REGULATION ASPECTS 21 CFR PART11. 57, av. Général de Croutte TOULOUSE (FRANCE) (0) Fax +33 (0)

Similar documents
21 CFR PART 11 COMPLIANCE

Compliance Matrix for 21 CFR Part 11: Electronic Records

WHITE PAPER AGILOFT COMPLIANCE WITH CFR 21 PART 11

Exhibitor Software and 21 CFR Part 11

ISSUE N 1 MAJOR MODIFICATIONS. Version Changes Related Release No. PREVIOUS VERSIONS HISTORY. Version Date History Related Release No.

The Impact of 21 CFR Part 11 on Product Development

NucleoCounter NC-200, NucleoView NC-200 Software and Code of Federal Regulation 21 Part 11; Electronic Records, Electronic Signatures (21 CFR Part 11)

COMPLIANCE. associates VALIDATOR WHITE PAPER. Addressing 21 cfr Part 11

TECHNICAL BULLETIN [ 1 / 13 ]

White Paper Assessment of Veriteq viewlinc Environmental Monitoring System Compliance to 21 CFR Part 11Requirements

Compliance of Shimadzu Total Organic Carbon (TOC) Analyzer with FDA 21 CFR Part 11 Regulations on Electronic Records and Electronic Signatures

Assessment of Vaisala Veriteq viewlinc Continuous Monitoring System Compliance to 21 CFR Part 11 Requirements

Adobe Sign and 21 CFR Part 11

21 CFR Part 11 Module Design

ChromQuest 5.0. Tools to Aid in 21 CFR Part 11 Compliance. Introduction. General Overview. General Considerations

OpenLAB ELN Supporting 21 CFR Part 11 Compliance

Integration of Agilent UV-Visible ChemStation with OpenLAB ECM

21 CFR Part 11 FAQ (Frequently Asked Questions)

SDA COMPLIANCE SOFTWARE For Agilent ICP-MS MassHunter Software

Integration of Agilent OpenLAB CDS EZChrom Edition with OpenLAB ECM Compliance with 21 CFR Part 11

Introduction 2. History. Adapted to zenon version 6.20 (MH) January 13 th, 2006

Agilent ICP-MS ChemStation Complying with 21 CFR Part 11. Application Note. Overview

Using "TiNet 2.5 Compliant SR1" software to comply with 21 CFR Part 11

INFORMATION. Guidance on the use of the SM1000 and SM2000 Videographic Recorders for Electronic Record Keeping in FDA Approved Processes

EZChrom Elite Chromatography Data System. Regulatory Compliance with FDA Rule of Electronic Records and Electronic Signatures (21 CFR Part 11)

21 CFR Part 11 LIMS Requirements Electronic signatures and records

Electronic Data Processing 21 CFR Part 11

FDA 21 CFR Part 11 Compliance by Metrohm Raman

Using Chromeleon 7 Chromatography Data System to Comply with 21 CFR Part 11

Metrohm White paper. FDA 21 CFR Part 11 Requirements for NIR Spectroscopy. Dr. N. Rühl

Sparta Systems Stratas Solution

Using Chromeleon Chromatography Management Software to Comply with 21 CFR Part 11

Using "IC Net 2.2 " software to comply with 21 CFR Part 11

Sparta Systems TrackWise Solution

Part 11 Compliance SOP

Sparta Systems TrackWise Digital Solution

Using the Titrando system to comply with 21 CFR Part 11

Guidelines for applying FactoryTalk View SE in a 21 CFR Part 11 environment

Technical Information

System Assessment Report Relating to Electronic Records and Electronic Signatures; 21 CFR Part 11. System: tiamo (Software Version 2.

Validation Checklist Appendix A WiZARD2 Secure and 21 CFR 11 Requirements

How to get your Movicon 11 project FDA 21 CFR Part 11 ready. Document: RAC-4105 Released: Updated: Rel. Movicon: 11.

System Assessment Report Relating to Electronic Records and Electronic Signatures; 21 CFR Part 11. System: StabNet (Software Version 1.

