SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Similar documents
Electromotoric actuators for stroke valves

Electromotive actuators for combi valves

Electromotive actuators for valves

Electromotoric actuators

Rotary actuators for ball valves

Fast running actuators for air dampers

Air Damper Actuators Modbus RTU

Air Damper Actuators Modbus RTU

Rotary actuator for ball valves KNX / PL-Link

Electromotoric actuators

Air damper actuators

Rotary version, three-position control

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

TXM1.8RB. TX-I/O Blinds module

Electrical Actuators

Electrical Actuators

Electrical Actuators

Electromotoric actuator

Digital input modules

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Room Temperature Controller

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Super universal modules

BACnet/IP Web Interface

Semi flush-mounted room temperature controllers with LCD

Interface converter for VAV compact controllers

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

VAV Compact Controller Modbus RTU

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Immersion Temperature Sensors

VAV modular controller

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Room unit with PPS2 interface

Electromotoric actuators

Electromotoric actuators

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

SEH62.1. Digital Time Switch

VAV compact controller

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Electrical actuators

Power supply module, bus connection module

Universal Controller

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Heating Circuit Controller

Airflow Pressure Sensor

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Room unit with PPS2 interface

Handheld Tool for VAV compact and modular controllers

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Heating Circuit Controller

Products no longer available

Resistance measuring module

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

ERF910. RF Repeater. Synco living

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Extension module for lighting control

Island bus expansion module

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Climatix programmable controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

RMZ790. Operator Unit. Building Technologies. Synco 700

Room unit with PPS2 interface

Products no longer available

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET

Mobile Data Collector

Radiator Lockshield Valves ADN.. AEN..

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Semi flush-mounted room temperature controllers with LCD

AEW Pulse Adapter. Building Technologies

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Network node WTT56.. A6V _en--_c Building Technologies

Web interface BACnet/IP

Modulating controlled actuator AME 11

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

24-hour room temperature controller

Overview of types. Technical data

Actuators AME 655, 658 and 659 can be controlled by electronic controllers with modulating or 3-point control output.

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Temperature Controller (Heat Pumps)

7-day room temperature controller

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Semi Flush-mount Room Temperature Controllers with LCD

Room Temperature Controller

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Touch Panels 10.1" and 15.6"

Transcription:

s 4 501 ACVATIX Electromotive actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4 20 ma SAX81.. Operating voltage AC/DC 24 V, 3-position control signal SAX61.. Position feedback, override control, changeover of flow characteristic SAX61../MO Operating voltage AC/DC 24 V, RS485 for Modbus RTU communication For direct mounting on valves, no adjustment required Manual adjuster, position indicator and status indication (LED) Optional functional extension using auxiliary switches, potentiometer, function module, stem heating element Use To operate Siemens 2-port and 3-port valves, types V..F21.., V..F22.., V..F31.., V..F32.., V..F40.., V..F41.., V..G41.., V..F42.., VVF52.. and V..F53.. with 20 mm stroke as control and safety shutoff valves in heating, ventilation and air conditioning plants. CE1N4501en 2017-10-10 Building Technologies

Type summary Type Stock no. Stroke SAX31.00 SAX31.03 SAX61.03 SAX61.03U SAX61.03/MO S55150-A105 S55150-A106 S55150-A100 S55150-A100-A100 S55150-A140 Pos. force 20 mm 800 N Operating voltage AC 230 V AC/DC 24 V Pos. signal 3-Punkt DC 0 10 V DC 4 20 ma 0 1000 Ω Modbus RTU Spr.. ret. time - Pos. time 120 s 30 s LED - Manual adjuster Press and fix Extra functions Position feedback, forced control, changeover of characteristic curve Position feedback, forced control - SAX81.00 SAX81.03 SAX81.03U S55150-A102 S55150-A103 S55150-A103-A100 3-Punkt 120 s 30 s - - Electrical accessories Product no. Auxiliary switch ASC10.51 Potentiometer ASZ7.5 Function module AZX61.1 Stem heating element ASZ6.6 Stock number S55845-Z103 S55845-Z106 S55845-Z107 S55845-Z108 Max. 2 Max. 1 SAX31.. Max. 2 Max. 1 - SAX61.. - Max. 1 AZX61.1 Max. 1 SAX61../MO Max. 2 - SAX81.. Max. 1 - Note: ASZ7.5 For the combination SIMATIC S5/S7 and position feedback message, we recommend actuators with DC 0 9.8 V feedback signals. The signal peaks that occur in the potentiometer ASZ7.5 may result in error messages on Siemens SIMATIC. This is not the case when combined with Siemens HVAC controllers. The reason is that SIMATIC has a higher resolution and faster response time. Mechanical accessories Weather shield ASK39.1 1) 1) SAX61../MO is not suitable for exterior application 2 / 12

