Wireless 0-1 ma Current Meter

Similar documents
Wireless Digital Compass

Wireless Accelerometer - G-Force Snapshot Sensor

VDC. Wireless VDC Voltage Meters. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications. General Description

Wireless Asset Sensor

The Leading Enterprise Internet of Things Solution. Wireless Accelerometer - G-Force Snapshot Sensor. Features of Monnit ALTA Sensors

Wireless Dry Contact Sensor

HUMIDITY. The Leading Enterprise Internet of Things Solution. Wireless Humidity Sensors. Features of Monnit ALTA Sensors. General Description

Wireless Dry Contact Sensor

The Leading Enterprise Internet of Things Solution. Wireless Temperature Sensors TEMPERATURE. General Description. Features of Monnit ALTA Sensors

Wireless Activity Sensors

Wireless Humidity (RH) Sensor

Wireless Open / Closed Sensor

Wireless Activity Sensors

The Leading Enterprise Internet of Things Solution. Wireless Accelerometer - G-Force Snapshot Sensor. General Description

Wireless Accelerometer - Impact Detect Sensor General Description Features of Monnit ALTA Sensors Principle of Operation Example Applications

Wireless Button Press Sensor

Wireless Low Temperature Sensor

Wireless High Temperature Sensor

Wireless Open / Closed Sensor

MonnitLink Wireless Cellular Gateways

The Leading Enterprise Internet of Things Solution. Cellular Gateways. General Description. ALTA Cellular Gateway Features. Wireless Range Comparison

Wireless Dry Contact Sensor

Pharmaceutical / Lab. ALTA Wireless IoT Sensors Kit. Kit Data Sheet. Things are talking. The only 1000 / 10-yr. IoT Sensors Platform in the World

Agriculture. ALTA Wireless IoT Sensors Kit. Kit Data Sheet. Things are talking. The only 1000 / 10-yr. IoT Sensors Platform in the World

Industrial Manufacturing

Corporate Property. ALTA Wireless IoT Sensors Kit. Kit Data Sheet. Things are talking. The only 1000 / 10-yr. IoT Sensors Platform in the World

Remote Real Estate. ALTA Wireless IoT Sensors Kit. Kit Data Sheet. Things are talking. The only 1000 / 10-yr. IoT Sensors Platform in the World

Monnit Wireless Sensors. and Ethernet Gateway Quick Start Guide

GS828. GPRS Data Logger

Standards. Electromechanical Safety Switches. Industrial Safety Products 179

ALTA Serial Modbus (RTU/ASCII) Gateway Quick Start Guide

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

GS828-H. GPRS Data Logger

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

PAR-WT50R-E PAR-WR51R-E

Important Information KX-NTV150. Communication IP Camera. IP Video Doorphone. Model No. Model No. KX-NTV160

Installation and Operating Instructions for Differential Pressure Sensor Water Tank Level Long Range Telemetry System.

and Ethernet Gateway Quick Start Guide

SP6R Level Controller Operation Manual

KWJ-WSN & USB Gateway. Quick Start Guide

5000 SERIES UNINTERRUPTIBLE POWER SYSTEMS

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

USER MANUAL. MOVEit Bluetooth

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches

A New, Standalone 24 Vdc Field Power Supply Reduces Costs, Simplifies Connectivity for Distributed I/O Devices on Industrial Machinery

E2Q4 Square Proximity Sensor

Arlo Pro 2 Wire-Free HD Camera Security System. Every Angle Covered. Pet Monitoring. Wire-Free or Plugged in. Security Made Simple

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

Conductive Level Controller

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Arlo Pro Wire-Free HD Camera Security System. Protect What Matters Most. Home. Business Security. Pet Monitoring

Datalog IoT User Manual

PFXGP4503TAD. Pro-face Xycom GP4000 PFXGP4503TAD

SLA Battery Capacity Analyzer

HAZARD SIGNS. Toxic Gases DANGER 5727 D, F 5726 D, F. Danger. Cyanide. 400 Volts 5734 D, F 5733 D, F DANGER DANGER. Electrocution risk.

Model volt to 24 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2

Installation and Operating Instructions for Air-Bubbler Differential Pressure Aquagauge Tank Level Telemetry System.

