ONErack patent pending Installation Guide

Similar documents
1T-CL-322-EU 15-button Wall Plate. Control Keypad 1T-CL-322-US 16-button Wall Plate Control Keypad. User Guide V1.5

Power Supply and Fan Module Installation

Encoder-100 Streaming Media Encoder

TRC-190 User s Manual

Contents. BMS icom Manual

OPERATING AND SERVICE MANUAL SPECIAL SUPPLEMENT

Encoder-100 Streaming Media Encoder

Control Keypad 1T-CL-322-US 16-button Wall Plate Control Keypad

Installing the Cisco SFS 3504 Server Switch

C3-540 CORIOmaster C3-510 CORIOmaster mini C3-503 CORIOmaster micro CORIOgrapher V2.4

TRC-190 User s Manual

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Power Supply Installation

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

EMS Electrical Management System

User's Guide. Model W 3-in-1 Switching DC Power Supply

ExpressCard Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure. September 22, 2014

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

EMS Electrical Management System

SUN2000-(2KTL-5KTL)-L0. Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

NPort S8000 Series Quick Installation Guide

Model BB9 RS-232 Multi-Drop Box. Operating Bulletin. Innovative Flow and Pressure Solutions. Standard 8 pin Mini-DIN Connector

ETC Installation Guide

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

TT-NRM. Network Relay Module Installation Instructions WARNING:

Installing the Cisco AS5400XM Universal Gateway

8-port 10/100Base-TX Switch (INS-806) User s Guide

Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA. User's Manual

LED. Sign Module. Assembly Manual

Verizon Wiring Manual PowerShift. 10 January 2018

RH-8 Headphone Station. Installation Guide

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

Register your product and get support at CEM2000. Quick Start Guide

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

ATMOX Power Supply ATMOX AC Adapter with Plugs. Wiring Guide

INJ-24A Series Quick Installation Guide

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

Power Supply and Fan Module Installation

Single cable kit for the FCB1010

Replacing the Power Supply

Instruction Manual. Hanatek (PIRA) Rub Tester. Model RT3 (Obsolete 2009)

EnerSure Installation Guide

E1135C PDU and Pod Upgrade Procedure

Panduit Basic Rack PDU

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

(Cat. No P1) Installation Data

SynchLink Board for PowerFlex 700S Drives with Phase II Control

Installation Data. The 1771 OB module can control the following output devices: dc motor starters indicators solenoids

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

RIK-5A Flexible Current Tranformer User's Manual

RMB Peripheral Units Installation Guide

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Panduit Basic Rack PDU with Local Meter

DEEP SEA ELECTRONICS PLC

TCNM-ACBB1 Installation Manual

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Speaker Selectors Models SSW-L4 EX and SSW-L6 EX. User Manual. SSW-L4 EX (bottom) and SSW-L6 EX (top)

Network Controller. Installation/Troubleshooting Instructions NK220 COM1131C

Dark Energy Survey Detector Head Electronics Crate Disassembly & Modular Replacement Instructions For Type 2 DAQ & Heater Crates

Chameleon Labs Model CPS-501 Powered Chassis

(Catalog Numbers 1394-FK10TS and -FK22TS)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

RZ2 BioAmp Processor. Operator s Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

VIEW. SLX300 SpeakerLinX. Installation and Setup Guide. AVoIP

Standard Strip Series

IDG-B Enclosures for Industrial and Building Automation Controls.

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

SYSTIMAX imvision impower Power Extender Installation

TeleAdapt Roomcast. Installation Guide TA-2400

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Liebert IntelliSlot Relay Card

AB Spares. Installation Data

PT-7728/7828 Quick Installation Guide

Installation Manual. Table of Contents

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Microsystems. SCI-6 Sound Card Interface Kit Version 1.09 January 2015

H704-42(H)(E), H704-42/1(H)(E)

A0319. Bluetooth Wall-Dock for Distributed Audio. Intelligent Entertainment Infrastructure Security Solutions

NPort 6150/6250 Series Quick Installation Guide

Megatouch FORCE Monitor Chassis Board Replacement

hp uninterruptible power system r12000 xr models installation instructions

Mondo TC. Quick Reference & Setup Guide

Installation Job Aid for Ethernet Routing Switch 5900 Series

Upgrade Instructions Printer Terminal Holder

Nokeval. FD100 series. User Manual

Loosen these screws 2 full turns Step 4: Carefully flip over the console and loosen the 3 screws in blue below: NOTE: DO NOT remove the 3 screws.

