Radiance, Irradiance and Reflectance

Similar documents
Philpot & Philipson: Remote Sensing Fundamentals Interactions 3.1 W.D. Philpot, Cornell University, Fall 12

STS Spectrometer Getting Started

Topic 2: Reflection 1

Standard Operating Procedure for the Horiba FluroMax-4

Integrating Sphere Uniform Light Source Applications

2017 Summer Course on Optical Oceanography and Ocean Color Remote Sensing. Introduction to Remote Sensing

Engineered Diffusers Intensity vs Irradiance

The portable Finnish Geodetic Institute Field Goniospectrometer. Maria Gritsevich, Jouni Peltoniemi, Teemu Hakala and Juha Suomalainen

Physical Optics. You can observe a lot just by watching. Yogi Berra ( )

Reflective Illumination for DMS 803 / 505

ASD FieldSpec Pro HandHeld Cookbook

TracePro Stray Light Simulation

FluxGage. FluxGage. LED Luminaire Measurement System User Manual

Quick Start Guide: Welcome to OceanView

D&S Technical Note 09-2 D&S A Proposed Correction to Reflectance Measurements of Profiled Surfaces. Introduction

2017 Summer Course on Optical Oceanography and Ocean Color Remote Sensing. Apparent Optical Properties and the BRDF

Multi angle spectroscopic measurements at University of Pardubice

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax

Mu lt i s p e c t r a l

Particles and Waves Final Revision Exam Questions Part 2

Validation of the Gonioreflectometer

AP Physics Problems -- Waves and Light

Use of the Polarized Radiance Distribution Camera System in the RADYO Program

CfE Higher Physics. Particles and Waves

Operating Procedure for Horiba Raman Microscope

Optics Vac Work MT 2008

Chapter 36. Diffraction. Dr. Armen Kocharian

OCEAN OPTICS Chem 2000 Spectrophotometer

Light Sources opmaak.indd :32:50

Color and Shading. Color. Shapiro and Stockman, Chapter 6. Color and Machine Vision. Color and Perception

CS201 Computer Vision Lect 4 - Image Formation

MODULE 3 LECTURE NOTES 3 ATMOSPHERIC CORRECTIONS

Colour Reading: Chapter 6. Black body radiators

Today. Global illumination. Shading. Interactive applications. Rendering pipeline. Computergrafik. Shading Introduction Local shading models

Module 5: Video Modeling Lecture 28: Illumination model. The Lecture Contains: Diffuse and Specular Reflection. Objectives_template

Speed of light E Introduction

Light Tec Scattering measurements guideline

ENHANCEMENT OF DIFFUSERS BRDF ACCURACY

Photobiological Measurement Per IEC Solutions Overview. Gooch and Housego (Orlando)

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

Evaluation of Satellite Ocean Color Data Using SIMBADA Radiometers

BWSpec 4 Software User Manual. 19 Shea Way, Newark, DE Tel: (302) Fax: (302) Web:

Raman Spectrometer Installation Manual

OOIBase32 Spectrometer Operating Software Operating Instructions

Light Tec Scattering measurements guideline

Standard Operating Procedure of Triboindenter (Hysitron TI 950)

Chapter 82 Example and Supplementary Problems

Light Tec Scattering measurements guideline

CSE 167: Introduction to Computer Graphics Lecture #6: Lights. Jürgen P. Schulze, Ph.D. University of California, San Diego Fall Quarter 2016

Samba Hair System User manual Jefferson Blvd. Culver City, CA 90230, USA Tel: (310) Fax: (310)

Polarized Downwelling Radiance Distribution Camera System

Laboratory 6: Light and the Laser

Spectrographs. C. A. Griffith, Class Notes, PTYS 521, 2016 Not for distribution.

