SIEMENS CERN EN/ICE annual meeting

Similar documents
WinAC RTX 2010 Getting Started. Getting-started. Edition ( )

Turn on and immediately start with the engineering! siemens.com/simatic-pg

SIMATIC S7-PLCSIM Advanced V1.0. Simulation with TIA Portal V14 and PLCSIM Advanced

SIMATIC WinAC - PROFINET/ Ethernet PROFIBUS. Windows. Time Synchronization. MATIC NET SOFTNET-S7 Lean SIMATIC NET OPC -

PLC COURSE LIST NMU TRAINING CENTRE

Welkom bij het Webinar Industrial Automation

SIMATIC PC-based controller

Multi Panel options. SIMATIC WinAC MP 2/169

SIMATIC. Windows Automation Center RTX WinAC RTX Introduction 1. Product overview 2. Installation 3. Getting started 4

PC-based Control Open, flexible and reliable. Product Brief February 2004

TIA Portal V15. The digital revolution

Operator control and monitoring systems PC-based Automation

Cover sheet. Application Operations Diary. WinCC Flexible 2008 SP1. Application Description June Applications & Tools. Answers for industry.

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

The SIMATIC ET 200SP Open Controller: The compact PC-based controller from the S series siemens.com/open-controller

Training and Seminars

General information. Display. Control elements

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)


SCE Training Curriculum for the end-to-end automation solution Totally Integrated Automation (TIA)

Cut down your costs, increase your productions efficiently with the knowledge of PLC s Siemens technology. SITRAIN TM THAILAND Page 1 of 13

TFT widescreen display, LED backlighting Screen diagonal Number of colors Resolution (pixels) Horizontal image resolution.

SIMIT Simulation. Optimize your plant, increase your competitiveness

General information. Display. Control elements

Data Synchronization between Head and Field PLCs with Storage of the Process Values in CSV Files

Connecting a PC Station to an S using OPC

SIMATIC HMI Panels. Technical Data. siemens.com/hmi. Answers for industry. Engineered with TIA Portal

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014


This extract is provided for your convenience only. Copyright 2017 nbn co limited. All rights reserved. Not for general distribution.

SIMATIC IPC227D Bundles, SIMATIC. IPC277D Bundles SIMATIC. Embedded Automation SIMATIC IPC227D Bundles, SIMATIC IPC277D Bundles.

Cover sheet. Help for Planning Plants with PCS 7 OPC DA SIMATIC PCS 7 OPC DA. FAQ March Service & Support. Answers for industry.

Service & Support. Data Communication between S7 Station and PC Station, using SIMATIC NET OPC Server SIMATIC S7. Function description March 2013

Advanced Process Functions V2.0

Faculty of Technology, Department of Electrical Engineering, Information Technology and Cybernetics. SCADA System

Cover. WinAC Command. User documentation. V1.5 November Applikationen & Tools. Answers for industry.

Documentation QuickHMI First Steps

Training document for the company-wide automation solution Totally Integrated Automation (T I A)

Sitrain. Training which combines theory and practice. Complete training catalogue. Innovation for generations.

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

SIMATIC. Process Control System PCS 7 V7.0 SP1 Software Update With Utilization of New Functions (PCS 7 V6.x to V7.0 SP1) Preface.

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

SIMATIC Virtualization as a Service Efficient for Virtualization. Unrestricted Siemens AG 2018

SIMATIC IPC847D 1/5. Copyright Siemens AG 2014

SCE Training Curriculum for the end-to-end automation solution Totally Integrated Automation (TIA)

Exchange of large data volumes between S control system and WinCC

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)


Totally Integrated Automation (T I A) MODULE A1 Totally Integrated Automation (T I A)

Siemens Safety Integrated Take a safe step into the future

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory


Learn-/Training Document

Automation systems. Scalable performance for every requirement

General information Customer-specific configuration

Configuration Control with the S and ET 200SP

SIWAREX. SecureDisplay. SIWAREX SecureDisplay 1/22 A5E A

Applications & Tools. Communication between WinAC MP and a SIMATIC S7. Application for the PUT and GET Function Blocks of the S7 Communication