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Solar Combiner Enclosure

Arlo Pro 2 Wire-Free HD Camera Security System. Every Angle Covered. Wire-Free or Plugged In. Security Made Simple. Pet Monitoring

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

JT400 Multivariable Transmitter

Type 4 Disconnect Enclosures

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

HOBO MX1101 Temperature Data Logger

Smart manufacturing. Smart city solutions. Digital factory Smart city Big data. Air pollution. Sound meter. Events alert. Energy consumption

TSR PRO and TSR PRO-HB User s Manual May 2011

ICS Entrance Management Sign Installation Guide. Version 1.0

LED Accu Penta 9x12W RGBWAU

PRO11. Weather Station CaipoBase

COIN CELL CR2032. (Only for LED flash light) BRIEF SPECIFICATION

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail

globaltag For Everything You Can t Afford to Lose

Cam Positioner H8PS. Plastic body, 2 m (6.56 ft.) cable Metal body, 2 m (6.56 ft.) cable

Deep Blue 10 Waterproof Bluetooth Speaker (IPX-6)

Product description for ED1600 generic Sigfox Module

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

Cylindrical Proximity Sensor

Product Name: P&S. Monitor8 Plug&Sense! Waspmotes and Sensors. Reference:

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

SURGELOGIC TM. Surge Protective Device Transient Voltage Surge Suppressor (TVSS) XGA, XT, XF, XP Series. Class Schneider Electric Brands

Industrial 1-Port Ultra PoE to 2-Port 802.3bt/at Gigabit PoE Extender

Harrier. Controllers. Electronic Chemical Injection Rate Controllers

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Cable specifications PVC

Instruction Manual. Electronic Self-Leveling Dual Grade Horizontal / Vertical Rotary Laser Model No

The Portable Air Pollution Monitor

PFXGP4601TAD. Pro-face Xycom GP4000 PFXGP4601TAD

Installation Guide for America Solar Wholesale Photovoltaic Modules

Audio Unlimited poolpod 900MHz Wireless Floating & Waterproof Speaker Cables Unlimited: SPK-POOL UPC: sets per master carton

Handheld Odor Meter OMX-ADM. Operation Manual. Ver

INSEBO2IRF 2.1MP 1080P IP Eyeball Camera with IR

Arlo Wire-Free HD Camera Security System

SP6R-LSC CONTROLLER. User Manual. DUPLEX LIFT STATION CONTROL BAR GRAPH 4-20 ma INPUT AUTOMATIC ALTERNATION MOTOR STATUS LEDs

Low Power Modbus GPRS Data Logger

NSRT_mk2. Data Sheet. June Bruno Paillard

151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

Chip Immune Inductive Prox E2EZ

Transcription:

The Leader in Low-Cost, Remote Monitoring Solutions Wireless 0-1 ma Current Meter 0-1 ma 0-1mA CURRENT METER General Description The Wireless 0-1 ma DC Current Meter is designed to work with the Flex-Core MCT5 current transducer that converts 5 Amps AC into a DC signal up to 1 ma. (Additionally a current transformer (CT) can be used to interface the MCT5 to higher amperage systems.) Measures current up to 1 ma DC Principle of Operation Free imonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email. Monnit Sensor Core Specifications : 250-300 ft. (non line-of-sight / indoors / through walls, ceilings & floors) * Communication: RF 900, 920, 868 and 433 MHz Power: Replaceable batteries (optimized for long battery life) - Line-power (AA version) and solar (Industrial version) options available Battery Life (at 1 hour heartbeat setting) ** AA battery > 4-8 years Coin Cell > 2-3 years. Industrial > 4-8 years * Actual range may vary depending on environment. ** Battery life is determined by sensor reporting frequency and other variables. By connecting the leads of the Monnit wireless 0-1 ma current meter to the output of the Flex-Core MCT5 current transducer, the sensor will wirelessly transmit the data through a Monnit Gateway to the imonnit Online Sensor Monitoring and Notification System. The sensors data is transformed back to the original current reading and stored in the online system where it can be reviewed and exported as a data sheet or graph. Notifications can be set up through the online system to alert the user when certain thresholds have been met or exceeded. Example Applications Current transducers ph sensors Dissolved oxygen sensors Pressure sensors Magnetic flow sensors And many more...

