DELTA i-system wall switch single UP 221/2 5WG AB_2

Similar documents
DELTA profil wall switch, single UP 241/2 5WG AB_2

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

Push button UP 287, 4 - fold

Use of the application program

Product and Application Description

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Push Button Interface UP 220D31

252F 5WG FB_1 DELTA

Functional description. Use of the application program. GAMMA instabus Application program description. June C0 Sensor Switch

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

584 5WG AB_1 DELTA

Product and functional description

Weather station AP 257/51

Weather station GPS AP 257/61 Weather station AP 257/51

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and functional description

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and functional description

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Application Description

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

Product and functional description

Product and Applications Description

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Product and functional description

Product and functional description

Product and Function Description

Product and function description

Product documentation

Product documentation

Operating and mounting instructions

Use of the application program

Product documentation

Use of the application program

KNX/EIB Product documentation. Page 1 of 23. Order-No xx Order-No xx Order-No xx Order-No xx

Product documentation

Installation Instructions

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

KNX USB INTERFACE UIMtp

EIB/KNX ENO Radio bus interface (32-channel)

Use of the application program. Functional description. GAMMA instabus Application program description. March S1 rocker (BCU2)

Use of the application program. Table of Contents. GAMMA instabus Application program description. April B0 CO Room Control Unit

GVS K-BUS R KNX/EIB Push Button Sensor Contents 1. Summary

B.IQ push button comfort 1-4gang, Flush-mounted (Up) x, x, x, x

Four-channel Venetian blind actuator 230 V Installation Instructions

1 Safety instructions. 2 Device components. KNX Touch/Glass sensor comfort

Product documentation

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Water-protected surface-mounted push-button bus coupler Order No , , ,

Building Control GAMMA instabus

Air Quality Sensor KNX AQS

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

Selection and Application Guide compelling FLEXIBLE. LCP3000EZ Lighting Control. Global network of innovation

Room controller LS 990 / LS plus Stainless Steel / Aluminium

Status display unit with P-bus connection

Technical Datasheet clima RCM-CC

Operating Instructions VEGAMET 381

Technische Daten: instabus EIB supply instabus line: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

Line Coupler, MDRC LK/S 3.1, GH Q R0001

DELTA style 6/1. 6/6 Introduction. 6/7 Frames. 6/8 Switches and pushbuttons. 6/14 Socket outlets. 6/16 International plug-and-socket devices

TXM1.8RB. TX-I/O Blinds module

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

DOCUMENTATION MECrf TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 24 November 2017

Shutter/Blind Controls

Surface-Mounting Product Ranges

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016

Transponder card holder

USB RF INTERFACE UIMrf

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Display Panel BAT 100 LSN. en Operation Guide

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

HDL KNX / EIB-BUS HDL KNX / EIB BUS M/HS05.1. (Intelligent Installation Systems) Product Manual. Contents

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

Transponder card reader

Operating voltage Maximum

B.IQ push button 3gang, Flush-mounted (Up) x

1. Function 1. System M multi-function push-button, 4- gang, with room temperature control unit. Table of Contents

EDIFICIOS INTELIGENTES Y MULTIMEDIA: DOMOTICA Y CABLEADO ESTRUCTURADO

EY-RU 355: Room operating unit, ecounit355

ABB i-bus KNX Binary Inputs BE/S Product Manual

Room Temperature Controller

Line Coupler, MDRC LK/S 2.1, GH Q R0001

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

EY-RU : Room operating unit, ecounit

Push-buttons 18. Light scenes push-buttons 21. Push-buttons with thermostat 22. Labelling ields 24

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

Product documentation

Room unit with PPS2 interface

EMO valve drive. 1. Function 1. Table of Contents. 2. Installation

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

Rotary version, three-position control

PRESENCE DETECTOR, CONSTANT LIGHT CONTROLLER PD00D01KNX. Product Handbook

Electrical devices may only be mounted and connected by electrically skilled persons.