Using the Titrando system to comply with 21 CFR Part 11

21 CFR 11 Assistant Software. 21 CFR Part 11 Compliance Booklet

ComplianceQuest Support of Compliance to FDA 21 CFR Part 11Requirements WHITE PAPER. ComplianceQuest In-Depth Analysis and Review

System Assessment Report Relating to Electronic Records and Electronic Signatures; Final Rule, 21 CFR Part 11

Summary. Implementing CFR21 Part 11 with Movicon 11 Page 2

Agilent Response to 21CFR Part11 requirements for the Agilent ChemStation Plus

Cell Therapy Data Management

System Assessment Report Relating to Electronic Records and Electronic Signatures; Final Rule, 21 CFR Part 11. System: tiamo 2.3

Guidance for a 21 CFR Part 11 implementation on Microsoft Office SharePoint Server 2007

Spectroscopy Configuration Manager (SCM) Software. 21 CFR Part 11 Compliance Booklet

OM-MICROLITE-8 AND OM- MICROLITE-16 DATA LOGGERS AND OM-MICROLAB

21 CFR PART 11 FREQUENTLY ASKED QUESTIONS (FAQS)

Achieving 21 CFR Part 11 Compliance using CENTUM VP

Meeting regulatory compliance guidelines with Agilent ICP-MS MassHunter and OpenLAB Server

Electronic Records and Signatures with the Sievers M9 TOC Analyzer and DataPro2 Software

Agilent Technologies Dissolution Workstation Software Electronic Records and Data Storage Background

Achieving 21 CFR Part11 Compliance using Exaquantum/Batch Authored by Stelex

Introduction. So what is 21 CFR Part 11? Who Should Comply with 21CFR Part 11?

Achieving 21 CFR Part 11 Compliance using CENTUM VP

Real World Examples for Part 11 Technical Controls

EU Annex 11 Compliance Regulatory Conformity of eve

21 CFR Part 11 Fundamentals

Minnesota State Colleges and Universities System Procedures Chapter 5 Administration

ABB Limited. Table of Content. Executive Summary

Electronic Signature Policy

21 CFR Part 11 Compliance DELMIA Apriso 2018 Implementation Guide

Premium HMI and FDA 21 Part 11 regulations TN0009. Version Description Date 1 First emission 10/04/2012

ORA HIPAA Security. All Affiliate Research Policy Subject: HIPAA Security File Under: For Researchers

System Assessment Report Relating to Electronic Records and Electronic Signatures; Final Rule, 21 CFR Part 11. System: tiamo 2.0

eprost System Policies & Procedures

DFARS Requirements for Defense Contractors Must Be Satisfied by DECEMBER 31, 2017

Statement of 21 CFR Part 11 Validation Results

5. The technology risk evaluation need only be updated when significant changes or upgrades to systems are implemented.

Automation Change Management for Regulated Industries

Supersedes: S-EG-06. Specifications relating to event loggers for electricity and gas metering devices

Complying with FDA's 21 CFR Part 11 Regulation

Red Flags/Identity Theft Prevention Policy: Purpose

e-authentication guidelines for esign- Online Electronic Signature Service

User Manual. Version 1 1/10/ of 26

Information Security Policy

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

Implementing Electronic Signature Solutions 11/10/2015

Disclosure text - PDS (PKI Disclosure Statement) for electronic signature and authentication certificates

Electronic Data Capture (EDC) Systems and Part 11 Compliance

MySign Electronic Signature

Management: A Guide For Harvard Administrators

testo Comfort Software CFR 4 Instruction manual

ELECTRONIC RECORDS (EVIDENCE) ACT (No. 13 of 2014) ELECTRONIC RECORDS (EVIDENCE) REGULATIONS. (Published on, 2015) ARRANGEMENT OF REGULATIONS

Controls Electronic messaging Information involved in electronic messaging shall be appropriately protected.

SECURITY & PRIVACY DOCUMENTATION

NIST Compliance Controls

Withdrawal of Notice of Intent to Temporarily Place Mitragynine and 7- AGENCY: Drug Enforcement Administration, Department of Justice

Policy Document. PomSec-AllSitesBinder\Policy Docs, CompanyWide\Policy

Support for the HIPAA Security Rule

Virginia Commonwealth University School of Medicine Information Security Standard

HIPAA Security Checklist

TIME SYSTEM SECURITY AWARENESS HANDOUT

Transcription:

REGULATION ASPECTS 21 CFR PART11 57, av. Général de Croutte - 31100 TOULOUSE (FRANCE) - +33 (0)5 34 47 40 00 - Fax +33 (0)5 34 47 43 01

Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-16.12.2014 2/13 B.DOC

MODIFICATION RECORD Index Date of modification Modified Paragraph & Description A August 09, 2012 Document was created from version v5.0..19 B December 16, 2014 XFP renaming to SIMATIC IT EBR: Update of document to replace wording XFP,E2S and ELAN. Page 2 : Trademarks and Disclaimer of liability note Analysis based on Code of Federal regulations Title 21 revised as of April 1, 2014 FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-16.12.2014 3/13 B.DOC

