support, 4 Terminal assignment, 8 Training center, 4 Manual, 04/2007, A5E01119980-01 17

Index 18 Manual, 04/2007, A5E01119980-01