Lecture PowerPoints. Chapter 24 Physics: Principles with Applications, 7 th edition Giancoli

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

Importing ASD-Spectra

OTO Photonics. Sidewinder TM Series Datasheet. Description

Grazing Angle 2 Theta Phase Analysis

Fluorimeter User s Booklet

Cost-effective System for Inline Coating Evaluation in R2R Processes. Craig Johnson Business Developement Manager

SPECTRAL IMAGING VIEWER SOFTWARE MANUAL

Applications of Piezo Actuators for Space Instrument Optical Alignment

Scattering measurements. Guidelines for measurements service

Experiment 5: Exploring Resolution, Signal, and Noise using an FTIR CH3400: Instrumental Analysis, Plymouth State University, Fall 2013

UNIT 102-9: INTERFERENCE AND DIFFRACTION

Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question

Light Tec Scattering measurements guideline

Understanding Variability

PHYSICS 116 INTERFERENCE AND DIFFRACTION

CRISM (Compact Reconnaissance Imaging Spectrometer for Mars) on MRO. Calibration Upgrade, version 2 to 3

Lighting. Figure 10.1

Modeling Custom Surface Roughness with LucidShape 2D Scatter Curve BSDF Material

Use of the Polarized Radiance Distribution Camera System in the RADYO Program

New capabilities of diffuser calibration lab at GSFC NASA to support remote sensing instrumentation

2.2. Facilities Requirements

CSE 167: Lecture #7: Color and Shading. Jürgen P. Schulze, Ph.D. University of California, San Diego Fall Quarter 2011

Nanoparticle Optics: Light Scattering Size Determination of Polystryene Nanospheres by Light Scattering and Mie Theory

PHYSICS 116 POLARIZATION AND LIGHT MEASUREMENTS

CONTENTS. Quick Start Guide V1.0

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Field Spectroscopy, and its role in Earth Observation

Chapter 2: Wave Optics

Interference of Light

MODULE 3. FACTORS AFFECTING 3D LASER SCANNING

OtO Photonics. Sidewinder TM Series Datasheet. Description

Broadband Interferometry - a non-contact optical method for measuring the thickness of transparent thin films and coatings

Lecture 1 Image Formation.

Linescan System Design for Robust Web Inspection

2/26/2016. Chapter 23 Ray Optics. Chapter 23 Preview. Chapter 23 Preview

Lecture 22: Basic Image Formation CAP 5415

Michelson Interferometer

Spectrometer Visible Light Spectrometer V4.4

EELE 482 Lab #3. Lab #3. Diffraction. 1. Pre-Lab Activity Introduction Diffraction Grating Measure the Width of Your Hair 5

Chapter 32 Light: Reflection and Refraction. Copyright 2009 Pearson Education, Inc.

PHYSICS. Chapter 34 Lecture FOR SCIENTISTS AND ENGINEERS A STRATEGIC APPROACH 4/E RANDALL D. KNIGHT

Appendix 1: DataStudio with ScienceWorkshop Sensors Tech Tips

OPSE FINAL EXAM Fall CLOSED BOOK. Two pages (front/back of both pages) of equations are allowed.

Chemistry Instrumental Analysis Lecture 6. Chem 4631

DataHub: FAQs/Troubleshooting

Transcription:

