RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Similar documents
RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Heating Controllers. Siemens Building Technologies HVAC Products. Synco 700

RMZ790. Operator Unit. Building Technologies. Synco 700

TXM1.8RB. TX-I/O Blinds module

Digital input modules

Central control unit

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Air damper actuators

Super universal modules

Room Temperature Controller

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

BACnet/IP Web Interface

Heating Circuit Controller

Rotary actuators for ball valves

Fast running actuators for air dampers

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

Resistance measuring module

Immersion Temperature Sensors

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Switching and Monitoring Device

Power supply module, bus connection module

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Heating Circuit Controller

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Rotary version, three-position control

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Universal Controller

AEW Pulse Adapter. Building Technologies

Semi flush-mounted room temperature controllers with LCD

Interface converter for VAV compact controllers

Room unit with PPS2 interface

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

SEH62.1. Digital Time Switch

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Electromotive actuators for combi valves

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Extension module for lighting control

Room unit with PPS2 interface

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Room unit with PPS2 interface

Temperature controller for multi-zone ducted systems

Temperature Controller (Heat Pumps)

VAV modular controller

ERF910. RF Repeater. Synco living

Electromotoric actuators

Central Communication Unit OZW775

Network node WTT56.. A6V _en--_c Building Technologies

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Non-communicating room controllers

VAV compact controller

Room Temperature Controller

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Switching and monitoring device

Electromotoric actuators

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

Mobile Data Collector

Air Damper Actuators Modbus RTU

Room Temperature Controllers

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Air Damper Actuators Modbus RTU

Compact room automation stations, BACnet/IP, AC 230 V

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Temperature Controller

Island bus expansion module

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Rotary actuator for ball valves KNX / PL-Link

Web interface BACnet/IP

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Semi flush-mounted room temperature controllers with LCD

Universal Controllers

Electromotoric actuators for stroke valves

Compact Universal Controllers

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

OZW672...V6.0. Web-Server. For LPB/BSB plants

Temperature controller Ducted systems

Room unit with PPS2 interface

LON Module for Variable Speed Drive

Handheld Tool for VAV compact and modular controllers

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Electrical Actuators

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Electrical Actuators

M-bus RF gateway. Meters and Energy Cost Allocation WTT563-0C0000

Flush-mount room sensor

RF adapter plugs, dimming

Switching module for AC V and up to three load stages, with manual switching

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

Impulse switching module

Product and functional description

Semi Flush-mount Room Temperature Controllers with LCD

Non-communicating room controllers

Transcription:

3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled by the RH760B heating controller. For the heating controller s field of use, refer to Data Sheet N3133. Functions The universal modules are designed to increase the number of inputs and outputs of Synco 700 controls, thus providing additional control and monitoring functions. The following inputs and outputs are provided: Type reference Number of universal inputs Number of analog outputs Number of relay outputs NO Changeover RZ782B 3 1 2 1 RZ783B 4 1 3 2 Type summary Type of module Heating circuit module DHW module Type reference RZ782B RZ783B CE1N3136en 2016-01-12 Building Technologies HVAC Products

Ordering When ordering, please give name and type reference, for example: Heating circuit module RZ782B The module connector listed under "Accessories" must be ordered as a separate item, if required. Equipment combinations The extension modules must be used in connection with the RH760B heating controller. They cannot be used in connection with other controls of the Synco 700 family. For information about the heating controller RH760B, refer to Data Sheet N3133. Product documentation Type of documentation ounting Instructions Product Range Description CE Declaration of Conformity Environmental Declaration Classification number 3110 S3110 T3110 E3110 02 Technical design ode of operation The RZ78 extension modules complement the RH760B heating controller and can not operate autonomously. Use of the extension modules is determined by the selection of the basic type (basic configuration). All settings required in connection with the extension modules are made on the heating controller. The signals from sensors, signal sources, etc., are delivered to the heating controller and then handled; the control signals and commands generated by the controller are fed to the respective extension module from where they are passed on to the connected actuating devices. The extension module is powered by the RH760B heating controller, which also identifies and monitors the module. echanical design Basic design In terms of mechanical design, the extension modules are identical to the Synco 700 controls. No wiring between the modules or to the heating controller is required; the electrical connections are made by attaching the modules to the controller. Synco 700 control with attached extension module RZ78 Operation The extension modules have no setting and operating elements; operation takes place with the operator unit RZ790 or RZ791. There is one exception, the module has an LED for indicating the operating state. 2/8