1.125 in (28.575 mm) 2.0 in (50.8 mm) 0.875 in (22.225 mm) Wireless 0-1 ma Current Meter (Coin Cell) - Technical Specifications Supply Voltage 2.0-3.6 VDC * Operating Temperature Range (Board Circuitry and Coin Cell) -7 C to +60 C (20 F to +140 F) ** Optimal Battery Temperature Range (Coin Cell) +10 C to +50 C (+50 F to +122 F) 1.0 oz. Power Options Sensors are powered by a replaceable 3.0 V coin cell battery. Optional AA battery powered sensors are available. The AA version of these sensors are larger in size (3 [L] x 2.1 [W] x 1.2 [H] ) and include two long-life AA batteries. It is recommended that unless you are using the AA battery solution, you set heartbeat to no faster than one hour to preserve battery life. PinchPower Enclosure _ CR2032 BATTERY CR2032 BATTERY + Pinch (press in on the sides) Pull (sensor away from base) Press (sensor back into base) PAGE 2

2.470 4.375 3.295 1.111 1.111 Wireless 0-1 ma Current Meter (AA) - Technical Specifications Supply Voltage 2.0-3.6 VDC (3.0-3.6 VDC Using Power Supply) * Operating Temperature Range (Board Circuitry and Batteries) -18 C to 55 C (0 F to 130 F) using alkaline -40 C to 85 C (-40 F to 185 F) using lithium ** Optimal Battery Temperature Range (AA) +10 C to +50 C (+50 F to +122 F) Power Options 4.0 oz. Two replaceable 1.5V AA sized batteries are included with the standard model. A line-power version with battery backup is also available - allowing it to be powered by a standard 3.0-3.6V power supply and use the internal batteries if there is a power interruption. Power options must be selected at time of purchase as the internal hardware of the sensor must be changed to support the selected power requirements. PAGE 3

Industrial Wireless Sensor 2.316 in (58.84 mm) 3.701 in (94.0 mm) Height: 1.378 in (35.0 mm) Wireless 0-1 ma Current Meter (Industrial) - Technical Specifications Supply Voltage 2.0-3.6 VDC * Operating Temperature Range (Board Circuitry and Battery) Included Battery Max Temperature Range: -40 C to +85 C (-40 F to +185 F) ** Capacity: 1800 mah Optional Solar Feature Solar Panel: 5VDC / 30mA (53mm x 30mm) Charging Temperature Range: 0 C to 45 C (32 F to 113 F) Max Temperature Range: -20 C to 60 C (-4 F to 140 F) Included Rechargeable Battery: 600 mah / >2000 Charge Cycles (80% of initial capacity) Enclosure Rating NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed & weather proof UL Rating UL Listed to UL508-4x specifications (File E194432) 5.0 oz. Solar Power Option Monnit Industrial Sensors are powered by a replaceable 3.6V Lithium battery (included). An optional solar powered version is also available. The solar powered sensor uses a Lithium Iron Phosphate rechargeable battery in conjunction with a solar power cell to extend battery life. PAGE 4

Notes: Commercial Grade Sensors Monnit commercial grade sensors are designed for applications in ordinary environments (normal room temperature, humidity and atmospheric pressure). Do not use these sensors under the following conditions as these factors can deteriorate the product characteristics and cause failures and burn-out. Corrosive gas or deoxidizing gas - chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas, nitric oxides gas, etc.) Volatile or flammable gas Dusty conditions Under low or high pressure Wet or excessively humid locations Places with salt water, oils chemical liquids or organic solvents Where there are excessively strong vibrations Other places where similar hazardous conditions exist Use these products within the specified temperature range. Higher temperature may cause deterioration of the characteristics or the material quality. Industrial Grade Sensors - Type 1, 2, 4, 4X, 12 and 13 NEMA Rated Enclosure Monnit s Industrial sensors are enclosed in reliable, weatherproof NEMA rated enclosures. Our NEMA rated enclosures are constructed for both indoor or outdoor use and protect the sensor circuitry against the ingress of solid foreign objects like dust as well as the damaging effects of water (rain, sleet, snow, splashing water, and hose directed water). Safe from falling dirt Protects against wind-blown dust Protects against rain, sleet, snow, splashing water, and hose directed water Increased level of corrosion resistance Will remain undamaged by ice formation on the enclosure For more information about our products or to place an order, please contact our sales department at 801-561-5555. Visit us on the web at www.monnit.com. Monnit Corporation 3400 South West Temple Salt Lake City, UT 84115 801-561-5555 www.monnit.com Monnit, imonnit and all other trademarks are property of Monnit, Corp. 2018 Monnit Corp. All Rights Reserved. MDS-038-1B (1/18)