View the most recent product information online

PROFINET/Industrial Ethernet Controllers / Modular controllers / SIMATIC S7-400

Operator Interfaces to suit all requirements. Product Brief

SIMATIC. Process Historian 2014 SP2 SIMATIC Process Historian. Process Historian - Installation Notes 1. Process Historian - Release Notes

General information. Display. Control elements

SIMATIC ET 200SP and ET 200MP

General information. Supply voltage. Input current

Siemens AG PC-based Automation

General information Customer-specific configuration

Raising the standard Upgrading the Series 90-30

General information. Supply voltage

Scada Siemens Manual READ ONLINE

General information. Configuration control. Display. Control elements. Supply voltage

SIMATIC. PCS 7 Process Control System CFC Readme V9.0 SP2 Upd2 (Online) Security information 1. Overview 2. Notes on Installation 3.

Product type designation

Product type designation. General information. Supply voltage

Configuration of an MRP Ring and a Topology with Two Projects

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Operator panels Advanced HMI Panel-based Mobile Panels

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Supply voltage. Input current

Overview of DCS Technologies. Renaud Barillère - CERN IT-CO

General information. Display. Control elements

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Communication between HMI and Frequency Converter. Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120. Application Example 04/2016

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

SIMIT. Notes on Installation and Usage. Software disclaimer for simulation products. Security information

Software for SIMATIC controller

SIMATIC Virtualization as a Service Efficient for Virtualization. Unrestricted Siemens AG 2018

Lukasz Zwalinski PH/DT

General information. Configuration control. Display. Control elements. Supply voltage

STEP 7 PROFESSIONAL. Function STEP 7

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

Configuration of an MRP ring with SIMOCODE and SIMATIC S SIMOCODE pro V PN, SIMATIC S Siemens Industry Online Support

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

Display of SINAMICS Fault Messages in WinCC V7.4

Automatic Visualization of the Sample Blocks in WinCC Advanced

Cover. WinAC AccessDB V2. Operator manual. V 2.01 February Applikationen & Tools. Answers for industry.

Transcription:

SIEMENS CERN EN/ICE annual meeting Nuremberg, December the 13 th 2012 * Critical in the sense of fast intervention

Outline Purpose Follow-up problems Follow-up and participate in product evolution Meeting structure Software usage and purchase statistics Technical and commercial issues Technical presentations * Critical in the sense of fast intervention

Siemens software usage and statistics YEAR USERS Purchase ( KCHF) SOFTWARE USAGE (number of PCs running the software) STEP 7 MICROWIN WINCC FLEXIBLE HIGRAPH CFC S7-PDIAG SimaticNET 1998 - - - - - - - - - 1999-404 - - - - - - - 2000-850 - - - - - - - 2001 22 964 - - - - - - - 2002 82 676 - - - - - - - 2003 107 949 144-7 - - - - 2004 149 1414 179-54 - - - - 2005 151 3321 228-57 - - - - 2006 172 2930 192 5 95 - - - - 2007 190 1955 161 5 103 - - - - 2008 242 1077 169 9 64 2 4 9-2009 238 1215 206 22 89 1 8 9-2010 246 992 228 23 90 1 11 16-2011 260 1246 275 25 112 3 12 23 55 2012 282 1171 322 28 185 3 15 34 68 * Critical in the sense of fast intervention

CERN Users 300 USERS 250 200 150 USERS 100 50 0 * Critical in the sense of fast intervention

Siemens equipment purchase 3500 Purchase ( KCHF) 3000 2500 2000 1500 Purchase ( KCHF) 1000 500 0 * Critical in the sense of fast intervention

Siemens software usage 350 300 250 200 STEP 7 WINCC FLEXIBLE MICROWIN SimaticNET 150 100 50 0 * Critical in the sense of fast intervention