Indicating and connecting elements 2 2 6 3145Z01 1 2 3 4 1 Connecting elements for the Synco 700 control or for one extension module 2 ounting facility for fitting the module to a top hat rail 3 Fixing facility for the cable tie 4 LED (green) for indication of operation 5 Connecting elements for one extension module 6 Rest for the terminal cover 6 5 Accessories Accessories Type reference Data Sheet odule connector RZ780 N3138 Engineering notes ounting and installation notes Fuses, switches, wiring and grounding must be in compliance with local safety regulations Sensor cables should not be run parallel to mains-carrying cables powering loads such as actuators and pumps The module are designed for: ounting in a standard cabinet as per DIN 43 880 Wall mounting on an existing top hat rail (EN 50 022-35 7.5) Wall mounting using two fixing screws Flush panel mounting Not permitted are wet or damp spaces; the permissible ambient temperatures must be observed Disconnected the system from the power supply prior to mounting and installation the module The module insert may not be removed from the terminal base! The module must be fitted to the right of the controller in the correct order The extension modules need not be wired between themselves or to the controller. The electrical connections are made automatically when plugging the modules. If it is not possible to arrange all extension modules side bye side, the first of the detached modules must be connected to the previous module or the controller by using the RZ780 module connector. In that case, the cumulated cable length may not exceed 10 meters 3/8

Low-voltage side ains voltage side The connection terminals for protective extra low-voltage are located in the upper half of the module, those for mains voltage (actuators and pumps) at the bottom Only one solid or stranded wire may be connected to each terminal (spring cage terminals). For fixing the wires, the cables must be stripped by 7 to 8 mm. To introduce the wires into the spring cage terminals, or to remove them, a screw driver size 0 or 1 is required. Cable strain relief can be ensured with the help of the lugs for cable ties The module mounted on the top hat rail together with other modules can only be removed from the rail after the 3 catches have been brought into their release-andhold position (audible "click"). After removal, the catches must be pushed back into their snap-on position The module is supplied complete with ounting Instructions Commissioning notes During the commissioning process, the outputs are in a defined off state. Disposal notes The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations.. Technical data Power supply Rated voltage (via the controller) AC 24 V 20 % Power consumption 3 VA Analog inputs (X ) Sensors Passive 1 or 2 (averaging) LG-Ni 1000, T1, Pt 1000, NTC 575 Active DC 0 10 V Signal source Passive 0 2500 Active DC 0 10 V Digital Inputs (X ) Contact sensing (status / counting values) Voltage DC 15 V Current 5 ma Requirements for the status and impulse contacts Signal coupling potential-free Type of contact maintained or impulse contacts Insulating strength against mains potential AC 3750 V to EN 60 730 Perm. resistance Contacts closed max. 200 Contacts open min. 50 k Positioning outputs Output voltage DC 0 10 V (Y1, Y2) Output current 1 ma ax. load continuous short-circuit 4/8

Switching outputs External supply line fusing (Q ) Non renewable fuse (slow) max. 10 A Automatic line cutout max. 13 A Release characteristic B, C, D to EN 60 898 Cable length max. 300 m Relay contact data Switching voltage max. AC 265 V / min. AC 19 V AC current (cos = 0.6) max. 4 A ohm., 3 A ind. at 250 V min. 5 ma at 19 V min. 20 ma Switch-on current max. 10 A (1 s) Contact life at AC250 V guide values: at 0.1 A res. 2 10 7 cycles at 0.5 A res. 4 10 6 cycles (N.O.) 2 10 6 cycles (changeover) at 4 A res. 3 10 5 cycles (N.O.) 1 10 5 cycles (changeover) Reduction factor at ind. (cos = 0.6) 0.85 Insulating strength Between relay contacts and system electronics (reinforced insulation) AC 3750 V, to EN 60 730-1 Between neighboring relay contacts (operational insulation) Q1 Q2; Q3 Q4 AC 1250 V, to EN 60 730-1 Between relay groups (reinforced insulation) [Q1, Q2] [Q3, Q4/Q5] AC 3750 V, to EN 60 730-1 Power supply external devices (G1) Voltage Current AC 24 V max. 4 A Electrical connections Connections terminals spring cage terminals For solid wires 0.6 mm dia 2.5 mm 2 For stranded wires without ferules 0.25 2.5 mm 2 For stranded wires with ferules 0.25 1.5 mm 2 Degrees of protection Degree of protection of housing to IEC 60 529 IP 20 (when mounted) Safety class to EN 60 730 device suited for use with equipment of safety class II Environmental conditions Operation to IEC 60 721-3- Climatic conditions class 3K5 Temperature (housing with electronics) 0 50 C Humidity 5 95 % r. F. (non-condensing) echanical conditions class 32 Transport to IEC 60 721-3-2 Climatic conditions class 2K3 Temperature 25 70 C Humidity <95 % r. F. echanical conditions class 22 5/8