Upgrading and Servicing Guide

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Upgrading and Servicing Guide

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

2 in 1 LAN Tester and Multimeter Model:

Jippo Play - Installation Manual Page 1 INSTALLATION MANUAL. Intro Camera Operation Installation - Wrangler JK... 2

Transcription:

ONErack patent pending Installation Guide ONErack module MNL-1RK-MOD v1.10

Tools Pozidriv PZ2 crosshead screwdriver 2 mm flathead screwdriver Wire cutter Wire strippers Voltmeter In the box Optional: Self-adhesive hook and loop Scissors Cable ties Third-party mounting hardware 1 ONErack module, including voltage selector 1 Daisy-chain cable 2 Guide rails 1 Rear dock 3 Power connectors 4 M3 screws In the unlikely event that a component is missing or damaged, please contact tech.usa@tvone.com or tech.europe@tvone.com 2 ONErack

About ONErack modules The innovative ONErack module enables you to efficiently mount multiple devices. The module provides adjustable voltage and supports many ways to mount devices and secure cables. When you add a second voltage selector, you can provide two voltage options to devices mounted on the module. Secured with screws Space for optional second voltage selector Voltage selector Secured with self-adhesive hook and loop Secured with cable ties Tips for mounting your devices When you choose how to place your devices: Make sure you have enough cable to be able to access any sources, for example, Ethernet or external power. Allow enough cable to pull the module forward so you can access your devices. If your cables are short, consider mounting the device further back on the module. Make sure you allow enough room around each device for ventilation. tvone 3

Powering ONErack modules ONErack modules are designed to work with the ONErack internal power supply, but there are other options you could use pass-through power or an external power supply. ONErack internal power supply The internal power supply works with the voltage selector to give you seven DC voltage options: 5 V @ 7 A 13.5 V @ 2.6 A 7.5 V @ 4.7 A 18 V @ 1.9 A 9 V @ 3.9 A 24 V @ 1.5 A 12 V @ 2.9 A ONErack pass-through power If the voltage your device needs is not available from the voltage selector, then you can connect your device s power supply through the dock. You can then supply power to multiple devices, but at a fixed voltage. You can use a power supply up to 24 V @ 1.5 A. External power supply If you don t want to cut your power lead, you can bypass the dock and connect your power supply directly to your device. With this method you can only provide power to a single device. 4 ONErack

Fitting ONErack modules overview This installation guide assumes you have already built a ONErack chassis and fitted an internal power supply, or chosen an alternative power supply. For more information, see Powering ONErack modules on page 4, and the installation guides for the chassis and internal power supply. 1. Mount one or more devices on your ONErack module. We recommend that you mount at least your tallest device. p3 2. Fit the guide rails and insert the module. p6 3. Fit the dock and secure it with two M3 screws. Use the p6 module as a guide to align the dock. 4. Optional: fit all your remaining modules. 5. Mount any remaining devices, select a voltage, then p7 connect and secure your device cables. 6. Insert the module and power on the ONErack system. tvone 5

Fitting the guide rails and dock To avoid damaging your ONErack, build it in a clean, tidy area. Before you fit the guide rails and dock, mount at least your tallest device on the ONErack module. This helps you to determine the positions of the modules. If you intend to fit several modules at once, fit each one with the tallest device for that module. 1. Clip the guide rails into the lower and upper mounting rails. Use the numbers to help you fit the guide rails straight and in line with one another. Make sure the groove is on the right when you look from the front of the chassis. 2. Slide the module into the groove in the guide rails. 3. Screw the module in place temporarily with one or two M3 screws. 4. At the rear of the chassis, push the dock into the voltage selector. Use the module to help you align the dock. 5. Screw the dock in place with two M3 screws. 6 ONErack

Connecting cables Before you connect your cables, finish mounting your devices. Connecting your devices to the internal power supply Connecting your devices to pass-through power Connecting your devices to external power p7 p10 p12 Connecting your devices to the internal power supply Risk of damage to equipment Make sure you set the voltage selector to the correct value for your device or devices. Do not connect two devices that need different voltages to the same voltage selector. If you have devices that need different voltages, fit a second voltage selector or use a second ONErack module. Do not rotate the voltage selector switch when the ONErack system is powered. Before you cut any power leads, record the polarity and voltage for each one with a suitable meter. Before you connect any rewired DC power connector to any device, check that the polarity and voltage match what you recorded before you cut the power lead. Remove your device s power lead from the mains supply before you cut the cable. Cutting power leads should only be done by competent, qualified personnel if in doubt, consult a qualified electrician. The internal power supply can supply up to 200 W to a single daisy-chain, or up to 250 W across two daisy-chains. Do not overload the internal power supply. If the internal power supply is overloaded, it will not start. Each module can supply up to 35 W. Do not overload the modules. tvone 7

