SIPROTEC 5 Application Note

Similar documents
SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 5 Application. SIP5-APN-027: Change of switching authority via function keys.

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Extension of BI/BO for busbar protection SIPROTEC 7SS85

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

Answers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Siprotec 7ST61 / 7ST63

SIPROTEC 5 Protection, automation, and monitoring

Perfect protection smallest space

Product Families and Positioning. Protection Portfolio

Go beyond... IEC Leverage the full potential with leading-edge expertise. Answers for infrastructure and cities.

Voltage Control of Transformers in Parallel Operation

Perfect protection smallest space

Substation Automation Products. Line differential protection RED670 Relion 670 series

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

SIPROTEC 5 Engineering Guide DIGSI 5

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

SIPROTEC Overcurrent Protection 7SJ80. Motor Protection 7SK80. Preface. Content. Data in the PROFINET IO Mapping 1. Standard Mapping

Time synchronization via IEE 1588

Change setting groups via CFC.

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

Voltage control of transformers in parallel operation.

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

A full range of monitoring solutions for surge arresters Answers for energy.

Electrical Integration with Smart Communication

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

A full range of monitoring solutions for surge arresters

IDS SAS. Station Automation System for Complex Applications

Easily configurable HMI system for power automation siemens.com/sicam

SENTRON 3VL Molded Case Circuit Breakers

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

SINAMICS DCM Cabinet. DC drive converter cabinets for fast and simple system integration. siemens.com/sinamics. Answers for industry.

Miniature circuit breakers for all applications

SIPROTEC 5 New features of V7.5

Busbar protection REB 670

SICAM AK 3. Flexible automation for all applications. Automation, telecontrol and communication for large data volume.

Miniature Circuit Breakers for Railway Applications

Reliable and precise control over electrical systems and power

SIPROTEC 5 Devices Protection, Automation and Monitoring

Always an eye to security

siemens.com/energy/transformers FITformer REG The adaptable distribution transformer Answers for energy.

Products Portfolio. Pole mounted Vacuum Recloser

POWER GRID AUTOMATION. Pág.. n. RMU Automation

SIPROTEC. Numerical Overhead Contact Line Protection for AC Traction Power Supply 7ST6. Preface. Introduction 1. Functions 2

Protection relays.

UPGRADE AND APPLICATION OF AUTOMATION SYSTEM IN T.S. 110/35/10 KV PETROVEC

Lecture 5 Substation Automation Systems. Course map

Make the sun your energy source. SOLAR

RB60 RANGE. Miniature circuit breakers

SIMEAS Q80 quality recorder: Voltage quality starts with measurement.

SEL Time-Domain Link (TiDL ) Technology

Packaged Solutions. Grid Solutions. Value Added Solutions for Protection, Control and Automation Applications. Flexible and Expandable

Protective Relays & SCADA Systems

PROTECTION, AUTOMATION & CONTROL

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Combinable for All Applications

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS

5SL Miniature Circuit Breakers

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

HYDRO HIPASE SIMPLIFY YOUR SOLUTION

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION

MiCOM P122C Time-Overcurrent Protection

New Functions and Integrated Communication Capability. The new SENTRON 3VL ETUs SENTRON 3VL. Answers for industry.

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

Secure energy supply Energy Automation for Infrastructure and Functional Buildings

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

The complete application guide to specifying a Smart-Gear power distribution solution (PDS) E50001-F710-A123-V1-4A00. Answers for energy.

TWO-WINDING TRANSFORMER DIFFERENTIAL

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

Converter SINAMICS G150. Type 6SL37102G

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Application Notes on Generator Protection Schemes

Relays - SCADA - Metering

Siemens AG Introduction

SICAM ertu Your Entry to Telecontrol Technology with Extended Functionality

Lecture 6 Substation Automation Systems

Portable Power Solutions

Power Management System. Measuring Devices for Power Distribution

Relays for Various Protection Applications / 7SV600

Sicat CMS. siemens.com/mobility. Catenary monitoring system for overhead contact line systems

Network Configuration Document Selection for New Substations Framework

Automation System Solutions

Blueprint Data Center

Applikationen & Tools. Safe switching of IO-Link motor starter combination 3RA27 with safety relay 3SK1. IO-Link. FAQ November 2012

SWT 3000 Teleprotection siemens.com

Grid Automation packaged solutions Optimal automation of medium voltage grids

Transcription:

www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-001: Properties and Functional Structure Answers for infrastructure and cities