Classifications to ode of operation, automatic controls type 1B EN 60 730 Degree of contamination, controls environment 2 Software class A Rated surge voltage 4000 V Temperature for ball-test of housing 125 C aterials and colors Terminal base polycarbonate, RAL 7035 (lightgray) odule insert polycarbonate, RAL 7035 (lightgray) Packaging corrugated cardboard Norms and standards Product standard EN 60730-1. Environmental compatibility Product family standard EN 50491-x Electromagnetic compatibility (application) EU conformity (CE) RC conformity EAC conformity Automatic electronic controls for household and similar use. General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS). For use in industrial and domestic environments CE1T3110xx*) CE1T3110en_C1*) Eurasia conformity The environmental product declaration contains data CE1E3110en02*) on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) *) These related documents can be downloaded at the following Internet address: http://siemens.com/bt/download Weight RZ782B excl. packaging 0.28 kg RZ783B excl. packaging 0.28 kg Connecting terminals RZ782B X1 X2 G1 X3 Q11 Q23 Q33 RZ782B G1 G0 Y1 Q12 Q14 N1 Q24 N2 Q34 3136G01 RZ783B X1 X2 G1 X3 X4 Q11 Q23 Q33 Q43 Q51 RZ783B G1G0Y1 Q12 Q14 N1 Q24 N2 Q34 Q44 Q52 Q54 3136G02 G0 System neutral for signal output G1 Output voltage AC 24 V for powering external active devices easuring neutral for signal input N Spark suppression device for 3-position actuators 6/8

Q Potential-free relay inputs and outputs for AC 24 230 V X Universal signal inputs for LG-Ni 1000, 2 LG-Ni 1000 (averaging), T1, Pt 1000, DC 0 10 V, NTC 575, 0 2500, contact sensing (potential-free) Y Control or status outputs DC 0 10 V Notes Each terminal (spring cage terminals) can accommodate only 1 solid wire or 1 stranded wire Double terminals are internally interconnected With 3-position control of actuators operating on AC 230 V, the radio interference suppression element must be activated. For that purpose, terminal N1 is to be connected to the neutral conductor and a wire link is to be fitted between terminals N1 and N2 Connection examples Heating circuit module RZ782B L B B1 3136A01 AC 24...230 V X1 X2 G1 G0 Y1 G1 X3 Q11 Q23 Q12 Q14 N1 Q24 N2 Q33 Q34 A2 N G G0 Y Y1 Y1 N Y2 Y2 1 A2 B1 1 Y1 Y2 Heating circuit module RZ782B Flow temperature sensor Heating circuit pump Actuator with DC 0 10 V input 3-position actuator DHW module RZ783B L 3136A02 B B1 B B2 AC 24...230 V X1 X2 G1 G1 G0 Y1 X3 X4 Q11 Q23 Q12 Q14 N1 Q24 N2 Q33 Q34 Q43 Q44 Q52 Q51 Q54 A3 N G G0 Y Y1 Y1 N Y2 Y2 1 A3 B1 B2 1 Y1 Y2 DHW module RZ783B DHW flow temperature sensor Storage tank temperature sensor Charging pump Actuator with DC 0 10 V input 3-position actuator 7/8

Dimensions 10,5 75 5 3 2,8 117 3 3 = 90 45 35 66,4 ø = 3 ø 5,2 44 EN 60 715-TH 35-7.5 = = 97 314501 Dimensions in mm Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2006 Technical specifications and availability subject to change without notice. 8/8