Siemens BACnet Programmable TEC Unit Conditioner Controller

Similar documents
Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Siemens BACnet Programmable TEC Unit Vent Controller

Siemens BACnet Programmable TEC Constant Volume

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

BACnet Terminal Box (VAV) Controller

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Siemens BACnet VAV Actuator

BACnet Protocol Implementation Conformance (PIC) Statement

Dual Duct Controller - One Air Velocity

PXC Compact Series on BACnet/IP

TC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1, July 31, 2008

oom Pressurization Con

PXC Modular Series for BACnet Networks

BACnet PTEC Controller Heat Pump Multi-Stage Slave Mode, Application Application Note Building Technologies

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

TB7300 Series Fan Coil Unit Communicating Thermostats BACnet Protocol Implementation Conformance Statement (PICS)

BACnet PTEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies

TEC Unit Conditioner Controller

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

BACnet PTEC Unit Conditioner/Fan Coil P. Controller. Control Applications. Accessories. Product Description. Warning/Caution Notation

TC Modular Series for BACnet Networks

TEC Terminal Box (VAV) Controller

Maverick I Commercial Packaged Rooftop Systems Unit Controller Protocol Implementation Conformance Statement (PICS) ANSI/ASHRAE , BACnet

BACnet PTEC Terminal Box (VAV) Controller. Control Applications. Product Numbers. Product Description. Warning/Caution Notation

TALON Network Manager- 2 & 6 Express

TC Compact Series Unitary Equipment Controller

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

BACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement

Andover ContinuumTM. b3850 Series Terminal Controllers

Compact Series Unitary Equipment Controller

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Delta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

BACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603

Actuator Commissioning Tool

Delta Controller Engine (DCE) Firmware

WT-BAC-IP Gateway Protocol Implementation Conformance Statement

NB-VAV Family Protocol Implementation Conformance Statement (PICS)

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Heatronic Introduction. BAS Integration Manual. Table of Contents

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.)

Field selectable application type and room module series, via dip-switches on controller

Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement

ESAC ebacgw SNMP. Date: Mar 08,2009. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

FXVMA Variable Air Volume (VAV) Box Controller

RWD68U Universal Controller

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

BACnet Driver on the TC Series Platform

Sales and Engineering Data Sheet ED

TC-9102 Terminal Controller

TEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.

BACnet. b3867 Terminal Controllers

TEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation

NB-V3Tb Protocol Implementation Conformance Statement (PICS)

NXAC-120 Area Controller

Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement

Underfloor Controllers

NB-ASC Family Protocol Implementation Conformance Statement (PICS)

VZ7000 Series. BACnet Commercial Zoning System

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

entelibus CPU Engine (eb-eng) Firmware

1. BACnet Protocol Implementation Conformance Statement

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

System Controls Suggested Specification

BACnet IP for Quantum

SHEET. BASgatewayLX Modbus to BACnet Gateway. BASgatewayLX

1. BACnet Protocol Implementation Conformance Statement

SCC Inc. TS-D Series. Technical Instructions. Document No. TS-3000 March 10, Deaerator, Surge and/or Condensate Control Panel.

IQ4NC/.../ BACnet PICS

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

NS Series Temperature and Humidity Network Zone and Discharge Air Sensors Protocol Implementation Conformance Statement

Delta ORCAview Date: August 5, 2009 Vendor Name: Delta Controls Inc. Product Name:

TC Compact Series for BACnet Networks

TAC Xenta 121-FC Programmable Fan Coil Application

BACnet Protocol Implementation Conformance Statement

Room Pressurization Controller Pneumatic Output

TX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

ECB-VAVS. Features and Benefits. Applications Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Room Pressurization.

SEZ7000 Series. Wireless Commercial Zoning System

PXC Compact Unitary Equipment Controller BACnet Protocol Implementation Conformance Statement

BACnet. b3810 Series Local Controllers

Room Pressurization Controller Electronic Output

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

MS/TP Point Pickup Module Owner's Manual

FX Server BACNET AWS Protocol Implementation Conformance Statement

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

Transcription:

Technical Specification Sheet Document No. 149-831 September 24, 2014 Siemens BACnet Programmable TEC Unit Conditioner Controller Returns from power failure without operator intervention. No calibration required, thereby reducing maintenance costs. PID control of HVAC systems to minimize offset and maintain tighter setpoint control. Unique control algorithms for specific applications. The Siemens BACnet PTEC Unit Conditioner Controller provides high performance Direct Digital Control (DDC) of pressure-dependent boxes, fan coil units, and induction units. The Siemens BACnet PTEC Conditioner Controller can operate stand-alone or can be networked to perform complex HVAC control, monitoring and energy management functions and is designed to reside on any BACnet control system. Features Communicates using BACnet MS/TP protocol for open communications on BACnet MS/TP networks. BTL listed as a B-ASC device. Programmable using PPCL. Plenum rated controller. Setpoints and control parameters assigned and changed locally or remotely. Setpoints and control parameters stored in Electrically Erasable Programmable Read Only Memory (EEPROM) no battery backup required. Separate minimum and maximum air volume setting for heating and cooling modes. User adjustable offset for the room temperature reading when required for validation purposes. Applications Pressure Dependent Terminal Boxes Cooling or Heating (Application 6540) Hot Water Heat (Application 6541) Fan Coil Units Cooling or Heating (Application 6550) Cooling and Heating (Application 6551) Two-stage Cooling and Electric Heat (Application 6552) Two-stage Cooling and Hot Water Heat (Application 6553) Cooling and Electric Heat or VAV Pressure Dependent with Electric Heat (Application 6554) Control algorithms are preprogrammed. The controller is ready to operate after selecting the application. If desired, the operator may adjust the room temperature setpoints and other parameters. The Page 1 of 5

