SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

Similar documents
SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Readme SiVArc V14 SP1 Update 6

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

SIMOTION. SIMOTION SCOUT Reading and Writing Drive Data. Preface. Fundamental safety instructions 1. Description 2.

Updating SIMOTION Devices SIMOTION. SIMOTION SCOUT Updating SIMOTION Devices. Preface. Overview. Updating 2. Restoring 3.

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

PD PA AP How To Configure Maxum II TimeServer Access

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

Continuous Function Chart Getting. Started SIMATIC. Process Control System PCS 7 Continuous Function Chart Getting Started.

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

Siemens Automation Products

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

SIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System

COMOS. Lifecycle 3D Integration Operation. Publisher 1. COMOS PDMS Integration 2. Material management 3. COMOS 3D viewing 4.

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Basic Functions for Modular. Machines SIMOTION. Motion Control Basic Functions for Modular Machines. Preface

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Settings. Prior information notice 1. Introduction to "Settings" 2. User rights in "Settings" 3. Settings interface 4.

Optional package printer driver V1.4

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

COMOS. Operations MRO. Introduction 1. Maintenance objects 2. "General maintenance" plugins 3. "Events" plugin 4. "Resources" plugin 5

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

COMOS. Lifecycle 3D Integration Operation. COMOS PDMS Integration 1. Material management 2. COMOS 3D viewing 3. References 4.

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

COMOS. Lifecycle 3D Integration Operation. COMOS PDMS Integration 1. Material management 2. COMOS 3D viewing 3. References 4.

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

First Steps with S7-PDIAG and ProAgent

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Web Option for OS (V8.0) SIMATIC. Process Control System PCS 7 Web Option for OS (V8.0) Preface 1. Additional documentation

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication

COMOS. Automation Logical. Basic principles 1. Configuring function diagrams based on IEC 2. Code generation based on IEC

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

SIMATIC NET. S TeleControl MSC300_Library program block library. Block library for TCSB (V3) WDC_S7_300_... (FB92) 2 UDT_WDC_PARAM (UDT91) 3

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

COMOS. Lifecycle COMOS Walkinside Getting Started. Security information 1. Which functionalities are not covered in this manual? 2

SIMATIC. Working with STEP 7. Introduction to STEP 1. The SIMATIC Manager 2. Programming with Symbols. Creating a Program in 4

Basic principles 1. Configuring function diagrams based on IEC 2. Administration 3 COMOS. Automation Logical. Operating Manual 04/2015 A5E AD

Siemens Controls. SAP interface COMOS. Platform SAP interface. Trademarks 1. Introduction. Technical prerequisites 3

Portable & Direct COMOS. Operations Portable & Direct. Trademarks 1. Introduction. Portable 3. "Direct" plugin 4. User interface reference

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

Examples for SIMATIC IPC Support. Package for VxWorks SIMATIC. Industrial PC Examples for SIMATIC IPC Support Package for VxWorks

SIMATIC HMI. WinCC V7.4 WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Improvements in Openness 4. Readme. Readme

COMOS Material Management. Operation COMOS. Process COMOS Material Management Operation. Trademarks 1. Introduction. Definitions 3

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

SFC Visualization (V8.0 SP1) SIMATIC. Process Control System PCS 7 SFC Visualization (V8.0 SP1) What's new in SFV? 1. SFC Visualization (SFV)

COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

Sample project Filling Station SIMATIC. STEP 7 Professional / WinCC Advanced V11 for Sample project Filling Station. Overview of the Getting.

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

Counting, measurement and position. detection SIMATIC. S7-1500, ET 200MP, ET 200SP Counting, measurement and position detection.