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

6173 AG GJB A0138

Digital input modules

Transcription:

DELTA i-system wall switch single UP 221/2 5WG1 221-2AB_2 UP 221/3,with status LED 5WG1 221-2AB_3 wall switch double UP 222/2, 5WG1 222-2AB_2 UP 222/3,with status LED 5WG1 222-2AB_3 wall switch triple UP 223/2, 5WG1 223-2AB_2 UP 223/3,with status LED 5WG1 223-2AB_3 UP 223/4,with temperature sensor 5WG1 223-2AB_4 UP 223/5,with IR receiver decoder 5WG1 223-2AB_5 Product wall switch, single wall switch, double wall switch, triple electro white 5WG1 221-2AB02 5WG1 222-2AB02 5WG1 223-2AB02 without status LED titanium white 5WG1 221-2AB12 5WG1 222-2AB12 5WG1 223-2AB12 carbon metallic 5WG1 221-2AB22 5WG1 222-2AB22 5WG1 223-2AB22 aluminum metallic 5WG1 221-2AB32 5WG1 222-2AB32 5WG1 223-2AB32 electro white 5WG1 221-2AB03 5WG1 222-2AB03 5WG1 223-2AB03 with status LED titanium white 5WG1 221-2AB13 5WG1 222-2AB13 5WG1 223-2AB13 carbon metallic 5WG1 221-2AB23 5WG1 222-2AB23 5WG1 223-2AB23 aluminum metallic 5WG1 221-2AB33 5WG1 222-2AB33 5WG1 223-2AB33 with status LED, electro white 5WG1 223-2AB04 scene controller, and titanium white 5WG1 223-2AB14 room temperature carbon metallic 5WG1 223-2AB24 sensor aluminum metallic 5WG1 223-2AB34 with status LED, scene controller, and IR receiver decoder electro white titanium white carbon metallic aluminum metallic Figure 1: Mounting wall switch DELTA i-system 5WG1 223-2AB05 5WG1 223-2AB15 5WG1 223-2AB25 5WG1 223-2AB35 F1 Bus coupling unit (BTM) UP 117 F2 Bus Transceiver Interface (BTI) on Bus coupling unit (BTM) F3 Design frame (DELTA line, vita, miro) F4 Bus Transceiver Interface (BTI) on wall switch module F5 Basic push button module F6 Transparent frame with buttons F7 Mounting screws F8 Back cover (white) for labeling insert F9 Learning button for switching between normal operating mode and addressing mode for receiving the physical address F10 LED for indicating normal operating mode (LED off) and addressing mode (LED on); upon receiving the physical address the device automatically returns to normal operating mode F11 switch button Siemens AG UP 22x/2, UP 22x/3, UP 22x/4 and UP 22x/5, 8 pages Technical manual Low Voltage Distribution Siemens AG 2010 Update: http://www.siemens.com/gamma 2.16.1.11/1

DELTA i-system wall switch single wall switch double wall switch triple Product and Applications Description The wall switches for the DELTA i-system (DELTA line, DELTA vita, DELTA miro) have one, two or three horizontally arranged pairs of buttons. A labelling field is placed in the middle between these buttons. These types of wall switches are available: Wall switch single, double and triple, with one orientation LED, without status LED. Wall switch single, double and triple, with one orientation LED and with one status LED per button. Wall switch triple, with one orientation LED, with one status LED per button, scene controller, and room temperature sensor. Wall switch triple, with one orientation LED, with one status LED per button, scene controller, and IR receiverdecoder. The wall switches are mounted together with the design frame DELTA line, DELTA vita, or DELTA miro onto a bus coupling unit (BTM). At the same time the electrical connection between the wall switch and the bus coupling unit (BTM) is established via the Bus Transceiver Interface (BTI). Bus coupling unit (BTM) and the design frame DELTA line, DELTA vita, or DELTA miro are not included and therefore have to be ordered separately (see current catalog). Common functions Switch buttons Depending on the model a switch provides two to six switch buttons (figure 1: A1, A2, B1, B2, C1, C2), which horizontally function as a switch pair (A to C). A1 A2 A1 B1 C1 A1 B1 A2 B2 C2 A2 B2 Horizontally aligned buttons may be used as a pair of buttons (e.g. for defined switching/dimming, or control of shutters and blinds, i.e. with the left button light is turned on and with the right button light is turned off), or as single buttons for sending values, single-button switching/dimming or single button control of blinds. Each individual switch button (A1, A2, B1, B2, C1, C2) may be assigned one of the following functions: Switching (on, off, toggle) door bell function single button dimming single button control of solar protection (blinds, roller shades) 1-bit scene control (scene 1 or 2: recall / save) 8-bit scene / effect control (recall, recall / save) Send value (8-bit value, percent) Send value (16-bit value, temperature value, brightness value) Forced control Depending on the selected main function another function may be executed either additionally after a time delay (time delay configurable from 100ms to 655s) or alternatively when the button is pressed for a longer period. When switch buttons are configured as a pair then this button pair may be assigned one of the following functions: Dual-button dimming with stop telegram Dual-button control of solar protection (blinds, roller shades) Send variable percent value Send variable 8-bit value 1-bit scene control (scene 1 and 2: recall / save) 8-bit scene / effect control (recall / save) Forced control Depending on the selected main function another function may be executed additionally after a time delay (time delay configurable from 100ms to 655s). These options are available as additional or alternative functions for single buttons or button pairs: Switching (on) Switching (off) Send percent value Send 8-bit value (0 255) Send temperature value Send brightness value Send 16-bit value (0 65535) Technical manual UP 22x/2, UP 22x/3, UP 22x/4 and UP 22x/5, 8 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2010 Low Voltage Distribution 2.16.1.11/2