SIPROTEC 5 Properties SIPROTEC 5 - Application: SIP5-APN-001 Properties and Functional Structure Content 1 SIPROTEC 5 Properties 3 1.1 General Properties 3 1.2 Modular Concept 3 1.3 Redundant Communication 4 2 5 2.1 Summary 5 2.2 Functional Structure 5 2.3 Function Groups (FG) 5 2.4 Function Groups (FG) 6 2.5 Interface between Function Group and Measuring Point 8 2.6 Function Group Circuit Breaker 12 2.7 Routing Matrix 12 2.8 Functions, Step/Function Blocks 13 SIP5-APN-001 2

1 SIPROTEC 5 Properties SIPROTEC 5 Application SIPROTEC 5 Properties The SIPROTEC 5 devices at the bay level are compact and can be installed directly in medium- and highvoltage switchgears. They are characterized by comprehensive integration of protection and control functions. 1.1 General Properties Powerful multiprocessor Fully digital measured value processing and control, from sampling and digitizing of measurands to closing and tripping decisions for the circuit breaker Complete galvanic and interference-free isolation of the internal processing switches from the system measuring, control, and supply circuits through instrument transformers, binary input and output modules, and DC and AC voltage converters Easy operation using an integrated operator and display panel, or using a connected personal computer with user interface Continuous display of measured and metered values at the front Storage of min/max measured values (slave pointer function) and storage of long-term mean values Storage of fault indications for system incidents (faults in system) with real-time assignment and instantaneous values for fault recording Continuous monitoring of the measurands as well as of the device hardware and software Communication with central control and storage devices possible via the device interface Battery-buffered, synchronizable clock 1.2 Modular Concept The SIPROTEC 5 modular concept ensures the consistency and integrity of all functionalities across the entire device series. Significant features here include: Modular system design in hardware, software, and communication Functional integration of various applications, such as protection, control, and fault recorder The same expansion and communication modules for all devices in the family Innovative terminal technology with easy assembly and interchangeability and the highest possible degree of safety The same functions can be configured individually across the entire family of devices Ability to upgrade with innovations possible at all times through libraries Open, scalable architecture for IT integration and new functions Multi-layered security mechanisms in all links of the security chain Self-monitoring routines for reliable localization and indication of device faults Automatic logging of access attempts and safety-critical operations on the devices and systems 3 SIP5-APN-001

catalogue SIPROTEC 5 Properties 1.3 Redundant Communication SIPROTEC 5 devices maintain complete communication redundancy: Multiple redundant communication interfaces Redundant and independent protocols to control centers possible (such as IEC 60870-5-103 and IEC 61850, either single or redundant) Redundant time synchronization (such as IRIG-B and SNTP) SIP5-APN-001 4

2 Functional Integration - Function groups, application template 2.1 Summary In this chapter the basic functional structure of SIPROTEC 5 is described. It is comprises how functions are grouped and interconnected. 2.2 Functional Structure SIPROTEC 5 devices offer greater flexibility in working with functions. Functions can be individually loaded into the device. Additionally, it is possible to copy functions within a device or between devices. Several predefined function packages that are tailored to specific applications exist for each device family. A predefined functional scope is called an application template. The existing application templates are automatically offered for selection when you create a new device in DIGSI 5. 2.3 Function Groups (FG) Functions are arranged into function groups. This simplifies working with functions (adding and copying). The function groups are primary objects, such as a line, transformer, or circuit breaker. The function groups combine functions regarding the following essential tasks: Assignment of functions to current and/or voltage converters (assignment of functions to the measuring points and thus to the protected object) Exchange of information between function groups When a function is copied into a function group, it automatically works with the measuring points assigned to the FG. Their output signals are also automatically included in the configured interfaces of the FG. The necessary integration of functions into the device is shown by the following example. EXAMPLE A breaker-and-a-half application of the 7SA86 distance protection device serves as an example. The following protection functions are required for implementation (simplified and reduced): Distance Protection (21) Over-current protection, phases (51) Circuit-breaker failure protection (50BF), for circuit breakers 1 and 2 Basic functionality (dealing with activation) Several predefined function packages that are tailored to specific applications exist for each device family. A predefined functional scope is called an application template. The existing application templates are automatically offered for selection when you create a new device in DIGSI 5. EXAMPLE You must select the correct 7SA86 application template when installing a device in DIGSI 5. In the example, you would select the application template DIS Overhead Line, grounded networks, and breaker-and-a-half 5 SIP5-APN-001