controller is designed for operation and modification without vendor assistance. If required, new custom code using our PPCL programming language can be added to replace or supplement the standard application residing in the controller. This provides the flexibility to meet many job specifications with the assurance of having a proven and tested standard application to rely upon. Hardware Controller Board The Siemens BACnet PTEC Unit Conditioner Controller consists of an electronic controller assembly. The controller interfaces with the following external devices: Floating control valve and damper actuators Temperature sensors (room, pipe, and duct) Service and commissioning tools Digital input devices (dry contacts from motion sensors, alarm contacts, switches) Digital output devices (fan speeds, stages of heat, stages of cooling) Room Sensor The room sensor connection to the controller board consists of a quick-connect RJ-11 jack. This streamlines installation and reduces controller start-up time. Combination Temperature and Relative Humidity Models The Series 2200 range of TEC room units includes combination temperature and humidity models. For these models, both temperature and relative humidity values are passed digitally to the TEC. This information is passed from the room unit through the RJ-11 cable to the RTS port on the TEC. See the Series 2200 Temperature Room Units for TEC and ATEC Technical Specification Sheet (149-820), for more information. Unit Conditioner Controller Specifications Dimensions Weight Controlled Temperature Accuracy, Heating or Cooling Power Requirements Operating Range Power Consumption Power Requirements Operating Range Power Consumption Inputs Analog Digital Outputs Analog Digital Communications 4-1/8" W 11-1/4" L 1-1/2" H approx. 3 lbs (1.35 kg) ±1.5 F (0.9 C) 19.2 to 27.6 Vac, 50 or 60 Hz 10 VA (plus 12 VA per DO) 19.2 to 27.6 Vac, 50 or 60 Hz 10 VA (plus 12 VA per DO) 1 room temperature sensor 1 setpoint (optional) 2 auxiliary temperature sensors (10 K thermistor) 1 selectable 0-10 Vdc/4-20 ma 2 dry contacts 3 0-10 Vdc 8 DO 24 Vac optically isolated solid state switches @ 0.5 amp Remote BACnet MS/TP (EIA 485), 9600 bps to 76800 bps FLN Trunk Local WCIS and PTEC Tool Page 2 of 5

Ambient Conditions Shipping & Storage Temperature Operating Temperature Humidity Range -13 F to 158 F (-25 C to 70 C) 32 F to 122 F (0 C to 50 C) 5% to 95% rh (non-condensing) Document Information Technical Specification Sheets/Technical Instructions Room Temperature Sensors Series 2200 Document Part Number 149-820 Agency Listings UL Listing cul Listed UL 916, PAZX Canadian Standards C22.2 No. 205-M1983, PAZX7 FCC Compliance 47 CFR Part 15 BTL Listed as a B-ASC device Duct Temperature Sensor 149-134P25 Low Limit Detection Thermostat 155-016P25 Analog Sensors 10 K Ohm Thermistor 149-912, 149-915, and 149-916 Siemens Valves and Electronic Actuators 599 Series Zone Valves 2-Way, 3-Way Zone Valve Electric and Thermic Actuators 155-034 Ordering Information 599 Series Zone Valves and Actuators Modulating, On/Off Spring Return, 2- Position Control 155-063 Description Siemens BACnet PTEC Fan Coil Controller Large enclosure for electronic controller without damper actuator (long board). Part Number 550-496P 550-002 Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. or company names mentioned herein may be the trademarks of their respective owners. 2014 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA Tel. 1 + 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com. Document No.149-831 Printed in the USA Page 3 of 5

BACnet Protocol Implementation Conformance Statement s Model Number Protocol Software Firmware Siemens BACnet PTEC Unit Conditioner Controller 550-496P 4 (135-2004) 2.0.5.1 BF43 Date Tested: July 2011 B-ASC Vendor Information Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 www.buildingtechnologies.siemens.com/bt/us Description The controller is an integral part of Siemens controls system. The controller can operate stand-alone or can be networked to perform complex HVAC control, monitoring, and energy management functions. This controller communicates using BACnet MS/TP. BACnet Standardized Device Profile Device Profile Tested PTEC BACnet Application Specific Controller (B-ASC) Supported BACnet Interoperability Building Block (BIBBs) BIBB Name Tested PTEC DS-RP-B Data Sharing-ReadProperty-B DS-RPM-B Data Sharing-ReadPropertyMultiple-B DS-WP-B Data Sharing-WriteProperty-B DM-DDB-B Device Management-Dynamic Device Binding-B DM-DOB-B Device Management-Dynamic Object Binding-B DM-DDC-B Device Management-DeviceCommunicationControl-B DM-RD-B Device Management-ReinitializeDevice-B DM-BR-B Device Management-Backup and Restore-B DM-OCD-B Device Management-Object Creation and Deletion-B Page 4 of 5

Standard Object Types Supported Object Type Creatable Deletable PTEC Analog Input No No Analog Output Yes Yes Binary Input No No Binary Output Yes Yes Device No No File Yes Yes Program Yes Yes Data Link Layer Options Data Link and Options MS/TP master (Clause 9), baud rate(s): 9600 bps, 19200 bps, 38400 bps, 76800 bps MS/TP slave (Clause 9), baud rate(s): 9600 bps, 19200 bps, 38400 bps, 76800 bps Segmentation Capability Segmentation Type Supported Window Size: 32 (MS/TP product limited to 1) Able to transmit segmented messages No Able to receive segmented messages No Device Address Binding Static Device Binding Supported Yes Networking Options Static Device Binding Supported No Character Sets Charcter Sets Supported ANSI X3.4 Page 5 of 5