Transcription:

Preface 1 Overview 2 SIMOTION Motion Control Configuring 3 Working with the SIMOTION Task Profiler 4 Function Manual Valid as from Version 4.4 04/2014

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY P 04/2014 Subject to change Copyright Siemens AG 2014. All rights reserved

Table of contents 1 Preface...5 1.1 SIMOTION Documentation...5 1.2 Hotline and Internet addresses...5 2 Overview...7 3 Configuring...9 4 Working with the SIMOTION Task Profiler...13 4.1 Starting the SIMOTION Task Profiler...13 4.2 Structure of the SIMOTION Task Profiler...16 4.2.1 Structure of the interface...16 4.2.2 Structure of the menus...17 4.2.3 Global toolbar...18 4.3 Opening a...19 4.4 Control of r...19 4.5 Analyzing a...20 4.6 Saving the trace data...22 4.7 Find...22 Index...25 Function Manual, 04/2014 3

Preface 1 1.1 SIMOTION Documentation An overview of the SIMOTION documentation can be found in the SIMOTION Documentation Overview document. This documentation is included as electronic documentation in the scope of delivery of SIMOTION SCOUT. It comprises ten documentation packages. The following documentation packages are available for SIMOTION V4.4: SIMOTION Engineering System Handling SIMOTION System and Function Descriptions SIMOTION Service and Diagnostics SIMOTION IT SIMOTION Programming SIMOTION Programming - References SIMOTION C SIMOTION P SIMOTION D SIMOTION Supplementary Documentation 1.2 Hotline and Internet addresses Additional information Click the following link to find information on the the following topics: Ordering documentation / overview of documentation Additional links to download documents Using documentation online (find and search manuals/information) http://www.siemens.com/motioncontrol/docu Please send any questions about the technical documentation (e.g. suggestions for improvement, corrections) to the following e-mail address: docu.motioncontrol@siemens.com Function Manual, 04/2014 5

Preface 1.2 Hotline and Internet addresses My Documentation Manager Click the following link for information on how to compile documentation individually on the basis of Siemens content and how to adapt it for the purpose of your own machine documentation: http://www.siemens.com/mdm Training Click the following link for information on SITRAIN - Siemens training courses for automation products, systems and solutions: http://www.siemens.com/sitrain FAQs Frequently Asked Questions can be found in SIMOTION Utilities & Applications, which are included in the scope of delivery of SIMOTION SCOUT, and in the Service&Support pages in Product Support: http://support.automation.siemens.com Technical support Country-specific telephone numbers for technical support are provided on the Internet under Contact: http://www.siemens.com/automation/service&support 6 Function Manual, 04/2014

Overview 2 Field of application The SIMOTION supports you when troubleshooting in the SIMOTION multitasking environment. The SIMOTION records the sequence of individual tasks, identifies user events that you can generate via a program command, and displays these graphically. This makes the interaction between programs and tasks easily traceable, thereby affording better control over them. Function Manual, 04/2014 7

Overview Structure of the The SIMOTION includes two main components: The SIMOTION r, which writes the task change and events to a buffer on the target device The SIMOTION Task Profiler, an application for displaying the recorded data Figure 2-1 Schematic representation of SIMOTION SIMOTION IT DIAG (standard web pages) is used to configure the SIMOTION r. The recording data is saved as a JEN file on the memory card of the target device. If you start the Task Profiler via the device diagnostics, the trace data is automatically read from the memory card via the online connection and displayed. Alternatively, you can also save the JEN file from the target device to the file system of the PC using the SIMOTION standard web pages and then open the file in the SIMOTION Task Profiler. 8 Function Manual, 04/2014

Configuring 3 Overview Configuring the SIMOTION r is only necessary in exceptional circumstances, as the default configuration is used for recording. If you require a different configuration than the default, with Version V4.1.2 and higher this can be carried out on the target device via the standard web pages (SIMOTION IT DIAG). Note The functionality must be activated in the SIMOTION SCOUT project in the hardware configuration of the CPU. You can activate the required services in the hardware configuration on the "Ethernet extended/webserver" tab in the object properties of the CPU. Note The changes you make to the configuration using the standard web pages remain in effect until the next time the target device is powered up. Following power-up, the default settings and the settings in the SIMOTION.ini file apply. SIMOTION IT DIAG (standard web pages) Configuration and control functionality of the r are available on the standard web pages of SIMOTION IT DIAG. Use the Open IT Diag button to start the standard web pages in the SCOUT device diagnostics. Note If there is no Ethernet connection from SCOUT to the target device, the button is deactivated (grayed out). Function Manual, 04/2014 9

