Product and functional description

Similar documents
Product and functional description

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and functional description

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and functional description

Product and functional description

Product and Application Description

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Push Button Interface UP 220D31

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and Applications Description

584 5WG AB_1 DELTA

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and functional description

Push button UP 287, 4 - fold

DELTA profil wall switch, single UP 241/2 5WG AB_2

DELTA i-system wall switch single UP 221/2 5WG AB_2

252F 5WG FB_1 DELTA

Weather station AP 257/51

Weather station GPS AP 257/61 Weather station AP 257/51

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

1-channel shutter actuator 6A UP Installation Instructions

Product and function description

Product and Function Description

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Operating and mounting instructions

Product and Application Description

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Operating voltage Maximum

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

UNIVERSAL DIMMER DIM02SA/500U

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

picture 1: Device components

Power supply module, bus connection module

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Extension module for lighting control

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

The LED display (1) turns green when the load is switched on.

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Operating instructions Evaluation system for flow sensors VS / / 2013

Electrical devices may only be mounted and connected by electrically skilled persons.

Miniature Circuit Breakers for Railway Applications

Digital input modules

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Operating Instructions. DALI-Gateway

Operating instructions only for authorized, skilled electricians with EIB training

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Operating Instructions

TXM1.8RB. TX-I/O Blinds module

Solid State Remote Power Controller E /627

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

CC COMPACT DIP SWITCH

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED CONVERTERS 48 V

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

PHOENIX CONTACT - 07/2006

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

Demonstration Case BENNING DB 1

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

KNX USB INTERFACE UIMtp

6173 AG GJB A0138

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Operating instructions. Standstill monitor A / / 2011

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Power supply CP-C 24/5.0

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

Surface-Mounting Product Ranges

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Room unit with PPS2 interface

QUINT-PS/ 1AC/24DC/ 5

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Power Supply HARTING pcon

Room automation station

Electrical Actuators

QUINT-BUFFER/24DC/24DC/40

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

Non-communicating room controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Electrical Actuators

Transcription:

Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box. The bus is connected via a bus terminal block. The actuator electronics are supplied via the bus voltage. The UP 525/03 can switch and dim resistive loads (e.g. incandescent lamps, high voltage halogen lamps), capacitive loads (e.g. low voltage halogen lamps with intermediate electronic transformers), or inductive loads (e.g. low voltage halogen lamps with intermediate conventional transformers). Protection against over-load / short-circuit After about 5 seconds in an over-load condition the universal dimmer turns itself off permanently. At the earliest 2 minutes after an over-load or short-circuit tripping the dimmer may be turned on again. First send an off or a dimming value =0 command to turn the device off and then turn it on again by sending an on or a dimming value > 0 command. In a short-circuit condition the dimmer turns the load off for 3 seconds and automatically tries to switch the output on to the currently set dimming value once within 1 minute. If the short-circuit condition still persists the output is turned off permanently. Turn the output on again by following the instructions for a permanently turned off output in an over-load condition. Protection against over-temperature In case the maximum permissible temperature is exceeded the dimmer dims down to the minimal dimming value. If after 2 minutes the dimmer has cooled down sufficiently, it automatically dims back to the currently set dimming value. If after 2 minutes the maximum permissible over-temperature is still exceeded, the output is turned off permanently. Turn the output on again by following the instructions for a permanently turned off output in an over-load condition. Immunity to ripple control signals and electrical grid frequency fluctuations In the ex-factory settings the influence of ripple control signals is compensated to reduce flickering of the lamp. This measure increases the influence of electrical grid frequency fluctuations on the brightness of the lamp. A mostly undisturbed operation for an electrical system without a synchronous connection to the electrical grid can be achieved when the ripple control compensation is disabled via the associated parameter. The dimmer becomes less sensible to frequency fluctuations in the electrical system. Yet, ripple control signals will lead to an increased flickering of the load. Behavior at bus voltage failure / recovery On bus voltage failure the current switching status and dimming values are saved for restoration on bus voltage recovery. On bus voltage recovery the configured actions are executed and, if applicable, new status values are reported. Building site function The building site function provided ex-factory enables switching the building site lighting on and off via bus wall switches and actuators, even if these devices have not yet been commissioned with ETS. Behavior on unloading the application program When the application program is unloaded with ETS the device does not function. Resetting the device to ex-factory settings When the programming button is pressed for more than 20 seconds the device is reset to the ex-factory settings. All configuration settings are lost. The building site function is re-activated. The device is configured and commissioned with the ETS (Engineering Tool Software) version ETS3 v3.0f or later. Siemens AG UP 525/13, page 1 / 6 Technical manual Control Products and Systems Siemens AG 2012 Update: http://www.siemens.com/gamma P. O. Box 10 09 53, D-93009 Regensburg Subject to change without further notice 2.5.1.20/1