Ordering Example Product no. Stock no. Description Quantity SAX81.03 S55150-A103 Actuator 1 ASZ7.5 S55845-Z106 Potentiometer 1 Delivery Actuators, valves and accessories are supplied in individual packs. Spare parts Housing cover Screw (valve stem coupling) Product number / Stock number U-bracket 8000060843 Product documentation Title Contents Document ID Position actuators SAX.., SAY.., SAV.., SAL.. for valves Basic documentation: Comprehensive information on new generation actuators SAX.. CE1P4040_01en Electromotive actuators for valves SAX.. Electromotive actuators for valves SA.., Modbus RTU Mounting instructions S..6../MO and G..161../MO Data sheet: Product description SAX.. Data sheet: Communication profile Modbus Mounting instructions: Mounting and installation instructions CE1N4501 A6V101037195 A5W00027551 The documents, to include related documents such as environmental declarations, CE declaration, etc. are available for download from the following Internet address: http://siemens.com/bt/download Equipment combinations Type reference DN PN class k vs [m 3 /h] Data sheet 2-port valves VV.. (control or safety shutoff valves) VVF21.. Flange 25...80 6 1.9 100 N4310 VVF22.. Flange 25 80 6 2.5 100 N4401 VVF31.. Flange 15...80 10 2.5 100 N4320 VVF32.. Flange 15 80 10 1,6 100 N4402 VVF40.. Flange 15 80 1.9 100 N4330 VVF41.. Flange 50 19 / 31 N4340 VVF42.. Flange 15 80 16 1,6 100 N4403 VVF42..K Flange 50 80 40 100 VVG41.. Thread 15 50 0.63 40 N4363 VVF52.. Flange 15 40 0.16 25 N4373 25 VVF53.. Flange 15 50 0.16 40 N4405 3-port valves VX.. (control valves for "mixing" and "diverting" functions) VXF21.. Flange 25 80 6 1.9 100 N4410 VXF22.. Flange 25 80 6 2.5 100 N4401 VXF31.. Flange 15 80 10 2.5 100 N4420 VXF32.. Flange 15 80 10 1.6 100 N4402 VXF40.. Flange 15 80 1.9 100 N4430 VXF41.. Flange 15 50 1.9 31 N4440 16 VXF42.. Flange 15 80 1,6 100 N4403 VXG41.. Thread 15 50 1.6 40 N4463 VXF53.. Flange 15 50 25 1.6 40 N4405 3 / 12

Notes Engineering SAX31.. and SAX81.. SAX61.. SAX61../MO 3-position actuators must have their own specific controller, refer to "Connection diagrams" (page 9). Up to 10 actuators can drive in parallel on a controller output with a rating of 1 ma. Modulating actuators have an input impedance of 100 kω. The Modbus converter is designed for analog control on 0..10 V on the actuator side. Note: Keep the setting of the analog signal on the actuator as is (switch 1 to "OFF"), adjustment is not allowed. The actuators are factory-set to equal-percentage characteristic curve. Note: The DIL switch (actuator-internal changeover of characteristic curve) must be set to "log" (switch 2 to "OFF"). Mounting Mounting positions Indoor use Outdoor use 1) 1) Only together with weather shield ASK39.1 SAX61../MO is not suitable for outdoor use. Maintenance The actuators are maintenance-free. Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic waste. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Warranty The engineering data specified in "Equipment combinations" (page 3) are only guaranteed in combination with the Siemens valves listed. Note When using the actuators together with valves by other manufacturers, users are required to ensure correct functioning, and Siemens will assume no responsibility. 4 / 12