DELTA i-system wall switch, single wall switch, double wall switch, triple 1-bit scene control (scene 1: recall / save) 1-bit scene control (scene 2: recall / save) 8-bit scene / effect control: recall Forced on Forced off Deactivate forced control Orientation lighting The orientation light (LED) of the device may be turned on or off continuously or depending on a status object. These configuration options are available for the orientation light (LED): LED permanently off LED permanently on LED indicates IR activity (only for switch with IR receiver) LED indicates user operation LED indicates long button press A binary status object controls the LED for each status value on (=1) or off (=0) respectively to either o on o off o flash, slowly (0,3 Hz) o flash, moderately (1 Hz) o flash, fast (5 Hz) An analog status object (8-bit value [0...255], percent value, 16-bit value [0...65535], temperature value [0 C...40 C], brightness value [0...2000 lux] controls the LED for each of up to three value ranges respectively to either o on o off o flash, slowly (0,3 Hz) o flash, moderately (1 Hz) o flash, fast (5 Hz) The brightness of the orientation light is configurable and may be controlled via object (e.g. for night operation). Additional functions of devices with status LED Status LED The same configuration options as for the orientation LED are available for the status LED s of a device. LED permanently off LED permanently on LED indicates IR activity (only for switch with IR receiver) LED indicates user operation LED indicates long button press A binary status object controls the LED for each status value on (=1) or off (=0) respectively to either o on o off o flash, slowly (0,3 Hz) o flash, moderately (1 Hz) o flash, fast (5 Hz) An analog status object (8-bit value [0...255], percent value, 16-bit value [0...65535], temperature value [0 C...40 C], brightness value [0...2000 lux] controls the LED for each of up to three value ranges respectively to either o on o off o flash, slowly (0,3 Hz) o flash, moderately (1 Hz) o flash, fast (5 Hz) The brightness of the status LED can be configured mutually for all status LED s and can be influenced via object (e.g. for night operation). To find a switch when its associated status LED is turned off and it is dark, this LED may be configured to cyclically flash briefly. Scene controller [applies only to UP 22x/4 and UP 22x/5] The scene controller enables integration of those actuators, which themselves do not provide 8-bit scene control, into 8-bit scene control schemes. Up to eight scene channels (A H) are controlled via a single 8-bit scene object. For each channel one of these functions may be selected: Switching Solar protection control Forced control 8-bit value 16-bit value Each channel may be assigned to up to eight different scene numbers (1...64). Scenes are recalled with a short button press and saved with a long button press. Before saving a scene the actuators belonging to that scene must be set to the desired light levels and switching states. When receiving a save telegram for an 8-bit scene via the 8-bit scene object the scene controller interrogates the current values and states of the actuators via the corresponding objects and saves these values and states as scene settings for the associated scene number. Saved scene values are only deleted by a new configuration of the device if the parameter Delete scene memory after bus voltage recovery is set to Yes. Siemens AG UP 22x/2, UP 22x/3, UP 22x/4 and UP 22x/5, 8 pages Technical manual Low Voltage Distribution Siemens AG 2010 Update: http://www.siemens.com/gamma 2.16.1.11/3