applications. This application template covers the required range of functions. Selecting this application template determines the preconfigured range of functions. This can be changed as necessary. 2.4 Function Groups (FG) Functions are arranged into function groups. This simplifies working with functions (adding and copying). The function groups are primary objects, such as a line, transformer, or circuit breaker. The function groups combine functions regarding the following essential tasks: Assignment of functions to current and/or voltage converters (assignment of functions to the measuring points and thus to the protected object) Exchange of information between function groups When a function is copied into a function group, it automatically works with the measuring points assigned to the FG. Their output signals are also automatically included in the configured interfaces of the FG. EXAMPLE The selected application template DIS overhead line, grounded systems, and breaker-and-a-half comprises 3 function groups: Protection function group line 1 Circuit-breaker function group QA 1 Circuit-breaker function group QA 2 The following figure shows the embedding of functions via function groups. SIP5-APN-001 6

Figure 1: Embedding of Functions in Function Groups There are various types of function groups depending on the device type: Protection function groups Switching function groups Protection function groups combine functions that are assigned to a protected object, that is, to the line. Depending on the type and nature of the protected object, there are different types of protection function groups (line, feeder, transformer, motor etc.). Switch function groups combine functions assigned to the local switches, that is, circuit breakers and disconnector switches (such as processing of tripping, circuit-breaker failure protection, and automatic reclosing). The number and type of function groups differ in the respective application templates, depending on the type of the device and application. You can add, copy, or even delete function groups for a specific application. You can also adapt the functional scope within a function group according to the use case. Detailed information on this can be found under Online-help DIGSI 5. 7 SIP5-APN-001

2.5 Interface between Function Group and Measuring Point The function groups receive the measurands of the current and voltage transformers from the measuring points. For this, the function groups are connected to one or more measuring points. The number of measuring points and the assignment of function groups to the measuring points are preset by the selected application template in accordance with the specific application. Therefore, this specifies which measuring point(s) and the corresponding measurands have to be used by which function within the function group. EXAMPLE The measuring points in the application template Figure 1 are assigned to the function groups as follows: The protection function group Line is attributed to the measuring points I-3ph 1, I-3ph 2, and V-3ph 1. The function group therefore receives the measured values from current transformers 1 and 2 and from voltage transformer 1. The currents of the measuring points I-3ph 1 and I-3ph 2 are added geometrically for feeder-related processing. The circuit-breaker function group QA1 is assigned to the measuring point I-3ph 1 and receives the measured values of current transformer 1. The circuit-breaker function group QA2 is assigned to measuring point I-3ph 2 and receives the measured values from current transformer 2. The user can change the assignment as needed, that is, function groups can be assigned to any of the measuring points of the device. To check or change the assignment of measuring points to the function groups, double-click Function-group connections in the DIGSI 5 project tree (see following figure). Figure 2: Project Tree in DIGSI 5 (Detail) The window for routing of the measuring points opens in the working area (see following figure, does not correspond to the example). SIP5-APN-001 8

Figure 3 Connecting Measuring Devices and Function Groups Interface between Protection (e.g. Line) and Circuit-Breaker Function Groups The protection function group(s) is/are connected to one or several circuit-breaker function groups. This connection generally determines: Which circuit breaker(s) is/are started by the protection functions of the protection FG. Start of the function circuit-breaker failure protection (if available in the circuit-breaker function group) through the protection functions of the connected protection function group Start of the function automatic reclosing (AREC, if available in the circuit-breaker function group) through the protection functions of the connected protection function group Besides the general assignment of the protection function group(s) to the circuit-breaker function groups, you can also configure the interface for specific functionalities in detail. Further information on this can be found in the following section. Figure 6 shows how to reach the detail configuration. Figure 7 shows the possible assignments in detail. These definitions are also set appropriately for the specific application, by the selected application template. EXAMPLE The link of the function group in the example shown in Figure 1 is as follows: The protection function group line is linked to both circuit-breaker function groups QA1 and QA2. This means that the operate indication of the function Distance protection generates a trip command in both circuit-breaker function groups and thus controls both circuit breakers. The function Circuit-breaker failure protection of both circuit-breaker function groups, QA1 and QA2, is also activated, if these are configured. The user can change this link, as needed, that is, protection function groups can be freely assigned to the circuit-breaker function groups. To check or change the assignment of the protection function groups to the circuit-breaker function groups, double-click Function group connections in the DIGSI 5 project tree 7SL86 (name of the device). 9 SIP5-APN-001