CEE 6100 Remote Sensing Fundamentals 1 Radiance, Irradiance and Reflectance When making field optical measurements we are generally interested in reflectance, a relative measurement. At a minimum, measurements of reflectance require observations of the downwelling irradiance and the upwelling radiance. While neither observation has to be in absolute units (e.g., WWmm 2 ), calibration is still required. This lab (and the associated problem set) is intended to provide some insight into the requirements and procedures for making reflectance measurements in the lab and in the field. We will also consider the further requirements for making absolute measurements of radiance and irradiance. REFLECTANCE There are several type of reflectance measurement. The most common for remote sensing purposes is Remote sensing reflectance, RR RRRR. Remote Sensing Reflectance: The simplest reflectance measurement that is commonly used in remote sensing applications is a ratio of upwelling radiance to the downwelling irradiance. This is defined as the remote sensing reflectance, RR RRRR : RR RRRR = LL uu (λλ, θθ dd ) EE dd (λλ) uuuuuuuuuuuuuuuuuu rrrrrrrrrrrrrrrr dddddddddddddddddddddd iiiiiiiiiiiiiiiiiiii There are several issues to consider when deciding how to go about making a reflectance measurement. The main considerations are the stability of the illumination and the availability of radiometers. Stability of the light field is always an issue in field measurements because sun and skylight can, and do, vary rapidly. Since reflectance requires a pair of measurements (LL UU & EE DD ), if a single spectrometer is used to measure both LL UU & EE DD, and the light field changes between measurements, then one cannot compute a reliable reflectance. On the other hand, if a pair of spectrometers is used to make the two measurements simultaneously, they must be crosscalibrated. While it is more efficient in the field to have the two calibrated spectrometers, it is less expensive and usually sufficient to use a single spectrometer and move fast. In the laboratory it is less of a problem to use one radiometer since the illumination can be controlled. (1) 1) Procedure using a single spectrometer: Using a single spectrometer, sequentially measure 1) the upwelling radiance from a target, LL tt and 2) the upwelling radiance from a reflectance standard, LL ss Measurements must be made close enough in time to ensure that the atmospheric conditions have not changed. RR RRRR can then be retrieved from the relative reflectance if the absolute reflectance (ρ ss ) of the standard is known: time 1 A Target, L t time 2 A Standard, L s E Figure 1: Measuring reflectance with a single radiance meter. The measurements cannot be made simultaneously.

CEE 6100 Remote Sensing Fundamentals 2 RR RRRR (λλ) = LL uu (λλ) EE dd (λλ) = LL tt (λλ) πll ss (λλ) ρρ ss (λλ) (2) Note that the standard is assumed to be Lambertian. If the radiance measured from a perfectly reflective Lambertian standard is LL dd, then EE dd = πll dd, and the radiance from a real reflectance standard is then, ρρ ss LL dd = LL ss. This procedure will produce consistent results ONLY if the light field has not changed between measurements. We will use this procedure in today's lab. It is probably the most commonly used field procedure. 2) Procedure using two radiance meters: An alternative to sequential measurement is to use two cross-calibrated instruments. The measurements of radiance from the object and radiance from the standard can thus be made simultaneously with the instrument pair (Figure 2). This approach requires that the two instruments be cross-calibrated and that the two measurements be, in fact, made simultaneously, and in close proximity. In this case both instruments are observing radiance and the only difference from the first method is that the measurements are made simultaneously. It is helpful if the instruments are as similar as possible, but it is critical that they be calibrated spectrally and cross-calibrated in their response (Bachmann et al., 2012). This method also uses the reflectance standard, and requires that the reflectance standard be calibrated as well. 3) Procedure using one radiance meter and one irradiance meter: With either the "two-instrument" or "sequential" measurement approaches just described, the reflectance standards must be taken into the field. This approach also involves simultaneous measurements with two matching instruments; however, while one instrument measures radiance from the object, the second measures irradiance directly. In this case, the input optics of the second instrument is a "cosine receptor" and the instrument is aimed vertically upward to measure Ed directly. time 1 Target, L t While this approach is appealing, cross-calibration of the two instruments is complicated by the fact that they are measuring different quantities. Crosscalibration is insured since the instruments are calibrated in absolute units. The absolute A target, L t time 2 B B Standard, L s E d = πl s / ρ s Figure 2: Measuring reflectance with a pair of matching radiometers (radiance meters). A Irradiance, E d Figure 3: Measuring reflectance with a radiance meter for Lu and a cosine irradiance meter for Ed.

CEE 6100 Remote Sensing Fundamentals 3 calibration, however, must also be checked frequently which generally requires shipping the instrument back to the factory periodically. REFERENCES Bachmann, C. M., Montes, M. J., Parrish, C. E., Fusina, R. A., Nichols, C. R., Li, R.-R., Fry, J. C. (2012). A dual-spectrometer approach to reflectance measurements under sub-optimal sky conditions. Optics Express, 20(8), 8959 73. http://doi.org/10.1364/oe.20.008959