DELTA i-system wall switch single wall switch double wall switch triple Room temperature sensor [applies only to UP 22x/4] The room temperature may be transmitted cyclically or on change of value. To accommodate local circumstances the measured room temperature may be offset by a configurable value. IR receiver [applies only to UP 22x/5] The device offers a 16 channel IR receiver-decoder. As described for the single buttons / button pairs above, each of the 16 IR channels may be either configured for functions associated with single buttons or a button pair. Likewise, dependent on the selected main functions additional functions may be selected. The 16 channel IR hand-held remote S425/72 allows to fully exploit these possibilities. The application program already has been loaded in the factory. With the ETS (Engineering Tool Software) the specific parameters and addresses are assigned appropriately, and downloaded into the device. Function ex factory: All switch button pairs are pre-configured for the building site function for switching (left on, right off). Application program 25 C0 BTM wall switch 909301 Single, double or triple wall switch for - switching on / off / toggle - bell function (press on, release off) - dimming (with one or two buttons) - solar protection control (with one or two buttons) - send value (8-bit and 16-bit) - send variable value (8-Bit) - 1-bit and 8-bit scene control - forced control - second transmission object 8 channel scene controller with 8 scenes per channel 1 LED as orientation light 1 LED per switch button for status annunciation room temperature sensor IR receiver-decoder for 16 IR channels This application program applies to all instabus wall switches that are mounted on a bus coupling unit (BTM) UP 117. When expanding the number of switch buttons or the functionality (e.g. from UP 221/_2 to UP 223/_5) the prior configuration remains and must only be expanded. In the same simple fashion switching between design lines (DELTA line / vita / miro, DELTA profil oder DELTA style) is possible. Configuration and operation of all instabus wall switches is identical independent of design and the number of switch buttons Technical manual UP 22x/2, UP 22x/3, UP 22x/4 and UP 22x/5, 8 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2010 Low Voltage Distribution 2.16.1.11/4

DELTA i-system wall switch, single wall switch, double wall switch, triple Installation notes The device can be used for permanent installation in dry interior rooms and for insertion in distribution boards or miniature housings. V WARNING The device must be mounted and commissioned by an authorised electrician. The device may be mounted in switch and socket combinations if VDE-certified devices are used exclusively. The prevailing safety rules must be heeded. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Technical data Power suply KNX bus voltage: via bus coupling unit (BTM) UP117 KNX bus current: 9mA Operating elements 1, 2 or 3 pairs of horizontally arranged switch buttons Number of switching operations: > 20000 per button 1 learning push button: for toggling between normal mode / addressing mode Display elements 1 red LED: for checking the bus voltage and for displaying normal mode / addressing mode 1 LED as orientation light in the dark UP 22x/3, UP 22x/4 and UP 22x/5: 1 red LED per switch button for status annunciation IR receiver (UP 22x/5) Range of IR transmission: approx. 25 m under these conditions: - with IR hand-held remote S 425/72 (5WG1 425-7AB72) - directed in optical direct line-of-sight - up to max. 500 Lux diffuse day-light at reception location Connections 10-pin connector (BTI): for connection to a bus coupling unit (BTM) UP 117 Physical specifications Housing: plastic dimensions (L x W x D): 55 x 55 x 24 mm (incl. spring) weight: approx. 30 g Fire load: approx. 740kJ installation: mounted on bus coupling unit (BTM) UP 117 Electrical safety Degree of pollution (according to IEC 60664-1): 2 Type of protection (according to EN 60529): IP 20 Class of protection (according to IEC 61140): III Overvoltage category (according to IEC 60664-1): III Bus: safety extra-low voltage SELV DC 24 V Device complies with: EN 50090-2-2 and IEC 60664-1 EMC requirements complies with EN 50090-2-2 Environmental specifications climatic conditions: EN 50090-2-2 ambient temperature operating: - 5... + 45 C ambient temperature non-op.: - 25... + 70 C relative humidity (non-condensing): 5 % to 93 % Reliability UP221/x and UP222/x Failure rate: 152 fit at 40 C UP223/x Failure rate: 251 fit at 40 C Markings KNX, EIB, CE CE mark In accordance with the EMC guideline (residential and functional buildings), low voltage guideline Siemens AG UP 22x/2, UP 22x/3, UP 22x/4 and UP 22x/5, 8 pages Technical manual Low Voltage Distribution Siemens AG 2010 Update: http://www.siemens.com/gamma 2.16.1.11/5