instabus KNX Bus coupling unit GAMMA instabus Application Program The UP 525/03 Universal dimmer with mounting frame needs the application program "07B0 A1 Universal dimmer 982C01. Example of operation Dimmer UP 525/13 N L Dimming AC 230V 3 2 1 Load circuit AC 230 V L1 N figure 1: Example of operation Lamp e. g. Incandescent lamp Installation instructions The device may be used for permanent interior installations in dry locations within flush-mount boxes. V DANGER The device must be mounted and commissioned by an authorized electrician. A safety disconnection of the device must be possible. There mustn t be any switching actions at the load output. The device may be mounted to switch and socket combination box mounts provided VDE-certified devices are used exclusively. The device must not be opened. Use only transformers that allows dimming operations. Conventional transformers may be used, if they are VDE-certified and if they have a thermic fuse. Running magnetic transformers at no load is prohibited both on start-up and in operation, because this may lead to damage to the device (even when the dimmer has cut off). This is to be ensured by connecting at least two lamps or transformers in parallel to an output. Failed lamps are to be replaced immediately. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. When looping through the L-conductor, take care that the maximum permissible terminal load current of 16A is not exceeded! Connecting inductive and capacitive or resistive loads at the same time to the same dimmer output is not permitted and leads to damage or destruction of the universal dimmer! Technical manual UP 525/13, page 2 / 6 Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2012 Control Products and Systems Subject to change without further notice P. O. Box 10 09 53, D-93009 Regensburg 2.5.1.20/2

Technical Data Power supply via the bus line and the mains connection (AC 230V) KNX bus voltage: DC 24V (DC 21...30V) via KNX/EIB bus line KNX bus current: < 10 ma Load output rated voltage: AC 230 V, 50/60 Hz rated current: 1,1A rated power consumption at 35 C ambient temperature: 10...250 VA (inductive) 10...210 VA (capacitive) 5 210 W (resistive) maximum power consumption of devices connected in relation to the ambient temperature: Max. Anschlussleistung [%] 100 90 80 70 60-5 5 15 25 35 45 Umgebungstemperatur [ C] Physical specifications: housing: plastic dimensions (L x W X D): 52 x 50 x 41,5 mm weight: approx. 55 g fire load: approx. 1000 kj Montage: Einbau in Gerätedosen 60mm, 60mm tief Electrical safety fouling class (according to IEC 60664-1): 2 protection (according to EN 60529): IP 20 overvoltage class (according to IEC 60664-1): III bus: safety extra low voltage SELV DC 24 V the device complies with EN 50428 Electromagnetic compatibility complies with EN 50428 Environmental specifications climatic conditions: EN 50090-2-2 ambient temperature operating: - 5... + 45 C ambient temperature non-operating: - 25... + 70 C relative humidity (non-condensing): 5 % bis 93 % Reliability Failure rate: 408 fit at 40 C Markings KNX EIB CE mark complies with the EMC regulations (residential and functional buildings), and low voltage regulations Control elements 1 learning button: for switching between normal operating mode and addressing mode Display elements 1 red LED: for monitoring bus voltage and for displaying normal mode / addressing mode Connections Bus line : screwless bus connection block (red-black) 0.6 0.8 mm Ø single core, strip insulation 5mm Load circuit: screwless terminals 0.5... 2.5mm² single-core, stranded or multi-core, untreated, strip insulation 9... 10mm Siemens AG UP 525/13, page 3 / 6 Technical manual Control Products and Systems Siemens AG 2012 Update: http://www.siemens.com/gamma P. O. Box 10 09 53, D-93009 Regensburg Subject to change without further notice 2.5.1.20/3