Configuring Figure 3-1 SIMOTION IT DIAG standard web pages - (part 1) Figure 3-2 SIMOTION IT DIAG standard web pages - (part 1) Default configuration The following table summarizes the default configuration of the r and the setting options (configuration and control) using the standard web pages of the target device or the SIMOTION.ini file. Note The SIMOTION.ini is not created automatically and may need to be created and stored in the root directory of the memory card. Note For additional information regarding the configuration and status displays using standard web pages, refer to the "SIMOTION SCOUT Overview about Service and Diagnostic Options" documentation. 10 Function Manual, 04/2014

Configuring Table 3-1 Default configuration of the r Variable name in SIMOTION.ini TT_BUFSIZE TT_WROUT TT_RSTRTOFF TT_LEVEL TT_TRIGGER TT_TRGDELAY Meaning Default setting Can be changed via IT- Diag standard web pages Size of the trace buffer in KB Activate automatic writing of the trace data to the memory card after the trace has stopped TT_WROUT =1 Trace is not started automatically after the trace data is written to the memory card TT_RSTRTOFF=1 Mask for specifying the events that are to be recorded in the Task Trace (see "Masking of events to be recorded") TT_LEVEL=0x0040 Mask for specifying the stop trigger of the trace (see "Masking of STOP trigger") TT_TRIGGER=0x0001 Delay time [ms] after the trigger event until is stopped 512,000 bytes (the maximum setting depends on the available RAM) The trace data is not written automatically to the memory card (Because this is a default setting, no entry in the SIMOTION.ini) The trace is started automatically once the trace data has been written to the memory card (Because this is a default setting, no entry in the SIMOTION.ini) 0x0040 (User_Events) 0x0001 No Additional Trigger Settings: Enable automatic writeout after triggered stop Additional Trigger Settings: Enable automatic restart after writeout Level Settings Trigger Events or Trigger Mask 0 ms Trigger Delay Masking of events to be recorded Level masks: 0x0040 user events made by the user program Masking of STOP trigger Trigger masks: 0x0001 stop on overflow of a cyclic task 0x0002 stop on leaving BZ STOPU, aiming STARTUP 0x0004 stop on reaching BZ RUN 0x0008 stop on leaving BZ RUN Function Manual, 04/2014 11

Configuring 0x0010 stop on reaching BZ STOP or STOPU, coming from SHUTDOWN 0x0020 stop on reaching BZ STOP, coming from INIT 0x0040 stop on leaving BZ INIT 0x0100 stop on Download-Begin 0x0200 stop on Download-End You can also combine masking instances if required, for example 0x0009 from 0X0001 stop on overflow of a cyclic task and 0x0008 stop on leaving BZ RUN. Creating the SIMOTION.ini file The following example shows how you can modify the configuration using the SIMOTION.ini file. In this process, it should be specified that the CPU mode will be recorded until it changes to STOP mode. The buffer size is specified as 1,000,000 bytes. The automatic writing of the trace data to the memory card is activated once the trace has stopped. Example: TT_BUFSIZE = 1000000 TT_TRIGGER= 0x0010 TT_WROUT=1 Note The maximum buffer size depends on the available memory capacity of the RAM and the memory card. 12 Function Manual, 04/2014