Subpart A General provisions 11.1 Scope (a) The regulations in this part set forth the criteria under which the agency considers electronic records, electronic signatures, and handwritten signatures executed to electronic records to be trustworthy, reliable, and generally equivalent to paper records and handwritten signatures executed on paper. (b) This part applies to records in electronic form that are created, modified, maintained, archived, retrieved, or transmitted, under any records requirements set forth in agency regulations. This part also applies to electronic records submitted to the agency under requirements of the Federal Food, Drug, and Cosmetic Act and the Public Health Service Act, even if such records are not specifically identified in agency regulations. However, this part does not apply to paper records that are, or have been, transmitted by electronic means. (c) Where electronic signatures and their associated electronic records meet the requirements of this part, the agency will consider the electronic signatures to be equivalent to full handwritten signatures, initials, and other general signings as required by agency regulations, unless specifically excepted by regulation(s) effective on or after August 20, 1997. (d) Electronic records that meet the requirements of this part may be used in lieu of paper records, in accordance with 11.2, unless paper records are specifically required. (e) Computer systems (including hardware and software), controls, and attendant documentation maintained under this part shall be readily available for, and subject to, FDA inspection. (f) This part does not apply to records required to be established or maintained by 1.326 through 1.368 of this Not applicable FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 4/13

chapter. Records that satisfy the requirements of part 1, subpart J of this chapter, but that also are required under other applicable statutory provisions or regulations, remain subject to this part. 11.2 Implementation (a) For records required to be maintained but not submitted to the agency, persons may use electronic records in lieu of paper records or electronic signatures in lieu of traditional signatures, in whole or in part, provided that the requirements of this part are met. (b) For records submitted to the agency, persons may use electronic records in lieu of paper records or electronic signatures in lieu of traditional signatures, in whole or in part, provided that: (1) The requirements of this part are met; and (2) The document or parts of a document to be submitted have been identified in public docket No. 92S- 0251 as being the type of submission the agency accepts in electronic form. This docket will identify specifically what types of documents or parts of documents are acceptable for submission in electronic form without paper records and the agency receiving unit(s) (e.g., specific center, office, division, branch) to which such submissions may be made. Documents to agency receiving unit(s) not specified in the public docket will not be considered as official if they are submitted in electronic form; paper forms of such documents will be considered as official and must accompany any electronic records. Persons are expected to consult with the intended agency receiving unit for details on how (e.g., method of transmission, media, file formats, and technical protocols) and whether to proceed with the electronic submission. Not applicable FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 5/13

11.3 Definitions (a) The definitions and interpretations of terms contained in section 201 of the act apply to those terms when used in this part. (b) The following definitions of terms also apply to this part: (1) Act means the Federal Food, Drug, and Cosmetic Act (secs. 201-903 (21 U.S.C. 321-393)). (2) Agency means the Food and Drug Administration. (3) Biometrics means a method of verifying an individual's identity based on measurement of the individual's physical feature(s) or repeatable action(s) where those features and/or actions are both unique to that individual and measurable. (4) Closed system means an environment in which system access is controlled by persons who are responsible for the content of electronic records that are on the system. (5) Digital signature means an electronic signature based upon cryptographic methods of originator authentication, computed by using a set of rules and a set of parameters such that the identity of the signer and the integrity of the data can be verified. (6) Electronic record means any combination of text, graphics, data, audio, pictorial, or other information representation in digital form that is created, modified, maintained, archived, retrieved, or distributed by a computer system. (7) Electronic signature means a computer data compilation of any symbol or series of symbols executed, adopted, or authorized by an individual to be the legally binding equivalent of the individual's handwritten signature. (8) Handwritten signature means the scripted name or (4) A closed system is a system accessible to the employees of a same company (of a same site or of different sites). The company is responsible for the data recorded in the system, of their exploitation, and of the security of the entire system. FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 6/13