CEE 6100 Remote Sensing Fundamentals 4 Reflection Measurements (Using the Ocean Optics spectrometers and goniometer). The tasks for this lab are to: A. Evaluate the assumption of Lambertian reflectance from a reflectance standard using a fixed illumination and varying the observation angle. B. Using the Lambertian Assumption, make spectral reflectance measurements of several targets using Procedure 1 (described on the previous pages). It is not necessary to measure absolute radiance. Reflection is expressed as a percentage relative to the reflection from a reflectance standard: %RR = VV tt (λλ, θθ) VV dddddddd (λλ, θθ) 100% (3) VV ss (λλ, θθ) VV dddddddd (λλ, θθ) where VV ss is the sample value (voltage, current, digital counts) at wavelength λλ observed when viewing the reflectance standard, and VV dddddddd and VV tt are the corresponding values for dark current and the target. This should be exactly equivalent to a radiance reflectance: RR rrrrrr = LL vv LL ii, where LL ii is the radiance incident on the target and LL vv is the radiance viewed at the detector. Note: If the reflected radiance is the same in ALL directions then we may computed the Remote Sensing Reflectance by dividing the radiance reflectance by π, i.e., RR RRRR = %RR/π. Equipment: a. Spectrometer: Ocean Optics USB2000. b. Goniometer: This is the peculiar-looking metal structure on the table. It is designed to allow precise observations at specific viewing & illumination angles. c. Fiber optic probe: The metal-clad, bifurcated cable is the fiber optic. One end is connected to a lens mounted on the goniometer, the other end bifurcates with one arm attaching to the spectrometer and the other attached to a light source. d. Reflectance standards: There are several reflectance standards available for use: 98% Barium Sulfate (in the cardboard box), 50% Spectralon (in the wooden box) and 18% (gray plastic material on a plexiglass base). e. Light sources: There is the LS-1, a calibrated irradiance source (the small blue box attached to one arm of the cladded fiber optic probe), and a full spectrum lamp mounted on a tripod on the table. Both provide radiation over the VNIR spectral range. Setting up the spectrometer: 1. On the computer, if the OceanView software is not already running: a. Double click on the OceanView icon in the upper right corner of the screen. b. Select OK or simply close the Welcome Screen. There are 3 spectrometers. We will only need one. Select Schematic Window on the left sidebar. Right Click on ADUDO181_1 and select Delete. Repeat the action for ADUDO181_2. Only the second spectrometer ADUDO181_3 should remain.

CEE 6100 Remote Sensing Fundamentals 5 2. Check the set up a. Turn on the LS-1 lamp. (To provide stable illumination, a lamp should be on for several minutes at least. We will be using this lamp for alignment, not measurements, so the short warm-up time should be sufficient.) b. Adjust the probe in the goniometer until you see a ring of 6 circles in clear focus. c. Position the Spectralon 98% reflectance standard on the jack stand and adjust the position. For the directional measurements to work properly, the target must be at the origin of the arc. To check this we use a light source passing through the fiber optic. If the target is at the correct height, the illuminated spot will change shape, but not shift position as the angle of the goniometer changes. In this case, when the goniometer viewing position is at 0 you should see six circles at the focal point of the lens. As the goniometer arm is moved to larger angles, the shape of the spots should become ellipses but the center point of the array should not shift. That is the observation point. If the center of the pattern shifts, then the standard panel is either too high or too low. d. Push the probe into the mount (a lens) as far as it will go. Take note of the size of the illuminated area at various angles. You will need to have a sense of this later. e. Turn off the LS-1 lamp. 3. Turn on the full spectrum lamp. It should warm up for a few minutes in order for its output to stabilize. We use the flood lamp to provide an essentially uniform illumination over a large area of the reflectance standard. 4. Adjust the room lights. Close the blinds, turn off the room lights and make sure the door is closed. We cannot eliminate all the extraneous light, but we can at least minimize it. 5. Position the reference reflectance panel. Place the Spectralon 98% reflectance panel in the center of the goniometer viewing area. 6. Manually set the integration time. The integration time is the length of time the detector is active. The idea is to maximize the S/N without saturating the detectors. a. Select Acquisition Group Window on the left sidebar. b. Manually set the integration time (near the top of the window) so that the peak intensity of the signal is between 3500-4000 counts. The optimal integration time will probably be in the range of 5-25 ms. The spectral curve should respond immediately. c. Insure that there is no saturation. If there is reduce the integration time. 7. Set the number of scans averaged. The spectrum is still quite noisy. The S/N can be improved by averaging a number of scans. In the Control Console, increase the number of scans averaged to 10 or more. (I like ~30). Observe the improvement in S/N.