Working with the SIMOTION Task Profiler 4 4.1 Starting the SIMOTION Task Profiler You can open the SIMOTION Task Profiler as an application from the STEP7 program folder or from the SCOUT device diagnostics. Start via STEP7 program folder You can open the SIMOTION Task Profiler as an application in the STEP 7 program folder (see figure below). Figure 4-1 Opening the Task Profiler in the STEP7 program folder When the Task Profiler is closed, the settings (e.g. most recently loaded recording) are not saved. On reopening, the window for the display is empty (see figure below). Function Manual, 04/2014 13

Working with the SIMOTION Task Profiler 4.1 Starting the SIMOTION Task Profiler Figure 4-2 SIMOTION Task Profiler upon opening via the STEP7 program folder Start using SCOUT device diagnostics Note In order to start the device diagnostics, an online connection to the target device must exist. Start the Task Profiler in the device diagnostics as described below: 14 Function Manual, 04/2014

Working with the SIMOTION Task Profiler 4.1 Starting the SIMOTION Task Profiler 1. Switch to the Task Manager tab. 2. The following options are available: Click the Display button. The Task Profiler starts. In addition, the trace file is loaded from the memory card of the target device and opened in a new tab in the Task Profiler. If you click the button again, the same file is read again. Click the Create snapshot button. The setting that you have made using IT-Diag is reset to the default state. The settings made using the SIMOTION.ini file are retained. The is started, written to the memory card, and then the Task Profiler started. If you click the button again, a new recording is started. Note If a trace file is not stored on the CF card of the target device, a new tab for the display is not shown. Figure 4-3 Start of Task Profiler via the device diagnostics Function Manual, 04/2014 15

Working with the SIMOTION Task Profiler 4.2 Structure of the SIMOTION Task Profiler 4.2 Structure of the SIMOTION Task Profiler 4.2.1 Structure of the interface The structure of the SIMOTION Task Profiler is described below. Figure 4-4 Structure of the user interface of the Task Profiler No. Description 1 Menu bar: File, Edit, Options, Help 2 Global toolbar 3 Tab with current trace. Several traces can be opened simultaneously. 4 Local toolbar 5 Display of T-measurement cursor 6 Time markings of the timing diagram 7 Labeling of user events 8 Display of task names 9 System tasks not displayed individually 10 Status bar 11 Marking of user events in the timing diagram 12 Timing diagram of tasks 13 Quick search 16 Function Manual, 04/2014

Working with the SIMOTION Task Profiler 4.2 Structure of the SIMOTION Task Profiler 4.2.2 Structure of the menus The menus are explained below. For more detailed information, refer to "Working with the SIMOTION Task Profiler". File menu Figure 4-5 File menu Table 4-1 Entries in the File menu Entry Open... Close... Save As... Print... Recent trace Exit Description Opens the JEN file Closes the current Trace tab Saves the current trace Prints the current trace Selection of the most recently opened trace recordings Exits the Task Profiler Edit menu Figure 4-6 Edit menu Table 4-2 Entries in the Edit menu Entry Find Find Next Find Previous Description Opens the Find Options dialog box Searches for the next event corresponding to the Find Options Searches for the previous event corresponding to the Find Options Function Manual, 04/2014 17

Working with the SIMOTION Task Profiler 4.2 Structure of the SIMOTION Task Profiler Options - Menu Figure 4-7 Options - Menu Table 4-3 Entries in the Options menu Entry User Event Configuration Description Opens the dialog for assigning names to the user events of the current recording. You can export the configuration as an XML file and, if required, import it. Help menu Figure 4-8 Help menu Table 4-4 Entry Help About Entries in the Help menu Description Opens the Help system Opens the About dialog box 4.2.3 Global toolbar The following functions are available in the global toolbar: Table 4-5 Icon Global toolbar Function Open Saves under a different name Print Browses for events Open help For a description of the functions of the local toolbar, refer to "Analyzing a ". 18 Function Manual, 04/2014