Commercial Additional discount for orders above 25000 EUR. Still finding a procedure to follow in order to get this extra 4% discount. Latest years this discount has not been applied. SIMBA box. Siemens has offered a 12 % discount, far from the 25 % (average) for most of the products included in the contract. * Critical in the sense of fast intervention

Technical support HiGRAPH is out phased and not supported anymore. Special Keyword for support requests. For high priority cases Siemens offers 1000 credits Value Card to reach directly the highest level in the Siemens support line. New Siemens support webpage. Presentation to be scheduled Open Issues: RAMSES case closed and now reopened due to other problems detected. Problem handled by the external company who delivered the system WinCCOA vs. S7-1500 and S7-1200. Compatibility mode available in PVSS to connect to those PLCs by using absolute addresses. Symbolic addressing available in long term. TIA Portal migration errors. With latest version of TIA portal the migration seems to work better even if there still errors in the PID Siemens library. Touch Panel performance. Performance issues presented to Siemens. Siemens will analyse one of our projects to see what is the source of the problem.

Operator panels performance * Critical in the sense of fast intervention

HMI Many panels will be phased-out in 2014 (6 years spare parts ensured) Video support (IP cameras inside) Panels Diagnostics through the PLC (life bit) Multi Touch functionality Memory card or USB stick can load the HMI panel application Request form CERN: Diagnostic facilities to be improved.

OPC UA CERN interested in the evolution of OPC UA especially embedded in PLC. OPC UA server in redundant mode possible (only 2008 Server available).

PLC roadmap S7-1200 Significant increase of memory for S7-1200 up to 125 Kb in 2013. 2 Mb Memory card available. CAN interface available, 3 cards maximum 16 nodes each. Wi-Fi embedded for short distance (1m).

PLC roadmap S7-1500 Security increased. New S7 protocol enhanced. Old S7 protocol still supported. Small display at the front with diagnostics ad commands. Foldable, replaceable hot swap. MPI interface removed. Profinet interface by default. Two integrated Ethernet interfaces. External Ethernet cards available. With VPN. Internal archive until 26 different measurements. Hot swappable modules with active backplane. Modules not compatible with S7 300.

IPC Availability: 6 years guaranteed on the market and 5 years spare parts. Nanobox IPC227D: Intel Atom Micro: 600 MHz - 1.3 GHz Microbox IPC427D: Intel i7 1.5 GHz, Turbo boost included. CERN request: Windows embedded. Operating system updates not frequent. Windows embedded roadmap stable.

WinAC WinAC RTX runs as a driver in Windows. Siemens foresees to decouple as much as possible Windows and WinAC. Currently WinAC RTX can survive to a blue screen from Windows. (OB84 is triggered). Performance of WinAC not dependant on storage media. ODK (Open development kit) available to allow interaction between PC and controller. It can run on the real-time side of windows. WinAC RTX can run in normal PC. Simulation possible.

TIA Portal roadmap V12 end of January 2013 >> V12 SP1 in Q2 2013 >> V12.5 end of 2013 >> New version end 2014. Features V12: SCL as standard programming language for all controllers. Size of the blocks increased and bigger than 64K Versioning can be applied to libraries. Automatic update of project when library changes. Features V12.5 Importing Source files via API to import/export sources in xml format. Features version > V12.5: Object orientation (e.g. inheritance) Multiuser Versioning SVN integrated Full API to Open project, Compile, import (even hardware).

PROFINET redundancy

PROFINET redundancy

PROFINET redundancy

SIMIT Includes a Software PLC simulator which is ready to be in the market. SIMIT can interface a third party simulator tool (OPC or shared memory in the future). SIMIT focus on Simatic (simulator for automation). Templates are based on PCS7 but can be adapted (e.g. UNICOS). Symbols for the periphery to be used. UNICOS does not create symbols for I/O.