1. Remove the screws holding the ONErack module in place and remove the module. 2. Undo the screws on top of the voltage selector and remove the cover. 3. Turn the switch inside the voltage selector until the white dot points to the right voltage for your devices. 4. Cut the power lead for your device. Make sure you leave enough length to reach the voltage selector. 5. Strip the insulation from the ends of the wires and identify which is positive and which is negative. 8 ONErack

6. Insert the stripped ends into the power connector. Make sure that the polarity is correct, as shown, before you tighten the screws. 7. Insert the power connector into the voltage selector. 8. Use a long daisy-chain cable to connect the internal power supply to the module. When you connect further modules, use the shorter daisy-chain cables to connect the output of the last dock to the input of the next dock. 9. Check that all your devices are connected with the correct voltages. 10. Connect the internal power supply to the mains system and check that your devices work correctly. 11. Connect your module to the dock and screw it in place. tvone 9

Connecting your devices to pass-through power Risk of damage to equipment Before you cut any power leads, record the polarity and voltage for each one with a suitable meter. Before you connect any rewired DC power connector to any device, check that the polarity and voltage match what you recorded before you cut the power lead. Remove your device s power lead from the mains supply before you cut the cable. Cutting power leads should only be done by competent, qualified personnel if in doubt, consult a qualified electrician. Each module can supply up to 35 W. Do not overload the modules. 1. Undo the screws on top of the voltage selector and remove the cover. 2. Move the jumper from INT POWER to EXT POWER. Any power connected to the voltage selector now bypasses the voltage selector switch. 10 ONErack

3. Cut the power lead for your device. Make sure you leave enough length to reach the voltage selector. 4. Strip the insulation from the ends of the wires and identify which is positive and which is negative. 5. Insert the stripped ends into the power connector. Make sure that the polarity is correct, as shown, before you tighten the screws. 6. Insert the power connector into the voltage selector. 7. Repeat step 5 for the other piece of the power lead. 8. Disconnect the module from the dock. 9. Check that all your devices are connected with the correct voltages. tvone 11

10. Insert the power connector into the dock. 11. Plug the power lead into the mains supply. If the STATUS LED is green, the polarity is correct. Proceed to the next step. If the STATUS LED is red, the polarity is not correct. Repeat step 7. If the STATUS LED is orange, the power lead is for AC power and is not supported by the ONErack system. Use the external power method on page 12. 12. Connect your module to the dock and screw it in place. Connecting your devices to external power You can connect any of your devices using its own power supply. 12 ONErack

Safety Risk of damage in transit Your ONErack and devices can be damaged in transit. Do not ship the ONErack system with modules fitted. Package modules separately. You can ship modules with mounted devices. Risk of damage to equipment Make sure you set the voltage selector to the correct value for your device or devices. If you have devices that need different voltages, fit a second voltage selector or use a second ONErack module. Do not rotate the voltage selector switch when the ONErack system is powered. Record the polarity and voltage for each device s DC power lead with a suitable meter. Remove each device s power lead from the mains supply before you cut the cable. Cutting power leads should only be done by competent, qualified personnel if in doubt, consult a qualified electrician. Each daisy-chain cable is protected by an 8 A fuse. Do not overload the cables. The internal power supply can supply up to 200 W to a single daisy-chain, or up to 250 W across two daisy-chains. Do not overload the internal power supply. If the internal power supply is overloaded, it will not start. Each module can supply up to 35 W. Do not overload the modules. tvone 13

Contact us www.tvone.com info@tvone.com tvone NCSA North, Central and South America 2791 Circleport Drive, Erlanger, KY 41018, USA Tel +1 859-282-7303 Fax +1 859-282-8225 Sales: sales@tvone.com Support: tech.usa@tvone.com tvone EMEA Europe, Middle East, Africa and Asia Pacific Continental Approach, Westwood Industrial Estate, Margate, Kent, CT9 4JG, UK Tel +44 (0)1843 873311 Fax +44 (0)1843 873312 Sales: sales.europe@tvone.com Support: tech.europe@tvone.com Information in this document is subject to change without notice. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or any means electronic or mechanical, including photocopying and recording for any purpose other than the purchaser's personal use without the written permission of tvone. Copyright 2016 tvone. All rights reserved. 14 ONErack