Working with the SIMOTION Task Profiler 4.4 Control of r 4.3 Opening a Proceed as follows to open a trace file (trace stored on the PG/PC): 1. Open the Open... dialog from the File > Open menu Figure 4-9 Open 2. Select the JEN file you want to open in the Task Profiler, and confirm with Open... 4.4 Control of r Control You can control the r using SIMOTION IT DIAG (standard web pages) of the target device or with system functions in the user program. Note For additional information, refer to the "Technology Packages System Functions" and "SIMOTION SCOUT Overview about Service and Diagnostic Options" documentation. Function Manual, 04/2014 19

Working with the SIMOTION Task Profiler 4.5 Analyzing a System functions in the user program The following table provides an overview of the available system functions: System function _tasktraceuserevent _tasktracestop _tasktracestart _tasktracewriteout Description This function enters an event with a user-defined ID from 0 to 255 in the buffer of the SIMOTION r. This function stops an active r recording. This function starts the recording. Note: When the function is called, whether or nor the r has already been started is irrelevant. If the r is active after the call, the function supplies 0 as return value. The function stops a recording that is already in progress and saves the Trace data as a JEN file (ttrace.jen) on the target device memory card under the following path: /USER/SIMOTION/HMI/SYSLOG/TASKTRACE/ DIAG 4.5 Analyzing a Note Peaks can occur during the recording, which indicate whether they can be re-started by means of background task testing. These peaks are irrelevant to the analysis. The following options are available for analyzing the trace recording and for modifying the view: 20 Function Manual, 04/2014

Working with the SIMOTION Task Profiler 4.5 Analyzing a Control via the local toolbar Table 4-6 Functions of the local toolbar Icon Description Open the Graph Settings dialog. You can show or hide tasks and specify the color for each task in this dialog. Open the statistics. This dialog provides an overview of the tasks available in the system and their status at the end of the trace. Go to start of trace. Go to end of trace. Open the Go To dialog. You can use this dialog to jump to the entered time value. Zoom In Zoom Out Function Manual, 04/2014 21

Working with the SIMOTION Task Profiler 4.7 Find Icon Description Zoom factor can be entered (between 1 and 5,000). Fast search using User Event or Task Switch Control via the mouse Table 4-7 Functions via mouse or shortcut Click button or shortcut Right-click event icon Left- or right-click Description Info box on selected event. Generates a red or green vertical guide line, at whose upper end the time is displayed in ms. The values are displayed in the following information panel. Shift + left- or right-click Ctrl + left-click Ctrl + right-click Right-click task name Removes the red or green guide line. Generates a horizontal guide marking. This can also be generated by directly left-clicking the task name. Removes the horizontal marking. Clicking the currently selected task name also removes the horizontal marking. Info box for corresponding task. 4.6 Saving the trace data The recorded trace data is stored as a JEN file (ttrace.jen) on the memory card of the target device under the following path: /USER/SIMOTION/HMI/SYSLOG/TASKTRACE/DIAG To save trace data under a different name, follow the procedure described below: 1. Open the Save As dialog from the File > Save As.. menu. 2. Enter the desired file name and save it. If a file of the same name already exists, it is overwritten. If required, you can use a card reader to read out the JEN files on the memory card. 4.7 Find You can use the find function (can be invoked in the main menu using Edit > Find) to search for the next user event or the next task in the trace recording. If you are searching for a specific event or task, you must also specify the event ID or the task designator. You can use the Find Previous or Find Next button to search backwards or forwards, respectively. 22 Function Manual, 04/2014

Working with the SIMOTION Task Profiler 4.7 Find Figure 4-10 Find Event Figure 4-11 Find Task Function Manual, 04/2014 23

Index Structure SIMOTION, 8 D Default configuration r, 10 F Field of application SIMOTION, 7 G Go To, 21 Graph Settings, 21 M Masking Events, 11 STOP trigger, 11 R References, 5 S SIMOTION Task Profiler, 8 Starting via STEP7 program folder, 13 SIMOTION Field of application, 7 Structure, 8 SIMOTION.ini, 12 Statistics, 21 System functions, 20 Function Manual, 04/2014 25