Location / Function of the Display and Operating Elements Mounting and connecting General description The connection to the bus line is established via bus connection block 193 (screwless plug-in terminals for single core conductors). Mounting B1 wall box (60 mm Ø, according to DIN 49073) B2 Actuator figure 3: Mounting figure 2: Location / Function of the Display and Operating Elements A1 LED for indicating normal operating mode (LED off) or addressing mode (LED on); returns to normal operating mode automatically after receiving the physical address A2 Learning button for switching between normal operating mode and addressing mode and for receiving the physical address A3 Type label (with space for physical address of the actuator) A4 clamping slots for anchoring the bus lines A5 Snap-on cover for bus line and single bus wires A6 Bus connection block for single core conductors with 0,6...0,8 mm Ø A7 Terminal Channel A A8 Distance plate A9 Terminal L A10 Distance plate A11 Terminal N A12 Label with terminal descriptions A13 Identification number of the device Slipping off/on bus connection blocks The bus terminal block (C2) is situated on the side of the actuator (C3). It consists of two components (C2.1 and C2.2) with four terminal contacts each. Take care not to damage the two test sockets (C2.3) by accidentally connecting them to the bus cable or with the screw driver (e.g. when attempting to unplug the bus terminal block). Slipping off bus connection blocks - Put the screw-driver between the cover (C1) and the actuator (C3) from the side and lever out the cover. - Carefully put the screw driver to the wire insertion slit of the bus terminal block s grey component (C2.2) and - pull the bus terminal block (C2) from the Actuator (C3). Note Don t try to remove the bus connection block from the bottom side. There is a risk of shorting-out the device! Technical manual UP 525/13, page 4 / 6 Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2012 Control Products and Systems Subject to change without further notice P. O. Box 10 09 53, D-93009 Regensburg 2.5.1.20/4

Slipping on bus connection blocks - Slip the bus connection block (C2) onto the guide slot of the actuator (C3) and - press the bus connection block (C2) down to the stop. - press the sheathing of the cut-off insulation bus line projecting >3mm into the open clamping slot (C4). If a further bus line shall be connected break out the closed clamping slot with a screw-driver and press it into the clamping slot as described above. Press the single bus wires into the recess below the bus connection block and snap on the cover (C1) Connecting/disconnecting mains and load circuit: Connect wires - The load circuits are connected via screwless plug-in terminals (E1). - Remove approx. 9 10 mm of insulation from the wire (E 1.1) and plug it into the terminal (E1). - The terminals are designed for connection of two wires allowing to loop through the terminal block. Note: The maximum permissible terminal load current is 16A. Remove wires - Press the terminal interlocking of the terminal (F1) with a screw-driver and remove the wire (F2) from the terminal (F1). C2 C2.3 C2.2 C2.1 figure 4: Slipping off/on bus connection blocks Connecting bus cables - The bus terminal block (D2) can be used with single core conductors Ø 0.6 0.8 mm. - Remove approx. 5 mm of insulation from the conductor (D1) and plug it into the bus terminal block (D2) (red = +, grey = -) figure 6: Connecting/disconnecting mains and load circuit Disconnecting bus cables - Unplug the bus connection block (D2) and remove the bus cable conductor (D1) while simultaneously wiggling it. 25...35 mm D1 5 mm D2 D2 D2.4 D2.4 figure 5: Connecting / Disconnecting bus cables Siemens AG UP 525/13, page 5 / 6 Technical manual Control Products and Systems Siemens AG 2012 Update: http://www.siemens.com/gamma P. O. Box 10 09 53, D-93009 Regensburg Subject to change without further notice 2.5.1.20/5

Dimension drawing Space for notes Dimensions in mm General Notes The operating instructions must be handed over to the client. Any faulty device is to be sent together with a return delivery note of the local Siemens office. For any technical questions, please consult: +49 (911) 895-7222 +49 (911) 895-7223 support.automation@siemens.com www.siemens.com/automation/support-request Technical manual UP 525/13, page 6 / 6 Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2012 Control Products and Systems Subject to change without further notice P. O. Box 10 09 53, D-93009 Regensburg 2.5.1.20/6