legal mark of an individual handwritten by that individual and executed or adopted with the present intention to authenticate a writing in a permanent form. The act of signing with a writing or marking instrument such as a pen or stylus is preserved. The scripted name or legal mark, while conventionally applied to paper, may also be applied to other devices that capture the name or mark. (9) Open system means an environment in which system access is not controlled by persons who are responsible for the content of electronic records that are on the system. Subpart B Electronic Records 11.10 Controls for closed systems. (a) (b) Persons who use closed systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls designed to ensure the authenticity, integrity, and, when appropriate, the confidentiality of electronic records, and to ensure that the signer cannot readily repudiate the signed record as not genuine. Such procedures and controls shall include the following: Validation of systems to ensure accuracy, reliability, consistent intended performance, and the ability to discern invalid or altered records. The ability to generate accurate and complete copies of records in both human readable and electronic form suitable for inspection, review, and copying by the agency. Persons should contact the agency if there are any questions regarding the ability of the agency to perform such review and copying of the electronic records SIAMTIC IT EBR enables to manage the warehouse and the workshops, from the receipt of materials till the dispatching, through the dispensary and the manufacturing file. All data created, transferred, and processed in SIMATIC IT EBR are stocked in an Oracle database. The archival storage module enables to ensure that the data are kept with time. SIMATIC IT EBR enables to print the lot tracking documents, manufacturing follow-through documents (weighing report, batch record, ), as well as all generated traces. The validation of a computerised system must not be limited to the software validation. The entire system must be qualified (equipment, network, servers, software, ). This application security must imperatively be completed by a system security (servers, databases, ). Logically: with passwords. Physically: by restricting the access to the servers rooms. FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 7/13

(c) Protection of records to enable their accurate and ready retrieval throughout the records retention period. The archival storage module ensures the keeping of the final recordings and their full consultation. (d) Limiting system access to authorized individuals. SIMATIC IT EBR controls accesses at the application level through the users management. (e) (f) (g) (h) Use of secure, computer-generated, time-stamped audit trails to independently record the date and time of operator entries and actions that create, modify, or delete electronic records. Record changes shall not obscure previously recorded information. Such audit trail documentation shall be retained for a period at least as long as that required for the subject electronic records and shall be available for agency review and copying. Use of operational system checks to enforce permitted sequencing of steps and events, as appropriate. Use of authority checks to ensure that only authorized individuals can use the system, electronically sign a record, access the operation or computer system input or output device, alter a record, or perform the operation at hand. Use of device (e.g., terminal) checks to determine, as appropriate, the validity of the source of data input or operational instruction. A full audit is performed as of the operator s connection. Any connection, disconnection, creation, modification, and deletion is traced by the system. That trail audit is archived with the corresponding and printable entities. The system controls the operations sequencing by defining the entities lifecycle beforehand. The access management enables to: - control and restrict the access to the application (users management with the control of the existence and validity of the operators key: login/password). - restrict the access to the data and processing through the definition of users profiles. The notion of work centre enables to assign data and actions to particular PCs. The notion of workstation enables to know from which PCs an action has been performed. Back-up procedure to be managed together with the migration and ascending compatibility of these back-up supports. This application security must imperatively be completed by a system security (servers, databases ): Logically: with passwords Physically: by limiting the access to the server room, FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 8/13

(i) (j) (k) Determination that persons who develop, maintain, or use electronic record/electronic signature systems have the education, training, and experience to perform their assigned tasks. The establishment of, and adherence to, written policies that hold individuals accountable and responsible for actions initiated under their electronic signatures, in order to deter record and signature falsification. Use of appropriate controls over systems documentation including: (1) Adequate controls over the distribution of, access to, and use of documentation for system operation and maintenance. (2) Revision and change control procedures to maintain an audit trail that documents time-sequenced development and modification of systems documentation. 11.30 Controls for open systems. Persons who use open systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls designed to ensure the authenticity, integrity, and, as appropriate, the confidentiality of electronic records from the point of their creation to the point of their receipt. Such procedures and controls shall include those identified in 11.10, as appropriate, and additional measures such as document encryption and use of appropriate digital signature standards to ensure, as necessary under the circumstances, record authenticity, integrity, and confidentiality. 11.50 Signature manifestations. (a) Signed electronic records shall contain information associated with the signing that clearly indicates all of the following: (1) The printed name of the signer; (2) The date and time when the signature was executed; and Not applicable Not applicable The Life Sciences RnD department of SIEMENS puts its change control at its clients disposal in order to ensure a full control of their system (associated list of modifications and documentation). Not applicable. All actions performed in SIMATIC IT EBR are traced by the system. The generated traces include the operator s name, the date, time, the signature subject, as well as all context data necessary to the trace exploita- FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 9/13