Technical data Power supply Function data Signal inputs Communication Communication protocol SAX.. Operating voltage SAX31.. AC 230 V ±15% SAX61.. AC 24 V ± 20% / DC 24 V + 20% / -15% (SELV) SAX81.. AC 24 V ±20% / DC 24 V + 20 % / -15% (SELV) Fuse slow 6 10 A Circuit breaker max. 13 A, External supply line protection (EU) Characteristic B, C, D according to EN 60898 Power source with current limitation of max. 10 A Power consumption at 50 Hz SAX31.00 Stem retracts / extends 3.5 VA / 2 W SAX31.03 Stem retracts / extends 6 VA / 3.5 W SAX61.03.. Stem retracts / extends 8 VA / 3.75 W SAX61.03/MO Stem retracts / extends 8.7 VA / 4.25 W SAX81.00.. Stem retracts / extends 3.5 VA / 2.25 W SAX81.03.. Stem retracts / extends 5 VA / 3.75 W Positioning times (with the specified nominal stroke) The positioning time can vary, depending on the type of valve -> refer chapter "Type summary" (page 2) SAX31.00, SAX81.00.. 120 s SAX31.03, SAX61.03.., SAX81.03.. 30 s Positioning force 800 N Nominal stroke 20 mm Working stroke area the actuator is able to calibrate 6.. 24 mm Permissible medium temperature (valve fitted) -25 130 C Y1 / Y2 SAX31.., SAX81.. 3-position SAX31.. Voltage AC 230 V ± 15 % SAX81.. Voltage AC 24 V ± 20 % / DC 24 V + 20 % / - 15% Y-positioning signal SAX61.. (DC 0 10 V) SAX61.. (DC 4 20 ma) Current draw 0,1 ma Input impedance 100 kω Current draw DC 4 20 ma ± 1 % Input impedance 500 Ω Modbus RTU RS-485, not galvanically isolated Number of nodes Max. 32 Address range 1...247 / 255 Factory setting: 255 Transmission formats 1-8-E-1 / 1-8-O-1 / 1-8-N-1 / 1-8-N-2 Factory setting: 1-8-E-1 Baud rates (kbaud) Auto / 9.6 / 19.2 / 38.4 / 57.6 / 76.8 / 115.2 Factory setting: Auto Parallel operation SAX61.. 10 (depending on controler output) Forced control Positioning signal Z SAX61.. R = 0 1000 Ω, G, G0 R = 0 1000 Ω Stroke proportional to R Z connected to G Max. stroke 100% 1) Z connected to G0 Min. stroke 0% 1) Voltage Max. AC 24 V ± 20% Max. DC 24 V + 20% / -15% Current draw 0.1 ma Position feedback Position feedback U SAX61.. DC 0...10 V Load impedance >10 kω res. Load Max. 1 ma Connecting cable Wire cross-sectional areas 0.13 1.5 mm 2, AWG 24 16 2) Cable entries SAX.. EU: 2 entries 20.5 mm (for M20) 1 entry 25.5 mm (for M25) SAX..U US: connection SAX61../MO Fixed connecting cable Number of cores 3 entries 21.5 mm for ½ tube Degree of protection Housing from vertical to horizontal IP54 as per EN 60529 3) (see "Mounting") Insulation class As per EN 60730 Actuators SAX31.. AC 230 V II Actuators SAX61.. AC / DC 24 V III Actuators SAX81.. AC / DC 24 V III Environmental conditions Operation IEC 60721-3-3 Climatic conditions Class 3K5 Mounting location Indoors (weather-protected) 3) Temperature Genera -5 <55 C Humidity (noncondensing) 5 95% r.h. 0.9 m 5 x 0.75 mm 2 5 / 12

Transport IEC 60721-3-2 Climatic conditions Class 2K3 Temperature -25 70 C Humidity <95% r.h. Storage IEC 60721-3-1 Climatic conditions Class 1K3 Temperature -15 55 C Humidity 5 95% r.h. Max. media temperatur when mounted on valve 130 C Standards and directives Product standard Electromagnetic compatibility (application) EN 60730-x EU conformity (CE) CE1T4501X1 4) RCM conformity CE1T4515X4 4) EAC conformity SAX.. For residential, commercial and industrial environments Eurasian conformity for all SAX.. UL, cul AC 230 V - AC/DC 24 V UL 873 http://ul.com/database Environmental compatibility The product environmental declarations 7173310559Ben 4) and A6V101083254 4) contain data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). imensions See "Dimensions" (page 10) Accessories 5) Potentiometer ASZ7.5 0 1000 Ω ± 5% Voltage DC 10 V Current rating <4 ma Auxiliary switch ASC10.51 Switching capacity AC 24 230 V, 6 (2) A, potential-free External supply line protection See "Power supply" US Installation, UL & cul AC 24 V class 2, 5 A general purpose Stem heating element ASZ6.6 Power supply Power consumption Inrush current (cold) 1) Note the direction of control action of the DIL switch 2) AWG = American wire gauge AC/DC 24 V, ± 20% 40 VA / 30 W Max. 8,5 A (max. temperature 85 C / 185 F) 3) Always together with weather shield ASK39.1 for outdoor use, housing IP protection IP 54 as is SAX61../MO is not suitable for outdoor use. 4) Documents available at http://www.siemens.com/bt/download 5) UL recognized component 6 / 12