CEE 6100 Remote Sensing Fundamentals 6 8. Set the boxcar width. This is the number of adjacent detectors that will be averaged for each observation. It is a spectral average. 9. Close the Acquisition Group Window window. (Click on the side tab.) Set up for Reflectance measurements 1. Select the OceanView symbol at the upper left of the window. 2. In the Spectroscopy and Application Window, select Reflectance, check the radio button for Active Acquisition, and then select Next. 3. Check the integration time, scan average and boxcar average and adjust as needed in order to produce a reference spectrum that is on scale and relatively noise free. Then click on Next. 4. Collect a reference spectrum. This is the spectrum of the reflectance standard. a. Position the reference panel on the goniometer. b. With the full-spectrum lamp providing reasonably uniform illumination of the reflectance panel, click on the store reference spectrum icon. Then click Next. 5. Collect a dark current a. Cover the input optics with the felt pad. b. With the input optics blocked, click on the store dark current icon. Then click Finish. c. Remove the felt pad. d. You should see a flat line at 100% reflectance from 400-1000 nm with noise at either end. 6. Adjust the spectral range to 400-1000 nm. a. Select the icon to manually adjust the display range b. Set the minimum and maximum of the x-axis to 400 and 1000, respectively. Experiment A: Evaluate the assumption of Lambertian reflectance from a reflectance standard with a fixed illumination but with varying observation angles 1. Begin with the detector observing reflectance at nadir. The spectrum should be spectrally flat at 1.0. There will be some noise, especially at the extremes of the wavelength range, but there should be no spectral features. 2. Click on the graph. This will bring up useful annotation at the bottom, including the wavelength of the vertical green line and the reflectance at that marker.

CEE 6100 Remote Sensing Fundamentals 7 3. Pick a reference wavelength near the center of the plot (~700 nm). Insert 700 in the Wavelength box at the bottom of the graph and hit Return. The vertical green (reference) line should move to the nearest wavelength observed by the spectrometer (the center of the waveband of a single detector). The magnitude of the function at that point will appear in red toward the center of the bottom of the graph. 4. Record the value on the graph below at the angle of zero (x-axis). 5. Repeat the observations by positioning the detector at multiple angles both toward and away from the light source. Collect and plot enough points on the graph below. A 100% reflectance line at all viewing angles (the ideal), and a cosine falloff patter are plotted for reference. 1.2 1.0 0.8 % reflectance 0.6 0.4 0.2 0.0-90 -80-70 -60-50 -40-30 -20-10 0 10 20 30 40 50 60 70 80 90 Viewing angle (degrees) How well does this material meet the assumption of Lambertian (perfectly diffuse) reflectance?

CEE 6100 Remote Sensing Fundamentals 8 Experiment B: Observe the spectral reflectance of a selection of color targets. The procedure is basically the same as in Experiment A. a. Update the reference spectrum and dark current on the toolbar. b. Collect reflectance measurements (at nadir) for several different-colored targets. c. Move the reflectance standard, place one of the blocks on the scissors jack, and use the block as a platform to observe the spectral reflectance of (flat) objects in the room. There are several colored folders on the table. Make sure they are at the correct height! Note where there are maxima and minima for the different materials. Does this make sense in terms of what you see visually? d. Explore! i. Some of the folders have a very flat (matte) finish. Are those Lambertian? ii. iii. iv. Some of the folders have a glossy finish and would have a strong specular component. How do the reflectance spectra vary with viewing angle? Look at the spectra of other objects: cloth, tape, skin,.. Look at the transmission of the filters (please handle the filters by the edges, and avoid touching the glass.)