(b) (3) The meaning (such as review, approval, responsibility, or authorship) associated with the signature. The items identified in paragraphs (a)(1), (a)(2), and (a)(3) of this section shall be subject to the same controls as for electronic records and shall be included as part of any human readable form of the electronic record (such as electronic display or printout). 11.70 Signature/record linking. Electronic signatures and handwritten signatures executed to electronic records shall be linked to their respective electronic records to ensure that the signatures cannot be excised, copied, or otherwise transferred to falsify an electronic record by ordinary means. tion. An electronic signature is configurable for certain actions. When validating the action, the system requires an identification, with the control of the operator s identity, his validity and user rights. A comment is obligatorily requested, which enables to specify context data unknown to the system. The generated trace includes the notion of electronic signature (in addition to the other notions cited above). All traces are displayable and printable. The electronic signature data are linked to the concerned entity and stocked in a database. The access to the production database must be physically and logically protected. FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 10/13

Subpart C Electronic Signatures 11.100 General requirements. (a) (b) Each electronic signature shall be unique to one individual and shall not be reused by, or reassigned to, anyone else. Before an organization establishes, assigns, certifies, or otherwise sanctions an individual s electronic signature, or any element of such electronic signature, the organization shall verify the identity of the individual. The electronic signature is composed of a user name and a password. During the users declaration, the system controls that the name is unique. The non-reuse of a user login must be procedured. Responsibility of the regulated industry. (c) Persons using electronic signatures shall, prior to or at the time of such use, certify to the agency that the electronic signatures in their system, used on or after August 20, 1997, are intended to be the legally binding equivalent of traditional handwritten signatures. (1) The certification shall be submitted in paper form and signed with a traditional handwritten signature, to the Office of Regional Operations (HFC 100), 5600 Fishers Lane, Rockville, MD 20857. (2) Persons using electronic signatures shall, upon agency request, provide additional certification or testimony that a specific electronic signature is the legally binding equivalent of the signer s handwritten signature. 11.200 Electronic signature components and controls. (a) Electronic signatures that are not based upon biometrics shall: (1) Employ at least two distinct identification components such as an identification code and password. (i) When an individual executes a series of signings during a single, continuous period of controlled system access, the first signing shall be executed using all electronic sig- Not applicable. 2 components are necessary to identify an operator: his login/password pair. FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 11/13

nature components; subsequent signings shall be executed using at least one electronic signature component that is only executable by, and designed to be used only by, the individual. (ii)when an individual executes one or more signings not performed during a single, continuous period of controlled system access, each signing shall be executed using all of the electronic signature components. (a) (2) Be used only by their genuine owners; and Notion of confidentiality for the signatures, and notably the passwords. (a) (b) (3) Be administered and executed to ensure that attempted use of an individual s electronic signature by anyone other than its genuine owner requires collaboration of two or more individuals. Electronic signatures based upon biometrics shall be designed to ensure that they cannot be used by anyone other than their genuine owners. 11.300 Controls for identification codes/passwords. (a) Persons who use electronic signatures based upon use of identification codes in combination with passwords shall employ controls to ensure their security and integrity. Such controls shall include: Maintaining the uniqueness of each combined identification code and password, such that no two individuals have the same combination of identification code and password. The number of connection attempts is configurable. Once this number has been reached, the user is devalidated and can no longer log on to the application. An auto-lock enables to limit the fraudulent connection attempts by locking a session that has not been active for X time. Only the connected operator or a supervisor can unlock the session. The system traces these locking and unlocking. Not applicable. The system does not allow the creation of two operators with the same name (unique short name, full name, and initials). The password is chosen individually. In this way, the system ensures the combination uniqueness. FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 12/13

(b) Ensuring that identification code and password issuances are periodically checked, recalled, or revised (e.g., to cover such events as password aging). ( c) Following loss management procedures to electronically deauthorize lost, stolen, missing, or otherwise potentially compromised tokens, cards, and other devices that bear or generate identification code or password information, and to issue temporary or permanent replacements using suitable, rigorous controls. (d) (e) Use of transaction safeguards to prevent unauthorized use of passwords and/or identification codes, and to detect and report in an immediate and urgent manner any attempts at their unauthorized use to the system security unit, and, as appropriate, to organizational management. Initial and periodic testing of devices, such as tokens or cards, that bear or generate identification code or password information to ensure that they function properly and have not been altered in an unauthorized manner. The system enables to periodically manage the password modification. Not respecting that modification devalidates the operator. The system warns the user X days before the end of validity and controls the modification in order to make sure that the password is not ageing (configuration enabling to define the number of last passwords which can not be used again). Not applicable. After a certain number of connection attempts, the operator is devalidated. Only the intervention of a supervisor enables to authorise the operator again. Not applicable. FDA/21CFR PART 11 6.0 SIMATICIT_EBR_21CFR-PART11-B.DOC 16.12.2014 13/13