DELTA i-system wall switch single wall switch double wall switch triple Location and function of the display and operating elements without IR receiver Installation and wiring General description The wall switch is slid onto the bus coupling unit (BTM) (F1) together with its design frame (DELTA line / vita / miro) (F3). The bus coupling unit (BTM) UP 117 (F1) is already mounted into a flush-mount box (see installation instruction of the bus coupling unit (BTM) UP 117). Bus coupling unit (BTM) and the design frame DELTA line, DELTA vita, or DELTA miro are not included and therefore have to be ordered separately (see current catalog). Mounting Remove the transparent frame with the buttons (F6) from the wall switch's main module (F5) by inserting a screwdriver laterally into the recesses and lifting the transparent frame upwards from the main module. Slip the wall switch's main module (F5) together with the design frame (F3) onto the bus coupling unit (BTM) (F1). The electrical connection between the wall switch and the bus coupling unit (BTM) is established via a Bus Transceiver Interface (BTI) (F2 and F4). Securely attach the wall switch's main module to the bus coupling unit (BTM) with the screws (F7) delivered in the package. Slip the transparent frame with the buttons back onto the main module. Unmounting Remove the transparent frame with the switch buttons (F6) from the wall switch's main module (F5) by inserting a screwdriver laterally into the recesses and lifting the transparent frame upwards from the main module (figure 4). Loosen the screws (F7) securing the wall switch's main module to the bus coupling unit (BTM) (F1). Remove the wall switch's main module (F5) together with the design frame (F3) from the bus coupling unit (BTM). with IR receiver Figure 2: Display and operating elements E1 Right button(s) E2 LED s for status annunciation (not available with UP 22x/2) E3 LED for orientation lighting E4 Left button(s) E5 Labeling field E6 IR receiver (UP 22x/5 only) Technical manual UP 22x/2, UP 22x/3, UP 22x/4 and UP 22x/5, 8 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2010 Low Voltage Distribution 2.16.1.11/6

DELTA i-system wall switch, single wall switch, double wall switch, triple Figure 3: Mounting sequence F1 Bus coupling unit (BTM) UP 117 F2 Bus Transceiver Interface (BTI) on Bus coupling unit (BTM) F3 Design frame (DELTA line, vita, miro) F4 Bus Transceiver Interface (BTI) on wall switch module F5 Basic push button module F6 Transparent frame with buttons F7 Mounting screws F8 Back cover (white) for labeling insert F9 Learning button for switching between normal operating mode and addressing mode for receiving the physical address F10 LED for indicating normal operating mode (LED off) and addressing mode (LED on); upon receiving the physical address the device automatically returns to normal operating mode F11 switch buttons F12 notch F13 Orientation light (LED) Labeling To insert a label remove the transparent frame with the switch buttons (F6) from the main module (F5). Separate the white label holder (F8) from the transparent frame (F6). Label a transparent plastic labeling medium (e.g. Avery Zweckform No. J4720 for inkjet printers or Avery Zweckform No. L4770 for laser printers) that you insert into the transparent frame (F6) with the white label holder (F8). Slide the transparent frame back onto the main module (F5). Address assignment Remove the transparent frame with the switch buttons (F6) from the base module (F5) by inserting a screwdriver laterally into the recesses and lifting the transparent frame upwards from the base module. Press the learning button (F9) on the device to initiate the assignment of the physical address to the device. The programming LED (F10) turns on to indicate the programming mode. Upon receiving the physical address the device automatically returns to normal operating mode and the LED turns off. Siemens AG UP 22x/2, UP 22x/3, UP 22x/4 and UP 22x/5, 8 pages Technical manual Low Voltage Distribution Siemens AG 2010 Update: http://www.siemens.com/gamma 2.16.1.11/7

DELTA i-system wall switch single wall switch double wall switch triple Dimension drawing Dimensions in mm. General Notes The device must be mounted and commissioned by an authorised electrician. The device may be mounted in switch and socket combinations if VDE-certified devices are used exclusively. The prevailing safety rules must be heeded. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered +49 (0911) 895-7222 +49 (0911) 895-7223 E-Mail: support.automation@siemens.com www.siemens.de/automation/support-request Technical manual UP 22x/2, UP 22x/3, UP 22x/4 and UP 22x/5, 8 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2010 Low Voltage Distribution 2.16.1.11/8