Figure 4: Project Tree in DIGSI 5 (Detail) The window for general routing of the function groups opens in the working area (see following figure). Figure 5: Connection of Protection Function Group Line with Circuit-Breaker Function Group Besides the general assignment of the protection function group(s) to the circuit-breaker function groups, you can also configure the interface for specific functions in detail. Proceed as follows: Open the folder of the SIPROTEC 5 device from the SIPROTEC 5 project tree. Open the folder function settings, from the SIPROTEC 5 project tree. Open the respective protection function group, in the SIPROTEC 5 project tree, for example, Line 1 (see Figure 6) SIP5-APN-001 10

Figure 6: Project Tree in DIGSI 5 (Detail) Double-click circuit-breaker interaction (see Figure 6) The window for detailed configuration of the interface between the protection function group and the circuit breaker functional group(s) opens in the working area. Configure the interface in this view, through the context menu (right-click), see Figure 7. Figure 7: Detail Configuration of the Interface between the Protection Function Groups and the Circuit- Breaker Function Groups In the detail configuration, you define: Which operate indications of the protection functions are included when the operate indication is generated Which protection functions start the automatic reclosing function Which protection functions block the automatic reclosing function Which protection functions start the function circuit-breaker failure protection 11 SIP5-APN-001

2.6 Function Group Circuit Breaker At least one function group circuit breaker must be applied. In the breaker-and-a-half configuration two Circuit Breaker Function Groups are required. The typical functions in the FG Circuit Breaker are: Figure 8: Function Circuit Breaker Most of the shown functions can be inserted or deleted, but the Functions General, Trip logic, Circuitbreaker and Manual close are always present. 2.7 Routing Matrix Routing of the signals to (Trip and Close) and from (auxiliary contacts) the circuit breaker is done in the Routing Matrix: Figure 9: Routing of trip signals Where single pole tripping is required the phase selective trip signals must be routed in parallel to the three pole trip. In the above example the Binary Outputs 1 to 3. The auxiliary contact status is connected to the Position Signals. These are of DPC (Controllable Double Point) type. At the binary input the auxiliary contact is considered feedback information which may have one of 4 states: SIP5-APN-001 12

CH CL OH OL Close High Close Low Open High Open Low SIPROTEC 5 Application The shown assignment: Position 3-pole OH, and the 3 phase positions 1-pole CH, ensures phase selective auxiliary contact status as well as secure detection of non-plausible states when e.g. there is a failure of the auxiliary supply routed to the contacts. 2.8 Functions, Step/Function Blocks As already shown in Figure 1, functions are assigned to the protected objects or other primary objects via function groups. Functions can be further subdivided. For example, protection functions often consist of protection stages (for example, the overcurrent-protection function). Other functions can contain one or more function blocks. Thus the distance protection, for example, offers different zone types and a power-swing blocking. EXAMPLE In Figure 1 you can see, that the function Overcurrent protection, phases (51) has 3 stages. The number of zones of the function Distance protection is not shown. Each stage, each function block, and each function (without stages/function blocks) can be individually switched into specific operating modes (for example, switch on/off). To adjust the functionality to the specific application, functions, tripping stages, and function blocks can be added, copied, and deleted. 13 SIP5-APN-001

Published by and copyright 2013: Siemens AG Infrastructure & Cities Sector Smart Grid Division Humboldtstr. 59 90459 Nuremberg, Germany Siemens AG Infrastructure & Cities Sector Smart Grid Division Energy Automation Humboldtstr. 59 90459 Nuremberg, Germany www.siemens.com/protection Printed on elementary chlorine-free bleached paper. All rights reserved. If not stated otherwise on the individual pages of this catalog, we reserve the right to include modifications, especially regarding the stated values, dimensions and weights. Drawings are not binding. All product designations used are trademarks or product names of Siemens AG or other suppliers. If not stated otherwise, all dimensions in this catalog are given in mm. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract. For more information, please contact our Customer Support Center. Tel.: +49 180 524 8437 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: support.ic@siemens.com Application note: SIP5-APN-001