Connection diagrams Internal diagrams SAX31.. Accessories B and / or A 1x ASC10.51 1x ASC10.51 or 1 x ASZ7.5 SAX61.. AC/DC 24 V G 4...20 ma DC 0...10 V AC/DC 24 V 0...1000 Ω Y Z Accessories B and / or A M G0 100% 0% U M DC 0...10 V 1x ASC10.51 1x ASC10.51 SAX61../MO AC 24 V / DC 24 V SAX81.. Accessories B and / or A 1x ASC10.51 1x ASC10.51 or 1 x ASZ7.5 7 / 12

Connection terminals SAX31.. AC 230 V, 3-position Sytem neutral (SN) Positioning signal (actuator s stem extends) Positioning signal (actuator s stem retracts) SAX61.. AC/DC 24 V, DC 0 10 V / 4 20 ma / 0 1000 Ω Sytem neutral (SN) Sytem potential (SP) Positioning signal for DC 0 10 V / 4 20 ma Measuring neutral Position feedback DC 0...10 V - (reference potential is M measuring neutral) Positioning signal forced control SAX61../MO, Fixed connecting cable 5 x 0.75 mm 2 AC/DC 24 V, Modbus RTU System neutral (SN) G + - System potential (SP) AC 24 V ~ / DC 24 V Reference (Modbus RTU) Bus + (Modbus RTU) Bus - (Modbus RTU) black red purple gray rose SAX81.. AC/DC 24 V, 3-position Sytem potential (SP) Positioning signal (actuator s stem extends) Positioning signal (actuator s stem retracts) 8 / 12

Connection diagrams SAX31.. AC 230 V L L Y1 Y2 N N1 A Actuator L Phase N Neutral N1 Controller Y1, Y2 Positioning signals N SAX61.. A F2 F3 F4 M N1 SN SP U Y Z Actuator Frost protection thermostat; terminals: 1 2 frost hazard / sensor is interrupted (thermostat closes with frost) 1 3 normal operation Temperature detector Frost protection monitor with 0 1000 Ω signal output, does NOT support QAF21.. or QAF61.. Measuring neutral Controller System neutral System potential AC/DC 24 V Position feedback - (reference potential is M measuring neutral) Position signal Positioning signal forced control SAX61../MO A Actuator G0 System neutral (SN) G System potential (SP) N1 Controller REF Reference (Modbus RTU) + Bus + (Modbus RTU) - Bus - (Modbus RTU) SAX81.. A Actuator N1 Controller SN System neutral SP System potential AC/DC 24 V Y1, Y2 Positioning signals 9 / 12

A6V101006034M01 Dimensions Type A B C C1 C2 D E SAX..(U 1) ) 1,780 SAX../MO 2) 242 124 150 68 82 80 100 100 200 1,930 With ASK39.1: SAX..(U 1) ) 267 154 300 200 100 - - - - 2,010 1) SAX..U: For 1/2" tube connections (21.5 mm dia.); 1,850 kg; 2,080 kg with ASK39.1 1) Device contains fixed connecting cable left cable duct used External Modbus converter Type X [kg] SAX../MO 250 0.15 1) 1) Already included in the total weight Dimensions in mm 10 / 12

Revision numbers SAX31.00 SAX31.03 SAX61.03.. SAX61.03/MO SAX81.00.. SAX81.03.. Type..H..H..H..H..H..H Valid from rev. no. 11 / 12

Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies 12 / 12 Siemens Switzerland Ltd, 2011 Technical specifications and availability subject to change without notice.